1.
In Vivo ; 36(1): 330-335, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34972730

RESUMEN

BACKGROUND/AIM: Stereotactic radiotherapy (SRT) for spine metastases with helical tomotherapy requires a long irradiation time due to the high dose per fraction. Since helical tomotherapy can neither confirm nor correct the position during irradiation, a plan with a long irradiation time cannot be used in actual clinical practice, given the intra-fractional motion error. To address this problem, we devised a method called REPEAT irradiation. PATIENTS AND METHODS: REPEtitive pAinTing (REPEAT) irradiation is a method of dividing the irradiation for a given fraction per day into several sessions and performing the irradiation after position correction using mega-voltage computed tomography images for each session. In order to evaluate how REPEAT irradiation changes irradiation time and the dose-volume histogram (DVH), a planning study with helical tomotherapy was conducted using CT images of a patient with lumbar spine metastasis. RESULTS: In this case, we found that dividing 3 irradiation fractions into 3 sessions per day (i.e., 9 fractions=9 sessions in 3 days) using REPEAT irradiation shortened the irradiation time per session and simultaneously improved dose-volume histogram parameters. CONCLUSION: Although the optimal number of sessions may differ depending on the patient's condition, the fixing method, the irradiation site, and the calculation parameters, REPEAT irradiation does not require any special equipment and is a simple practical treatment method.


Asunto(s)
Radiocirugia , Radioterapia de Intensidad Modulada , Fraccionamiento de la Dosis de Radiación , Humanos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador
2.
In Vivo ; 35(4): 2433-2437, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34182527

RESUMEN

BACKGROUND/AIM: Positional uncertainty in spinal stereotactic body radiotherapy (SBRT) may cause fatal error, therefore, we investigated the intra-fractional spinal motion during SBRT and its time dependency. PATIENTS AND METHODS: Thirty-one patients who received SBRT using CyberKnife were enrolled in the study. 2D kV X-ray spine images in two directions were taken before and during treatment. Image acquisition intervals during treatment were set at 35-60 sec. Automatic image matchings were performed between the reference digital reconstructed radiography (DRR) and live images, and the spinal position displacements were logged in six translational and rotational directions. If the displacements exceeded 2 mm or 1 degree, the treatment beam delivery was interrupted and the patient position was corrected by moving couch, and the couch adjustments were also logged. Based on the information, the time-dependent accumulated translational and rotational displacements without any couch adjustments were calculated. RESULTS: Spinal position displacements in all translational and rotational directions were correlated with elapsed treatment time. Especially, Right-Left displacements of >1 mm and >2 mm were observed at 4-6 and 8-10 min after treatment initiation, respectively. Rotational displacements in the Yaw direction >1° were observed at 10-15 min after treatment initiation. CONCLUSION: The translational and rotational displacements systematically increased with elapsed treatment time. It is suggested that the spine position should be checked at least every 4-6 min or the treatment time should be limited within 4-6 minutes to ensure the irradiation accuracy within the millimeter or submillimeter range.


Asunto(s)
Radiocirugia , Tomografía Computarizada de Haz Cónico , Humanos , Movimiento , Planificación de la Radioterapia Asistida por Computador , Columna Vertebral/diagnóstico por imagen , Columna Vertebral/cirugía