Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
J Arrhythm ; 40(2): 363-373, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38586857

RESUMEN

Background: The precise details of atrial activation around the triangle of Koch (ToK) remain unknown. We evaluated the relationship between the atrial-activation pattern around the ToK and success sites for slow-pathway (SP) modification ablation in slow-fast atrioventricular reentrant tachycardia (AVNRT). Methods: Thirty patients with slow-fast AVNRT who underwent successful ablation were enrolled. Atrial activation around the ToK during sinus rhythm was investigated using ultra-high-density mapping pre-ablation. The relationships among features of atrial-activation pattern and success sites were examined. Results: Of 30 patients (22 cryoablation; 8 radiofrequency ablation), 26 patients had a collision site of two wavefronts of delayed atrial activation within ToK, indicating a success site. The activation-search function of Lumipoint software, which highlights only atrial activation with a spatiotemporal consistency, showed non-highlighted area on the tricuspid-annulus side of ToK. In 23 of the patients, a spiky potential was recorded at that collision site outside the Lumipoint-highlighted area. Fifteen cryoablation patients with a success site coincident with a collision site outside the Lumipoint-highlighted area had significantly more frequent disappearances of SP after initial cryoablation (46.7% vs. 0%, p = .029), fewer cryoablations (3.7 ± 1.8 vs. 5.3 ± 1.3, p = .045), and shorter procedure times (170 ± 57 vs. 228 ± 91 min, p = .082) compared to the seven cryoablation patients without such sites. Four patients had transient AV block by ablation inside the Lumipoint-highlighted area with fractionated signals, but no patient developed permanent AV block or recurrence post-procedure (median follow-up: 375 days). Conclusions: SP modification ablation at the collision site of atrial activation of the tricuspid-annulus side along with a spiky potential could provide a better outcome.

2.
Hypertens Res ; 2024 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-38532036

RESUMEN

Lack of the typical nocturnal blood pressure (BP) fall, i.e non-dipper, has been known as a cardiovascular risk. However, the influence of non-dipper on atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI) has been unclear. We investigated the clinical impact of non-dipping as evaluated by 24-hour ambulatory BP monitoring on the long-term outcome of AF recurrence post-PVI in 76 AF patients with a history of increased BP. The PVI procedure was successful in all 76 patients (mean age, 66±9years; antihypertensive medication, 89%; non-paroxysmal AF, 24%). Twenty patients had AF recurrence during a median follow-up of 1138 days. There was no difference in BP levels between the AF recurrence and non-recurrence groups (average 24 h systolic BP:126 ± 17 vs.125 ± 14 mmHg; P = 0.84). On the other hand, the patients with non-dipper had a higher AF recurrence than those with dipper (38.9% vs.15.0%; P = 0.018). In Cox hazard analysis adjusted by age, non-paroxysmal AF and average 24-hr systolic BP level, the non-dipper was an independent predictor of AF recurrence (HR 2.78 [95%CI:1.05-7.34], P = 0.039). Non-dipper patients had a larger left atrial (LA) volume index than the dipper patients (45.9 ± 17.3 vs.38.3 ± 10.2 ml/m2, P = 0.037). Among the 58 patients who underwent high-density voltage mapping in LA, 11 patients had a low-voltage area (LVA) defined as an area with a bipolar voltage < 0.5 mV. However, there was no association of LVA with non-dipper or dipper (22.2% vs.16.1%, P = 0.555). Non-dipper is an independent predictor of AF recurrence post-PVI. Management of abnormal diurnal BP variation post-PVI may be important.

4.
J Arrhythm ; 39(4): 574-579, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37560274

RESUMEN

Background: While most VVI pacemakers in bradycardic patients are set to a low limit of 60/min, the optimal lower limit rate for VVI pacemakers in atrial fibrillation has not been established. Although an increase in heart rate within the normal range in the setting of a VVI pacemaker might be expected to lead to an increase in cardiac output with the shortening of the diastolic time, the changes in cardiac output at different pacemaker settings have not been fully clarified. Methods: We included 11 patients with bradycardic atrial fibrillation who had VVI pacemakers implanted. Stroke volume was measured using the electrical cardiometry method (AESCULONⓇ mini; Osypka Medical) without pacing and at ventricular pacings of 60, 70, 80, and 90/min. Results: Stroke volume decreased stepwise at ventricular pacing rates of 60, 70, 80, and 90/min (63.6 ± 11.2, 61.9 ± 10.6, 59.3 ± 12.2, and 57.5 ± 12.2 mL, p < .001), but cardiac output increased (3.81 ± 0.67, 4.33 ± 0.74, 4.74 ± 0.97, and 5.17 ± 1.09 L/min, p < .001). The rate of increase in cardiac output at a pacing rate of 70/min compared to 60/min correlated with left ventricular end-systolic volume (r = 0.711, p = .014). Conclusions: Cardiac output increased at a pacing rate of 70 compared to 60 in bradycardic atrial fibrillation patients, and the rate of increase in cardiac output was greater in those with larger left ventricular end-systolic volume.

5.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37539865

RESUMEN

AIMS: The relationship between local unipolar voltage (UV) in the pulmonary vein (PV)-ostia and left atrial wall thickness (LAWT) and the utility of these parameters as indices of outcome after atrial fibrillation (AF) ablation remain unclear. METHODS AND RESULTS: Two-hundred seventy-two AF patients who underwent AF ablation were enrolled. Unipolar voltage of PV-ostia was measured using a CARTO system, and LAWT was measured using computed tomography. The primary endpoint was atrial tachyarrhythmia (ATA) recurrence including AF. The ATA recurrence was documented in 74 patients (ATA-Rec group). The UV and LAWT of the bilateral superior PV roof to posterior and around the right-inferior PV in the ATA-Rec group were significantly greater than in patients without ATA recurrence (ATA-Free group) (P < 0.001). The UV had a strong positive correlation with LAWT (R2 = 0.446, P < 0.001). The UV 2.7 mV and the corresponding LAWT 1.6 mm were determined as the cut-off values for ATA recurrence (P < 0.001, respectively). Multisite LA high UV (HUV, ≥4 areas of >2.7 mV) or multisite LA wall thickening (≥5 areas of >1.6 mm), defined as LA hypertrophy (LAH), was related to higher ATA recurrence. Among 92 LAH patients, 66 had HUV (LAH-HUV) and the remaining 26 had low UV (LAH-LUV), characterized by history of non-paroxysmal AF and heart failure, reduced LV ejection fraction, or enlarged LA. In addition, LAH-LUV showed the worst ablation outcome, followed by LAH-HUV and No LAH (log-rank P < 0.001). CONCLUSION: Combining UV and LAWT enables us to stratify recurrence risk and suggest a tailored ablation strategy according to LA tissue properties.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Apéndice Atrial/cirugía , Taquicardia/etiología , Tomografía Computarizada por Rayos X , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
6.
Int Heart J ; 64(2): 316-320, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37005323

RESUMEN

Pulmonary arterial hypertension (PAH) is a rare and fatal disease for which some causative drugs have been developed. Qing-Dai is a Chinese herbal drug that is sometimes used as a specific treatment for ulcerative colitis in Asia, including Japan. Here, we report a case of severe Qing-Dai-induced PAH. A 19-year-old woman who has been taking Qing-Dai for 8 months was admitted for exertional dyspnea. Her mean pulmonary artery pressure dramatically improved from 72 to 18 mmHg with Qing-Dai discontinuation and PAH-specific therapy. After 6 years of onset, she had not relapsed with PAH with PAH-specific therapy.


Asunto(s)
Colitis Ulcerosa , Medicamentos Herbarios Chinos , Hipertensión Pulmonar , Hipertensión Arterial Pulmonar , Humanos , Femenino , Adulto Joven , Adulto , Colitis Ulcerosa/tratamiento farmacológico , Medicamentos Herbarios Chinos/efectos adversos , Hipertensión Arterial Pulmonar/tratamiento farmacológico , Hipertensión Arterial Pulmonar/etiología , Hipertensión Pulmonar/tratamiento farmacológico , Hipertensión Pulmonar/inducido químicamente , Arterias
7.
Intern Med ; 62(8): 1191-1194, 2023 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-36754404

RESUMEN

A 23-year-old man with no significant medical history was rushed to a hospital due to transient loss of consciousness with incontinence. The patient had developed a fever after his second dose of coronavirus disease 2019 (COVID-19) vaccine, and the patient was found groaning in bed approximately 40 hours after the vaccination in the early morning. The patient was diagnosed with Brugada syndrome (BrS) based on a drug-provocation test. His father had been diagnosed with BrS and died suddenly at 51 years of age. Young adults with a family history of BrS should be cautioned about fever following COVID-19 vaccination.


Asunto(s)
Síndrome de Brugada , Vacunas contra la COVID-19 , COVID-19 , Adulto , Humanos , Masculino , Adulto Joven , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/etiología , COVID-19/prevención & control , Vacunas contra la COVID-19/efectos adversos , Electrocardiografía , Fiebre , Síncope/etiología
8.
J Cardiovasc Electrophysiol ; 34(4): 849-859, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36738145

RESUMEN

INTRODUCTION: Beyond pulmonary vein isolation (PVI), additional therapeutic strategies for atrial fibrillation (AF) have not been established. Remodeling of the left atrium (LA) could impact AF recurrence post-PVI. We investigated the impact of unipolar voltage (UV) criteria for the LA posterior wall (LA-PW) on AF recurrence post-PVI. METHODS: We reviewed the cases of 106 AF patients (mean age 63.8 years, nonparoxysmal AF: 59%) who underwent extensive encircling PVI by radiofrequency ablation guided by a 3-dimension mapping system, investigating the impact on AF recurrence of the UV criteria of the LA. RESULTS: Out of all patients, 26 patients had AF recurrence during post-PVI follow-up [median 603 days]. They showed a higher percentage of nonparoxysmal AF (80.8 vs. 52.5%, p = .011), longer AF duration (2.9 ± 2.7 vs. 1.0 ± 1.7 years, p = .002), and larger area size of UV < 2.0 mV in LA-PW (2.8 ± 1.8 vs. 1.0 ± 1.5 cm2 , p < .001) than those without recurrence. Cox Hazard analysis for AF recurrence adjusted by age, gender, AF duration, body mass index and left atrial volume index revealed that an area size over 2.0 cm2 of UV < 2.0 mV in LA-PW (HR 6.9 [95% CI:1.3-35.5], p = .021) posed independent risks for AF recurrence post-PVI. The atrial arrhythmia-free survival rate was higher in those with no area of UV < 3.0 mV in LA-PW compared to those with a sizable area (>2.0 cm2 ) of UV < 3.0 mV and <2.0 mV (95.0% vs. 74.2% vs. 57.1%, Log-Rank: p < .001). In the AF etiology of patients with AF recurrence, 9 of 14 patients who underwent the 2nd procedure had no PV reconnection, and 8 patients required the LA-PW isolation for their non-PV AF. CONCLUSION: UV criteria of LA-PW is a useful parameter for AF-recurrence post-PVI. Lower UV in LA-PW as an indication of electrical remodeling could indicate a higher risk of AF recurrence and the need for further therapeutic strategies.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Persona de Mediana Edad , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Atrios Cardíacos , Venas Pulmonares/cirugía , Resultado del Tratamiento , Estudios Retrospectivos
9.
J Electrocardiol ; 75: 44-51, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36306606

RESUMEN

PURPOSE: Cryoablation is a safe alternative to radiofrequency (RF) ablation for slow-fast atrioventricular reentrant tachycardia (AVNRT); however, optimal electrogram parameters for site selection remain unknown. We retrospectively investigated local electrograms for slow pathway (SP) modification in cryoablation. METHODS: Forty-five consecutive patients with slow-fast AVNRT who underwent cryoablation using a 6-mm-tip catheter were enrolled. Electrogram parameters for sites of successful SP modification (success-sites) were investigated; these included the interval between atrial activation at His and the last deflection of SP potential, defined as the His(A)-SPP interval. In 8 patients, 3-dimensional mapping by multi-electrode catheter was performed pre-ablation for more detailed SP assessment. RESULTS: Twenty-seven of 45 patients had successful SP modification by 1 cycle of freeze-thaw-freeze cryoablation at a single site with a low amplitude and fragmented SP potential. Among a total of 76 cryoablation sites in all patients, the His(A)-SPP interval at success-sites (45 sites) was significantly longer than that at unsuccess-sites (31 sites) (86 ± 9 vs.78 ± 10 msec, p < 0.0001). The AV amplitude ratio was not significantly different between success-and unsuccess-sites (0.21 ± 0.22 vs.0.25 ± 0.23, p = 0.429). The cutoff value of the His(A)-SPP interval for successful cryoablation was 82 msec with a sensitivity of 0.67 and specificity of 0.71 (AUC: 0.739; 95%CI: 0.626-0.852; p < 0.0001). Three-dimensional mapping in all 8 patients showed that sites with the most delayed atrial activation and the last deflection of the fragmented SP potential within the Koch's triangle coincided with success-sites. CONCLUSION: A longer His(A)-SPP interval and fractionated SP potential were characteristics of successful cryoablation for SP modification in slow-fast AVNRT.


Asunto(s)
Ablación por Catéter , Criocirugía , Taquicardia por Reentrada en el Nodo Atrioventricular , Taquicardia Supraventricular , Humanos , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Estudios Retrospectivos , Electrocardiografía , Ablación por Catéter/métodos , Resultado del Tratamiento
10.
Int Heart J ; 63(2): 241-246, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35354746

RESUMEN

There are no studies examining interventricular (VV) delay optimization by an electrical cardiometry method in relation to subsequent cardiac function in cardiac resynchronization therapy (CRT) -implanted patients. This study aimed to compare the VV delay in CRT-implanted patients by the dp/dt and electrical cardiometry and to examine the optimization of VV delay and improvement of cardiac function. We examined 19 consecutive CRT-implanted patients. The protocol included biventricular stimulation with either simultaneous or sequential pacing, and we evaluated systolic volume (SV) using an electrical cardiometry and the dp/dt of the left ventricle. The optimal VV delay was determined by the maximum SV using the electrical cardiometry. Two groups were defined, those whose increase in SV was at or above the median and those whose SV increase was below the median; changes in left ventricular ejection fraction (LVEF). The correlation between the VV delay optimized by the electrical cardiometry and dp/dt methods was high (R = 0.61, P = 0.006). Compared to the baseline SV (43.4 mL), the SV increased to 47.8 mL with simultaneous biventricular pacing (versus baseline P = 0.008) and further increased to 49.8 mL with optimized VV delay (versus simultaneous biventricular pacing P = 0.020). LVEF after 6 months significantly improved in the above-median SV increase group (37.6 versus 28.2%, P = 0.041), but not in the below-median SV increase group (26.5 versus 26.5%, P = 0.985). In conclusion, the optimal VV delay by electrical cardiometry method was almost concordant with that by the dp/dt method. Cardiac function significantly improved in the group with the above-median SV increase.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Terapia de Resincronización Cardíaca/métodos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Humanos , Volumen Sistólico/fisiología , Sístole , Función Ventricular Izquierda
12.
Int Heart J ; 62(2): 344-349, 2021 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-33731516

RESUMEN

Cardiovascular event rates of patients with a dipper blood pressure (BP) and dipper heart rate (HR) pattern are lower than those of patients with nondipper BP and HR patterns. However, how the pacemaker mode affects the diurnal BP and HR patterns remains unclear.We enrolled nine patients (average age 74.4 ± 6.6 years, 4 males and 5 females) with sick sinus syndrome who required atrial pacing. We investigated sequential 6-month pacing regimens (DDD mode at 60 bpm and sleep rate mode). We set the lower rate of sleep rate mode as follows: 60 bpm during the daytime and 50 bpm during the nighttime. The order of pacing mode was randomized, with crossover design. Ambulatory BP monitoring was performed at baseline, 6 months, and 12 months, BP category was classified into four groups (extreme dipper, dipper, nondipper, and riser pattern), and HR was classified into dipper and nondipper patterns.Nighttime HR during the sleep rate mode was significantly lower than that at DDD (57.1 ± 6.2 versus 63.5 ± 3.8 bpm, P = 0.001). The dipper HR pattern was increased in the sleep rate mode compared with those at baseline or DDD mode (versus baseline: 89% versus 44%, P = 0.035; versus DDD: 89% versus 22%, P = 0.004). The dipper BP pattern significantly increased in the sleep rate mode compared with the baseline (56% versus 11%, P = 0.035), but the difference between the sleep rate mode and DDD mode was statistically marginal (56% versus 22%, P = 0.081).The pacemaker settings in the sleep rate mode increased the dipper HR and BP patterns in pacemaker-dependent patients with sick sinus syndrome.


Asunto(s)
Sistema Nervioso Autónomo/fisiopatología , Presión Sanguínea/fisiología , Ritmo Circadiano/fisiología , Atrios Cardíacos/fisiopatología , Frecuencia Cardíaca/fisiología , Marcapaso Artificial , Síndrome del Seno Enfermo/fisiopatología , Sueño/fisiología , Anciano , Monitoreo Ambulatorio de la Presión Arterial , Femenino , Humanos , Masculino , Síndrome del Seno Enfermo/terapia
13.
Intern Med ; 60(14): 2327-2332, 2021 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-33612671

RESUMEN

Cardiac involvement has recently been the focus of sporadic late-onset nemaline myopathy (SLONM). However, right ventricular failure and pulmonary hypertension, in addition to repetitive cardiac arrest, are noteworthy characteristics of SLONM. We herein report a 66-year-old woman with SLONM whose main symptoms were cardiac arrest, right ventricular failure, and pulmonary hypertension. Despite permanent pacemaker replacement, cardiac arrest occurred repetitively, and even with continuous positive airway pressure, right ventricular failure and pulmonary hypertension persisted. The patient was finally diagnosed with SLONM by a muscle biopsy. Our case suggests the possibility of cardiovascular involvement in SLONM, especially right ventricular failure and pulmonary hypertension.


Asunto(s)
Miopatías Nemalínicas , Anciano , Femenino , Humanos , Miopatías Nemalínicas/complicaciones , Miopatías Nemalínicas/diagnóstico
15.
Org Lett ; 21(5): 1397-1401, 2019 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-30763097

RESUMEN

Hemisquaramide tweezers, a new family of H-bond donor organocatalysts, are reported. The catalysts could be synthesized within two steps. Among them, H8-binaphthyl-linked hemisquaramide 7 markedly accelerated the synthesis of cyclic carbonates from epoxides and CO2. The reactions proceeded well under mild and solvent-free conditions. Kinetic resolution was also achieved at -20 °C ( s = 3.0). The adjustable bite angle and orientation of the two NH groups of the catalysts are important for the high activity.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...