Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Medicine (Baltimore) ; 99(3): e18773, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32011469

RESUMEN

Cervical epidural anesthesia (CEA) is generally not used during upper-arm vascular surgery for hemodialysis in end-stage renal disease (ESRD) patients, despite its advantages. The Quality of Recovery-40 questionnaire (QOR-40) has been validated as a tool for assessing the degree of recovery after surgery. We hypothesized that CEA could provide a better outcome on the QOR-40 than general anesthesia after upper-arm vascular surgery for hemodialysis in ESRD patients.We divided anesthetic methods into general anesthesia and CEA. The QOR-40 was administered to 70 patients on the night before surgery and at 24 hours after surgery. Additional data, including consumption of opioid analgesics, occurrence of postoperative nausea and vomiting, and scores on a numeric rating scale (NRS) were collected.The total QOR-40 scores of the two groups differed significantly (P = .024) on postoperative day 1. Opioid consumption (P = .005) and occurrence of postoperative nausea (P = .019) in the post-anesthesia care unit (PACU) were significantly lower in the CEA group, whose NRS scores were significantly lower in the PACU (P < .001) and at postoperative day 1 (P = .016).Assessment of postoperative quality of recovery after upper-arm vascular surgery in ESRD patients showed that the CEA group had significantly better total QOR-40 and NRS scores. CEA could be used as an alternative anesthetic technique for upper-arm vascular surgery for hemodialysis in ESRD patients to improve the quality of recovery.


Asunto(s)
Periodo de Recuperación de la Anestesia , Anestesia Epidural/métodos , Anestesia General/métodos , Brazo/irrigación sanguínea , Brazo/cirugía , Derivación Arteriovenosa Quirúrgica , Fallo Renal Crónico/terapia , Diálisis Renal , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Encuestas y Cuestionarios
2.
Korean J Anesthesiol ; 65(5): 385-96, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24363840

RESUMEN

BACKGROUND: The aims of this study were to compare the stability, correlation with end-tidal sevoflurane, and area below the effect (AUCeffect) vs. time curves of temporal linear mode complexity (TLMC) and approximate entropy (ApEn) during sevoflurane anesthesia. Another study goal was to characterize the time course of the effects of sevoflurane. METHODS: Electroencephalogram (EEG) parame1ter stability was evaluated using the coefficients of variation (CV) of the median baseline (E0 ), maximal (Emax ), and individual median E0 - Emax values. Correlations between sevoflurane concentration and EEG parameters were tested. AUCeffect vs. time curves of TLMC and ApEn were calculated to quantitate any decrease in central nervous system activities. A sigmoid Emax model was used for pharmacodynamic modeling. RESULTS: TLMC and ApEn demonstrated CVs of 8.36 and 7.35 (for E0 ) and 19.61 and 13.45 (Emax ), respectively. The CVs of the individual median E0 - Emax values were 65.16 for TLMC and 59.97 for ApEn. The Spearman correlation coefficient was -0.3103 for TLMC and -0.3410 for ApEn (P < 0.001 for both parameters). The median AUCeffect value was 338.9 for TLMC and 246.5 for ApEn (P = 0.457). The final pharmacodynamic parameters estimated by sigmoid Emax models were described as follows; E0 : 0.614, 0.617, Emax : 0.334, 0.287, Ce50 : 5.48, 5.07 vol%, γ: 1.88, 2.01, ke0 : 0.306, 0.236 min (TLMC, ApEn). CONCLUSIONS: TLMC is comparable to ApEn according to the univariate EEG descriptors of the effects of sevoflurane. A sigmoid Emax model well described the pharmacodynamics of sevoflurane for TLMC and ApEn.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...