Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 167
Filtrar
1.
Adv Biol (Weinh) ; 8(3): e2300428, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38015104

RESUMEN

Optogenetics is a powerful approach in neuroscience research. However, other tissues of the body may benefit from controlled ion currents and neuroscience may benefit from more precise optogenetic expression. The present work constructs three subcellularly-targeted optogenetic actuators based on the channelrhodopsin ChR2-XXL, utilizing 5, 10, or 15 tandem repeats (TR) from mucin as N-terminal targeting motifs and evaluates expression in several polarized and non-polarized cell types. The modified channelrhodopsin maintains its electrophysiological properties, which can be used to produce continuous membrane depolarization, despite the expected size of the repeats. This work then shows that these actuators are subcellularly localized in polarized cells. In polarized epithelial cells, all three actuators localize to just the lateral membrane. The TR-tagged constructs also express subcellularly in cortical neurons, where TR5-ChR2XXL and TR10-ChR2XXL mainly target the somatodendrites. Moreover, the transfection efficiencies are shown to be dependent on cell type and tandem repeat length. Overall, this work verifies that the targeting motifs from epithelial cells can be used to localize optogenetic actuators in both epithelia and neurons, opening epithelia processes to optogenetic manipulation and providing new possibilities to target optogenetic tools.


Asunto(s)
Mucinas , Optogenética , Mucinas/metabolismo , Channelrhodopsins/metabolismo , Neuronas/metabolismo , Polaridad Celular
2.
Int J Mol Sci ; 24(24)2023 Dec 08.
Artículo en Inglés | MEDLINE | ID: mdl-38139102

RESUMEN

Due to the limitations of conventional Brucella detection methods, including safety concerns, long incubation times, and limited specificity, the development of a rapid, selective, and accurate technique for the early detection of Brucella in livestock animals is crucial to prevent the spread of the associated disease. In the present study, we introduce a magnetic nanoparticle marker-based biosensor using frequency mixing magnetic detection for point-of-care testing and quantification of Brucella DNA. Superparamagnetic nanoparticles were used as magnetically measured markers to selectively detect the target DNA hybridized with its complementary capture probes immobilized on a porous polyethylene filter. Experimental conditions like density and length of the probes, hybridization time and temperature, and magnetic binding specificity, sensitivity, and detection limit were investigated and optimized. Our sensor demonstrated a relatively fast detection time of approximately 10 min, with a detection limit of 55 copies (0.09 fM) when tested using DNA amplified from Brucella genetic material. In addition, the detection specificity was examined using gDNA from Brucella and other zoonotic bacteria that may coexist in the same niche, confirming the method's selectivity for Brucella DNA. Our proposed biosensor has the potential to be used for the early detection of Brucella bacteria in the field and can contribute to disease control measures.


Asunto(s)
Brucella , Brucelosis , Nanopartículas de Magnetita , Animales , Brucella/genética , Brucelosis/diagnóstico , Brucelosis/microbiología , ADN , Cartilla de ADN/genética , Sensibilidad y Especificidad
3.
Sci Rep ; 13(1): 20669, 2023 11 24.
Artículo en Inglés | MEDLINE | ID: mdl-38001109

RESUMEN

Mechanical stimulation is a promising means to non-invasively excite and modulate neuronal networks with a high spatial resolution. Despite the thorough characterization of the initiation mechanism, whether or how mechanical responses disperse into non-target areas remains to be discovered. Our in vitro study demonstrates that a single-neuron deformation evokes responses that propagate to about a third of the untouched neighbors. The responses develop via calcium influx through mechanosensitive channels and regeneratively propagate through the neuronal ensemble via gap junctions. Although independent of action potentials and synapses, mechanical responses reliably evoke membrane depolarizations capable of inducing action potentials both in the target and neighbors. Finally, we show that mechanical stimulation transiently potentiates the responding assembly for further inputs, as both gain and excitability are transiently increased exclusively in neurons that respond to a neighbor's mechanical stimulation. The findings indicate a biological component affecting the spatial resolution of mechanostimulation and point to a cross-talk in broad-network mechanical stimulations. Since giga-seal formation in patch-clamp produces a similar mechanical stimulus on the neuron, our findings inform which neuroscientific questions could be reliably tackled with patch-clamp and what recovery post-gigaseal formation is necessary.


Asunto(s)
Calcio , Neuronas , Neuronas/fisiología , Sinapsis/fisiología , Potenciales de Acción/fisiología , Uniones Comunicantes , Calcio de la Dieta
4.
Biosens Bioelectron ; 242: 115712, 2023 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-37816283

RESUMEN

Organic electrochemical transistors (OECTs) possess versatile advantages for biochemical and electrophysiological applications due to electrochemical gating and ion-to-electron conversion capability. Although OECTs have been successfully applied for biochemical sensing, the effect of relative capacitance for specific sensing events is still unclear. In the present work, we design integrated interdigitated OECTs (iOECTs) with on-plane gold gate and different channel geometries for point-of-care diagnosis of malaria using aptamer as receptor. The transconductance of the iOECTs gated with micro-size gold electrodes decreased with increasing the channel thicknesses, especially for devices with large channel areas, which is inconsistent with devices gated by typical Ag/AgCl electrodes, attributing to the limited gating efficiency of the micro-size gate electrode. The capacitance of gate electrode was heavily suppressed by receptors but increased with the incubation of targets. In addition, the integrated iOECTs with thin channels exhibited superior sensitivity for malaria detection with the detection limit as low as 3.2 aM, much lower than their thick channel counterpart and other state-of-the-art biosensors. These deviations could be caused by the high relative capacitances, with respect to the gate and channel capacitance (Cg/Cch), resulting in a high gate potential drop over the organic channel and thus entirely gating on the thin channel device. These findings provide guidance to optimize the geometry of OECT devices with on-chip integrated gates and the fabrication of miniaturized OECTs for biosensing applications.


Asunto(s)
Técnicas Biosensibles , Técnicas Biosensibles/métodos , Electrodos , Capacidad Eléctrica , Oligonucleótidos , Oro , Transistores Electrónicos
5.
Biosensors (Basel) ; 13(9)2023 Sep 11.
Artículo en Inglés | MEDLINE | ID: mdl-37754115

RESUMEN

Accurate determination of serotonin (ST) provides insight into neurological processes and enables applications in clinical diagnostics of brain diseases. Herein, we present an electrochemical aptasensor based on truncated DNA aptamers and a polyethylene glycol (PEG) molecule-functionalized sensing interface for highly sensitive and selective ST detection. The truncated aptamers have a small size and adopt a stable stem-loop configuration, which improves the accessibility of the aptamer for the analyte and enhances the sensitivity of the aptasensor. Upon target binding, these aptamers perform a conformational change, leading to a variation in the Faraday current of the redox tag, which was recorded by square wave voltammetry (SWV). Using PEG as blocking molecules minimizes nonspecific adsorption of other interfering molecules and thus endows an enhanced antifouling ability. The proposed electrochemical aptamer sensor showed a wide range of detection lasting from 0.1 nM to 1000 nM with a low limit of detection of 0.14 nM. Owing to the unique properties of aptamer receptors, the aptasensor also exhibits high selectivity and stability. Furthermore, with the reduced unspecific adsorption, assaying of ST in human serum and artificial cerebrospinal fluid (aCSF) showed excellent performance. The reported strategy of utilizing antifouling PEG describes a novel approach to building antifouling aptasensors and holds great potential for neurochemical investigations and clinical diagnosis.


Asunto(s)
Aptámeros de Nucleótidos , Incrustaciones Biológicas , Técnicas Biosensibles , Humanos , Serotonina , Incrustaciones Biológicas/prevención & control , Técnicas Electroquímicas , Límite de Detección , Polietilenglicoles , Aptámeros de Nucleótidos/química , Oro/química
6.
Nanomaterials (Basel) ; 13(16)2023 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-37630959

RESUMEN

Electrochemical and optical platforms are commonly employed in designing biosensors. However, one signal readout can easily lead to inaccuracies due to the effect of nonstandard test procedures, different operators, and experimental environments. We have developed a dual-signal protocol that combined two transducer principles in one aptamer-based biosensor by simultaneously performing electrochemical- and extraordinary optical transmission (EOT)-based plasmonic detection using gold nanopit arrays (AuNpA). Compared with full hole structures, we found that nanopits, that did not fully penetrate the gold film, not only exhibited a better plasmonic bandwidth and refractive index sensitivity both in the finite-difference time-domain simulation and in experiments by shielding the gold/quartz mode but also enlarged the electrochemical active surface area. Therefore, the periodic non-fully penetrating AuNpA were modified with ferrocene-labeled human serum albumin aptamer receptors. The formation of the receptor layer and human serum albumin binding complex induced a conformational change, which resulted in variation in the electron transfer between the electro-active ferrocene units and the AuNpA surface. Simultaneously, the binding event caused a surface plasmon polaritons wavelength shift corresponding to a change in the surface refractive index. Interestingly, although both transducers recorded the same binding process, they led to different limits of detection, dynamic ranges, and sensitivities. The electrochemical transducer showed a dynamic detection range from 1 nM to 600 µM, while the optical transducer covered high concentrations from 100 µM to 600 µM. This study not only provides new insights into the design of plasmonic nanostructures but also potentially opens an exciting avenue for dual-signal disease diagnosis and point-of-care testing applications.

7.
J Mater Chem B ; 11(40): 9639-9657, 2023 10 18.
Artículo en Inglés | MEDLINE | ID: mdl-37610228

RESUMEN

The combination of electrophysiology and neuroimaging methods allows the simultaneous measurement of electrical activity signals with calcium dynamics from single neurons to neuronal networks across distinct brain regions in vivo. While traditional electrophysiological techniques are limited by photo-induced artefacts and optical occlusion for neuroimaging, different types of transparent neural implants have been proposed to resolve these issues. However, reproducing proposed solutions is often challenging and it remains unclear which approach offers the best properties for long-term chronic multimodal recordings. We therefore created a streamlined fabrication process to produce, and directly compare, two types of transparent surface micro-electrocorticography (µECoG) implants: nano-mesh gold structures (m-µECoGs) versus a combination of solid gold interconnects and PEDOT:PSS-based electrodes (pp-µECoGs). Both implants allowed simultaneous multimodal recordings but pp-µECoGs offered the best overall electrical, electrochemical, and optical properties with negligible photo-induced artefacts to light wavelengths of interest. Showing functional chronic stability for up to four months, pp-µECoGs also allowed the simultaneous functional mapping of electrical and calcium neural signals upon visual and tactile stimuli during widefield imaging. Moreover, recordings during two-photon imaging showed no visible signal attenuation and enabled the correlation of network dynamics across brain regions to individual neurons located directly below the transparent electrical contacts.


Asunto(s)
Calcio , Optogenética , Electrodos Implantados , Optogenética/métodos , Electrofisiología/métodos , Oro
8.
Adv Healthc Mater ; 12(20): e2301055, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37434349

RESUMEN

Neural interfaces are evolving at a rapid pace owing to advances in material science and fabrication, reduced cost of scalable complementary metal oxide semiconductor (CMOS) technologies, and highly interdisciplinary teams of researchers and engineers that span a large range from basic to applied and clinical sciences. This study outlines currently established technologies, defined as instruments and biological study systems that are routinely used in neuroscientific research. After identifying the shortcomings of current technologies, such as a lack of biocompatibility, topological optimization, low bandwidth, and lack of transparency, it maps out promising directions along which progress should be made to achieve the next generation of symbiotic and intelligent neural interfaces. Lastly, it proposes novel applications that can be achieved by these developments, ranging from the understanding and reproduction of synaptic learning to live-long multimodal measurements to monitor and treat various neuronal disorders.


Asunto(s)
Neuronas , Semiconductores
9.
Stem Cell Rev Rep ; 19(6): 1870-1889, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37093520

RESUMEN

The healing of neuronal injuries is still an unachieved goal. Medicine-based therapies can only extend the survival of patients, but not finally lead to a healing process. Currently, a variety of stem cell-based tissue engineering developments are the subject of many research projects to bridge this gap. As yet, neuronal differentiation of induced pluripotent stem cells (iPS), embryonic cell lines, or neuronal stem cells could be accomplished and produce functional neuronally differentiated cells. However, clinical application of cells from these sources is hampered by ethical considerations. To overcome these hurdles numerous studies investigated the potential of adult mesenchymal stem cells (MSCs) as a potential stem cell source. Adult MSCs have been approved as cellular therapeutical products due to their regenerative potential and immunomodulatory properties. Only a few of these studies could demonstrate the capacity to differentiate MSCs into active firing neuron like cells. With this study we investigated the potential of Wharton's Jelly (WJ) derived stem cells and focused on the intrinsic pluripotent stem cell pool and their potential to differentiate into active neurons. With a comprehensive neuronal differentiation protocol comprised of mechanical and biochemical inductive cues, we investigated the capacity of spontaneously forming stem cell spheroids (SCS) from cultured WJ stromal cells in regard to their neuronal differentiation potential and compared them to undifferentiated spheroids or adherent MSCs. Spontaneously formed SCSs show pluripotent and neuroectodermal lineage markers, meeting the pre-condition for neuronal differentiation and contain a higher amount of cells which can be differentiated into cells whose functional phenotypes in calcium and voltage responsive electrical activity are similar to neurons. In conclusion we show that up-concentration of stem cells from WJ with pluripotent characteristics is a tool to generate neuronal cell replacement.


Asunto(s)
Células Madre Mesenquimatosas , Gelatina de Wharton , Cordón Umbilical , Diferenciación Celular/genética , Neuronas
10.
Sensors (Basel) ; 22(22)2022 Nov 14.
Artículo en Inglés | MEDLINE | ID: mdl-36433383

RESUMEN

Frequency mixing magnetic detection (FMMD) has been explored for its applications in fields of magnetic biosensing, multiplex detection of magnetic nanoparticles (MNP) and the determination of core size distribution of MNP samples. Such applications rely on the application of a static offset magnetic field, which is generated traditionally with an electromagnet. Such a setup requires a current source, as well as passive or active cooling strategies, which directly sets a limitation based on the portability aspect that is desired for point of care (POC) monitoring applications. In this work, a measurement head is introduced that involves the utilization of two ring-shaped permanent magnets to generate a static offset magnetic field. A steel cylinder in the ring bores homogenizes the field. By variation of the distance between the ring magnets and of the thickness of the steel cylinder, the magnitude of the magnetic field at the sample position can be adjusted. Furthermore, the measurement setup is compared to the electromagnet offset module based on measured signals and temperature behavior.


Asunto(s)
Imanes , Nanopartículas , Magnetismo , Campos Magnéticos , Acero
11.
Nanomaterials (Basel) ; 12(12)2022 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-35745431

RESUMEN

This study investigates the intrinsic multienzyme-like properties of the non-stabilized nanocrystalline nanoparticles of manganese-doped Prussian blue (Mn-PB) nanozymes and Prussian blue (PB) nanozymes in chemical and electrocatalytic transformations of reactive oxygen species. The effect of manganese doping on the structural, biomimetic, and electrocatalytic properties of cyano-bridged assemblies is also discussed.

12.
Int J Mol Sci ; 23(12)2022 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-35743038

RESUMEN

Calcium (Ca2+) ions play a pivotal role in physiology and cellular signaling. The intracellular Ca2+ concentration ([Ca2+]i) is about three orders of magnitude lower than the extracellular concentration, resulting in a steep transmembrane concentration gradient. Thus, the spatial and the temporal dynamics of [Ca2+]i are ideally suited to modulate Ca2+-mediated cellular responses to external signals. A variety of highly sophisticated methods have been developed to gain insight into cellular Ca2+ dynamics. In addition to electrophysiological measurements and the application of synthetic dyes that change their fluorescent properties upon interaction with Ca2+, the introduction and the ongoing development of genetically encoded Ca2+ indicators (GECI) opened a new era to study Ca2+-driven processes in living cells and organisms. Here, we have focused on one well-established GECI, i.e., GCaMP3.0. We have systematically modified the protein with sequence motifs, allowing localization of the sensor in the nucleus, in the mitochondrial matrix, at the mitochondrial outer membrane, and at the plasma membrane. The individual variants and a cytosolic version of GCaMP3.0 were overexpressed and purified from E. coli cells to study their biophysical properties in solution. All versions were examined to monitor Ca2+ signaling in stably transfected cell lines and in primary cortical neurons transduced with recombinant Adeno-associated viruses (rAAV). In this comparative study, we provide evidence for a robust approach to reliably trace Ca2+ signals at the (sub)-cellular level with pronounced temporal resolution.


Asunto(s)
Señalización del Calcio , Escherichia coli , Calcio/metabolismo , Señalización del Calcio/fisiología , Citosol/metabolismo , Escherichia coli/genética , Escherichia coli/metabolismo , Neuronas/metabolismo
13.
Small ; 18(22): e2200053, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35527345

RESUMEN

The further development of neurochips requires high-density and high-resolution recordings that also allow neuronal signals to be observed over a long period of time. Expanding fields of network neuroscience and neuromorphic engineering demand the multiparallel and direct estimations of synaptic weights, and the key objective is to construct a device that also records subthreshold events. Recently, 3D nanostructures with a high aspect ratio have become a particularly suitable interface between neurons and electronic devices, since the excellent mechanical coupling to the neuronal cell membrane allows very high signal-to-noise ratio recordings. In the light of an increasing demand for a stable, noninvasive and long-term recording at subthreshold resolution, a combination of vertical nanostraws with nanocavities is presented. These structures provide a spontaneous tight coupling with rat cortical neurons, resulting in high amplitude sensitivity and postsynaptic resolution capability, as directly confirmed by combined patch-clamp and microelectrode array measurements.


Asunto(s)
Neuronas , Potenciales de Acción , Animales , Membrana Celular , Microelectrodos , Neuronas/fisiología , Ratas , Relación Señal-Ruido
14.
Biosens Bioelectron ; 208: 114219, 2022 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-35367704

RESUMEN

Despite significant eradication efforts, malaria remains a persistent infectious disease with high mortality due to the lack of efficient point-of-care (PoC) screening solutions required to manage low-density asymptomatic parasitemia. In response, we demonstrate a quantitative electrical biosensor based on system-integrated two-dimensional field-effect transistors (2DBioFETs) of reduced graphene oxide (rGO) as transducer for high sensitivity screening of the main malaria biomarker, Plasmodium falciparum lactate dehydrogenase (PfLDH). The 2DBioFETs were biofunctionalized with pyrene-modified 2008s aptamers as specific PfLDH receptors. While we systematically optimize biosensor interface for optimal performance, aptamer-protein transduction at 2DBioFETs is elucidated based on delineation of charge and capacitance in an updated analytical model for two-dimensional rGO/biofunctional layer/electrolyte (2DiBLE) interfaces. Our 2DBioFET-aptasensors display a limit-of-detection down to 0.78 fM (0.11 pg/mL), dynamic ranges over 9 orders of magnitude (subfemto to submicromolar), high sensitivity, and selectivity in human serum validating their diagnostic potential as rapid PoC tests for malarial management.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Grafito , Malaria , Humanos , L-Lactato Deshidrogenasa , Límite de Detección , Malaria/diagnóstico , Plasmodium falciparum
15.
ACS Appl Mater Interfaces ; 14(5): 6417-6427, 2022 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-35089707

RESUMEN

A novel double-resonant plasmonic substrate for fluorescence amplification in a chip-based apta-immunoassay is herein reported. The amplification mechanism relies on plasmon-enhanced fluorescence (PEF) effect. The substrate consists of an assembly of plasmon-coupled and plasmon-uncoupled gold nanoparticles (AuNPs) immobilized onto a glass slide. Plasmon-coupled AuNPs are hexagonally arranged along branch patterns whose resonance lies in the red band (∼675 nm). Plasmon-uncoupled AuNPs are sprinkled onto the substrate, and they exhibit a narrow resonance at 524 nm. Numerical simulations of the plasmonic response of the substrate through the finite-difference time-domain (FDTD) method reveal the presence of electromagnetic hot spots mainly confined in the interparticle junctions. In order to realize a PEF-based device for potential multiplexing applications, the plasmon resonances are coupled with the emission peak of 5-carboxyfluorescein (5-FAM) fluorophore and with the excitation/emission peaks of cyanine 5 (Cy5). The substrate is implemented in a malaria apta-immunoassay to detect Plasmodium falciparum lactate dehydrogenase (PfLDH) in human whole blood. Antibodies against Plasmodium biomarkers constitute the capture layer, whereas fluorescently labeled aptamers recognizing PfLDH are adopted as the top layer. The fluorescence emitted by 5-FAM and Cy5 fluorophores are linearly correlated (logarithm scale) to the PfLDH concentration over five decades. The limits of detection are 50 pM (1.6 ng/mL) with the 5-FAM probe and 260 fM (8.6 pg./mL) with the Cy5 probe. No sample preconcentration and complex pretreatments are required. Average fluorescence amplifications of 160 and 4500 are measured in the 5-FAM and Cy5 channel, respectively. These results are reasonably consistent with those worked out by FDTD simulations. The implementation of the proposed approach in multiwell-plate-based bioassays would lead to either signal redundancy (two dyes for a single analyte) or to a simultaneous detection of two analytes by different dyes, the latter being a key step toward high-throughput analysis.


Asunto(s)
Oro/química , Nanopartículas del Metal/química , Anticuerpos Inmovilizados/química , Anticuerpos Inmovilizados/inmunología , Aptámeros de Nucleótidos/química , Aptámeros de Nucleótidos/metabolismo , Carbocianinas/química , Fluoresceínas/química , Vidrio/química , Humanos , Inmunoensayo/métodos , L-Lactato Deshidrogenasa/sangre , L-Lactato Deshidrogenasa/inmunología , Límite de Detección , Plasmodium falciparum/enzimología , Proteínas Protozoarias/sangre , Proteínas Protozoarias/inmunología , Propiedades de Superficie
16.
Anal Bioanal Chem ; 414(4): 1609-1622, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34783880

RESUMEN

An electrochemical aptamer-based sensor was developed for glutamate, the major excitatory neurotransmitter in the central nervous system. Determining glutamic acid release and glutamic acid levels is crucial for studying signal transmission and for diagnosing pathological conditions in the brain. Glutamic acid-selective oligonucleotides were isolated from an ssDNA library using the Capture-SELEX protocol in complex medium. The selection permitted the isolation of an aptamer 1d04 with a dissociation constant of 12 µM. The aptamer sequence was further used in the development of an electrochemical aptamer sensor. For this purpose, a truncated aptamer sequence named glu1 was labelled with a ferrocene redox tag at the 3'-end and immobilized on a gold electrode surface via Au-thiol bonds. Using 6-mercapto-1-hexanol as the backfill, the sensor performance was characterized by alternating current voltammetry. The glu1 aptasensor showed a limit of detection of 0.0013 pM, a wide detection range between 0.01 pM and 1 nM, and good selectivity for glutamate in tenfold diluted human serum. With this enzyme-free aptasensor, the highly selective and sensitive detection of glutamate was demonstrated, which possesses great potential for implementation in microelectrodes and for in vitro as well as in vivo monitoring of neurotransmitter release.


Asunto(s)
Aptámeros de Nucleótidos/química , Técnicas Electroquímicas/métodos , Ácido Glutámico/sangre , Técnicas Biosensibles/métodos , Ácido Glutámico/análisis , Hexanoles/química , Humanos , Límite de Detección , Compuestos de Sulfhidrilo/química
17.
Biosensors (Basel) ; 13(1)2022 Dec 30.
Artículo en Inglés | MEDLINE | ID: mdl-36671898

RESUMEN

In this work, a novel sandwich-type electrochemical immunosensor was developed for the quantitative detection of the carcinoembryonic antigen, an important tumor marker in clinical tests. The capture antibodies were immobilized on the surface of a gold disk electrode, while detection antibodies were attached to redox-tagged single-walled carbon nanohorns/thionine/AuNPs. Both types of antibody immobilization were carried out through Au-S bonds using the novel photochemical immobilization technique that ensures control over the orientation of the antibodies. The electroactive SWCNH/Thi/AuNPs nanocomposite worked as a signal tag to carry out both the detection of carcinoembryonic antigen and the amplification of the detection signal. The current response was monitored by differential pulse voltammetry. A clear dependence of the thionine redox peak was observed as a function of the carcinoembryonic antigen concentration. A linear detection range from 0.001-200 ng/mL and a low detection limit of 0.1385 pg/mL were obtained for this immunoassay. The results showed that carbon nanohorns represent a promising matrix for signal amplification in sandwich-type electrochemical immune assays working as a conductive and binding matrix with easy and versatile modification routes to antibody and redox tag immobilization, which possesses great potential for clinical diagnostics of CEA and other biomarkers.


Asunto(s)
Técnicas Biosensibles , Nanopartículas del Metal , Antígeno Carcinoembrionario , Carbono/química , Inmunoensayo/métodos , Oro/química , Técnicas Biosensibles/métodos , Nanopartículas del Metal/química , Anticuerpos , Técnicas Electroquímicas/métodos , Límite de Detección , Anticuerpos Inmovilizados/química
18.
Sci Rep ; 11(1): 18920, 2021 09 23.
Artículo en Inglés | MEDLINE | ID: mdl-34556704

RESUMEN

Chronically implanted neural probes are powerful tools to decode brain activity however, recording population and spiking activity over long periods remains a major challenge. Here, we designed and fabricated flexible intracortical Michigan-style arrays with a shank cross-section per electrode of 250 µm[Formula: see text] utilizing the polymer paryleneC with the goal to improve the immune acceptance. As flexible neural probes are unable to penetrate the brain due to the low buckling force threshold, a tissue-friendly insertion system was developed by reducing the effective shank length. The insertion strategy enabled the implantation of the four, bare, flexible shanks up to 2 mm into the mouse brain without increasing the implantation footprint and therefore, minimizing the acute trauma. In acute recordings from the mouse somatosensory cortex and the olfactory bulb, we demonstrated that the flexible probes were able to simultaneously detect local field potentials as well as single and multi-unit activity. Additionally, the flexible arrays outperformed stiff probes with respect to yield of single unit activity. Following the successful in vivo validation, we further improved the microfabrication towards a double-metal-layer process, and were able to double the number of electrodes per shank by keeping the shank width resulting in a cross-section per electrode of 118 µm[Formula: see text].

19.
Sensors (Basel) ; 21(17)2021 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-34502749

RESUMEN

Magnetic immunoassays employing Frequency Mixing Magnetic Detection (FMMD) have recently become increasingly popular for quantitative detection of various analytes. Simultaneous analysis of a sample for two or more targets is desirable in order to reduce the sample amount, save consumables, and save time. We show that different types of magnetic beads can be distinguished according to their frequency mixing response to a two-frequency magnetic excitation at different static magnetic offset fields. We recorded the offset field dependent FMMD response of two different particle types at frequencies f1 + n⋅f2, n = 1, 2, 3, 4 with f1 = 30.8 kHz and f2 = 63 Hz. Their signals were clearly distinguishable by the locations of the extremes and zeros of their responses. Binary mixtures of the two particle types were prepared with different mixing ratios. The mixture samples were analyzed by determining the best linear combination of the two pure constituents that best resembled the measured signals of the mixtures. Using a quadratic programming algorithm, the mixing ratios could be determined with an accuracy of greater than 14%. If each particle type is functionalized with a different antibody, multiplex detection of two different analytes becomes feasible.


Asunto(s)
Campos Magnéticos , Magnetismo , Inmunoensayo
20.
Sensors (Basel) ; 21(12)2021 Jun 09.
Artículo en Inglés | MEDLINE | ID: mdl-34207725

RESUMEN

Recent investigations into cardiac or nervous tissues call for systems that are able to electrically record in 3D as opposed to 2D. Typically, challenging microfabrication steps are required to produce 3D microelectrode arrays capable of recording at the desired position within the tissue of interest. As an alternative, additive manufacturing is becoming a versatile platform for rapidly prototyping novel sensors with flexible geometric design. In this work, 3D MEAs for cell-culture applications were fabricated using a piezoelectric inkjet printer. The aspect ratio and height of the printed 3D electrodes were user-defined by adjusting the number of deposited droplets of silver nanoparticle ink along with a continuous printing method and an appropriate drop-to-drop delay. The Ag 3D MEAs were later electroplated with Au and Pt in order to reduce leakage of potentially cytotoxic silver ions into the cellular medium. The functionality of the array was confirmed using impedance spectroscopy, cyclic voltammetry, and recordings of extracellular potentials from cardiomyocyte-like HL-1 cells.


Asunto(s)
Nanopartículas del Metal , Técnicas de Cultivo de Célula , Espectroscopía Dieléctrica , Microelectrodos , Plata
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...