1.
Int J Mol Sci ; 24(22)2023 Nov 08.
Artículo en Inglés | MEDLINE | ID: mdl-38003286

RESUMEN

Mechanistic modeling is useful for predicting and modulating selectivity even in early chromatographic method development. This approach is also in accordance with current analytical quality using design principles and is highly welcomed by the authorities. The aim of this study was to investigate the separation behavior of two different types of chiral stationary phases (CSPs) for the separation of ezetimibe and its related substances using the mechanistic retention modeling approach offered by the Drylab software (version 4.5) package. Based on the obtained results, both CSPs presented with chemoselectivity towards the impurities of ezetimibe. The cyclodextrin-based CSP displayed a higher separation capacity and was able to separate seven related substances from the active pharmaceutical ingredient, while the cellulose-based column enabled the baseline resolution of six impurities from ezetimibe. Generally, the accuracy of predicted retention times was lower for the polysaccharide CSP, which could indicate the presence of additional secondary interactions between the analytes and the CSP. It was also demonstrated that the combination of mechanistic modeling and an experimental design approach can be applied to method development on CSPs in reverse-phase mode. The applicability of the methods was tested on spiked artificial placebo samples, while intraday and long-term (2 years) method repeatability was also challenged through comparing the obtained retention times and resolution values. The results indicated the excellent robustness of the selected setpoints. Overall, our findings indicate that the chiral columns could offer orthogonal selectivity to traditional reverse-phase columns for the separation of structurally similar compounds.


Asunto(s)
Celulosa , Polisacáridos , Cromatografía Líquida de Alta Presión/métodos , Ezetimiba , Estereoisomerismo , Polisacáridos/química , Celulosa/química
2.
J Chromatogr A ; 1682: 463494, 2022 Oct 25.
Artículo en Inglés | MEDLINE | ID: mdl-36126559

RESUMEN

There are several potential advantages of using experimental design-based retention modeling for chromatographic method development. Most importantly, through the model-delivered systematic understanding (Design Spaces), users can benefit from increased method consistency, flexibility and robustness that can efficiently be achieved at lesser amount of development time. As a result, modeling tools have always been great supplementary assets and welcomed by both the pharmaceutical industry and the regulatory authorities. Most recently published chapters of ICH however - Q2(R2) and Q14 (both currently drafts) - evidence a further paradigm shift, specifying the elements of model-based development strategies in the so-called "enhanced approach". The main aim of this study was to investigate the impact of stationary phase chemistries on chromatographic method performance in the application example of ezetimibe and its related substances. A commercial modeling software package (DryLab®) was used to outline three-dimensional experimental design frameworks and acquire model Design Spaces (DSs) of 9 tested columns. This was done by performing 12 input calibration experiments per column, systematically changing critical method parameters (CMPs) as variables such as the gradient time (tG), temperature (T) and the ternary composition (tC) of the mobile phase. The constructed models allowed studying retention behaviors of selected analytes within each separation systems. In the first part of our work, we performed single optimizations for all nine stationary phases with substantially different surface modifications based on their highest achievable critical resolution values. For these optimum points in silico robustness testing was performed, clearly showing a change of CMPs, depending on the column, and specified optimum setpoint. In the second part of our work, we simultaneously compared the three-dimensional virtual separation models to identify all method parameter combinations that could provide at least baseline separation (Rs, crit.>1.50). These overlapping areas between the models described a common method operational design region (MODR) where columns were considered completely interchangeable - in terms of their baseline resolving capability - regardless of their exact physicochemical properties. A final optimized, column-independent working point within the common MODR was selected for verification. Indeed, experimental chromatograms showed excellent agreement with the model; all columns in the common condition were able to yield critical resolution values higher than 2.0, only their retentivity (elution window of peaks) was found different in some cases. Our results underline that a profound understanding of the separation process is of utmost importance andthat in some cases, adequate selectivity is achievable on various stationary phases.


Asunto(s)
Cromatografía Líquida de Alta Presión , Calibración , Cromatografía Líquida de Alta Presión/métodos , Ezetimiba , Temperatura
3.
J Pharm Biomed Anal ; 203: 114203, 2021 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-34153936

RESUMEN

Computer-aided ultrahigh performance liquid chromatographic (UHPLC) method development and optimization was undertaken in order to replace an underperforming European Pharmacopoeia method for the determination of albendazole and its related substances. In the preliminary screening, a temperature-gradient time bidimensional model was chosen to aid selection of the proper stationary phase. Hereinafter temperature-gradient time-ternary composition and temperature-gradient time-pH tridimensional models were applied for the optimization of critical method parameters. The simulation and in silico robustness testing were realized using DryLab modeling software. The final method was validated for quantification of impurities and assay of the active substance according to the current ICH guidance. The validated methods were tested on a real, commercial tablet formulation. The experimental design-based and software-assisted method development proved to be a fast and reliable way of replacing a method with inadequate selectivity and long runtime with a robust UHPLC-based method, which offers baseline separation for all monitored impurities in 10 min. Results confirm that software-based chromatographic modelling can not only speed up the analytical method development process, but also improve the reliability of the developed method.


Asunto(s)
Albendazol , Cromatografía Líquida de Alta Presión , Cromatografía Liquida , Simulación por Computador , Reproducibilidad de los Resultados
4.
Acta Pharm ; 68(2): 171-183, 2018 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-29702478

RESUMEN

A reverse-phase HPLC (RP-HPLC) method was developed for strontium ranelate using a full factorial, screening experimental design. The analytical procedure was validated according to international guidelines for linearity, selectivity, sensitivity, accuracy and precision. A separate experimental design was used to demonstrate the robustness of the method. Strontium ranelate was eluted at 4.4 minutes and showed no interference with the excipients used in the formulation, at 321 nm. The method is linear in the range of 20-320 µg mL-1 (R2 = 0.99998). Recovery, tested in the range of 40-120 µg mL-1, was found to be 96.1-102.1 %. Intra-day and intermediate precision RSDs ranged from 1.0-1.4 and 1.2-1.4 %, resp. The limit of detection and limit of quantitation were 0.06 and 0.20 µg mL-1, resp. The proposed technique is fast, cost-effective, reliable and reproducible, and is proposed for the routine analysis of strontium ranelate.


Asunto(s)
Conservadores de la Densidad Ósea/análisis , Cromatografía Líquida de Alta Presión/métodos , Cromatografía de Fase Inversa/métodos , Tiofenos/análisis , Excipientes/química , Reproducibilidad de los Resultados , Proyectos de Investigación