Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Oper Dent ; 49(2): 210-221, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38349816

RESUMEN

OBJECTIVES: This study aimed to evaluate the optical and mechanical performance of two single-shade resin-based composites (RBCs) compared to those of a conventional RBC for restoring posterior teeth. METHODS: Two single-shade RBCs, Omnichroma (Tukoyama) and Vittra Unique APS (FGM), and a conventional RBC, Filtek Z350XT shade A2 (3M Oral Care), were evaluated in this study. The optical shade-matching performance was measured using a spectrophotometer. The light emitted by VALO Grand (Ultradent) and transmitted through the 2.0-mm RBC specimens was evaluated using beam profiling. Knoop hardness (KH, N/mm2), degree of conversion (DC, %) at the top and bottom, flexural strength (FS, MPa), elastic modulus (E, GPa), postgel shrinkage (Shr, %), and shrinkage stress (MPa) were evaluated. Scanning electron microscopy (SEM) was used to characterize the filler. Data for FS, E, and Shr were analyzed by one-way analysis of variance (ANOVA) and KH and DC by repeated one-way ANOVA measurement followed by Tukey test (α=0.05). The modified von Mises stress values, light transmission, and SEM images were analyzed qualitatively. RESULTS: All single-shade RBCs exhibited higher chromatic adaptation than the Filtek Z350XT (p<0.001). Omnichroma exhibited less color difference than Vittra Unique APS, irrespective of the shade. The light transmitted through Omnichroma and Vittra Unique APS increased during polymerization. KH and DC values were significantly reduced from the top to the bottom of the specimens for all RBCs (p<0.001); however, the ratio values were always higher than 80%. In general, all RBCs demonstrated similar mechanical properties. All RBCs exhibited a similar FS (p=0.083) and Shr value (p=0.144). Filtek Z350XT exhibited significantly higher E (p<0.001) than both single-shade RBCs. All RBCs exhibited similar shrinkage stress during restoration and similar residual stress during occlusal loading. CONCLUSIONS: Single-shade Omnichroma and Vittra Unique APS increased light transmission during light-activation, demonstrating better chromatic adaptation than conventional Filtek Z350XT. In general, Omnichroma and Vittra Unique APS exhibited similar mechanical properties and shrinkage stress distributions as Filtek Z350XT during light-activation and occlusal loading.


Asunto(s)
Resinas Compuestas , Materiales Dentales , Estrés Mecánico , Resinas Compuestas/uso terapéutico , Módulo de Elasticidad , Dureza , Ensayo de Materiales , Polimerizacion
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...