Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
3.
Artículo en Inglés | MEDLINE | ID: mdl-37423960

RESUMEN

Before breast cancer surgery, sentinel lymph node (SLN) identification and biopsy using blue dye, radioisotope (RI) with a gamma probe, or a combination of the two are mainly performed. The dye-guided method requires skilled technique to make an incision in the skin and identify SLNs without damaging the lymphatic vessels. In addition, dye-induced anaphylactic shock has been reported. To use the γ-probe-guided method, the facility must be able to handle RI. However, to overcome the drawbacks of these methods, Omoto et al. developed a new identification modality using contrast-enhanced ultrasound with an ultrasound contrast agent (UCA) in 2002. Since then, many basic experiments and clinical studies using various UCA have been reported. In particular, a number of studies in SLN detection using Sonazoid have been reported and are herein reviewed.

4.
J Med Ultrason (2001) ; 50(3): 331-339, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37261555

RESUMEN

It is possible to appropriately diagnose non-mass abnormalities by elucidating ultrasound non-mass abnormality findings and sharing the concept. If non-mass abnormalities can be diagnosed early, the number of curable cases could increase, leading to fewer breast cancer deaths. The Japan Society of Ultrasonics in Medicine (JSUM) Terminology/Diagnostic Criteria Committee has classified non-mass abnormalities into five subtypes: hypoechoic area in the mammary gland, abnormalities of the ducts, architectural distortion, multiple small cysts, and echogenic foci without a hypoechoic area. We herein define the findings for each of these subtypes and present a summary of the JSUM guidelines on non-mass abnormalities of the breast generated based on those findings.


Asunto(s)
Neoplasias de la Mama , Ultrasonido , Femenino , Humanos , Ultrasonografía Mamaria , Japón , Mama/diagnóstico por imagen , Neoplasias de la Mama/diagnóstico por imagen
5.
Medicine (Baltimore) ; 101(43): e31300, 2022 Oct 28.
Artículo en Inglés | MEDLINE | ID: mdl-36316906

RESUMEN

The association between extremely high outlier values (EHOV) of laboratory test items (LTIs) and short-term prognosis or out-of-hospital cardiac arrest (OHCA) remains unclear. This retrospective study investigated the correlation between 72-hour fatality ratios and OHCA ratios in patients with the top 100 EHOV of 57 LTIs without focusing on the disease group and which test items were predictors of 72-hour fatality. This single-center retrospective inception cohort study enrolled patients aged ≥ 18 years who underwent any combination of laboratory tests at the Saitama Medical Center, Japan between January 1, 2008, and December 31, 2013. The primary outcome was the correlation between the 72-hour fatality ratios and OHCA ratios in patients with the top 100 EHOV for 57 LTIs without focusing on the disease group. The LTIs included hematology, blood chemistry, erythrocyte sedimentation, blood coagulation, and arterial blood gas test results. The secondary outcome was which of the 57 LTIs with the top 100 EHOV were more likely to associate with the 72-hour fatality. We evaluated the correlation between the 72-hour fatality ratios and the OHCA ratios for each laboratory test item using the Passing-Bablok regression method. The 72-hour fatality ratios for the top 100 EHOV of 57 LTIs were significantly positively correlated with the OHCA ratios. The regression coefficient of the regression line was 0.394, and the correlation coefficient (95% confidence interval) was 0.644 (0.458-0.775, P < .001). These 72-hour fatality ratios tended to be lower than the OHCA ratios. The top 100 EHOV of 13 LTIs including total bilirubin, direct bilirubin, C-reactive protein, base excess, bicarbonate ion, creatine kinase, uric acid, partial pressure of oxygen, sodium, chloride, blood urea nitrogen, aspartate aminotransferase, and lactate dehydrogenase had 72-hour fatality ratios that were above the upper limit of the linear confidence region of the regression line, with higher 72-hour fatality ratios than the OHCA ratios. The 72-hour fatality ratios for the top 100 EHOV of 57 LTIs tended to be lower than the OHCA ratios. The top 100 EHOV of these 13 LTIs were found to be more likely to associate with 72-hour fatality than OHCA.


Asunto(s)
Reanimación Cardiopulmonar , Paro Cardíaco Extrahospitalario , Humanos , Estudios Retrospectivos , Estudios de Cohortes , Pronóstico , Bilirrubina
6.
Sci Rep ; 12(1): 3119, 2022 02 24.
Artículo en Inglés | MEDLINE | ID: mdl-35210487

RESUMEN

This study aimed to evaluate the diagnostic value of ultrasonographic parameters as an indicator for predicting regional nerve block success. Ultrasound-guided sciatic nerve block was performed in seven dogs using either 2% mepivacaine (nerve-block group) or saline (sham-block group). The cross-sectional area (CSA), nerve blood flow (NBF), and shear wave velocity (SWV) of the sciatic nerve (SWVN), SWV of the biceps femoris muscle (SWVM), and their ratio (SWVNMR) were measured at 0, 30, 60, and 90 min after the nerve block as well as the change rate of each parameter from the baseline. A receiver operating characteristic (ROC) curve analysis was performed to determine the diagnostic value of each parameter in the prediction of nerve block success. No significant changes were observed in the CSA or NBF in association with the nerve block. The SWVN and SWVNMR in the nerve-block group were significantly higher than those in the sham-block group at 90 min and at 30, 60, and 90 min, respectively (p < 0.05). The change rates of SWVN and SWVNMR in the nerve-block group were significantly higher than those in the sham-block group at all time points (p < 0.05). The ROC curve analysis showed that SWVN had a moderate diagnostic accuracy (area under the curve [AUC], 0.779), whereas SWVNMR and change rates of SWVN and SWVNMR had a high diagnostic accuracy (AUC, 0.947, 0.998, and 1.000, respectively). Ultrasonographic evaluation of the SWVN and SWVNMR could be used as indicators for predicting nerve block success.


Asunto(s)
Bloqueo Nervioso/métodos , Ultrasonografía/métodos , Anestésicos Locales , Animales , Área Bajo la Curva , Perros , Predicción/métodos , Inyecciones , Modelos Animales , Datos Preliminares , Curva ROC , Nervio Ciático/diagnóstico por imagen , Resultado del Tratamiento
7.
J Med Ultrason (2001) ; 49(2): 217-230, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35034230

RESUMEN

The concept of point-of-care ultrasound has been widely accepted owing to the development of portable ultrasound systems and growing body of evidence concerning its extensive utility. Thus, it is reasonable to suggest that training to use this modality be included in undergraduate medical education. Training in ultrasonography helps medical students learn basic subjects such as anatomy and physiology, improve their physical examination skills, and acquire diagnostic and procedural skills. Technological advances such as simulators, affordable handheld devices, and tele-ultrasound systems can facilitate undergraduate ultrasound education. Several reports have indicated that some medical schools have integrated ultrasound training into their undergraduate medical curricula. Jichi Medical University in Japan has been providing medical students with ultrasound education to fulfill part of its mission to provide medical care to rural areas. Vertical integration of ultrasound education into a curriculum seems reasonable to ensure skill retention and improvement. However, several issues have hampered the integration of ultrasound into medical education, including a lack of trained faculty, the need to recruit human models, requisition of ultrasound machines for training, and limited curricular space; proposed solutions include peer teaching, students as trained simulated patients, the development of more affordable handheld devices, and a flipped classroom approach with access to an e-learning platform, respectively. A curriculum should be developed through multidisciplinary and bottom-up student-initiated approaches. Formulating national and international consensuses concerning the milestones and curricula can promote the incorporation of ultrasound training into undergraduate medical education at the national level.


Asunto(s)
Educación de Pregrado en Medicina , Curriculum , Humanos , Aprendizaje , Ultrasonografía , Universidades
8.
Cureus ; 13(3): e14119, 2021 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-33912360

RESUMEN

Background Few studies have assessed the relationship between serum total carbon dioxide (CO2) and bicarbonate ion (HCO3 -) concentration in patients undergoing peritoneal dialysis. We determined the agreement between serum total CO2 and HCO3 - concentration and the diagnostic accuracy of serum total CO2 for the prediction of low (HCO3 - <24 mEq/L) and high (HCO3 - ≥24 mEq/L) bicarbonate concentrations in patients on peritoneal dialysis. Methods We collected 245 samples of venous blood from 51 patients on peritoneal dialysis. Independent factors that correlated with the HCO3 - concentration were analyzed using multiple linear regression analysis. The diagnostic accuracy of serum total CO2 was evaluated by receiver operating characteristic (ROC) curve analysis and a 2×2 table. Agreement between serum total CO2 and HCO3 - concentration was assessed by Bland-Altman analysis. Results Serum total CO2 was independently correlated with HCO3 - concentration (ß = 0.354, p < 0.001). The area under the curve of serum total CO2 for the identification of low and high bicarbonate concentrations was 0.909. The diagnostic accuracy of serum total CO2 for the prediction of low and high bicarbonate concentrations was: sensitivity, 91.5%; specificity, 74.7%; positive predictive value, 53.5%; negative predictive value, 96.5%; and accuracy, 78.8%. Bland-Altman analysis showed a moderate agreement between serum total CO2 and HCO3 - concentration. Conclusion Serum total CO2 correlated closely with the HCO3 - concentration in patients undergoing peritoneal dialysis. Serum total CO2 might be useful for predicting low and high bicarbonate in peritoneal dialysis patients.

9.
Medicine (Baltimore) ; 100(4): e24510, 2021 Jan 29.
Artículo en Inglés | MEDLINE | ID: mdl-33530277

RESUMEN

ABSTRACT: The risk factors associated with 72-hours mortality in patients with extremely high levels of random plasma glucose (RPG) remain unclear.To explore the risk factors predictive of 72-hours mortality in patients with extremely high RPG under heterogenos pathophysiological conditions.Retrospective, single-center, case-controlled cross-sectional study.University teaching hospital.Adults over age 18 were selected from the medical records of patients at the Saitama Medical Center, Japan, from 2004 to 2013.Extremely high RPG (≥500 mg/dl).Mortality at 72 hours following the RPG test, regardless of hospitalization or in an outpatient setting. Multivariate logistic regression analysis was performed with adjustment for age, sex, body mass index (BMI), and RPG level. The final prediction model was built using the logistic regression model with a higher C-statistic, specificity, and sensitivity.A total of 351 patients with RPG ≥500 mg/dl were identified within the 10-year period. The 72-hours mortality rate was 16/351 (4.6%). The C-statistics of the 72-hours mortality prediction model with serum albumin (ALB) and creatine kinase (CK) was 0.856. The probability of 72-hours mortality was calculated as follows: 1/[1 + exp (-5.142 + 0.901log (CK) -1.087 (ALB) + 0.293 (presence (1) or absence (0) of metastatic solid tumor)]. The sensitivity and specificity of this model was 75.5%.The independent risk factors associated with 72-hours mortality in patients with RPG ≥500 mg/dl are hypoalbuminemia, elevated CK, and presence of a metastatic solid tumour. Further research is needed to understand the mechanisms and possible interventions to prevent mortality associated with extremely high RPG.


Asunto(s)
Glucemia/análisis , Creatina Quinasa/sangre , Hiperglucemia/mortalidad , Hipoalbuminemia/sangre , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Comorbilidad , Estudios Transversales , Femenino , Humanos , Hiperglucemia/sangre , Hiperglucemia/etiología , Modelos Logísticos , Masculino , Persona de Mediana Edad , Curva ROC , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo
10.
Kidney Res Clin Pract ; 39(4): 441-450, 2020 Dec 31.
Artículo en Inglés | MEDLINE | ID: mdl-32868493

RESUMEN

BACKGROUND: Few studies have investigated the relationship between serum total carbon dioxide (CO2) concentration and bicarbonate ion (HCO3-) concentration in patients undergoing hemodialysis. We determined the agreement and discrepancy between serum total CO2 and HCO3- concentrations and the diagnostic accuracy of serum total CO2 for the prediction of low (HCO3- < 24 mEq/L) and high (HCO3- ≥ 24 mEq/L) bicarbonate concentrations in hemodialysis patients. METHODS: One hundred forty-nine arteriovenous blood samples from 84 hemodialysis patients were studied. Multiple linear regression analysis was used to determine factors correlated with HCO3- concentration. Diagnostic accuracy of serum total CO2 was evaluated using receiver operating characteristic curve analysis and a 2 × 2 table. Agreement between serum total CO2 and HCO3- concentrations was assessed using Bland-Altman analysis. RESULTS: Serum total CO2 concentration was closely correlated with HCO3- concentration (ß = 0.858, P < 0.001). Area under the curve of serum total CO2 for the identification of low and high bicarbonate concentrations was 0.989. Use of serum total CO2 to predict low and high bicarbonate concentrations had a sensitivity of 100%, specificity of 50.0%, positive predictive value of 96.5%, negative predictive value of 100%, and accuracy of 96.6%. Bland-Altman analysis showed moderate agreement between serum total CO2 and HCO3- concentrations. Discrepancies between HCO3- and serum total CO2 concentrations (serum total CO2 - HCO3- ≤ -1) were observed in 89 samples. CONCLUSION: Serum total CO2 concentration is closely correlated with HCO3- concentration in hemodialysis patients. However, there is a non-negligible discrepancy between serum total CO2 and HCO3- concentrations.

11.
Kidney Res Clin Pract ; 38(3): 326-335, 2019 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-31378012

RESUMEN

BACKGROUND: We investigated the relationship between serum total carbon dioxide (CO2) and bicarbonate ion (HCO3-) concentrations in pre-dialysis chronic kidney disease (CKD) patients and devised a formula for predicting low bicarbonate (HCO3- < 24 mmol/L) and high bicarbonate (HCO3- ≥ 24 mmol/L) using clinical parameters. METHODS: In total, 305 samples of venous blood collected from 207 pre-dialysis patients assessed by CKD stage (G1 + G2, 46; G3, 50; G4, 51; G5, 60) were investigated. The relationship between serum total CO2 and HCO3- concentrations was analyzed using Pearson's correlation coefficient. An approximation formula was developed using clinical parameters correlated independently with HCO3- concentration. Diagnostic accuracy of serum total CO2 and the approximation formula was evaluated by receiver operating characteristic curve analysis and a 2 × 2 table. RESULTS: Serum total CO2 correlated strongly with HCO3- concentration (r = 0.91; P < 0.001). The following approximation formula was obtained by a multiple linear regression analysis: HCO3- (mmol/L) = total CO2 - 0.5 × albumin - 0.1 × chloride - 0.01 × (estimated glomerular filtration rate + blood glucose) + 15. The areas under the curves of serum total CO2 and the approximation formula for detection of low bicarbonate and high bicarbonate were 0.981, 0.996, 0.993, and 1.000, respectively. This formula had superior diagnostic accuracy compared with that of serum total CO2 (86.6% vs. 81.3%). CONCLUSION: Serum total CO2 correlated strongly with HCO3- concentration in pre-dialysis CKD patients. An approximation formula including serum total CO2 showed superior diagnostic accuracy for low and high bicarbonate compared with serum total CO2.

12.
J Clin Ultrasound ; 47(7): 426-431, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30762237

RESUMEN

Leiomyosarcoma of the inferior vena cava is a rare malignant tumor originating from smooth muscle cells of the vascular media. Its preoperative diagnosis by conventional noninvasive examinations such as abdominal ultrasonography, X-ray computed tomography, and magnetic resonance imaging, may be difficult because of their nonspecific findings. We present the case of a 72-year-old woman with leiomyosarcoma of the inferior vena cava diagnosed by intravascular ultrasonography.


Asunto(s)
Leiomiosarcoma/diagnóstico por imagen , Neoplasias Vasculares/diagnóstico por imagen , Vena Cava Inferior/diagnóstico por imagen , Anciano , Femenino , Humanos , Leiomiosarcoma/patología , Leiomiosarcoma/cirugía , Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X , Ultrasonografía , Neoplasias Vasculares/patología , Neoplasias Vasculares/cirugía , Vena Cava Inferior/patología
13.
Acta Otolaryngol ; 139(1): 94-99, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30676845

RESUMEN

BACKGROUND: In sentinel lymph node (SLN) biopsy for head and neck cancers, the radioisotope method has been the gold standard. However, this method has several problems, such as unavoidable radiation exposure and requirements of expensive equipment. AIMS/OBJECTIVES: To overcome these problems, we evaluated the contrast-enhanced ultrasonography (CEUS)-guided SLN-detection method, and predicted the SLN metastatic status using novel ultrasound technology, superb microvascular imaging (SMI). METHODS: Ten patients (6 with oral and 4 with oropharyngeal cancers) without neck lymph node metastasis were enrolled in this study. Ultrasound contrast agent, Sonazoid™, was infiltrated into the mucosa at the primary site to observe the lymphatic ducts and SLNs in the neck field. The detected SLNs were examined for blood flow using SMI to categorize the SLNs metastases-positive or negative. RESULTS: SLNs were successfully detected in 8 out of 10 cases. In 7 out of the 8 cases, in whom SLNs were successfully detected, the metastatic status of SLNs was correctly diagnosed with SMI. CONCLUSIONS AND SIGNIFICANCE: Although more clinical data are needed based on a larger cohort, establishing the CEUS-guided SLN-detection and criteria for the accurate diagnosis of SLN-metastases using SMI would be valuable as an alternative to radioisotope method, in oral and oropharyngeal cancers.


Asunto(s)
Medios de Contraste , Compuestos Férricos , Hierro , Neoplasias Orofaríngeas/diagnóstico por imagen , Óxidos , Ganglio Linfático Centinela/diagnóstico por imagen , Ultrasonografía , Adulto , Anciano , Femenino , Humanos , Metástasis Linfática , Masculino , Microvasos/diagnóstico por imagen , Persona de Mediana Edad , Neoplasias Orofaríngeas/irrigación sanguínea , Proyectos Piloto
14.
Springerplus ; 4: 509, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26405629

RESUMEN

Breast cancer is the most common type of cancer in women. The 5-year survival rate in patients with breast cancer ranges from 74 to 82 %. Sentinel lymph node biopsy has become an alternative to axillary lymph node dissection for nodal staging. We evaluated the detection of the sentinel lymph node and metastasis of the lymph node using contrast enhanced ultrasonography with Sonazoid. Between December 2013 and May 2014, 32 patients with operable breast cancer were enrolled in this study. We evaluated the detection of axillary sentinel lymph nodes and the evaluation of axillary lymph nodes metastasis using contrast enhanced computed tomography, color Doppler ultrasonography and contrast enhanced ultrasonography with Sonazoid. All the sentinel lymph nodes were identified, and the sentinel lymph nodes detected by contrast enhanced ultrasonography with Sonazoid corresponded with those detected by computed tomography lymphography and indigo carmine method. The detection of metastasis based on contrast enhanced computed tomography were sensitivity 20.0 %, specificity 88.2 %, PPV 60.0 %, NPV 55.6 %, accuracy 56.3 %. Based on color Doppler ultrasonography, the results were sensitivity 36.4 %, specificity 95.2 %, PPV 80.0 %, NPV 74.1 %, accuracy 75.0 %. Based on contrast enhanced ultrasonography with Sonazoid, the results were sensitivity 81.8 %, specificity 95.2 %, PPV 90.0 %, NPV 90.9 %, accuracy 90.6 %. The results suggested that contrast enhanced ultrasonography with Sonazoid was the most accurate among the evaluations of these modalities. In the future, we believe that our method would take the place of conventional sentinel lymph node biopsy for an axillary staging method.

15.
J Ultrasound Med ; 33(7): 1299-303, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24958418

RESUMEN

This report documents 3 pediatric papillary thyroid carcinoma cases with associated Hashimoto thyroiditis. In all 3 cases, hypoechoic nodules accompanied by multiple echogenic spots were noted on sonography of the thyroid. Hashimoto thyroiditis was suspected on the basis of positive thyroid autoantibody test results and pathologic examinations of thyroidectomy specimens, which revealed chronic thyroiditis with lymphocytic infiltration as the background of papillary thyroid carcinoma development. The potential for papillary carcinoma development warrants close follow-up, and meticulous sonographic examinations must be performed in children with Hashimoto thyroiditis.


Asunto(s)
Carcinoma/diagnóstico por imagen , Carcinoma/epidemiología , Enfermedad de Hashimoto/diagnóstico por imagen , Enfermedad de Hashimoto/epidemiología , Neoplasias de la Tiroides/diagnóstico por imagen , Neoplasias de la Tiroides/epidemiología , Adolescente , Biopsia con Aguja Fina , Carcinoma/patología , Carcinoma Papilar , Niño , Comorbilidad , Femenino , Enfermedad de Hashimoto/patología , Humanos , Cáncer Papilar Tiroideo , Neoplasias de la Tiroides/patología , Ultrasonografía
16.
AJR Am J Roentgenol ; 202(4): W400-7, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24660739

RESUMEN

OBJECTIVE: The objective of our study was to compare the efficacy of contrast-enhanced ultrasound (CEUS) using the ultrasound contrast agent Sonazoid (perflubutane) with unenhanced ultrasound and supplementary contrast-enhanced MRI in the differential diagnosis (benign vs malignant) of focal breast lesions. The safety of Sonazoid was also assessed in this study. SUBJECTS AND METHODS: A total of 127 patients with focal breast lesions were enrolled in this study at five centers in Japan. Three reviewers who were blinded to the patient characteristics independently assessed the ultrasound images and MR images in a randomized sequence. The accuracy, sensitivity, and specificity of CEUS, unenhanced ultrasound, and supplementary contrast-enhanced MRI for the differential diagnosis were compared using generalized estimating equation analyses. Diagnostic confidence was also assessed. RESULTS: The accuracy of CEUS was significantly higher than that of unenhanced ultrasound (87.2% vs 65.5%, respectively; p < 0.001). In addition, CEUS showed significantly higher specificity, although the improvement in sensitivity was not statistically significant. The accuracy and specificity were significantly higher with CEUS than with contrast-enhanced MRI, but the improvement in sensitivity was not statistically significant. The area under the curve in a receiver operating characteristic analysis was significantly greater with CEUS than with unenhanced ultrasound. The incidence of adverse events was 11.4% and the incidence of adverse drug reactions was 3.3%. All adverse drug reactions were mild. CONCLUSION: CEUS using Sonazoid was confirmed to be superior to unenhanced ultrasound for the differential diagnosis (benign vs malignant) of focal breast lesions in terms of diagnostic accuracy with no serious adverse reactions.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Medios de Contraste , Compuestos Férricos , Hierro , Óxidos , Ultrasonografía Mamaria , Adulto , Anciano , Neoplasias de la Mama/patología , Diagnóstico Diferencial , Femenino , Gadolinio DTPA , Humanos , Imagen por Resonancia Magnética , Meglumina , Persona de Mediana Edad , Compuestos Organometálicos , Sensibilidad y Especificidad
17.
Case Rep Vasc Med ; 2014: 479656, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25610701

RESUMEN

Pseudoaneurysms (PsA) and arteriovenous fistulae (AVF) of the thyrocervical trunk and its branches are rare complications of traumatic or iatrogenic arterial injuries. Most such injuries are iatrogenic and are associated with central venous catheterization. Historically, thyrocervical trunk PsA and AVF have been managed with open surgical repair; however, multiple treatment modalities are now available, including ultrasound-guided compression repair, ultrasound-guided thrombin injection, and endovascular repair with covered stent placement. We report a case of a 65-year-old woman with an iatrogenic thyrocervical trunk PsA with concomitant AVF that developed after attempted internal jugular vein cannulation for hemodialysis access. The PsA was successfully treated by transcatheter coil embolization using 0.010-inch detachable microcoils. Our case is the first published instance of a thyrocervical trunk PsA with concomitant AVF that was successfully treated by endovascular procedure.

18.
J Med Ultrason (2001) ; 41(4): 439-43, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27278024

RESUMEN

PURPOSE: To evaluate whether the onion skin sign on ultrasonography (US) of the lower abdomen is specific for the diagnosis of an appendiceal mucocele. METHODS: Our study included 231 lesions from 229 patients in whom transabdominal US detected lesions in the lower abdomen and who had definitive pathological diagnoses in the small bowel, ileocecal valve, cecum, appendix, mesentery, adnexa uteri or pelvic cavity outside the major organs. Patients with metastatic tumors were excluded. We reviewed the reports and images from transabdominal US and checked for the presence of the onion skin sign. The sensitivity, specificity, and accuracy of the sign for the diagnosis of an appendiceal mucocele were calculated. RESULTS: Five (2.2 %) of the 231 lesions showed the onion skin sign on US and all were diagnosed with an appendiceal mucocele. The sensitivity, specificity, and accuracy of the sign for the diagnosis of an appendiceal mucocele were 63, 100, and 99 %, respectively. CONCLUSIONS: The onion skin sign in the lower abdomen appears to be specific for the diagnosis of an appendiceal mucocele. In cases where the onion skin sign is obviously present in the lower abdomen on US, an appendiceal mucocele should be considered as the leading diagnosis.


Asunto(s)
Apéndice/diagnóstico por imagen , Enfermedades del Ciego/diagnóstico por imagen , Mucocele/diagnóstico por imagen , Ultrasonografía , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Diagnóstico Diferencial , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad , Adulto Joven
20.
Rinsho Byori ; 60(9): 895-9, 2012 Sep.
Artículo en Japonés | MEDLINE | ID: mdl-23157120

RESUMEN

Ultrasonography, one of the physiological function examinations, is essential to practical medicine. It is superior to CT and MRI in safety, as well as real-time and spatial resolution. Diagnostic ultrasound is usually performed in B-mode and Doppler-mode. In addition to these modes, elastography and contrast-enhanced ultrasonography have sometimes been used for further examination. Recently, ultrasonography with a new application for diagnosis and therapy and unique technology are being watched with interest. The current status and view of the future regarding abdominal and superficial organ ultrasonography will be introduced.


Asunto(s)
Abdomen/diagnóstico por imagen , Aumento de la Imagen/métodos , Imagenología Tridimensional/métodos , Ultrasonografía/métodos , Diagnóstico por Imagen de Elasticidad/métodos , Humanos , Imagen por Resonancia Magnética/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA