Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 84
Filtrar
1.
Radiol Phys Technol ; 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38700638

RESUMEN

The purpose of the study is to investigate the variation in Hounsfield unit (HU) values calculated using dual-energy computed tomography (DECT) scanners. A tissue characterization phantom inserting 16 reference materials were scanned three times using DECT scanners [dual-layer CT (DLCT), dual-source CT (DSCT), and fast kilovoltage switching CT (FKSCT)] changing scanning conditions. The single-energy CT images (120 or 140 kVp), and virtual monochromatic images at 70 keV (VMI70) and 140 keV (VMI140) were reconstructed, and the HU values of each reference material were measured. The difference in HU values was larger when the phantom was scanned using the half dose with wrapping with rubber (strong beam-hardening effect) compared with the full dose without the rubber (reference condition), and the difference was larger as the electron density increased. For SECT, the difference in HU values against the reference condition measured by the DSCT (3.2 ± 5.0 HU) was significantly smaller (p < 0.05) than that using DLCT with 120 kVp (22.4 ± 23.8 HU), DLCT with 140 kVp (11.4 ± 12.8 HU), and FKSCT (13.4 ± 14.3 HU). The respective difference in HU values in the VMI70 and VMI140 measured using the DSCT (10.8 ± 17.1 and 3.5 ± 4.1 HU) and FKSCT (11.5 ± 21.8 and 5.5 ± 10.4 HU) were significantly smaller than those measured using the DLCT120 (23.1 ± 27.5 and 12.4 ± 9.4 HU) and DLCT140 (22.3 ± 28.6 and 13.1 ± 11.4 HU). The HU values and the susceptibility to beam-hardening effects varied widely depending on the DECT scanners.

2.
J Imaging Inform Med ; 2024 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-38637424

RESUMEN

While dual-energy computed tomography (DECT) technology introduces energy-specific information in clinical practice, single-energy CT (SECT) is predominantly used, limiting the number of people who can benefit from DECT. This study proposed a novel method to generate synthetic low-energy virtual monochromatic images at 50 keV (sVMI50keV) from SECT images using a transformer-based deep learning model, SwinUNETR. Data were obtained from 85 patients who underwent head and neck radiotherapy. Among these, the model was built using data from 70 patients for whom only DECT images were available. The remaining 15 patients, for whom both DECT and SECT images were available, were used to predict from the actual SECT images. We used the SwinUNETR model to generate sVMI50keV. The image quality was evaluated, and the results were compared with those of the convolutional neural network-based model, Unet. The mean absolute errors from the true VMI50keV were 36.5 ± 4.9 and 33.0 ± 4.4 Hounsfield units for Unet and SwinUNETR, respectively. SwinUNETR yielded smaller errors in tissue attenuation values compared with those of Unet. The contrast changes in sVMI50keV generated by SwinUNETR from SECT were closer to those of DECT-derived VMI50keV than the contrast changes in Unet-generated sVMI50keV. This study demonstrated the potential of transformer-based models for generating synthetic low-energy VMIs from SECT images, thereby improving the image quality of head and neck cancer imaging. It provides a practical and feasible solution to obtain low-energy VMIs from SECT data that can benefit a large number of facilities and patients without access to DECT technology.

3.
Br J Radiol ; 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38648776

RESUMEN

OBJECTIVES: A portable respiratory training system with a gyroscope sensor (GRTS) was developed and the feasibility of respiratory training was evaluated. METHODS: Simulated respiratory waveforms from a respiratory motion phantom and actual respirator waveforms from volunteers were acquired using the GRTS and Respiratory Gating for Scanners system (RGSC). Respiratory training was evaluated by comparing the stability and reproducibility of respiratory waveforms from patients undergoing liver stereotactic body radiation therapy, with and without the GRTS. The stability and reproducibility of respiratory waveforms were assessed by root mean square error and gold marker placement-based success rate of expiratory breath-hold, respectively. RESULTS: The absolute mean difference for sinusoidal waveforms between the GRTS and RGSC was 2.1%. Among volunteers, the mean percentages of errors within ±15% of the respiratory waveforms acquired by the GRTS and RGSC were 95.5% for free breathing and 80.7% for expiratory breath-hold. The mean root mean square error and success rate of expiratory breath-hold (standard deviation) with and without the GRTS were 0.65 (0.24) and 0.88 (0.89) cm, and 91.0% (6.9) and 89.1% (11.6), respectively. CONCLUSIONS: Respiratory waveforms acquired by the GRTS exhibit good agreement with waveforms acquired by the RGSC. Respiratory training with the GRTS reduces inter-patient variability in respiratory waveforms, thereby improving the success of expiratory breath-hold liver stereotactic body radiation therapy. ADVANCES IN KNOWLEDGE: A respiratory training system with a gyroscope sensor is inexpensive and portabl, making it ideal for respiratory training. This is the first report concerning clinical implementation of a respiratory training system.

4.
Radiol Phys Technol ; 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38466497

RESUMEN

To investigate the geometric accuracy of the radiation focal point (RFP) and cone-beam computed tomography (CBCT) over long-term periods for the ICON Leksell Gamma Knife radiosurgery system. This phantom study utilized the ICON quality assurance tool plus, and the phantom was manually set on the patient position system before the implementation of treatment for patients. The deviation of the RFP position from the unit center point (UCP) and the positions of the four ball bearings (BBs) in the CBCT from the reference position were automatically analyzed. During 544 days, a total of 269 analyses were performed on different days. The mean ± standard deviation (SD) of the deviation between measured RFP and UCP was 0.01 ± 0.03, 0.01 ± 0.03, and -0.01 ± 0.01 mm in the X, Y, and Z directions, respectively. The deviations with offset values after the cobalt-60 source replacement (0.00 ± 0.03, -0.01 ± 0.01, and -0.01 ± 0.01 mm in the X, Y, and Z directions, respectively) were significantly (p = 0.001) smaller than those before the replacement (0.02 ± 0.03, 0.02 ± 0.01, and -0.02 ± 0.01 mm in the X, Y, and Z directions, respectively). The overall mean ± SD of four BBs was -0.03 ± 0.03, -0.01 ± 0.05, and 0.01 ± 0.03 mm in the X, Y, and Z directions, respectively. Geometric positional accuracy was ensured to be within 0.1 mm on most days over a long-term period of more than 500 days.

5.
Cancer Diagn Progn ; 4(2): 117-121, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38434911

RESUMEN

Background/Aim: The prevalence of oropharyngeal squamous cell carcinoma (OPSCC) is increasing worldwide. This retrospective study aimed to investigate the clinical outcomes of patients with OPSCC undergoing definitive radiotherapy, stratified according to their p16 status. Patients and Methods: A retrospective analysis was conducted on consecutive patients with OPSCC treated with curative external beam radiotherapy between May 2015 and September 2023. Clinical staging was determined by the eighth edition AJCC staging manual for p16 positive and negative OPSCC. All patients were treated with radiotherapy using a simultaneous integrated boost (SIB) with helical tomotherapy. The fractionation scheme, with or without chemotherapy, for the primary site and nodal lesions consisted of 2 Gy per fraction for a total dose of 70 Gy in 35 fractions over seven weeks. Results: This study included 76 patients with a median age of 66 years. With a median follow-up time of 32.6 months, the 3-year progression-free survival rate was significantly higher in p16 positive patients compared to p16 negative patients (79.6% vs. 42.5%, p<0.001). Concerning 54 patients with p16-positive tumors, the overall survival rates indicated excellent clinical outcomes for stage I, II, and III with results of 100%, 100%, and 88.1%, respectively. Conclusion: This retrospective study revealed the clinical outcomes of patients with OPSCC treated with radical radiotherapy, emphasizing the significance of p16 status. While acknowledging the limitations of the retrospective nature of this study, future prospective studies with larger cohorts and extended follow-up periods are needed to enhance evidence quality.

6.
Med Phys ; 51(4): 2378-2385, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38421685

RESUMEN

BACKGROUND: The breath-hold radiotherapy has been increasingly used to mitigate interfractional and intrafractional breathing impact on treatment planning and beam delivery. Previous techniques include body surface measurements or radiopaque metal markers, each having known disadvantages. PURPOSE: We recently proposed a new markerless technique without the disadvantages, where diaphragm was registered between DRR and fluoroscopic x-ray projection images every 180 ms during VMAT delivery. An initial validation of the proposed diaphragm tracking system (DiaTrak) was performed using a chest phantom to evaluate its characteristics. METHODS: Diaphragm registration was performed between DRR and projection streaming kV x-ray images of a chest phantom during VMAT delivery. Streaming data including the projection images and the beam angles were transferred from a linac system to an external PC, where the diaphragm registration accuracy and beam-off latency were measured based on image cross correlation between the DRR and the projection images every 180 ms. RESULTS: It was shown that the average of the beam-off latency was 249.5 ms and the average of the diaphragm registration error was 0.84 mm CONCLUSIONS: Initial validation of the proposed DiaTrak system for multiple breath-hold VMAT of abdominal tumors has been successfully completed with a chest phantom. The resulting beam-off latency and the diaphragm registration error were regarded clinically acceptable.


Asunto(s)
Neoplasias Abdominales , Neoplasias Pulmonares , Radioterapia de Intensidad Modulada , Humanos , Diafragma/diagnóstico por imagen , Radioterapia de Intensidad Modulada/métodos , Neoplasias Pulmonares/radioterapia , Neoplasias Abdominales/diagnóstico por imagen , Neoplasias Abdominales/radioterapia , Contencion de la Respiración , Fantasmas de Imagen , Planificación de la Radioterapia Asistida por Computador/métodos
7.
In Vivo ; 38(2): 819-825, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38418123

RESUMEN

BACKGROUND/AIM: Radiotherapy (RT) outcomes are generally reported based on stage, patient background, and concomitant chemotherapy. This study aimed to investigate the effects of the prescribed dose to gross tumor volume (GTV) and the calculation algorithm on local control in definitive RT for head and neck (H&N) cancers using follow-up images after RT. PATIENTS AND METHODS: This study included 154 patients with H&N cancers treated by Volumetric Modulated Arc Therapy at the Kobe City Medical Center General Hospital. Patients were classified into those receiving definitive RT (70 Gy of irradiation) and those not receiving it. Follow-up images were used to categorize the patients into the responders and non-responders groups. In the non-responders group, follow-up images were imported into the treatment planning system, and the contours of the residual or recurrent areas (local failure) were extracted and fused with computed tomography-simulated images for treatment planning. Dose evaluation parameters included maximum dose, dose administered to 1% of the volume, dose administered to 50% of the volume, dose administered to 99% of the volume (D99%), and minimum dose (Dmin) administered to the GTV. The doses to the GTV were compared between responders and non-responders. RESULTS: D99% exhibited significant differences between local failure and responders and between local failure and non-responders. Dmin showed significant differences between responders and non-responders and between responders and local failure. CONCLUSION: This study emphasizes the importance of verifying dose distribution in all slices of treatment planning, highlighting the need for precise assessment of the dose to the GTV in head and neck cancers.


Asunto(s)
Neoplasias de Cabeza y Cuello , Radioterapia Conformacional , Radioterapia de Intensidad Modulada , Humanos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias de Cabeza y Cuello/radioterapia , Radioterapia Conformacional/métodos , Radioterapia de Intensidad Modulada/métodos
9.
Cureus ; 16(1): e51528, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38304685

RESUMEN

Thymic epithelial tumors (TETs), particularly type B2 thymomas, are rare neoplasms primarily found in the anterior mediastinum. The current therapeutic approach includes surgery, chemotherapy, and radiotherapy, but there is limited research on radiotherapy as a standalone treatment. This case report aims to elucidate the clinical outcomes of hypofractionated radiotherapy as a standalone treatment for locally advanced type B2 thymoma, offering insights into its potential efficacy and role in clinical practice.

10.
J Appl Clin Med Phys ; : e14294, 2024 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-38319652

RESUMEN

PURPOSE: To explore the potential of quantitative parameters of the hydrogel spacer distribution as predictors for separating the rectum from the planning target volume (PTV) in linear-accelerator-based stereotactic body radiotherapy (SBRT) for prostate cancer. METHODS: Fifty-five patients underwent insertion of a hydrogel spacer and were divided into groups 1 and 2 of the PTV separated from and overlapping with the rectum, respectively. Prescribed doses of 36.25-45 Gy in five fractions were delivered to the PTV. The spacer cover ratio (SCR) and hydrogel-implant quality score (HIQS) were calculated. RESULTS: Dosimetric and quantitative parameters of the hydrogel spacer distribution were compared between the two groups. For PTV, D99% in group 1 (n = 29) was significantly higher than that in group 2 (n = 26), and Dmax , D0.03cc , D1cc , and D10% for the rectum were significantly lower in group 1 than in group 2. The SCR for prostate (89.5 ± 12.2%) in group 1 was significantly higher (p < 0.05) than that in group 2 (74.7 ± 10.3%). In contrast, the HIQS values did not show a significant difference between the groups. An area under the curve of 0.822 (95% confidence interval, 0.708-0.936) for the SCR was obtained with a cutoff of 93.6%, sensitivity of 62.1%, and specificity of 100%. CONCLUSIONS: The SCR seems promising to predict the separation of the rectum from the PTV in linear-accelerator-based SBRT for prostate cancer.

11.
Phys Eng Sci Med ; 2024 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-38353926

RESUMEN

In linear accelerator-based stereotactic irradiation (STI) for brain metastasis, cone-beam computed tomography (CBCT) image quality is essential for ensuring precise patient setup and tumor localization. However, CBCT images may be degraded by the deviation of the CBCT isocenter from the brain center. This study aims to investigate the effects of the distance from the brain center to the CBCT isocenter (DBI) on the image quality in STI. An anthropomorphic phantom was scanned with varying DBI in right, anterior, superior, and inferior directions. Thirty patients undergoing STI were prospectively recruited. Objective metrics, utilizing regions of interest included contrast-to-noise ratio (CNR) at the centrum semiovale, lateral ventricle, and basal ganglia levels, gray and white matter noise at the basal ganglia level, artifact index (AI), and nonuniformity (NU). Two radiation oncologists assessed subjective metrics. In this phantom study, objective measures indicated a degradation in image quality for non-zero DBI. In this patient study, there were significant correlations between the CNR at the centrum semiovale and lateral ventricle levels (rs = - 0.79 and - 0.77, respectively), gray matter noise (rs = 0.52), AI (rs = 0.72), and NU (rs = 0.91) and DBI. However, no significant correlations were observed between the CNR at the basal ganglia level, white matter noise, and subjective metrics and DBI (rs < ± 0.3). Our results demonstrate the effects of DBI on contrast, noise, artifacts in the posterior fossa, and uniformity of CBCT images in STI. Aligning the CBCT isocenter with the brain center can aid in improving image quality.

12.
Int J Comput Assist Radiol Surg ; 19(3): 541-551, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38219257

RESUMEN

PURPOSE: While dual-energy computed tomography (DECT) images provide clinically useful information than single-energy CT (SECT), SECT remains the most widely used CT system globally, and only a few institutions can use DECT. This study aimed to establish an artificial intelligence (AI)-based image-domain material decomposition technique using multiple keV-output learning of virtual monochromatic images (VMIs) to create DECT-equivalent images from SECT images. METHODS: This study involved 82 patients with head and neck cancer. Of these, the AI model was built with data from the 67 patients with only DECT scans, while 15 patients with both SECT and DECT scans were used for SECT testing. Our AI model generated VMI50keV and VMI100keV from VMI70keV equivalent to 120-kVp SECT images. We introduced a loss function for material density images (MDIs) in addition to the loss for VMIs. For comparison, we trained the same model with the loss for VMIs only. DECT-equivalent images were generated from SECT images and compared with the true DECT images. RESULTS: The prediction time was 5.4 s per patient. The proposed method with the MDI loss function quantitatively provided more accurate DECT-equivalent images than the model trained with the loss for VMIs only. Using real 120-kVp SECT images, the trained model produced precise DECT images of excellent quality. CONCLUSION: In this study, we developed an AI-based material decomposition approach for head and neck cancer patients by introducing the loss function for MDIs via multiple keV-output learning. Our results suggest the feasibility of AI-based image-domain material decomposition in a conventional SECT system without a DECT scanner.


Asunto(s)
Inteligencia Artificial , Neoplasias de Cabeza y Cuello , Humanos , Tomografía Computarizada por Rayos X/métodos , Cintigrafía , Dosis de Radiación , Neoplasias de Cabeza y Cuello/diagnóstico por imagen
13.
Cancer Diagn Progn ; 4(1): 46-50, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38173668

RESUMEN

Background/Aim: This study investigated the survival outcomes of patients with head and neck squamous cell carcinoma (HNSCC) undergoing palliative radiotherapy, particularly focusing on challenges and factors associated with older age, providing insights into appropriate palliative radiotherapy use in this demographic. Patients and Methods: A retrospective study was conducted using electronic medical records of 73 patients with HNSCC who were deemed unsuitable for curative therapy. Palliative radiotherapy involved a uniform dose of 30 Gy in 10 fractions. Survival analysis was performed using Kaplan-Meier method, and multivariate analysis identified significant prognostic factors. Results: The median overall survival was 7.5 months, with no significant difference between age groups. Karnofsky performance status (KPS) >70 correlated with favorable survival. Multivariate analysis confirmed KPS as an independent prognostic factor (hazard ratio=1.949, p=0.031). Conclusion: The results of this study align with those of previous studies, emphasizing the importance of palliative radiotherapy for HNSCC treatment. Optimal dose fractionation regimens remain undetermined, and tailored approaches that consider factors, such as age and performance status are crucial. Individualized, comprehensive assessments and supportive care measures enhance patient well-being, reflecting palliative care principles.

14.
Strahlenther Onkol ; 200(1): 39-48, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37591978

RESUMEN

PURPOSE: The geometric distortion related to magnetic resonance (MR) imaging in a diagnostic radiology (MRDR) and radiotherapy (MRRT) setup is evaluated, and the dosimetric impact of MR distortion on fractionated stereotactic radiotherapy (FSRT) in patients with brain metastases is simulated. MATERIALS AND METHODS: An anthropomorphic skull phantom was scanned using a 1.5­T MR scanner, and the magnitude of MR distortion was calculated with (MRDR-DC and MRRT-DC) and without (MRDR-nDC and MRRT-nDC) distortion-correction algorithms. Automated noncoplanar volumetric modulated arc therapy (HyperArc, HA; Varian Medical Systems, Palo Alto, CA, USA) plans were generated for 53 patients with 186 brain metastases. The MR distortion at each gross tumor volume (GTV) was calculated using the distance between the center of the GTV and the MR image isocenter (MIC) and the quadratic regression curve derived from the phantom study (MRRT-DC and MRRT-nDC). Subsequently, the radiation isocenter of the HA plans was shifted according to the MR distortion at each GTV (HADC and HAnDC). RESULTS: The median MR distortions were approximately 0.1 mm when the distance from the MIC was < 30 mm, whereas the median distortion varied widely when the distance was > 60 mm (0.23, 0.47, 0.37, and 0.57 mm in MRDR-DC, MRDR-nDC, MRRT-DC, and MRRT-nDC, respectively). The dose to the 98% of the GTV volume (D98%) decreased as the distance from the MIC increased. In the HADC plans, the relative dose difference of D98% was less than 5% when the GTV was located within 70 mm from the MIC, whereas the underdose of GTV exceeded 5% when it was 48 mm (-26.5% at maximum) away from the MIC in the HAnDC plans. CONCLUSION: Use of a distortion-correction algorithm in the studied MR diagnoses is essential, and the dosimetric impact of MR distortion is not negligible, particularly for tumors located far away from the MIC.


Asunto(s)
Neoplasias Encefálicas , Radiocirugia , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Radiocirugia/métodos , Algoritmos , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/secundario , Imagen por Resonancia Magnética/métodos , Dosificación Radioterapéutica
15.
Cureus ; 15(11): e48188, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38054156

RESUMEN

In liver stereotactic body radiotherapy (SBRT), precise image guidance is paramount, serving as the foundation of this treatment approach. The accuracy of SBRT in liver cancer treatment heavily relies on meticulous imaging techniques. The diaphragm, situated adjacent to the liver, is a crucial anatomical structure susceptible to positional and motion variations, which can potentially impact the accuracy of liver tumor targeting. This study explores the application of real-time kilovoltage projection streaming images (KVPSI) in comparison to digitally reconstructed radiography (DRR) for assessing diaphragm position deviations during breath-hold liver tumor SBRT. A 76-year-old male diagnosed with cholangiocarcinoma underwent breath-hold SBRT using split arc volumetric modulated arc therapy (VMAT), where a full arc was split into six sub-arcs, each spanning 60 degrees. The diaphragm dome positions were continuously monitored through KVPSI during treatment. The intrafractional position deviations of the diaphragm were calculated and analyzed for each split arc. The case report revealed a mean diaphragm dome deviation of 0.47 mm (standard deviation: 4.47 mm) in the entire arc. This pioneering study showcases the feasibility of intrafractional diaphragm position variation assessment using real-time KVPSI during the breath-hold liver tumor VMAT-SBRT. Integrating real-time imaging techniques enhances our comprehension of the intra-breath-hold variations, thereby guiding adaptive treatment strategies and potentially improving treatment outcomes. Clinical validation through further research is essential.

16.
Cureus ; 15(10): e46523, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37927675

RESUMEN

BACKGROUND: Esthesioneuroblastoma (ENB), a rare malignancy arising from the olfactory epithelium, poses clinical challenges owing to its propensity for local invasion and recurrence. Its management typically involves surgical resection and adjuvant radiotherapy. However, debate persists regarding the optimal treatment strategy, particularly the use of elective nodal irradiation (ENI). This study aimed to investigate recurrence patterns in patients with localized ENB treated with surgery and adjuvant radiotherapy without ENI. METHODS: Our retrospective analysis included patients who underwent surgery followed by adjuvant radiotherapy for treatment of ENB between January 2011 and November 2022. Patients with incomplete data or who had received neoadjuvant radiotherapy were excluded. Patient characteristics, radiotherapy data (type, dose, and duration), and follow-up data were collected. Recurrence patterns were evaluated, and overall survival (OS), disease-free survival (DFS), and local control rates were determined using the Kaplan-Meier method. RESULTS: Twelve patients with ENB (median age, 56 years) were included. Most had stage C disease. The median radiation dose was 60 Gy, and the median treatment duration was six weeks. Only one death was confirmed during the observation period, and the five-year DFS rates were 64.3%. Local control was achieved in 11 patients, with only one experiencing local recurrence. Regional lymph node recurrence occurred in three patients and was successfully managed via neck dissection. The timing of recurrence varied, emphasizing the importance of long-term surveillance. CONCLUSION: Adjuvant radiotherapy without ENI is a viable treatment option for ENB, resulting in favorable local control and OS outcomes. Regional lymph node metastases were observed but effectively managed via salvage therapy. Prospective studies with larger cohorts are warranted to confirm the effectiveness of this treatment strategy and to define optimal radiotherapy fields.

17.
Cancer Diagn Progn ; 3(6): 721-725, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37927804

RESUMEN

Background/Aim: Palliative radiotherapy is a critical component of cancer care aimed at symptom management and enhancing the quality of life of patients with advanced cancer. Balancing symptom relief and potential risks is pivotal in clinical decision-making. This study explored the 30-day mortality (30-DM) rate after palliative radiotherapy in a single-center setting to shed light on potential prognostic factors and safety considerations. Patients and Methods: This retrospective cohort study included patients who underwent palliative radiotherapy for various indications between March 2020 and February 2023. Data were retrieved from electronic medical records and analyzed according to ethical guidelines. The primary outcome measure was 30-DM rate, and multivariate logistic regression analysis was conducted to identify the independent predictors of 30-DM. Results: A total of 931 palliative radiotherapy sessions were administered to 601 patients, with a median of one session per patient. The cohort had a median age of 70 years, predominantly men (58%), and featured diverse primary cancer types, with lung cancer being the most prevalent (15.8%). The 30-DM rate was 12.9%. Multivariate analysis identified Karnofsky Performance Status (KPS) as the sole independent prognostic factor significantly associated with 30-DM. Conclusion: This study provides valuable insights into 30-DM rates following palliative radiotherapy. Future research should focus on prospective multicenter investigations with larger cohorts and comprehensive data collection, ultimately leading to improved risk prediction models for personalized treatment decisions in palliative radiotherapy.

18.
J Radiat Res ; 64(6): 940-947, 2023 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-37839063

RESUMEN

To explore predictors of the histopathological response to preoperative chemoradiotherapy (CRT) in patients with pancreatic cancer (PC) using dual-energy computed tomography-reconstructed images. This retrospective study divided 40 patients who had undergone preoperative CRT (50-60 Gy in 25 fractions) followed by surgical resection into two groups: the response group (Grades II, III and IV, evaluated from surgical specimens) and the nonresponse group (Grades Ia and Ib). The computed tomography number [in Hounsfield units (HUs)] and iodine concentration (IC) were measured at the locations of the aorta, PC and pancreatic parenchyma (PP) in the contrast-enhanced 4D dual-energy computed tomography images. Logistic regression analysis was performed to identify predictors of histopathological response. Univariate analysis did not reveal a significant relation between any parameter and patient characteristics or dosimetric parameters of the treatment plan. The HU and IC values in PP and the differences in HU and IC between the PP and PC (ΔHU and ΔIC, respectively) were significant predictors for distinguishing the response (n = 24) and nonresponse (n = 16) groups (P < 0.05). The IC in PP and ΔIC had a higher area under curve values [0.797 (95% confidence interval, 0.659-0.935) and 0.789 (0.650-0.928), respectively] than HU in PP and ΔHU [0.734 (0.580-0.889) and 0.721 (0.562-0.881), respectively]. The IC value could potentially be used for predicting the histopathological response in patients who have undergone preoperative CRT.


Asunto(s)
Yodo , Neoplasias Pancreáticas , Humanos , Estudios Retrospectivos , Medios de Contraste , Tomografía Computarizada por Rayos X/métodos , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/terapia , Quimioradioterapia/métodos , Neoplasias Pancreáticas
19.
J Radiat Res ; 64(4): 644-650, 2023 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-37280131

RESUMEN

In volumetric modulated arc therapy (VMAT), the effect of an increase in skin surface dose due to topical agents might be negligible. We investigated the bolus effects of three types of topical agents in VMAT for head and neck cancer (HNC). Topical agents of different thicknesses (0.1, 0.5 and 2 mm) were prepared. When each topical agent was set, the surface doses were measured for the anterior static field and VMAT, with and without a thermoplastic mask. No significant differences were observed among the three topical agents. For topical agent thicknesses of 0.1, 0.5 and 2 mm, the increases in surface dose for the anterior static field without the thermoplastic mask were 7-9, 30-31 and 81-84%, respectively. With the thermoplastic mask, the corresponding increases were 5, 12-15 and 41-43%, respectively. The increases in surface dose for VMAT without the thermoplastic mask were 5-8, 16-19 and 36-39%, respectively, and those with the thermoplastic mask were 4, 7-10 and 15-19%, respectively. The rate of increase in surface dose with the thermoplastic mask was smaller than that without the thermoplastic mask. The increase in surface dose with topical agents of clinical standard thickness (0.02 mm) was estimated to be 2% with the thermoplastic mask. The increase in surface dose with topical agents in dosimetric simulation, compared with control situation, is not significant in clinical conditions for HNC patients.


Asunto(s)
Neoplasias de Cabeza y Cuello , Radioterapia de Intensidad Modulada , Humanos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Neoplasias de Cabeza y Cuello/radioterapia , Radiometría
20.
Anticancer Res ; 43(7): 3079-3087, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37351970

RESUMEN

BACKGROUND/AIM: Angiosarcoma of the scalp (AS) is a rare tumor that has often been treated by total scalp irradiation (TSI). TSI has technical and dosimetric challenges. This study aimed to compare the dosimetric performance of helical tomotherapy (HT) plans with that of HyperArc (HA) plans for TSI in AS. PATIENTS AND METHODS: A planning study was conducted for 11 patients with AS (70 Gy/35 fr). HT and HA planning was performed using TomoHDA and TrueBeam Edge systems, respectively. The performance of three different plans were compared: HT, HA, and HA with half-field beams (HF-HA). The dose distribution and dosimetric parameters for each plan were evaluated. RESULTS: All constraint parameters for the target and organs at risk (OARs) met the goals within acceptable limits for the three techniques. The HA and HF-HA plans provided significantly lower mean brain dose (12.46±2.48 Gy and 8.02±1.48 Gy) than did the HT plan (17.59±3.47 Gy). The doses receiving 0.1 cc of the volume for brainstem and chiasm were significantly lower in the HA and HF-HA plans than those in the HT plan. The HA and HF-HA plans provided a shorter beam-on time (155±3 s and 181±14 s) than did the HT plan (962±221 s). CONCLUSION: The HA plan provided significantly better OARs sparing than the HT plan for TSI in AS and had an advantage to using half-field beams.


Asunto(s)
Hemangiosarcoma , Radioterapia de Intensidad Modulada , Humanos , Radioterapia de Intensidad Modulada/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Dosificación Radioterapéutica , Cuero Cabelludo , Hemangiosarcoma/radioterapia , Órganos en Riesgo/efectos de la radiación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...