Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Intervalo de año de publicación
1.
Transplant Direct ; 10(4): e1601, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38464425

RESUMEN

Background: Hypothermic machine perfusion (HMP) reduces renal injury in donation after circulatory death donors with a high Kidney Donor Profile Index (KDPI). This study aims to characterize the correlation between KDPI, HMP parameters, and donor vitals during the withdrawal period in predicting short- and long-term graft outcomes. Methods: ANOVA with Tukey's honestly significant difference tests compared the relationship between average flow, average resistance, peak resistance, flow slope, and resistance slope on day 30, 1-y, and 3-y eGFR, and days of delayed graft function. Graft and recipient survival rates were assessed using Kaplan-Meier analysis. Results: The data for 72 grafts were suitable for analysis. Kidneys with KDPI >50% had a significantly higher day 30, and 1-y posttransplant eGFR, if HMP average flow was >150 mL/min, or the average resistance was <0.15 mm Hg/mL/min, compared with kidneys with also KDPI >50% but had not achieved the same pump parameters. There were no significant differences in the Kaplan-Meier analysis, considering recipient or graft survival, regardless of the KPDI score with 3- or 5-y outcomes. Conclusions: Use of average resistance and average flow from a HMP, in conjunction with KDPI, may be predictive of the short- and long-term function of donation after circulatory death kidney transplants.

2.
Transplant Direct ; 10(4): e1604, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38464423

RESUMEN

Background: The Canadian Anatomic Kidney Score (CAKS) is a novel 6-point grading system that standardizes the gross description of a donor kidney across 3 components-vessels, anatomy, and sticky fat. We hypothesized that the CAKS predicts allograft functional outcomes and provides additional information to the Kidney Donor Profile Index (KDPI) and histologic assessment of the donor kidney. Methods: Single-center cohort of 145 patients who underwent renal transplantation with CAKS analysis between 2018 and 2021. CAKS was prospectively determined before transplantation. Preimplantation core biopsies were assessed according to the Remuzzi score (RS). The primary outcome was 1-y allograft function represented by an estimated glomerular filtration rate (eGFR). Results: Linear regression without adjustment for KDPI or RS showed a significant association between the CAKS and 1-y eGFR (-8.7 mL/min/1.73 m2 per point increase in CAKS; 95% CI, -13.0 to -4.4; P < 0.001). Most of that association was attributed to the vessel component (-12.1; -19.4 to -4.8; P = 0.002). Adjustment for KDPI and RS attenuated the relationship between 1-y function and CAKS (-4.6; -9.5 to 0.3; P = 0.065) and vessel component (-7.4; -15.2 to 0.5; P = 0.068). Conclusions: Anatomic assessment of donor kidneys at the time of transplantation associates with allograft function at 1 y. Vascular assessment appears to make the dominant contribution.

3.
World J Surg ; 47(11): 2846-2856, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37700108

RESUMEN

BACKGROUND: Whole pancreas transplantation provides durable glycemic control and can improve survival rate; however, it can carry an increased risk of surgical complications. One devastating complication is a duodenal leak at the site of enteroenteric anastomosis. The gastroduodenal artery (GDA) supplies blood to the donor duodenum and pancreas but is commonly ligated during procurement. Since we have not had expressive changes in pancreatic back table surgical techniques in the recent decades, we hypothesized whether back table GDA reconstruction, improving perfusion of the donor duodenum and head of the pancreas, could lead to fewer surgical complications in simultaneous pancreas-kidney (SPK) transplants. MATERIAL AND METHODS: Between 2017 and 2021, we evaluated demographic information, postoperative complications, intraoperative donor duodenum, recipient bowel O2 tissue saturation, and patient morbidity through the Comprehensive Complication Index (CCI®). RESULTS: A total of 26 patients were included: 13 underwent GDA reconstruction (GDA-R), and 13 had GDA ligation (GDA-L). There were no pancreatic leaks in the GR group compared to 38% (5/13) in the GDA-L group (p = 0.03913). Intraoperative tissue oxygen saturation was higher in the GDA-R group than in the GDA-L (95.18 vs.76.88%, p < 0,001). We observed an increase in transfusion rate in GDA-R (p < 0.05), which did not result in a higher rate of exploration (p = 0.38). CCI® patient morbidity was also significantly lower in the GDA-R group (s < 0.05). CONCLUSIONS: This study identified improved intraoperative duodenal tissue oxygen saturation in the GDA-R group with an associated reduction in pancreatic leaks and CCI® morbidity risk. A larger prospective multicenter study comparing the two methods is warranted.


Asunto(s)
Trasplante de Páncreas , Humanos , Trasplante de Páncreas/métodos , Estudios Prospectivos , Duodeno/cirugía , Páncreas/cirugía , Páncreas/irrigación sanguínea , Arteria Hepática
4.
Transpl Int ; 36: 10442, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36819126

RESUMEN

Thrombosis is a leading causes of pancreas graft loss after simultaneous pancreas kidney (SPK), pancreas after kidney (PAK), and pancreas transplant alone (PTA). There remains no standardized thromboprophylaxis protocol. The aim of this systematic review and meta-analysis is to evaluate the impact of heparin thromboprophylaxis on the incidence of pancreas thrombosis, pancreas graft loss, bleeding, and secondary outcomes in SPK, PAK, and PTA. Following PRISMA guidelines, we systematically searched BIOSIS®, PubMed®, Cochrane Library®, EMBASE®, MEDLINE®, and Web of Science® on April 21, 2021. Primary peer-reviewed studies that met inclusion criteria were included. Two methods of quantitative synthesis were performed to account for comparative and non-comparative studies. We included 11 studies, comprising of 1,122 patients in the heparin group and 236 patients in the no-heparin group. When compared to the no-heparin control, prophylactic heparinization significantly decreased the risk of early pancreas thrombosis and pancreas loss for SPK, PAK and PTA without increasing the incidence of bleeding or acute return to the operating room. Heparin thromboprophylaxis yields an approximate two-fold reduction in both pancreas thrombosis and pancreas loss for SPK, PAK and PTA. We report the dosage, frequency, and duration of heparin administration to consolidate the available evidence.


Asunto(s)
Trasplante de Riñón , Trasplante de Páncreas , Trombosis , Tromboembolia Venosa , Humanos , Heparina , Anticoagulantes , Trasplante de Riñón/efectos adversos , Trasplante de Páncreas/efectos adversos , Páncreas , Trombosis/etiología , Supervivencia de Injerto
5.
Transplant Direct ; 3(5): e155, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28573190

RESUMEN

BACKGROUND: This study compared the use of static cold storage versus continuous hypothermic machine perfusion in a cohort of kidney transplant recipients at high risk for delayed graft function (DGF). METHODS: In this national, multicenter, and controlled trial, 80 pairs of kidneys recovered from brain-dead deceased donors were randomized to cold storage or machine perfusion, transplanted, and followed up for 12 months. The primary endpoint was the incidence of DGF. Secondary endpoints included the duration of DGF, hospital stay, primary nonfunction, estimated glomerular filtration rate, acute rejection, and allograft and patient survivals. RESULTS: Mean cold ischemia time was high but not different between the 2 groups (25.6 ± 6.6 hours vs 25.05 ± 6.3 hours, 0.937). The incidence of DGF was lower in the machine perfusion compared with cold storage group (61% vs. 45%, P = 0.031). Machine perfusion was independently associated with a reduced risk of DGF (odds ratio, 0.49; 95% confidence interval, 0.26-0.95). Mean estimated glomerular filtration rate tended to be higher at day 28 (40.6 ± 19.9 mL/min per 1.73 m2 vs 49.0 ± 26.9 mL/min per 1.73 m2; P = 0.262) and 1 year (48.3 ± 19.8 mL/min per 1.73 m2 vs 54.4 ± 28.6 mL/min per 1.73 m2; P = 0.201) in the machine perfusion group. No differences in the incidence of acute rejection, primary nonfunction (0% vs 2.5%), graft loss (7.5% vs 10%), or death (8.8% vs 6.3%) were observed. CONCLUSIONS: In this cohort of recipients of deceased donor kidneys with high mean cold ischemia time and high incidence of DGF, the use of continuous machine perfusion was associated with a reduced risk of DGF compared with the traditional cold storage preservation method.

6.
Transplant Direct ; 3(5): .155-.155, 2017.
Artículo en Inglés | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1068304

RESUMEN

BACKGROUND: This study compared the use of static cold storage versus continuous hypothermic machine perfusion in a cohort of kidney transplant recipients at high risk for delayed graft function (DGF). METHODS: In this national, multicenter, and controlled trial, 80 pairs of kidneys recovered from brain-dead deceased donors were randomized to cold storage or machine perfusion, transplanted, and followed up for 12 months. The primary endpoint was the incidence of DGF. Secondary endpoints included the duration of DGF, hospital stay, primary nonfunction, estimated glomerular filtration rate, acute rejection, and allograft and patient survivals. RESULTS: Mean cold ischemia time was high but not different between the 2 groups (25.6 ± 6.6 hours vs 25.05 ± 6.3 hours, 0.937). The incidence of DGF was lower in the machine perfusion compared with cold storage group (61% vs. 45%, P = 0.031). Machine perfusion was independently associated with a reduced risk of DGF (odds ratio, 0.49; 95% confidence interval, 0.26-0.95). Mean estimated glomerular filtration rate tended to be higher at day 28 (40.6 ± 19.9 mL/min per 1.73 m2 vs 49.0 ± 26.9 mL/min per 1.73 m2; P = 0.262) and 1 year (48.3 ± 19.8 mL/min per 1.73 m2 vs 54.4 ± 28.6 mL/min per 1.73 m2; P = 0.201) in the machine perfusion group. No differences in the incidence of acute rejection, primary nonfunction (0% vs 2.5%), graft loss (7.5% vs 10%), or death (8.8% vs 6.3%) were observed...


Asunto(s)
Perfusión , Trasplante de Riñón
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...