Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Sleep Breath ; 2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-39085560

RESUMEN

INTRODUCTION: Sleep Disordered Breathing (SDB) has been shown to increase the risk of stroke and despite recommendations, routine evaluation for SDB in acute stroke is not consistent across institutions. The necessary logistics and expertise required to conduct sleep studies in hospitalized patients remain a significant barrier. This study aims to evaluate the feasibility of high-resolution pulse-oximetry (HRPO) for the screening of SDB in acute stroke. Secondarily, considering impact of SDB on acute stroke, we investigated whether SDB at acute stroke predicts functional outcome at discharge and at 3 months post-stroke. METHODS: Patients with acute mild to moderate ischemic stroke underwent an overnight HRPO within 48 h of admission. Patients were divided into SDB and no-SDB groups based on oxygen desaturations index(ODI > 10/h). Stepwise multivariate logistic regression analysis was applied to identify the relevant predictors of functional outcome (favorable [mRS 1-2 points] versus unfavorable [mrS > = 3 points]). RESULTS: Of the 142 consecutively screened patients, 96 were included in the analysis. Of these, 33/96 (34%) were identified as having SDB and were more likely to have unfavorable mRS scores as compared to those without SDB (odds ratio = 2.70, p-value = 0.032). CONCLUSION: HRPO may be a low-cost and easily administered screening method to detect SDB among patients hospitalized for acute ischemic stroke. Patients with SDB (as defined by ODI) have a higher burden of neurological deficits as compared to those without SDB during hospitalization.

2.
PLoS One ; 19(5): e0303076, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38758825

RESUMEN

STUDY OBJECTIVE: This study aimed to prospectively validate the performance of an artificially augmented home sleep apnea testing device (WVU-device) and its patented technology. METHODOLOGY: The WVU-device, utilizing patent pending (US 20210001122A) technology and an algorithm derived from cardio-pulmonary physiological parameters, comorbidities, and anthropological information was prospectively compared with a commercially available and Center for Medicare and Medicaid Services (CMS) approved home sleep apnea testing (HSAT) device. The WVU-device and the HSAT device were applied on separate hands of the patient during a single night study. The oxygen desaturation index (ODI) obtained from the WVU-device was compared to the respiratory event index (REI) derived from the HSAT device. RESULTS: A total of 78 consecutive patients were included in the prospective study. Of the 78 patients, 38 (48%) were women and 9 (12%) had a Fitzpatrick score of 3 or higher. The ODI obtained from the WVU-device corelated well with the HSAT device, and no significant bias was observed in the Bland-Altman curve. The accuracy for ODI > = 5 and REI > = 5 was 87%, for ODI> = 15 and REI > = 15 was 89% and for ODI> = 30 and REI of > = 30 was 95%. The sensitivity and specificity for these ODI /REI cut-offs were 0.92 and 0.78, 0.91 and 0.86, and 0.94 and 0.95, respectively. CONCLUSION: The WVU-device demonstrated good accuracy in predicting REI when compared to an approved HSAT device, even in patients with darker skin tones.


Asunto(s)
Inteligencia Artificial , Síndromes de la Apnea del Sueño , Humanos , Femenino , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Síndromes de la Apnea del Sueño/diagnóstico , Síndromes de la Apnea del Sueño/fisiopatología , Anciano , Polisomnografía/instrumentación , Polisomnografía/métodos , Algoritmos , Adulto
3.
J Clin Sleep Med ; 20(8): 1313-1319, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38557651

RESUMEN

STUDY OBJECTIVES: Obstructive sleep apnea (OSA) is a highly prevalent, yet underdiagnosed, condition. Due to its adverse impact on risk for cardiopulmonary disorders, there is interest in proactive screening of OSA in hospitalized patients. We studied the long-term outcome of such screened patients who were initiated on positive airway pressure therapy. METHODS: Hospitalized patients who screened positive for OSA and were confirmed with postdischarge polysomnography were dichotomized by positive airway pressure therapy adherence and followed for a period of 12 months to evaluate for the composite end point of hospital readmissions and emergency department visits for cardiopulmonary reasons. Cost analysis between the 2 groups was also conducted. RESULTS: A total of 2,042 hospitalized patients were assessed for OSA as part of a hospital sleep medicine program from August 2019-June 2023. Of these, 293 patients were diagnosed with OSA and prescribed positive airway pressure therapy. Of these 293 patients, 108 were adherent to therapy and 185 were nonadherent. The overall characteristics of the groups included a mean (standard deviation) age of 58 years (12.82), mean body mass index (kg/m2) of 39.72 (10.71), 57% male sex, and apnea-hypopnea index of 25.49 (26). Of the patients, 78%, 41%, and 43% had hypertension, congestive heart failure, and diabetes mellitus, respectively. The composite end point of hospital readmissions and emergency department visits for cardiovascular and pulmonary reasons was significantly higher in the nonadherent group than in the adherent group (hazard ratio, 1.24; 95% confidence interval, 1-1.54) (P = .03). The cost of care for both hospital billing as well as professional billing was higher for the nonadherent group ($1,455.60 vs $1,723.50, P = .004 in hospital billing cost and $130.90 vs $144.70, P < .001 in professional billing). Length of stay was higher for nonadherent patients (2.7 ± 5.1 days vs 2.3 ± 5.9 days). CONCLUSIONS: Hospitalized patients diagnosed with OSA and adherent to therapy have reduced readmissions and emergency department visits for cardiopulmonary reasons 12 months after discharge. Adherent patients have reduced cost of health care and length of stay during hospitalizations. CITATION: Sharma S, Stansbury R, Srinivasan P, et al. Early recognition and treatment of OSA in hospitalized patients and its impact on health care utilization in rural population: a real-world study. J Clin Sleep Med. 2024;20(8):1313-1319.


Asunto(s)
Hospitalización , Aceptación de la Atención de Salud , Población Rural , Apnea Obstructiva del Sueño , Humanos , Apnea Obstructiva del Sueño/terapia , Apnea Obstructiva del Sueño/economía , Apnea Obstructiva del Sueño/epidemiología , Masculino , Femenino , Persona de Mediana Edad , Aceptación de la Atención de Salud/estadística & datos numéricos , Población Rural/estadística & datos numéricos , Hospitalización/estadística & datos numéricos , Hospitalización/economía , Polisomnografía/estadística & datos numéricos , Polisomnografía/economía , Presión de las Vías Aéreas Positiva Contínua/estadística & datos numéricos , Presión de las Vías Aéreas Positiva Contínua/economía , Presión de las Vías Aéreas Positiva Contínua/métodos , Diagnóstico Precoz , Anciano , Readmisión del Paciente/estadística & datos numéricos , Readmisión del Paciente/economía
4.
JAAPA ; 36(9): 47-48, 2023 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-37668481
5.
Sleep Breath ; 27(5): 1935-1938, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-36715837

RESUMEN

INTRODUCTION: Obstructive sleep apnea (OSA) is a highly prevalent disorder that often is unrecognized. Recently, a novel protocol for screening hospitalized patients for OSA resulted in early initiation of positive airway pressure (PAP) therapy and early post-discharge follow-up. The protocol utilizes a combination of high-resolution pulse oximetry (HRPO) and home sleep apnea tests (HSATs); the former has been well-validated in previous studies against HSAT and polysomnography. While a definitive treatment plan can be generated for patients with a positive HRPO for OSA, it is less clear how best to manage patients with a negative HRPO. MATERIALS AND METHODS: A retrospective analysis of a registry of patients screened for OSA was conducted. Consecutive patients with HRPO-derived ODI (oxygen desaturation index) < 5/h who underwent same-night HRPO and HSAT were identified. The demographic and clinical characteristics of patients with ODI < 5/h and AHI (apnea hypopnea index) < 5/h were compared with patients with ODI < 5/h and AHI ≥ 5/h. RESULTS: The analysis revealed 190 patients with ODI < 5/h. Only 23 (12%) of these patients had AHI ≥ 5/h. When compared with patients who had ODI < 5/h and AHI < 5/h, there was no difference in most testing and patient characteristics. However, antiplatelet use and total time in minutes with saturation < 88% greater than 100 min were associated with a higher likelihood of discordant ODI and AHI. CONCLUSION: HRPO-derived ODI has a low rate of false negativity. Clinicians should be aware of the possibility of a false negative ODI for patients with antiplatelet use and time with saturation < 88% greater than 100 min and antiplatelet therapy.


Asunto(s)
Cuidados Posteriores , Apnea Obstructiva del Sueño , Humanos , Estudios Retrospectivos , Alta del Paciente , Apnea Obstructiva del Sueño/diagnóstico , Apnea Obstructiva del Sueño/terapia , Oximetría/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA