Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 98
Filtrar
3.
Eur Heart J Open ; 4(2): oeae018, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38529170

RESUMEN

Aims: Current evidence on the prognostic value of exercise stress echocardiography (ESE) in asymptomatic patients with low-gradient severe aortic stenosis (AS) is limited. Therefore, this study aimed to elucidate its prognostic implications for patients with low-gradient severe AS and determine the added value of ESE in risk stratification for this population. Methods and results: This retrospective observational study included 122 consecutive asymptomatic patients with either moderate [mean pressure gradient (MPG) < 40 mmHg and aortic valve area (AVA) 1.0-1.5 cm2] or low-gradient severe (MPG < 40 mmHg and AVA < 1.0 cm2) AS and preserved left ventricular ejection fraction (≥50%) who underwent ESE. All patients were followed up for AS-related events. Of 143 patients, 21 who met any exclusion criteria, including early interventions, were excluded, and 122 conservatively managed patients [76.5 (71.0-80.3) years; 48.3% male] were included in this study. During a median follow-up period of 989 (578-1571) days, 64 patients experienced AS-related events. Patients with low-gradient severe AS had significantly lower event-free survival rates than those with moderate AS (log-rank test, P < 0.001). Multivariable Cox regression analysis showed that the mitral E/e' ratio during exercise was independently associated with AS-related events (hazard ratio = 1.075, P < 0.001) in patients with low-gradient severe AS. Conclusion: This study suggests that asymptomatic patients with low-gradient severe AS have worse prognoses than those with moderate AS. Additionally, the mitral E/e' ratio during exercise is a useful parameter for risk stratification in patients with low-gradient severe AS.

4.
Circ J ; 88(4): 510-516, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-37438144

RESUMEN

BACKGROUND: Renal congestion is a potential prognostic factor in patients with heart failure and recently, assessment has become possible with intrarenal Doppler ultrasonography (IRD). The association between renal congestion assessed by IRD and outcomes after mitral transcatheter edge-to-edge repair (TEER) is unknown, so we aimed to clarify renal congestion and its prognostic implications in patients with mitral regurgitation (MR) who underwent TEER using MitraClip system.Methods and Results: Patients with secondary MR who underwent TEER and were assessed for intrarenal venous flow (IRVF) by IRD were classified according to their IRVF pattern as continuous or discontinuous. Of the 105 patients included, 78 patients (74%) formed the continuous group and 27 (26%) were the discontinuous group. Kaplan-Meier analysis revealed significant prognostic power of the IRVF pattern for predicting the composite outcome of all-cause death and heart failure rehospitalization (log-rank P=0.0257). On multivariate Cox regression analysis, the composite endpoint was independently associated with the discontinuous IRVF pattern (hazard ratio, 3.240; 95% confidence interval, 1.300-8.076; P=0.012) adjusted using inverse probability of treatment weighting. CONCLUSIONS: IRVF patterns strongly correlated with clinical outcomes without changes in renal function. Thus, they may be useful for risk stratification after mitral TEER for patients with secondary MR.


Asunto(s)
Insuficiencia Cardíaca , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Angiografía , Insuficiencia Cardíaca/diagnóstico por imagen , Estimación de Kaplan-Meier , Riñón/diagnóstico por imagen , Resultado del Tratamiento
5.
Cardiovasc Revasc Med ; 58: 68-76, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37500393

RESUMEN

BACKGROUND: Aortic stenosis (AS) and chronic kidney disease (CKD) can coexist. Repeat exposure to contrast media in patients undergoing transcatheter aortic valve implantation (TAVI) has latent mortality risks and increased risk for acute kidney injury. We aimed to assess our "zero-contrast TAVI" protocol for patients with advanced CKD. METHODS: Consecutive patients with severe AS who underwent TAVI at a single center registry were enrolled. Zero-contrast TAVI group included patients who underwent TAVI without contrast and who had an estimated glomerular filtration rate <30 mL/min/1.73 m2. Conventional TAVI group included patients who underwent the regular TAVI procedure. Patients using balloon-expandable valves via transfemoral approach were analyzed. Baseline clinical and procedural characteristics and clinical outcomes were compared between two groups. The primary outcome was early safety as defined by Valve Academic Research Consortium Criteria. Secondary outcomes included the presence of severe prosthesis-patient mismatch, moderate or greater perivalvular leakage, and requirement for new dialysis (within 3 months). RESULTS: A total of 520 patients were analyzed. Among these, 32 (6 %) underwent zero-contrast TAVI and 488 (94 %) conventional TAVI. In the zero-contrast TAVI group, 12 patients (37.5 %) had to use 20.7 (11.0-31.2) mL of contrast media. There were no significant differences in the primary and secondary outcomes between zero-contrast TAVI and conventional TAVI groups (78.1 % vs. 86.8 %, P = 0.184 and 9.4 % vs. 8.1 %, P = 0.738 for the primary and secondary outcomes, respectively). CONCLUSIONS: Zero-contrast TAVI is feasible, safe, and effective in patients with AS and stage 4 CKD.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Insuficiencia Renal Crónica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estudios de Factibilidad , Medios de Contraste/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Insuficiencia Renal Crónica/complicaciones , Insuficiencia Renal Crónica/diagnóstico , Insuficiencia Renal Crónica/terapia , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Resultado del Tratamiento
6.
Circ J ; 88(4): 531-538, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38008428

RESUMEN

BACKGROUND: The MitraClip G4 system is a new iteration of the transcatheter edge-to-edge repair system. We assessed the impact of the G4 system on routine practice and outcomes in secondary mitral regurgitation (2°MR).Methods and Results: Consecutive patients with 2°MR treated with either the MitraClip G2 (n=89) or G4 (n=63) system between 2018 and 2021 were included. Baseline characteristics, procedures, and outcomes were compared. Inverse probability of treatment weighting and Cox regression were used to adjust for baseline differences. Baseline characteristics were similar, except for a lower surgical risk in the G4 group (Society of Thoracic Surgeons Predicted Risk of Mortality ≥8: 38.1% vs. 56.2%; P=0.03). In the G4 group, more patients had short (≤2 mm) coaptation length (83.7% vs. 54.0%; P<0.001) and fewer clips were used (17.5% vs. 36.0%; P=0.02). Acceptable MR reduction was observed in nearly all patients, with no difference between the G4 and G2 groups (100% vs. 97.8%, respectively; P=0.51). The G4 group had fewer patients with high transmitral gradients (>5mmHg; 3.3% vs. 13.6%; P=0.03). At 1 year, there was no significant difference between groups in the composite endpoint (death or heart failure rehospitalization) after baseline adjustment (10.5% vs. 20.2%; hazard ratio 0.39; 95% confidence interval 0.11-1.32; P=0.13). CONCLUSIONS: The G4 system achieved comparable device outcomes to the early-generation G2, despite treating more challenging 2°MR with fewer clips.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Resultado del Tratamiento , Modelos de Riesgos Proporcionales , Cateterismo Cardíaco
7.
Cardiovasc Interv Ther ; 39(1): 74-82, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37938532

RESUMEN

The safety and feasibility are still not well known for exercise-induced mitral regurgitation (MR). This study is aimed to assess and compare the hemodynamic and symptomatic changes in patients with significant secondary MR during exercise stress echocardiography (ESE) before and after transcatheter edge-to-edge repair (TEER). The study included a total of 15 patients with secondary MR who underwent ESE before and after TEER using the MitraClip system (Abbott, Abbott Park, IL, USA). Echocardiographic data of ESE were collected both before the procedure and during the follow-up visit at 3 months. During the one-year postoperative observation period, the rate of readmission due to heart failure was 13% (n = 2), with no recorded fatalities. Although no significant differences of ESE data were observed in exercise-induced pulmonary hypertension or cardiac output before and after the repair, the severity of MR was significantly improved after the procedure, both at rest (2 [2-3] vs. 1 [1-2], p = 0.0125) and during ESE (3 [3-3] vs. 1 [1-1], p < 0.0001). Furthermore, the New York Heart Association Functional Classification was improved (3 [3-3] vs. 1 [1-1], p < 0.0001) after treatment. For a supplemental analysis, MR during ESE was significantly improved not only in cases with atrial secondary MR but also in ventricular secondary MR. Transcatheter edge-to-edge repair for exercise-induced MR resulted in a significant improvement in postoperative MR severity and subjective symptoms. These results are novel, as they have not been extensively reported previously, particularly among Japanese patients.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Ecocardiografía de Estrés , Resultado del Tratamiento , Insuficiencia de la Válvula Mitral/diagnóstico , Insuficiencia de la Válvula Mitral/cirugía , Ecocardiografía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cateterismo Cardíaco
9.
Am J Cardiol ; 213: 140-145, 2024 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-38134979

RESUMEN

Transcatheter aortic valve replacement (TAVR) has emerged as a successful treatment option for severe aortic stenosis. However, the long-term outcomes of TAVR in nonagenarians is lacking. We aimed to examine the long-term mortality and quality of life in nonagenarians after TAVR. This is a multicenter, retrospective analysis on patients with severe aortic stenosis who underwent TAVR. Patients were divided into 2 groups: nonagenarians (age ≥90 years) and age <90 years. The Kansas City cardiomyopathy questionnaire (KCCQ) and New York Heart Association (NYHA) scores were compared before and after TAVR. All-cause mortality was compared between both groups at 30 days, 1 year, and 5 years after TAVR using the Cox proportional hazard model. A total of 6,896 patients were included, of whom 591 were nonagenarians. Nonagenarians had a higher Society of Thoracic Surgeons perioperative risk of mortality (8.1 ± 4.6% vs 5.4 ± 4.2%, p <0.001) before TAVR. Both groups were similar in KCCQ and NYHA scores at baseline. At 1 year after TAVR, there was no significant difference in improvement in the KCCQ overall score between those aged <90 years and nonagenarians (-4.76, 95% confidence interval [CI] -11.4 to 1.9, p = 0.161). Similarly, there was no statistically significant difference in improvement in NYHA class between the 2 groups at 1 year (odds ratio 1.07, 95% CI 0.85 to 1.25), p = 0.526). The unadjusted 30-day (3.2% vs 2.7%, hazard ratio 1.11, 95% CI 0.70 to 1.80, p = 0.667) and 5-year (28.0% vs 26.6%, hazard ratio 1.05, 95% CI 0.89 to 1.24, p = 0.60) all-cause mortality were similar between the 2 groups. In conclusion, this study demonstrates an excellent long-term mortality rate at 5 years after TAVR in nonagenarians, comparable to patients younger than 90 years. There is a significant and enduring improvement in functional status in nonagenarians, observed up to 1 year after TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Humanos , Calidad de Vida , Nonagenarios , Resultado del Tratamiento , Estudios Retrospectivos , Válvula Aórtica/cirugía , Factores de Riesgo
10.
Am J Cardiol ; 210: 259-265, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37875233

RESUMEN

Aortic stenosis is a prevalent valvular heart disease, especially in the older people. They often coexist with other co-morbidities, and noncardiac surgery carries a higher risk because of the underlying valve condition. Despite the growing concern about the safety and optimal management of noncardiac surgery post-transcatheter aortic valve replacement (TAVR), there is limited evidence on this matter. This study aims to assess the clinical outcomes of noncardiac surgeries after TAVR. This retrospective study included 718 patients who underwent TAVR. Of these, 36 patients underwent noncardiac surgery after TAVR. The primary end point was the incidence of cardiovascular adverse events post-TAVR and the secondary end point was the incidence of structural valve deterioration. Composite end points included disabling stroke, heart failure requiring hospitalization, and cardiac death as defined by Valve Academic Research Consortium 3. Most of these surgeries were orthopedic and classified as intermediate risk. All noncardiac surgeries were performed without perioperative adverse events. There was no observed structural valve deterioration, and the incidence of composite end points did not significantly differ between the surgical and nonsurgical groups during the follow-up period. Noncardiac surgery after TAVR can be performed safely and does not have a negative impact on prognosis. Further studies are warranted to determine the optimal strategy for noncardiac surgery after TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estudios Retrospectivos , Prevalencia , Factores de Riesgo , Estenosis de la Válvula Aórtica/epidemiología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Resultado del Tratamiento , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos
11.
Circ Rep ; 5(12): 442-449, 2023 Dec 08.
Artículo en Inglés | MEDLINE | ID: mdl-38073869

RESUMEN

Background: A high score for controlling nutritional status (CONUT) due to poor nutritional status has been associated with adverse outcomes in patients with chronic heart failure. However, because little is known about the effect of CONUT score on mortality rates after transcatheter mitral valve repair, we evaluated nutrition screening tools for prognosis prediction in patients undergoing transcatheter mitral valve repair using the MitraClipTM system. Methods and Results: We retrospectively analyzed 148 patients with severe mitral regurgitation (MR) who underwent MitraClipTM implantation between April 2018 and April 2021. The preprocedural CONUT scores were assessed at the time of hospitalization, the primary outcome was all-cause death, and the analysis was of the mortality and incidence rates of cardiac events 1 year post-operation. Functional MR was of ischemic origin in the majority of patients (69.6%), with a mean left ventricular ejection fraction of 48.9±15.8%. Kaplan-Meier curves indicated that all-cause death was significantly worse in the high-CONUT score group than in the low-CONUT score group. Cox hazard analysis showed a significant association between all-cause death and CONUT score, as well as MitraScore. Conclusions: Preprocedural CONUT score, as well as MitraScore, in patients undergoing transcatheter edge-to-edge mitral valve repair may predict an increased risk of all-cause death. This knowledge should allow the heart team to accurately assess the clinical implications and prognostic benefits of the procedure in individual patients.

12.
JACC Cardiovasc Interv ; 16(24): 2986-2996, 2023 Dec 25.
Artículo en Inglés | MEDLINE | ID: mdl-38151313

RESUMEN

BACKGROUND: Stroke after transcatheter aortic valve replacement (TAVR) is associated with considerable morbidity and mortality. Predictors of stroke and the long-term risk after TAVR remain incompletely understood. OBJECTIVES: The authors sought to investigate the short- and long-term incidence and predictors of stroke after TAVR in the SwissTAVI Registry. METHODS: Between February 2011 and June 2021, consecutive patients undergoing TAVR were included. Standardized stroke ratios (SSRs) were calculated to compare trends in stroke of TAVR patients with an age- and sex-matched general population in Switzerland derived from the 2019 Global Burden of Disease study. RESULTS: A total of 11,957 patients (81.8 ± 6.5 years of age, 48.0% female) were included. One-third of the patients (32.3%) had a history of atrial fibrillation, and 11.8% had a history of cerebrovascular accident. The cumulative 30-day incidence rate of stroke was 3.0%, with 69% of stroke events occurring within the first 48 hours after TAVR. The incidence of stroke was 4.3% at 1 year, and 7.8% at 5 years. Compared with an age- and sex-adjusted general population, the risk of stroke was significantly higher in the TAVR population during the first 2 years after TAVR: first year: SSR 7.26 (95% CI: 6.3-8.36) and 6.82 (95% CI: 5.97-7.79) for males and females, respectively; second year: SSR 1.98 (95% CI: 1.47-2.67) and 1.48 (95% CI: 1.09-2.02) for males and females, respectively; but returned to a comparable level to that observed in the matched population thereafter. CONCLUSIONS: Compared with an age- and sex-matched population, TAVR patients experienced a higher risk of stroke for up to 2 years after the procedure, and a comparable risk thereafter. (SwissTAVI Registry; NCT01368250).


Asunto(s)
Estenosis de la Válvula Aórtica , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Masculino , Humanos , Femenino , Persona de Mediana Edad , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Factores de Riesgo , Resultado del Tratamiento , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Sistema de Registros
13.
EuroIntervention ; 19(10): e865-e874, 2023 Dec 04.
Artículo en Inglés | MEDLINE | ID: mdl-37946532

RESUMEN

BACKGROUND: The prognostic value of cardiac damage staging classifications across the haemodynamic spectrum of severe aortic stenosis (AS) remains unknown. AIMS: We aimed to investigate the prognostic impact of cardiac damage staging classifications in patients with high-gradient AS (HG-AS) and low-gradient AS (LG-AS) undergoing transcatheter aortic valve implantation (TAVI). METHODS: In a prospective TAVI registry, five-year mortality was evaluated for early stages of cardiac damage (stage 0, 1, or 2) and advanced stages of cardiac damage (stage 3 or 4) in patients with HG-AS, classical low-flow (LF) LG-AS, LF LG-AS with preserved ejection fraction (pEF), and normal-flow (NF) LG-AS. RESULTS: Among 2,090 patients undergoing TAVI, 1,045 patients had HG-AS, 337 patients had classical LF LG-AS, 394 patients had LF LG-AS with pEF, and 314 patients had NF LG-AS. The majority of patients with classical LF LG-AS exhibited advanced cardiac damage (73.6%), followed by LF LG-AS with pEF (55.6%), NF LG-AS (51.6%), and HG-AS (50.6%). Patients with advanced stage cardiac damage had significantly higher mortality after TAVI than those with early stage cardiac damage in all subtypes of AS (adjusted hazard ratio [HRadjusted] 1.66, 95% confidence interval [CI]: 1.34-2.06 for HG-AS; HRadjusted 1.49, 95% CI: 1.02-2.16 for classical LF LG-AS; HRadjusted 1.69, 95% CI: 1.22-2.35 for LF LG-AS with pEF; and HRadjusted 1.52, 95% CI: 1.04-2.32 for NF LG-AS). CONCLUSIONS: Cardiac damage staging classifications stratified mortality after TAVI irrespective of AS subtype.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Pronóstico , Estudios Prospectivos , Volumen Sistólico , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Índice de Severidad de la Enfermedad , Función Ventricular Izquierda
14.
Circ Rep ; 5(9): 358-364, 2023 Sep 08.
Artículo en Inglés | MEDLINE | ID: mdl-37693232

RESUMEN

Background: Very severe aortic stenosis (AS) has a poor prognosis even in asymptomatic patients, and asymptomatic very severe AS is a Class IIa indication for aortic valve replacement, although the safety and effectiveness of transcatheter aortic valve implantation (TAVI) for very severe AS is not well-established. Methods and Results: This study included 366 patients undergoing TAVI at a single center, with 85 and 281 patients in the very severe AS (peak velocity ≥5 m/s or mean pressure gradient (PG) ≥60 mmHg) and severe AS groups, respectively. Procedural and clinical outcomes at 1-year follow-up were compared between groups. The calcium scores were significantly higher in the very severe AS group (2,864.5 vs. 1,405.8 arbitrary units [AU] (P<0.001). Although the patient-prosthesis mismatch rate was higher in the very severe AS group (38.3% vs. 25.7%; P=0.029), there was no significant difference in the early safety and clinical efficacy between the groups (16.5% vs. 17.1% and 12.0% vs. 18.9%, respectively). Similarly, there was no significant difference in all-cause mortality at 1 year (4.8% vs. 9.8%). Conclusions: Despite a higher incidence of prosthesis-patient mismatch in those with very severe AS, the procedural and clinical outcomes were comparable to those in patients with severe AS. TAVI may be a reasonable treatment option for very severe AS.

15.
EuroIntervention ; 19(9): 746-756, 2023 Nov 17.
Artículo en Inglés | MEDLINE | ID: mdl-37622754

RESUMEN

BACKGROUND: Both measured and predicted effective orifice area (EOA) indexed to the body surface area (EOAi) have been suggested to define prosthesis-patient mismatch (PPM) in patients undergoing transcatheter aortic valve replacement (TAVR). The impact of PPM on clinical outcomes may accumulate with extended follow-up and vary according to the definition used. AIMS: We aimed to investigate the long-term clinical impact of PPM in patients undergoing TAVR. METHODS: Patients in a prospective TAVR registry were stratified by the presence of moderate (0.65-0.85 or 0.55-0.70 cm2/m2 if obese) or severe (≤0.65 or ≤0.55 cm2/m2 if obese) PPM according to echocardiographically measured EOAi (measured PPM), predicted EOAi based on published EOA reference values for each valve model and size (predicted PPMTHV), or predicted EOAi based on EOA reference values derived from computed tomography measurements of aortic annulus dimensions (predicted PPMCT). RESULTS: In an analysis of 2,463 patients, the frequency of measured PPM (moderate: 27.0%; severe: 8.7%) was higher than the frequency of predicted PPMTHV (moderate: 11.3%; severe: 1.2%) or predicted PPMCT (moderate: 12.0%; severe: 0.1%). During a median follow-up of 429 days, 10-year mortality was comparable in patients with versus without measured PPM or predicted PPMCT. In contrast, patients with moderate predicted PPMTHV had a lower risk of 10-year all-cause mortality compared with those without PPM (adjusted hazard ratio: 0.73, 95% confidence interval: 0.55-0.96). CONCLUSIONS: The use of predicted versus measured EOAi results in a lower estimate of PPM severity. We observed no increased risk of death in patients with PPM over a median follow-up time of 429 days. CLINICALTRIALS: gov: NCT01368250.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estudios Prospectivos , Diseño de Prótesis , Resultado del Tratamiento , Obesidad , Factores de Riesgo
16.
Am J Cardiol ; 204: 32-39, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37536202

RESUMEN

Healthcare systems adopted various strategies to minimize the impact of the COVID-19 pandemic on clinical outcomes of patients with symptomatic severe aortic stenosis referred for transcatheter aortic valve implantation (TAVI). We aimed to compare baseline characteristics and procedural and clinical outcomes of patients who underwent TAVI during COVID-19 surge periods with those of patients who underwent TAVI during the nonsurge and prepandemic periods. In the prospective Bern TAVI registry, the pandemic period was divided into surge and nonsurge periods on the basis of the mean number of occupied beds in the intensive care unit in each month and matched with 11 months immediately preceding the pandemic. A total of 1,069 patients underwent TAVI between April 1, 2019 and December 31, 2021. Patients who underwent TAVI during surge periods had a higher surgical risk (Society of Thoracic Surgeons predicted risk of mortality) than that of patients who underwent TAVI during nonsurge and prepandemic periods. Diagnosis-to-procedure time (in days) was longer for patients who underwent TAVI during the surge period than during the nonsurge and prepandemic periods (95.20 ± 121.07 vs 70.99 ± 72.25 and 60.46 ± 75.43, both p <0.001). At 30 days, all-cause mortality was higher in the surge than in the nonsurge group (4.9 vs 1.1%, hazard ratio 4.68, 95% confidence interval 1.55 to 14.10, p = 0.006), and in the surge than in the prepandemic group (4.9 vs 1.3%, hazard ratio 3.67, 95% confidence interval 1.34 to 10.11, p = 0.012). In conclusion, TAVI during COVID-19 surge periods was associated with higher Society of Thoracic Surgeons predicted risk of mortality score, delayed procedure scheduling, and increased 30-day mortality than that of TAVI during nonsurge and prepandemic periods.


Asunto(s)
Estenosis de la Válvula Aórtica , COVID-19 , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/epidemiología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Resultado del Tratamiento , Estudios Prospectivos , Pandemias , Factores de Riesgo , COVID-19/epidemiología , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos
18.
J Am Soc Echocardiogr ; 36(12): 1302-1314, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37507058

RESUMEN

BACKGROUND: The role of echocardiography in deriving transvalvular mean gradients from transaortic velocities in aortic stenosis (AS) and in structural valve degeneration (SVD) is well established. However, reports following surgical aortic valve replacement, post-transcatheter aortic valve replacement (TAVR), and valve-in-valve-TAVR (ViV-TAVR) have cautioned against the use of echocardiography-derived mean gradients to assess normal functioning bioprosthesis due to discrepancy compared with invasive measures in a phenomenon called discordance. METHODS: In a multicenter study, intraprocedural echocardiographic and invasive mean gradients in AS, SVD, post-native TAVR, and post-ViV-TAVR were compared, when obtained concomitantly, and discharge echocardiographic gradients were recorded. Absolute discordance (intraprocedural echocardiographic - invasive mean gradient) and percent discordance (intraprocedural echocardiographic - invasive mean gradient/echocardiographic mean gradient) were calculated. Multivariable regression analysis was performed to determine variables independently associated with elevated postprocedure invasive gradients ≥20 mm Hg, absolute discordance >10 mm Hg, and discharge echocardiographic mean gradient ≥20 mm Hg. RESULTS: A total of 5,027 patients were included in the registry: 4,725 native TAVR and 302 ViV-TAVR. Intraprocedural concomitant echocardiographic and invasive mean gradients were obtained pre-TAVR in AS (n = 2,418), pre-ViV-TAVR in SVD (n = 101), in post-ViV-TAVR (n = 77), and in post-TAVR (n = 823). Echocardiographic and invasive mean gradients demonstrated strong correlation (r = 0.69) and agreement (bias, 0.11; 95% CI, -0.4-0.62) in AS, moderate correlation (r = 0.56) and agreement (bias, 1.08; 95% CI, -2.53 to 4.59) in SVD, moderate correlation (r = 0.61) and weak agreement (bias, 6.47; 95% CI, 5.08-7.85) post-ViV-TAVR, and weak correlation (r = 0.18) and agreement (bias, 3.41; 95% CI, 3.16-3.65) post-TAVR. Absolute discordance occurs primarily in ViV-TVR and is not explained by sinotubular junction size and increases with increasing echocardiographic mean gradient. Percent discordance in AS and SVD (1.3% and 4%, respectively) was lower compared with post-TAVR/ViV-TAVR (66.7% and 100%, respectively). Compared with self-expanding valves, balloon expanding valves were independently associated with elevated discharge echocardiographic but lower invasive mean gradient (odds ratio = 3.411, 95% CI, 1.482-7.852, P = .004; vs odds ratio = 0.308, 95% CI, 0.130-0.731, P = .008, respectively). CONCLUSIONS: Post-TAVR/ViV-TAVR, echocardiography is discordant from invasive mean gradients, and absolute discordance increases with increasing echocardiographic mean gradient and is not explained by sinotubular junction size. Percent discordance is significantly higher post-TAVR/ViV-TAVR than in AS and SVD. Post-TAVR/ViV-TAVR, poor correlation and wide limits of agreement suggest echocardiographic and invasive mean gradients may not be used interchangeably and a high residual echocardiographic mean gradient should be confirmed invasively before considering any additional procedure to "correct" the gradient. Transcatheter aortic valve replacement valve types have variable impact on echocardiographic and invasive mean gradients.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Diseño de Prótesis , Falla de Prótesis , Resultado del Tratamiento , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Ecocardiografía
20.
Cardiovasc Revasc Med ; 56: 27-34, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37210220

RESUMEN

AIMS: The interplay between pulmonary hypertension (PH) and right ventricular (RV) function is reflected in an index of RV function to pulmonary artery (PA) systolic pressure (PASP). The present study aimed to assess the importance of RV-PA coupling on clinical outcomes after transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS: In a prospective TAVI registry, clinical outcomes of TAVI patients with RV dysfunction or PH were stratified according to coupling or uncoupling of tricuspid annular plane systolic excursion (TAPSE) to PASP, and compared to those of patients with normal RV function and absence of PH. The median TAPSE/PASP ratio was used to differentiate uncoupling (>0.39) from coupling (<0.39). Among 404 TAVI patients, 201 patients (49.8 %) had RVD or PH at baseline: 174 patients had RV-PA uncoupling, and 27 had coupling at baseline. RV-PA hemodynamics normalized in 55.6 % of patients with RV-PA coupling and in 28.2 % of patients with RV-PA uncoupling, and deteriorated in 33.3 % of patients with RV-PA coupling and in 17.8 % of patients with no RVD, respectively, at discharge. Patients with RV-PA uncoupling after TAVI showed a trend towards an increased risk of cardiovascular death at 1 year as compared to patients with normal RV-function (HRadjusted 2.06, 95 % CI 0.97-4.37). CONCLUSION: After TAVI, RV-PA coupling changed in a significant proportion of patients and is a potentially important metric for risk stratification of TAVI patients with RVD or PH. TWEET: "Patients with right ventricular dysfunction and pulmonary hypertension are at increased risk of death after TAVI. Integrated right ventricular to pulmonary artery hemodynamics change after TAVI in a significant proportion of patients and is instrumental to refine risk stratification." CLINICAL TRIAL REGISTRATION: https://www. CLINICALTRIALS: gov: NCT01368250.


Asunto(s)
Estenosis de la Válvula Aórtica , Hipertensión Pulmonar , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Hipertensión Pulmonar/diagnóstico por imagen , Arteria Pulmonar/diagnóstico por imagen , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estudios Prospectivos , Función Ventricular Derecha
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...