1.
Acta Orthop Traumatol Turc ; 57(4): 134-140, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37670446

RESUMEN

OBJECTIVE: This study aimed to introduce a method to extract the 3-dimensional spatial position of the femoral head implant from 2-dimensional fluoroscopic projections, allowing surgeons to assess fixation much more accurately and prevent cut-out complications in proximal femoral nailing. METHODS: To define a safety region for the tip in the femoral head, a novel 3-dimensional distance-based risk parameter called TSD3D was introduced. An intersection algorithm was developed that solely takes the fluoroscopic anteroposterior and lateral distances to reveal the 3-dimensional location of the screw or Kirschner wire tip, enabling the utilization of the 3-dimensional parameter. Orthogonal per- spectives of 6 femur proximal bone substitutes with randomly inserted Kirschner wires were imaged under fluoroscopy. The developed algorithm was used to calculate the implant tip location in 3-dimensional from 2-dimensional images for each case. Algorithm accuracy was validated with the computed tomography-obtained 3-dimensional models of the same femur substitutes. RESULTS: The newly introduced risk parameter successfully visualizes 3-dimensional safety regions. Utilizing the 2-dimensional fluoro- scopic distances as inputs to the algorithm, the 3-dimensional position of the implanted Kirschner wire tip is calculated with a maximum of 9.8% error for a single Cartesian-coordinate measurement comparison. CONCLUSION: By incorporating the newly introduced 3-dimensional risk parameter, surgeons can more precisely evaluate the position of the implant and avoid cut-out complications, instead of relying solely on misleading 2-dimensional fluoroscopic projections of the femoral head.


Asunto(s)
Cabeza Femoral , Cirujanos , Humanos , Fémur , Fluoroscopía , Tornillos Óseos
2.
J Mech Behav Biomed Mater ; 124: 104847, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34555620

RESUMEN

BACKGROUND: Inventory management or immediate availability of fracture plates can be problematic since for each surgical intervention a specific plate of varying size and functionality must be ordered. Modularization of the standard monolithic plate is proposed to address this issue. METHODS: The effects of four different unit module design parameters (type, degree of modularization, connector screw diameter, sandwich ratio) on the plate bending stiffness and failure are investigated in a finite element four-point-bending analysis. A chosen, best-performing modular plate is then tested in silico for a simple diaphyseal tibial fracture scenario under anatomical compressional, torsional, and bending loads. RESULTS: A modularization strategy is proposed to match the monolithic plate bending properties as closely as possible. With the best combination of design parameters, a fully modularized equivalent length plate with a 42.3% decrease in stiffness and 46.2% decrease in strength could be assembled. The chosen modular plate also displayed sufficient mechanical performance under the fracture fixation scenarios for a potentially successful osteosynthesis. CONCLUSIONS: Via computational methods, the viability of the modularization strategy as an alternate to the traditional monolithic plate is demonstrated. As a further realized advantage, the modular plates can alleviate stress shielding thanks to the reduced stiffness.


Asunto(s)
Placas Óseas , Fracturas Óseas , Fenómenos Biomecánicos , Simulación por Computador , Fijación Interna de Fracturas , Humanos
3.
J Biomech Eng ; 143(9)2021 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-33876208

RESUMEN

BACKGROUND: AISI 316 L stainless steel wire cerclage routinely used in sternotomy closure causes lateral cut-through damage and fracture, especially in cases of high-risk patients, which leads to postoperative complications. A biocompatible elastomer (Pellethane®) coating on the standard wire is proposed to mitigate the cut-through effect. METHODS: Simplified peri-sternal and transsternal, sternum-cerclage contact models are created and statically analyzed in a finite element (FE) software to characterize the stress-reduction effect of the polymer coating for thicknesses between 0.5 and 1.125 mm. The performance of the polymer-coated cerclage in alleviating the detrimental cortical stresses is also compared to the standard steel cerclage in a full sternal closure FE model for the extreme cough loading scenario. RESULTS: It was observed via the simplified contact simulations that the cortical stresses can be substantially decreased by increasing the coating thickness. The full closure coughing simulation on the human sternum further corroborated the simplified contact results. The stress reduction effect was found to be more prominent in the transsternal contacts in comparison to peri-sternal contacts. CONCLUSIONS: Bearing in mind the promising numerical simulation results, it is put forth that a standard steel wire coated with Pellethane will majorly address the cut-through complication.


Asunto(s)
Esternón
4.
Injury ; 50(10): 1612-1619, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31455505

RESUMEN

A novel Ti6Al4V adjustable locking plate (ALP) is designed to provide enhanced bone stability for segmental bone fractures and to allow precise positioning of disconnected segments. The design incorporates an adjustable rack and pinion mechanism to perform compression, distraction and segment transfer during plate fixation surgery. The aim of this study is to introduce the advantages of the added feature and computationally characterize the biomechanical performance of the proposed design. Structural strength of the novel plate is analyzed using numerical methods for 4-point bending and fatigue properties, following ASTM standards. An additional mechanical failure finite element test is also conducted on the rack and pinion to reveal how much torque can be safely applied to the mechanism by the surgeon. Simulation results predict that the new design is sufficiently strong to not fail under regular anatomical loading scenarios with close bending strength and fatigue life properties to clinically used locking compression plates. The novel ALP design is expected to be a good candidate for addressing problems regarding fixation of multi-fragmentary bone fractures.


Asunto(s)
Placas Óseas , Simulación por Computador , Análisis de Elementos Finitos , Fijación Intramedular de Fracturas/instrumentación , Fracturas del Húmero/cirugía , Aleaciones , Fenómenos Biomecánicos , Tornillos Óseos , Fuerza Compresiva , Diseño de Equipo , Humanos , Ensayo de Materiales , Titanio , Torque
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...