Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Oncotarget ; 8(14): 22550-22562, 2017 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-28186980

RESUMEN

Obesity increases cancer risk including breast cancer (BC). However, the direct regulatory mechanisms by which obesity promotes BC progression remain largely unknown. We show that lysophosphatidic acid/protein kinase D1 (LPA/PKD-1)-CD36 signaling is a bona fide breast cancer promoter via stimulating microvascular remodeling in chronic diet-induced obesity (DIO). We observed that the growth of an estrogen receptor (ER) positive breast cancer was markedly increased when compared to the lean control, and specifically accompanied by increased microvascular remodeling in a syngeneic BC model in female DIO mice. The tumor neovessels in DIO mice demonstrated elevated levels of alpha smooth muscle actin (α-SMA), vascular endothelial growth factor receptor 2 (VEGFR 2) and endothelial differentiation gene 2/LPA receptor1 (Edg2/LPA1), enhanced PKD-1 phosphorylation, and reduced CD36 expression. Tumor associated endothelial cells (TAECs) exposed to LPA demonstrated sustained nuclear PKD-1 phosphorylation, and elevated mRNA levels of ephrin B2, and reduced mRNA expression of CD36. TAEC proliferation also increased in response to LPA/PKD-1 signaling. These studies suggest that the LPA/PKD-1-CD36 signaling axis links DIO to malignant progression of BC via stimulation of de novo tumor arteriogenesis through arteriolar remodeling of microvasculature in the tumor microenvironment. Targeting this signaling axis could provide an additional novel therapeutic strategy.


Asunto(s)
Neoplasias de la Mama/metabolismo , Antígenos CD36/metabolismo , Endotelio Vascular/metabolismo , Lisofosfolípidos/metabolismo , Obesidad/metabolismo , Proteína Quinasa C/metabolismo , Remodelación Vascular , Animales , Neoplasias de la Mama/epidemiología , Antígenos CD36/genética , Carcinogénesis , Proliferación Celular , Células Cultivadas , Dieta , Modelos Animales de Enfermedad , Endotelio Vascular/patología , Femenino , Humanos , Ratones , Ratones Endogámicos C57BL , Obesidad/epidemiología , Receptores de Estrógenos/genética , Receptores de Estrógenos/metabolismo , Riesgo , Transducción de Señal
2.
Microsc Microanal ; 19(6): 1653-68, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24103552

RESUMEN

As part of an ongoing effort to increase image reproducibility and fidelity in addition to improving cross-instrument consistency, we have proposed using four separate instrument quality tests to augment the ones we have previously reported. These four tests assessed the following areas: (1) objective lens quality, (2) resolution, (3) accuracy of the wavelength information from spectral detectors, and (4) the accuracy and quality of spectral separation algorithms. Data were received from 55 laboratories located in 18 countries. The largest source of errors across all tests was user error which could be subdivided between failure to follow provided protocols and improper use of the microscope. This truly emphasizes the importance of proper rigorous training and diligence in performing confocal microscopy experiments and equipment evaluations. It should be noted that there was no discernible difference in quality between confocal microscope manufactures. These tests, as well as others previously reported, will help assess the quality of confocal microscopy equipment and will provide a means to track equipment performance over time. From 62 to 97% of the data sets sent in passed the various tests demonstrating the usefulness and appropriateness of these tests as part of a larger performance testing regiment.


Asunto(s)
Microscopía Confocal/instrumentación , Microscopía Confocal/normas , Cooperación Internacional , Microbiología/educación
3.
Microsc Microanal ; 17(4): 598-606, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21477410

RESUMEN

The days of being able to ascertain instrument performance by simply peering through the eye pieces at a specimen are gone. However, users and granting agencies need to be confident that data collected on these instruments is uniform and quantifiable both over time and between instruments. Ideally, a LASER should not fluctuate, illumination should be completely uniform, and colors should be perfectly aligned. To check the current performance of imaging equipment, we conducted a worldwide research study utilizing three image-based tests: long-/short-term illumination stability, co-registration of signals across various wavelengths, and field illumination uniformity. To differentiate between "acceptable" and "unacceptable" performance, the deviation in illumination power could not exceed 10% (long term) or 3% (short term), the difference in the center-of-mass of imaged multicolored beads could not exceed >1 pixel between different wavelengths, and field illumination values could not exceed 10% (horizontal) or 20% (diagonal) deviation. This study established the current state of microscope performance through simple, efficient, and robust tests, while defining relative standards to assist cores in maintaining their instruments in optimal operating conditions. We developed cross-platform performance standards that will improve the validity of quantitative measurements made using various light microscopes.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA