1.
Heart Rhythm ; 18(12): 2110-2114, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34517119

RESUMEN

BACKGROUND: More than 3 million cardiovascular implantable electronic devices (CIEDs) are implanted annually. There are minimal data regarding the timing of diagnosis of acute complications after implantation. It remains unclear whether patients can be safely discharged less than 24 hours postimplantation. OBJECTIVE: The purpose of this study was to determine the precise timing of acute complication diagnosis after CIED implantation and optimal timing for same-day discharge. METHODS: A retrospective cohort analysis of adults 18 years or older who underwent CIED implantation at a large urban quaternary care medical center between June 1, 2015, and March 30, 2020, was performed. Standard of care included overnight observation and chest radiography 6 and 24 hours postprocedure. Medical records were reviewed for the timing of diagnosis of acute complications. Acute complications included pneumothorax, hemothorax, pericardial effusion, lead dislodgment, and implant site hematoma requiring surgical intervention. RESULTS: A total of 2421 patients underwent implantation. Pericardial effusion or cardiac tamponade was diagnosed in 13 patients (0.53%), pneumothorax or hemothorax in 19 patients (0.78%), lead dislodgment in 11 patients (0.45%), and hematomas requiring surgical intervention in 5 patients (0.2%). Of the 48 acute complications, 43 (90%) occurred either within 6 hours or more than 24 hours after the procedure. Only 3 acute complications identified between 6 and 24 hours required intervention during the index hospitalization (0.12% of all cases). CONCLUSION: Most acute complications are diagnosed either within the first 6 hours or more than 24 hours after implantation. With rare exception, patients can be considered for discharge after 6 hours of appropriate monitoring.


Asunto(s)
Taponamiento Cardíaco , Desfibriladores Implantables/efectos adversos , Intervención Médica Temprana , Hematoma , Hemotórax , Marcapaso Artificial/efectos adversos , Complicaciones Posoperatorias , Implantación de Prótesis , Anciano , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/métodos , Taponamiento Cardíaco/epidemiología , Taponamiento Cardíaco/terapia , Unidades de Observación Clínica/estadística & datos numéricos , Diagnóstico Precoz , Intervención Médica Temprana/métodos , Intervención Médica Temprana/normas , Intervención Médica Temprana/estadística & datos numéricos , Femenino , Hematoma/epidemiología , Hematoma/terapia , Hemotórax/epidemiología , Hemotórax/terapia , Humanos , Masculino , Complicaciones Posoperatorias/clasificación , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/prevención & control , Implantación de Prótesis/efectos adversos , Implantación de Prótesis/instrumentación , Implantación de Prótesis/métodos , Radiografía Torácica/métodos , Estudios Retrospectivos , Nivel de Atención , Tiempo de Tratamiento/organización & administración
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA