Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sensors (Basel) ; 23(12)2023 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-37420731

RESUMEN

In rehabilitating orientation and mobility (O&M) for visually impaired people (VIP), the measurement of spatio-temporal gait and postural parameters is of specific interest for rehabilitators to assess performance and improvements in independent mobility. In the current practice of rehabilitation worldwide, this assessment is carried out in people with estimates made visually. The objective of this research was to propose a simple architecture based on the use of wearable inertial sensors for quantitative estimation of distance traveled, step detection, gait velocity, step length and postural stability. These parameters were calculated using absolute orientation angles. Two different sensing architectures were tested for gait according to a selected biomechanical model. The validation tests included five different walking tasks. There were nine visually impaired volunteers in real-time acquisitions, where the volunteers walked indoor and outdoor distances at different gait velocities in their residences. The ground truth gait characteristics of the volunteers in five walking tasks and an assessment of the natural posture during the walking tasks are also presented in this article. One of the proposed methods was selected for presenting the lowest absolute error of the calculated parameters in all of the traveling experimentations: 45 walking tasks between 7 and 45 m representing a total of 1039 m walked and 2068 steps; the step length measurement was 4.6 ± 6.7 cm with a mean of 56 cm (11.59 Std) and 1.5 ± 1.6 relative error in step count, which compromised the distance traveled and gait velocity measurements, presenting an absolute error of 1.78 ± 1.80 m and 7.1 ± 7.2 cm/s, respectively. The results suggest that the proposed method and its architecture could be used as a tool for assistive technology designed for O&M training to assess gait parameters and/or navigation, and that a sensor placed in the dorsal area is sufficient to detect noticeable postural changes that compromise heading, inclinations and balancing in walking tasks.


Asunto(s)
Marcha , Dispositivos Electrónicos Vestibles , Humanos , Caminata , Voluntarios , Postura
2.
Entropy (Basel) ; 23(7)2021 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-34356390

RESUMEN

The rehabilitation of a visually impaired person (VIP) is a systematic process where the person is provided with tools that allow them to deal with the impairment to achieve personal autonomy and independence, such as training for the use of the long cane as a tool for orientation and mobility (O&M). This process must be trained personally by specialists, leading to a limitation of human, technological and structural resources in some regions, especially those with economical narrow circumstances. A system to obtain information about the motion of the long cane and the leg using low-cost inertial sensors was developed to provide an overview of quantitative parameters such as sweeping coverage and gait analysis, that are currently visually analyzed during rehabilitation. The system was tested with 10 blindfolded volunteers in laboratory conditions following constant contact, two points touch, and three points touch travel techniques. The results indicate that the quantification system is reliable for measuring grip rotation, safety zone, sweeping amplitude and hand position using orientation angles with an accuracy of around 97.62%. However, a new method or an improvement of hardware must be developed to improve gait parameters' measurements, since the step length measurement presented a mean accuracy of 94.62%. The system requires further development to be used as an aid in the rehabilitation process of the VIP. Now, it is a simple and low-cost technological aid that has the potential to improve the current practice of O&M.

3.
J Neuromuscul Dis ; 8(4): 743-754, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33843694

RESUMEN

By definition, neuromuscular diseases are rare and fluctuating in terms of symptoms; patients are often lately diagnosed, do not have enough information to understand their condition and be proactive in their management. Usually, insufficient resources or services are available, leading to patients' social burden. From a medical perspective, the rarity of such diseases leads to the unfamiliarity of the medical staff and caregiver and an absence of consensus in disease assessment, treatment, and management. Innovations have to be developed in response to patients' and physicians' unmet needs.It is vital to improve several aspects of patients' quality of life with a better comprehension of their disease, simplify their management and follow-up, help their caregiver, and reduce the social and economic burden for living with a rare debilitating disease. Database construction regrouping patients' data and symptoms according to specific country registration on data privacy will be critical in establishing a clear consensus on neuromuscular disease treatment.Clinicians also need technological innovations to help them recognize neuromuscular diseases, find the best therapeutic approach based on medical consensus, and tools to follow patients' states regularly. Diagnosis also has to be improved by implementing automated systems to analyze a considerable amount of data, representing a significant step forward to accelerate the diagnosis and the patients' follow up. Further, the development of new tools able to precisely measure specific outcomes reliably is of the matter of importance in clinical trials to assess the efficacy of a newly developed compound.In this context, creation of an expert community is essential to communicate and share ideas. To this end, 97 clinicians, healthcare professionals, researchers, and representatives of private companies from 9 different countries met to discuss the new perspective and challenges to develop and implement innovative tools in the field of neuromuscular diseases.


Asunto(s)
Enfermedades Neuromusculares/orina , Consenso , Francia , Personal de Salud , Humanos , Calidad de Vida , Telemedicina
4.
Sensors (Basel) ; 16(11)2016 Nov 22.
Artículo en Inglés | MEDLINE | ID: mdl-27879675

RESUMEN

The main objective of this article is to demonstrate through experimental means the capacity of the quartz crystal resonator (QCR) to characterize biological samples of aqueous dilutions of hyaluronic acid according to their viscosity and how this capacity may be useful in the potential diagnosis of arthritic diseases. The synovial fluid is viscous due to the presence of hyaluronic acid, synthesized by synovial lining cells (type B), and secreted into the synovial fluid thus making the fluid viscous. In consequence, aqueous dilutions of hyaluronic acid may be used as samples to emulate the synovial fluid. Due to the viscoelastic and pseudo-plastic behavior of hyaluronic acid, it is necessary to use the Rouse model in order to obtain viscosity values comparable with viscometer measures. A Fungilab viscometer (rheometer) was used to obtain reference measures of the viscosity in each sample in order to compare them with the QCR prototype measures.


Asunto(s)
Artritis/diagnóstico , Ácido Hialurónico/química , Humanos , Líquido Sinovial/química , Viscosidad
5.
Nanoscale Res Lett ; 9(1): 441, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25232297

RESUMEN

Optical hyperthermia systems based on the laser irradiation of gold nanorods seem to be a promising tool in the development of therapies against cancer. After a proof of concept in which the authors demonstrated the efficiency of this kind of systems, a modeling process based on an equivalent thermal-electric circuit has been carried out to determine the thermal parameters of the system and an energy balance obtained from the time-dependent heating and cooling temperature curves of the irradiated samples in order to obtain the photothermal transduction efficiency. By knowing this parameter, it is possible to increase the effectiveness of the treatments, thanks to the possibility of predicting the response of the device depending on the working configuration. As an example, the thermal behavior of two different kinds of nanoparticles is compared. The results show that, under identical conditions, the use of PEGylated gold nanorods allows for a more efficient heating compared with bare nanorods, and therefore, it results in a more effective therapy.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...