Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
PLoS Med ; 21(3): e1004360, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38502656

RESUMEN

BACKGROUND: Adjuvants are widely used to enhance and/or direct vaccine-induced immune responses yet rarely evaluated head-to-head. Our trial directly compared immune responses elicited by MF59 versus alum adjuvants in the RV144-like HIV vaccine regimen modified for the Southern African region. The RV144 trial of a recombinant canarypox vaccine vector expressing HIV env subtype B (ALVAC-HIV) prime followed by ALVAC-HIV plus a bivalent gp120 protein vaccine boost adjuvanted with alum is the only trial to have shown modest HIV vaccine efficacy. Data generated after RV144 suggested that use of MF59 adjuvant might allow lower protein doses to be used while maintaining robust immune responses. We evaluated safety and immunogenicity of an HIV recombinant canarypox vaccine vector expressing HIV env subtype C (ALVAC-HIV) prime followed by ALVAC-HIV plus a bivalent gp120 protein vaccine boost (gp120) adjuvanted with alum (ALVAC-HIV+gp120/alum) or MF59 (ALVAC-HIV+gp120/MF59) or unadjuvanted (ALVAC-HIV+gp120/no-adjuvant) and a regimen where ALVAC-HIV+gp120 adjuvanted with MF59 was used for the prime and boost (ALVAC-HIV+gp120/MF59 coadministration). METHODS AND FINDINGS: Between June 19, 2017 and June 14, 2018, 132 healthy adults without HIV in South Africa, Zimbabwe, and Mozambique were randomized to receive intramuscularly: (1) 2 priming doses of ALVAC-HIV (months 0 and 1) followed by 3 booster doses of ALVAC-HIV+gp120/MF59 (months 3, 6, and 12), n = 36; (2) 2 priming doses of ALVAC-HIV (months 0 and 1) followed by 3 booster doses of ALVAC-HIV+gp120/alum (months 3, 6, and 12), n = 36; (3) 4 doses of ALVAC-HIV+gp120/MF59 coadministered (months 0, 1, 6, and 12), n = 36; or (4) 2 priming doses of ALVAC-HIV (months 0 and 1) followed by 3 booster doses of ALVAC-HIV+gp120/no adjuvant (months 3, 6, and 12), n = 24. Primary outcomes were safety and occurrence and mean fluorescence intensity (MFI) of vaccine-induced gp120-specific IgG and IgA binding antibodies at month 6.5. All vaccinations were safe and well-tolerated; increased alanine aminotransferase was the most frequent related adverse event, occurring in 2 (1.5%) participants (1 severe, 1 mild). At month 6.5, vaccine-specific gp120 IgG binding antibodies were detected in 100% of vaccinees for all 4 vaccine groups. No significant differences were seen in the occurrence and net MFI of vaccine-specific IgA responses between the ALVAC-HIV+gp120/MF59-prime-boost and ALVAC-HIV+gp120/alum-prime-boost groups or between the ALVAC-HIV+gp120/MF59-prime-boost and ALVAC-HIV+gp120/MF59 coadministration groups. Limitations were the relatively small sample size per group and lack of evaluation of higher gp120 doses. CONCLUSIONS: Although MF59 was expected to enhance immune responses, alum induced similar responses to MF59, suggesting that the choice between these adjuvants may not be critical for the ALVAC+gp120 regimen. TRIAL REGISTRATION: HVTN 107 was registered with the South African National Clinical Trials Registry (DOH-27-0715-4894) and ClinicalTrials.gov (NCT03284710).


Asunto(s)
Vacunas contra el SIDA , Compuestos de Alumbre , Infecciones por VIH , VIH-1 , Polisorbatos , Escualeno , Adulto , Humanos , Adyuvantes Inmunológicos , Vacunas contra el SIDA/efectos adversos , Anticuerpos Anti-VIH , Infecciones por VIH/prevención & control , Inmunogenicidad Vacunal , Inmunoglobulina A , Inmunoglobulina G , Vacunas Combinadas , Vacunas Sintéticas
2.
J Leukoc Biol ; 112(5): 1167-1181, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35866359

RESUMEN

The HIV Vaccine Trials Network (HVTN) conducts clinical trials on 4 continents in pursuit of a safe and effective HIV vaccine. Cellular immune responses to vaccination that define vaccine immunogenicity and/or immune correlates of protection can be measured using multiparameter intracellular cytokine staining (ICS) assays. The HVTN cellular immunology laboratory, located in Seattle, WA, conducts ICS assays for vaccine trials according to Good Clinical Laboratory Practices (GCLP). In 2013, the HVTN established a second GCLP compliant cellular immunology laboratory in Cape Town, South Africa to assess vaccine immunogenicity for HVTN trials conducted on the African continent. To ensure ICS readouts in the 2 laboratories were directly comparable, we conducted concordance testing using PBMC from healthy controls and vaccine trial participants. Despite standardized procedures and instrumentation, shared quality control measures and quality assurance oversight, several factors impacted our ability to obtain close agreement in T-cell responses measured in the 2 laboratories. One of these was the type of fetal bovine serum (FBS) used in the assay, which impacted lymphocyte cell viability and background responses. In addition, the differences in supernatant removal technique also significantly affected our ability to detect positive responses to vaccine antigens. Standardization of these factors allowed us to achieve and maintain ICS assay concordance across the 2 laboratories over multiple years, accelerating our efforts to evaluate HIV vaccines. The insights gained in this process are valuable for assay transfer efforts by groups of investigators that need to directly compare data generated in different laboratories around the globe.


Asunto(s)
Vacunas contra el SIDA , Infecciones por VIH , Humanos , Leucocitos Mononucleares , Albúmina Sérica Bovina , Linfocitos T , Sudáfrica , Infecciones por VIH/prevención & control , Citocinas , Coloración y Etiquetado
3.
J Infect Dis ; 226(2): 246-257, 2022 08 24.
Artículo en Inglés | MEDLINE | ID: mdl-35758878

RESUMEN

BACKGROUND: The ALVAC/gp120 + MF59 vaccines in the HIV Vaccine Trials Network (HVTN) 702 efficacy trial did not prevent human immunodeficiency virus-1 (HIV-1) acquisition. Vaccine-matched immunological endpoints that were correlates of HIV-1 acquisition risk in RV144 were measured in HVTN 702 and evaluated as correlates of HIV-1 acquisition. METHODS: Among 1893 HVTN 702 female vaccinees, 60 HIV-1-seropositive cases and 60 matched seronegative noncases were sampled. HIV-specific CD4+ T-cell and binding antibody responses were measured 2 weeks after fourth and fifth immunizations. Cox proportional hazards models assessed prespecified responses as predictors of HIV-1 acquisition. RESULTS: The HVTN 702 Env-specific CD4+ T-cell response rate was significantly higher than in RV144 (63% vs 40%, P = .03) with significantly lower IgG binding antibody response rate and magnitude to 1086.C V1V2 (67% vs 100%, P < .001; Pmag < .001). Although no significant univariate associations were observed between any T-cell or binding antibody response and HIV-1 acquisition, significant interactions were observed (multiplicity-adjusted P ≤.03). Among vaccinees with high IgG A244 V1V2 binding antibody responses, vaccine-matched CD4+ T-cell endpoints associated with decreased HIV-1 acquisition (estimated hazard ratios = 0.40-0.49 per 1-SD increase in CD4+ T-cell endpoint). CONCLUSIONS: HVTN 702 and RV144 had distinct immunogenicity profiles. However, both identified significant correlations (univariate or interaction) for IgG V1V2 and polyfunctional CD4+ T cells with HIV-1 acquisition. Clinical Trials Registration . NCT02968849.


Asunto(s)
Vacunas contra el SIDA , Infecciones por VIH , Seropositividad para VIH , VIH-1 , Femenino , Anticuerpos Anti-VIH , Proteína gp120 de Envoltorio del VIH , Infecciones por VIH/prevención & control , Humanos , Inmunoglobulina G , Masculino , Sudáfrica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...