Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Rapid Commun Mass Spectrom ; 37(6): e9454, 2023 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-36477973

RESUMEN

RATIONALE: Back-side thinning of wafers is used to eliminate issues with transient sputtering when analyzing near-surface element distributions. Precise and accurate calibrated implants are created by including a standard reference material during the implantation. Combining these methods allows accurate analysis of low-fluence, shallow features even if matrix effects are a concern. METHODS: Implanted Na (<2.0 × 1011 ions/cm2 , peaking <50 nm) in diamond-like carbon (DLC) film on silicon (solar wind returned by NASA's Genesis mission) was prepared for measurement as follows. Implanted surfaces of samples were epoxied to wafers and back-side-thinned using physical or chemical methods. Thinned samples were then implanted with reference ions for accurate quantification of the solar wind implant. Analyses used a CAMECA IMS 7f-GEO SIMS in depth-profiling mode. RESULTS: Back-side-implanted reference ions reduced the need to change sample mounts or stage position and could be spatially separated from the solar wind implant even when measuring monoisotopic ions. Matrix effects in DLC were mitigated and the need to find an identical piece of DLC for a reference implant was eliminated. Accuracy was only limited by the back-side technique itself. CONCLUSIONS: Combining back-side depth profiling with back-side-implanted internal standards aides quantification of shallow mono- and polyisotopic implants. This technique helps mitigate matrix effects and keeps measurement conditions consistent. Depth profile acquisition times are longer, but if sample matrices are homogeneous, procedural changes can decrease measurement times.

2.
Meteorit Planet Sci ; 55(2): 326-351, 2020 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-32256027

RESUMEN

NASA's Genesis mission was flown to capture samples of the solar wind and return them to the Earth for measurement. The purpose of the mission was to determine the chemical and isotopic composition of the Sun with significantly better precision than known before. Abundance data are now available for noble gases, magnesium, sodium, calcium, potassium, aluminum, chromium, iron, and other elements. Here, we report abundance data for hydrogen in four solar wind regimes collected by the Genesis mission (bulk solar wind, interstream low-energy wind, coronal hole high-energy wind, and coronal mass ejections). The mission was not designed to collect hydrogen, and in order to measure it, we had to overcome a variety of technical problems, as described herein. The relative hydrogen fluences among the four regimes should be accurate to better than ±5-6%, and the absolute fluences should be accurate to ±10%. We use the data to investigate elemental fractionations due to the first ionization potential during acceleration of the solar wind. We also use our data, combined with regime data for neon and argon, to estimate the solar neon and argon abundances, elements that cannot be measured spectroscopically in the solar photosphere.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...