Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sensors (Basel) ; 24(10)2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38793828

RESUMEN

After the Fukushima nuclear power plant accident in 2011, many types of survey meters were used, including Geiger-Müller (GM) survey meters, which have long been used to measure ß-rays. Recently, however, a novel radiation survey meter that uses a plastic-scintillation sensor has been developed. Although manufacturers' catalog data are available for these survey meters, there have been no user reports on performance. In addition, the performance of commercial plastic-scintillation survey meters has not been evaluated. In this study, we experimentally compared the performance of a plastic-scintillation survey meter with that of a GM survey meter. The results show that the two instruments performed very similarly in most respects. The GM survey meter exhibited count losses when the radiation count rate was high, whereas the plastic-scintillation survey meter remained accurate under such circumstances, with almost no count loss at high radiation rates. For measurements at background rates (i.e., low counting rates), the counting rates of the plastic-scintillation and GM survey meters were similar. Therefore, an advantage of plastic-scintillation survey meters is that they are less affected by count loss than GM survey meters. We conclude that the plastic-scintillation survey meter is a useful ß-ray measuring/monitoring instrument.

2.
J Radiol Prot ; 44(2)2024 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-38701771

RESUMEN

Given the new recommendations for occupational eye lens doses, various lead glasses have been used to reduce irradiation of interventional radiologists. However, the protection afforded by lead glasses over prescription glasses (thus over-glasses-type eyewear) has not been considered in detail. We used a phantom to compare the protective effects of such eyewear and regular eyewear of 0.07 mm lead-equivalent thickness. The shielding rates behind the eyewear and on the surface of the left eye of an anthropomorphic phantom were calculated. The left eye of the phantom was irradiated at various angles and the shielding effects were evaluated. We measured the radiation dose to the left side of the phantom using RPLDs attached to the left eye and to the surface/back of the left eyewear. Over-glasses-type eyewear afforded good protection against x-rays from the left and below; the average shielding rates on the surface of the left eye ranged from 0.70-0.72. In clinical settings, scattered radiation is incident on physicians' eyes from the left and below, and through any gap in lead glasses. Over-glasses-type eyewear afforded better protection than regular eyewear of the same lead-equivalent thickness at the irradiation angles of concern in clinical settings. Although clinical evaluation is needed, we suggest over-glasses-type Pb eyewear even for physicians who do not wear prescription glasses.


Asunto(s)
Dispositivos de Protección de los Ojos , Anteojos , Exposición Profesional , Dosis de Radiación , Protección Radiológica , Humanos , Exposición Profesional/prevención & control , Exposición Profesional/análisis , Fantasmas de Imagen , Ojo/efectos de la radiación , Traumatismos por Radiación/prevención & control
3.
J Radiat Res ; 2024 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-38818635

RESUMEN

We quantified the level of backscatter radiation generated from physicians' heads using a phantom. We also evaluated the shielding rate of the protective eyewear and optimal placement of the eye-dedicated dosimeter (skin surface or behind the Pb-eyewear). We performed diagnostic X-rays of two head phantoms: Styrofoam (negligible backscatter radiation) and anthropomorphic (included backscatter radiation). Radiophotoluminescence glass dosimeters were used to measure the eye-lens dose, with or without 0.07-mm Pb-equivalent protective eyewear. We used tube voltages of 50, 65 and 80 kV because the scattered radiation has a lower mean energy than the primary X-ray beam. The backscatter radiation accounted for 17.3-22.3% of the eye-lens dose, with the percentage increasing with increasing tube voltage. Furthermore, the shielding rate of the protective eyewear was overestimated, and the eye-lens dose was underestimated when the eye-dedicated dosimeter was placed behind the protective eyewear. We quantified the backscatter radiation generated from physicians' heads. To account for the effect of backscatter radiation, an anthropomorphic, rather than Styrofoam, phantom should be used. Close contact of the dosimeter with the skin surface is essential for accurate evaluation of backscatter radiation from physician's own heads. To assess the eye-lens dose accurately, the dosimeter should be placed near the eye. If the dosimeter is placed behind the lens of the protective eyewear, we recommend using a backscatter radiation calibration factor of 1.2-1.3.

4.
Bioorg Med Chem ; 99: 117585, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38219557

RESUMEN

The T cell immunoreceptor with immunoglobulin and immunoreceptor tyrosine-based inhibitory motif domain (TIGIT) is an inhibitory immunoreceptor expressed on lymphocytes that serves as a promising target for cancer immunotherapy. In this study, facile synthetic protocols to produce the extracellular domain of TIGIT were investigated for applications of TIGIT in mirror-image screening. During the synthesis via sequential native chemical ligations, we encountered problems with significantly poor solubility of the ligated products. Introducing trityl-type solubilizing auxiliaries, which also functioned as temporary protecting groups for cysteine residues, facilitated a flexible order of ligations and efficient purification protocols. After refolding under appropriate conditions, the synthetic TIGIT showed a sufficient affinity toward its target ligand CD155.


Asunto(s)
Inmunoglobulinas , Linfocitos T , Receptores Inmunológicos , Inmunoterapia , Tirosina
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...