Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Circ J ; 2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38839350

RESUMEN

BACKGROUND: Achieving early rhythm control and maintaining sinus rhythm are associated with improved outcomes in patients with atrial fibrillation (AF). Pulmonary vein isolation (PVI) is a validated alternative to medical rhythm control. This study determined associations between left atrial strain reservoir (LASR) and AF recurrence after PVI.Methods and Results: In all, 132 patients (88 with paroxysmal AF [PAF], 44 with persisting AF [PersAF]) who presented in sinus rhythm for de novo PVI of AF between December 2017 and January 2019 were included in the study. All patients underwent preprocedural echocardiography. After 12 months, all patients underwent 24-h Holter electrocardiogram monitoring to screen for AF recurrence. Kaplan-Meier curve analysis revealed an association between decreasing LASRand increased AF recurrence, with a cut-off at 31.4%. In univariable Cox regression analysis, LASRdemonstrated an association with AF recurrence, with hazard ratios (HR) of 0.83 (95% confidence interval [CI] 073-0.93; P=0.001) per 5% increase in univariable models and 0.83 (95% CI 073-0.95; P=0.005) in multivariable analysis. When clinical variables with age, sex and type of AF (PAF/PersAF) were included in the multivariable analysis, LASRremained relevant in a model with age (HR 0.86; 95% CI 073-1.00; P=0.046). CONCLUSIONS: In patients undergoing de novo PVI for AF, LASRcould be of use in risk stratification regarding AF recurrence.

4.
Heart Rhythm ; 21(3): 250-257, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38036235

RESUMEN

BACKGROUND: Pulsed-field ablation (PFA) is a nonthermal energy source for ablation of cardiac arrhythmias. This study investigated the prospective outcomes of a novel PFA generator in conjunction with a commercially available, contact force-sensing, focal ablation catheter. OBJECTIVE: The purpose of this study was to assess the feasibility, safety, and lesion characteristics of point-by-point PFA in consecutive patients undergoing repeat ablation of atrial fibrillation (AF). METHODS: The study involved reisolation of pulmonary veins (PVs) with electrical reconnection and the creation of an anterior line (AL) in patients with anterior substrate or durable pulmonary vein isolation (PVI). RESULTS: In 24 patients (46% female; mean age 67 ± 10 years; 67% persistent AF), successful reisolation of 27 of 27 reconnected PVs (100%) was performed. In 19 patients, AL ablation was performed, with bidirectional block in 16 (84%), median ablation time 26 [21, 33] minutes, and first-pass bidirectional block in 13 patients (68%). Acute AL reconduction occurred in 8 of 19 patients (42%). Among these 8 patients, a subsequent sustained block of the AL was achieved in 5 (63%). Ultra-high-density electroanatomic mapping revealed homogeneous but relatively large low-voltage areas in the ablated regions. Median procedural, left atrial dwell, and fluoroscopy times were 100 [90, 109] minutes, 83 [75, 98] minutes, and 10 [8, 13] minutes, respectively. No major or minor complications occurred. CONCLUSION: This study demonstrated feasibility, acute efficacy, and safety of point-by-point PFA for repeat PVI and AL ablation. Further studies are warranted to assess the long-term durability and comparison with established ablation methods.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Femenino , Persona de Mediana Edad , Anciano , Masculino , Venas Pulmonares/cirugía , Estudios Prospectivos , Resultado del Tratamiento , Fibrilación Atrial/cirugía , Atrios Cardíacos , Ablación por Catéter/métodos , Recurrencia
6.
Clin Cardiol ; 46(10): 1210-1219, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37526378

RESUMEN

BACKGROUND: Although electrophysiological (EP) centers have institutional standards, evidence on management of cardiac tamponade is lacking. AIM AND METHODS: A physician-based survey was conducted by sending out questionnaires to all hospitals in Germany performing EP procedures. To evaluate the infrastructure of EP centers and the impact of center volume and onsite cardiac surgery on the management of cardiac tamponade, the results of the survey were analyzed for low-volume (0-250 procedures per year), mid-volume (250-500 procedures), and high-volume (>500 procedures) centers, as well as for centers with and without onsite cardiac surgery. RESULTS: A total of 341 centers were identified and 189/341 (55%) returned data sets were analyzed. Most types of EP procedures are performed across all kinds of centers. Ablation of ventricular tachycardia (VT) is concentrated in higher volume centers and in centers with onsite cardiac surgery. None of the participating low-volume centers and only 13% of centers without onsite cardiac surgery responded to performing epicardial VT ablation. Irrespective of center volume and onsite cardiac surgery, neither body mass index nor age was reported to be an exclusion criterion for ablation procedures. Higher volume centers and centers with onsite cardiac surgery more often have dedicated EP laboratories and EP-nursing teams. Also, differences regarding periprocedural safety precautions and management of cardiac tamponade were found for low-, mid-, and high-volume centers, as well as for centers with and without onsite cardiac surgery. CONCLUSION: While center volume and onsite cardiac surgery do not impact patient selection, there are differences in ablation spectrum, infrastructure, periprocedural safety precautions, and treatment of tamponade.


Asunto(s)
Taponamiento Cardíaco , Ablación por Catéter , Taquicardia Ventricular , Humanos , Taponamiento Cardíaco/etiología , Taponamiento Cardíaco/cirugía , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/terapia , Taquicardia Ventricular/cirugía , Alemania/epidemiología , Ablación por Catéter/métodos , Electrofisiología , Resultado del Tratamiento
7.
J Cardiovasc Electrophysiol ; 34(9): 1802-1807, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37473404

RESUMEN

INTRODUCTION: Pulsed-field ablation (PFA) and the multielectrode radiofrequency balloon (RFB) are two novel ablation technologies to perform pulmonary vein isolation (PVI). It is currently unknown whether these technologies differ in lesion formation and lesion extent. We compared the acute lesion extent after PVI induced by PFA and RFB by measuring low-voltage area in high-density maps and the release of biomolecules reflecting cardiac injury. METHODS: PVI was performed with a pentaspline catheter (FARAPULSE) applying PFA or with the compliant multielectrode RFB (HELIOSTAR). Before and after PVI high-density mapping with CARTO 3 was performed. In addition, blood samples were taken before transseptal puncture and after post-PVI remapping and serum concentrations of high-sensitive Troponin I were quantified by immunoassay. RESULTS: Sixty patients undergoing PVI by PFA (n = 28, age 69 ± 12 year, 60% males, 39.3% persistent atrial fibrillation [AF]) or RFB (n = 32, age 65 ± 13 year, 53% males, 21.9% persistent AF) were evaluated. Acute PVI was achieved in all patients in both groups. Mean number of PFA pulses was 34.2 ± 4.5 and mean number RFB applications was 8.5 ± 3 per patient. Total posterior ablation area was significantly larger in PFA (20.7 ± 7.7 cm²) than in RFB (7.1 ± 2.09 cm²; p < .001). Accordingly, posterior ablation area for each PV resulted in larger lesions after PFA versus RFB (LSPV 5.2 ± 2.7 vs. 1.9 ± 0.8 cm², LIPV 5.5 ± 2.3 vs. 1.9 ± 0.8 cm², RSPV 4.7 ± 1.9 vs. 1.6 ± 0.5 cm², RIPV 5.3 ± 2.1 vs. 1.6 ± 0.7 cm,² respectively; p < .001). In a subset of 38 patients, increase of hsTropI was higher after PFA (625 ± 138 pg/mL, n = 28) versus RFB (148 ± 36 pg/mL, n = 10; p = .049) supporting the evidence of larger lesion extent by PFA. CONCLUSION: PFA delivers larger acute lesion areas and higher troponin release upon successful PVI than multielectrode RFB-based PVI in this single-center series.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Masculino , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Femenino , Venas Pulmonares/cirugía , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Catéteres
8.
Circ J ; 87(7): 950-956, 2023 06 23.
Artículo en Inglés | MEDLINE | ID: mdl-37286488

RESUMEN

BACKGROUND: A novel multielectrode radiofrequency balloon (RFB) catheter has been released for pulmonary vein isolation (PVI).Methods and Results: In this observational study consecutive patients with drug-refractory paroxysmal or persistent atrial fibrillation (AF) undergoing first-time PVI were enrolled in 2 high-volume ablation centers. All procedures were conducted in conjunction with a 3D-mapping system. Clinical, procedural and ablation parameters were systematically analyzed. 105 patients (58% male; 52% paroxysmal AF, 68±11.3 years mean age, left atrial volume index 38.6±14.8 mL/m2) were included. 241/412 (58.5%) PVs were successfully isolated with a single shot (SS), with a time-to-isolation of 11.6±8 s. Total number of radiofrequency applications was 892 (mean 2.2/PV), resulting in successful isolation of 408/412 (99%) PVs at the end of the procedure. Mean electrodes' impedance drop was significantly higher in the SS-PVI compared with non-SS applications (21.5±6.6 vs. 18.6±6.5 Ohm). Concordantly, higher temperature rise was observed in the SS vs. non-SS applications (10.9±4.9℃ vs. 9.6±4.7℃). CONCLUSIONS: In this multicenter real-world study, mean impedance drop and temperature rise were associated with successful SS-PVI applying the novel RFB catheter. These parameters may help to guide efficient usage of the new RF balloon.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Masculino , Femenino , Resultado del Tratamiento , Ablación por Catéter/métodos , Fibrilación Atrial/cirugía , Atrios Cardíacos , Venas Pulmonares/cirugía , Catéteres , Recurrencia
9.
Front Cardiovasc Med ; 10: 1156500, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37034336

RESUMEN

Background: Cryoballoon (CB)- based pulmonary vein isolation (PVI) remains guided by fluoroscopy and dye. The novel saline injection-based occlusion tool allows for pulmonary vein (PV)-occlusion assessment without the need for dye injection. Aim: To compare KODEX-EPD guided CB-PVI using the novel saline injection-based workflow with conventional cryoablation for acute efficacy, fluoroscopy exposure and dye volume. Methods: Consecutive atrial fibrillation (AF)- patients undergoing CB-PVI in conjunction with KODEX-EPD (CryoEPD group) were analyzed. Patients undergoing conventional CB-PVI (Cryo group) in the same time period acted as controls. Results: One hundred forty patients [91/140 (65%) persistent AF] were studied. Seventy patients underwent CryoEPD procedures [64 ± 13 years, 21 (30%) female] and seventy patients underwent Cryo procedures [68 ± 10 years, 27 (39%) female].A total of 560 PVs were identified and successfully isolated. Mean procedure time was 66 ± 15 min for the CryoEPD group, and 65 ± 19 min for the Cryo group (p = 0.3). Fluoroscopy time (CryoEPD 6 ± 4 min; Cryo 13 ± 6 min, p < 0.001) and dose area product (CryoEPD 193 [111; 297] cGycm2; Cryo 381 [268; 614] cGycm2, p < 0.001) were lower in patients undergoing CryoEPD compared with Cryo procedures. No dye was needed in the CryoEPD group while 53 ± 18 ml dye per patient were administered for the Cryo group (p < 0.001). The overall complication rate was comparable between both groups (p = 0.5). Conclusion: KODEX-EPD guided AF-ablation enables dye-free CB-based PVI with reduced fluoroscopy exposure when compared to conventional CB-ablation, without differences in acute procedural outcomes or procedure duration.

12.
J Clin Med ; 12(4)2023 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-36835891

RESUMEN

PURPOSE: Hyperglycaemia-induced oxidative stress and inflammation contribute to vascular cell dysfunction and subsequent cardiovascular events in T2DM. Selective sodium-glucose co-transporter-2 (SGLT-2) inhibitor empagliflozin significantly improves cardiovascular mortality in T2DM patients (EMPA-REG trial). Since SGLT-2 is known to be expressed on cells other than the kidney cells, we investigated the potential ability of empagliflozin to regulate glucose transport and alleviate hyperglycaemia-induced dysfunction of these cells. METHODS: Primary human monocytes were isolated from the peripheral blood of T2DM patients and healthy individuals. Primary human umbilical vein endothelial cells (HUVECs) and primary human coronary artery endothelial cells (HCAECs), and fetoplacental endothelial cells (HPECs) were used as the EC model cells. Cells were exposed to hyperglycaemic conditions in vitro in 40 ng/mL or 100 ng/mL empagliflozin. The expression levels of the relevant molecules were analysed by RT-qPCR and confirmed by FACS. Glucose uptake assays were carried out with a fluorescent derivative of glucose, 2-NBDG. Reactive oxygen species (ROS) accumulation was measured using the H2DFFDA method. Monocyte and endothelial cell chemotaxis were measured using modified Boyden chamber assays. RESULTS: Both primary human monocytes and endothelial cells express SGLT-2. Hyperglycaemic conditions did not significantly alter the SGLT-2 levels in monocytes and ECs in vitro or in T2DM conditions. Glucose uptake assays carried out in the presence of GLUT inhibitors revealed that SGLT-2 inhibition very mildly, but not significantly, suppressed glucose uptake by monocytes and endothelial cells. However, we detected the significant suppression of hyperglycaemia-induced ROS accumulation in monocytes and ECs when empagliflozin was used to inhibit SGLT-2 function. Hyperglycaemic monocytes and endothelial cells readily exhibited impaired chemotaxis behaviour. The co-treatment with empagliflozin reversed the PlGF-1 resistance phenotype of hyperglycaemic monocytes. Similarly, the blunted VEGF-A responses of hyperglycaemic ECs were also restored by empagliflozin, which could be attributed to the restoration of the VEGFR-2 receptor levels on the EC surface. The induction of oxidative stress completely recapitulated most of the aberrant phenotypes exhibited by hyperglycaemic monocytes and endothelial cells, and a general antioxidant N-acetyl-L-cysteine (NAC) was able to mimic the effects of empagliflozin. CONCLUSIONS: This study provides data indicating the beneficial role of empagliflozin in reversing hyperglycaemia-induced vascular cell dysfunction. Even though both monocytes and endothelial cells express functional SGLT-2, SGLT-2 is not the primary glucose transporter in these cells. Therefore, it seems likely that empagliflozin does not directly prevent hyperglycaemia-mediated enhanced glucotoxicity in these cells by inhibiting glucose uptake. We identified the reduction of oxidative stress by empagliflozin as a primary reason for the improved function of monocytes and endothelial cells in hyperglycaemic conditions. In conclusion, empagliflozin reverses vascular cell dysfunction independent of glucose transport but could partially contribute to its beneficial cardiovascular effects.

13.
Clin Res Cardiol ; 112(6): 795-806, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36131138

RESUMEN

PURPOSE: Pulsed-field ablation (PFA) is a new energy source to achieve pulmonary vein isolation (PVI) by targeted electroporation of cardiomyocytes. Experimental and controlled clinical trial data suggest good efficacy of PFA-based PVI. We aimed to assess efficacy, safety and follow-up of PFA-based PVI in an early adopter routine care setting. METHODS: Consecutive patients with symptomatic paroxysmal or persistent atrial fibrillation (AF) underwent PVI using the Farawave® PFA ablation catheter in conjunction with three-dimensional mapping at two German high-volume ablation centers. PVI was achieved by applying 8 PFA applications in each PV. RESULTS: A total of 138 patients undergoing a first PVI (67 ± 12 years, 66% male, 62% persistent AF) were treated. PVI was achieved in all patients by deploying 4563 applications in 546 PVs (8.4 ± 1.0/PV). Disappearance of PV signals after the first application was demonstrated in 544/546 PVs (99.6%). More than eight PFA applications were performed in 29/546 PVs (6%) following adapted catheter positioning or due to reconnection as assessed during remapping. Mean procedure time was 78 ± 22 min including pre- and post PVI high-density voltage mapping. PFA catheter LA dwell-time was 23 ± 9 min. Total fluoroscopy time and dose area product were 16 ± 7 min and 505 [275;747] cGy*cm2. One pericardial tamponade (0.7%), one transient ST-elevation (0.7%) and three groin complications (2.2%) occurred. 1-year follow-up showed freedom of arrhythmia in 90% in patients with paroxysmal AF (n = 47) and 60% in patients with persistent AF (n = 82, p = 0.015). CONCLUSIONS: PFA-based PVI is acutely highly effective and associated with a beneficial safety and low recurrence rate.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Masculino , Femenino , Estudios de Seguimiento , Venas Pulmonares/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fluoroscopía , Resultado del Tratamiento , Recurrencia
15.
Front Cardiovasc Med ; 9: 967341, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36017093

RESUMEN

Background and aim: To investigate the feasibility, acute efficacy, periprocedural safety, and procedural parameters of CB-based PVI guided by KODEX-EPD using different occlusion tool software versions. Methods and results: A total of 173 patients (60/173 (35%) paroxysmal AF, 64 ± 12 years, 66/173 (38%) female), underwent CB-based PVI guided by KODEX-EPD between August 2019 and October 2021. Acute PVI was achieved in all the patients. Total fluoroscopy time and dye volume were 13.9 [10.6-19.4] min and 47.5 [20-70] ml. Periprocedural complications occurred in 3 (2%) of the 173 patients. As part of the continued development program, different software versions were used, including 1.4.6 on 38 (22%), 1.4.6a on 33 (19%), 1.4.7 on 41 (24%), and 1.4.8 on 61 (35%) of the patients. Outcomes were compared between software versions by a univariate analysis. Sensitivity analyses were performed to account for confounders. Median fluoroscopy time was decreased by 6.4 min (37.3%), and the median volume of dye was decreased by 32.5 ml (52%) from versions 1.4.6 to 1.4.8. Software version was a significant predictor of fluoroscopy time and dye volume, while reductions in procedure duration and dose area product were observed but mainly explained via confounders. Conclusion: CB-based PVI guided by KODEX-EPD is feasible and safe. Progressive software improvements appear to be associated with lower fluoroscopy duration and dye use. Further studies are needed to evaluate the advantage of KODEX-EPD-guided compared to conventional CB-PVI.

16.
Europace ; 23(6): 958-969, 2021 06 07.
Artículo en Inglés | MEDLINE | ID: mdl-33462602

RESUMEN

AIMS: Genetically altered mice are powerful models to investigate mechanisms of atrial arrhythmias, but normal ranges for murine atrial electrophysiology have not been robustly characterized. METHODS AND RESULTS: We analyzed results from 221 electrophysiological (EP) studies in isolated, Langendorff-perfused hearts of wildtype mice (114 female, 107 male) from 2.5 to 17.7 months (mean 7 months) with different genetic backgrounds (C57BL/6, FVB/N, MF1, 129/Sv, Swiss agouti). Left atrial monophasic action potential duration (LA-APD), interatrial activation time (IA-AT), and atrial effective refractory period (ERP) were summarized at different pacing cycle lengths (PCLs). Factors influencing atrial electrophysiology including genetic background, sex, and age were determined. LA-APD70 was 18 ± 0.5 ms, atrial ERP was 27 ± 0.8 ms, and IA-AT was 17 ± 0.5 ms at 100 ms PCL. LA-APD was longer with longer PCL (+17% from 80 to 120 ms PCL for APD70), while IA-AT decreased (-7% from 80 to 120 ms PCL). Female sex was associated with longer ERP (+14% vs. males). Genetic background influenced atrial electrophysiology: LA-APD70 (-20% vs. average) and atrial ERP (-25% vs. average) were shorter in Swiss agouti background compared to others. LA-APD70 (+25% vs. average) and IA-AT (+44% vs. average) were longer in 129/Sv mice. Atrial ERP was longer in FVB/N (+34% vs. average) and in younger experimental groups below 6 months of age. CONCLUSION: This work defines normal ranges for murine atrial EP parameters. Genetic background has a profound effect on these parameters, at least of the magnitude as those of sex and age. These results can inform the experimental design and interpretation of murine atrial electrophysiology.


Asunto(s)
Fibrilación Atrial , Atrios Cardíacos , Potenciales de Acción , Animales , Arritmias Cardíacas , Fibrilación Atrial/genética , Electrofisiología Cardíaca , Femenino , Antecedentes Genéticos , Masculino , Ratones , Ratones Endogámicos C57BL
17.
Prion ; 14(1): 24-28, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-31880189

RESUMEN

Sporadic Creutzfeldt-Jakob disease is the predominant type of human prion disease. While routine diagnostic in phenotypic cases has advanced considerably, the clinical heterogeneity and rarity of subtypes continue to constitute a major clinical and diagnostic challenge. Here, we report a peculiar case of the Heidenhain-variant of MM1 sporadic Creutzfeldt-Jakob disease presenting as a stroke mimic in an 81-year-old patient with a rapid and clinically distinct course of disease as compared to previously reported cases. While 14-3-3 protein was negative, clinical findings substantiated by 18F-FDG-PET imaging and RT-QuIC-Assay were able to establish the diagnosis. We conclude that in cases presenting with rapid progressive dementia secondary to sudden cortical anopsia the Heidenhain-variant of CJD should be considered.


Asunto(s)
Proteínas 14-3-3/metabolismo , Corteza Cerebral/patología , Síndrome de Creutzfeldt-Jakob/patología , Trastornos de la Visión/patología , Anciano de 80 o más Años , Corteza Cerebral/diagnóstico por imagen , Síndrome de Creutzfeldt-Jakob/diagnóstico por imagen , Resultado Fatal , Femenino , Fluorodesoxiglucosa F18/química , Humanos , Imagen por Resonancia Magnética , Tomografía de Emisión de Positrones , Trastornos de la Visión/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...