Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Microsurgery ; 44(2): e31136, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38342995

RESUMEN

INTRODUCTION: Above elbow transplants represent 19% of the upper extremity transplants. Previous large-animal models have been too distal or heterotopic, did not use immunosuppression and had short survival. We hypothesize that an orthotopic forelimb transplant model, under standard immunosuppression, is feasible and can be used to address questions on peri-transplant ischemia reperfusion injury, and post-transplantation vascular, immunologic, infectious, and functional outcomes. MATERIALS AND METHODS: Four forelimbs were used for anatomical studies. Four mock transplants were performed to establish technique/level of muscle/tendon repairs. Four donor and four recipient female Yucatan minipigs were utilized for in-vivo transplants (endpoint 90-days). Forelimbs were amputated at the midarm and preserved through ex vivo normothermic perfusion (EVNP) utilizing an RBC-based perfusate. Hourly perfusate fluid-dynamics, gases, electrolytes were recorded. Contractility during EVNLP was graded hourly using the Medical Research Council scale. EVNP termination criteria included systolic arterial pressure ≥115 mmHg, compartment pressure ≥30 mmHg (at EVNP endpoint), oxygen saturation reduction of 20%, and weight change ≥2%. Indocyanine green (ICG) angiography was performed after revascularization. Limb rejection was evaluated clinically (rash, edema, temperature), and histologically (BANFF classification) collecting per cause and protocol biopsies (POD 1, 7, 30, 60 and endpoint). Systemic infections were assessed by blood culture and tissue histology. CT scan was used to confirm bone bridging at endpoint. RESULTS: Animals 2, 4 reached endpoint with grade 0-I rejection. Limbs 1, 3 presented grade III rejection on days 6, 61. CsA troughs averaged 461 ± 189 ng/mL. EVNLP averaged 4.3 ± 0.52 h. Perfusate lactate, PO2 , and pH were 5.6 ± 0.9 mmol/L, 557 ± 72 mmHg and 7.5 ± 0.1, respectively. Muscle contractions were 4 [1] during EVNLP. Transplants 2, 3, 4 showed bone bridging on CT. CONCLUSION: We present preliminary evidence supporting the feasibility of an orthotopic, mid-humeral forelimb allotransplantation model under standard immunosuppression regimen. Further research should validate the immunological, infectious, and functional outcomes of this model.


Asunto(s)
Miembro Anterior , Extremidad Superior , Porcinos , Animales , Femenino , Porcinos Enanos , Miembro Anterior/cirugía , Miembro Anterior/irrigación sanguínea , Modelos Animales , Contracción Muscular
2.
Transplantation ; 106(8): 1638-1646, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35152257

RESUMEN

BACKGROUND: Ischemia-reperfusion injury remains a primary concern in upper extremity transplantation. Ex vivo normothermic perfusion (EVNP) enables near-physiological organ preservation, avoiding the deleterious effects of hypoxia and cooling. We investigated the effectiveness of human limb EVNP compared with static cold storage (SCS). METHODS: Twenty human upper extremities were procured. Ten were perfused at 38 °C with an oxygenated red blood cell-based solution, and contralateral limbs served as SCS control (4 °C). EVNP was terminated with systolic arterial pressure ≥115 mm Hg, compartment fullness, or a 20% decline in oxygen saturation. Weight, contractility, compartment pressure, tissue oxygen saturation, and uptake rates were assessed. Perfusate fluid dynamics, gases, electrolytes, and metabolites were measured. Myocyte injury scores and liquid chromatography-mass spectrometry analysis were performed. RESULTS: EVNP duration was 41.6 ± 9.4 h. Vascular resistance averaged 173.0 ± 29.4 mm Hg × min/L. Weight change and compartment pressures were 0.4 ± 12.2% ( P = 0.21) and 21.7 ± 15.58 mm Hg ( P = 0.003), respectively. Arterial and venous carbon dioxide partial pressure, oxygen saturation, and pH were 509.5 ± 91.4 mm Hg, 15.7 ± 30.2 mm Hg, 87.4 ± 11.4%, and 7.3 ± 0.2, respectively. Oxygen uptake rates averaged 5.7 ± 2.8 mL/min/g. Lactate reached 20 mmol/L after 15 (interquartile range = 6) h. Limb contractility was preserved for 30.5 (interquartile range = 15.8) h ( P < 0.001) and negatively correlated with perfusate potassium (ρ = -0.7, P < 0.001). Endpoint myocyte injury scores were 28.9 ± 11.5% (EVNP) and 90.2 ± 11.8% (SCS) ( P < 0.001). A significant increase in taurine ( P = 0.002) and decrease in tryptophan ( P = 0.002) were detected. Infrared thermography and indocyanine green angiography confirmed the presence of peripheral perfusion. CONCLUSIONS: EVNP can overcome the limitations of cold preservation by extending preservation times, enabling limb quality assessment, and allowing limb reconditioning before transplantation.


Asunto(s)
Soluciones Preservantes de Órganos , Preservación de Órganos , Circulación Extracorporea , Humanos , Preservación de Órganos/métodos , Soluciones Preservantes de Órganos/farmacología , Perfusión/métodos , Extremidad Superior
3.
J Trauma Acute Care Surg ; 92(2): 388-397, 2022 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-34510075

RESUMEN

BACKGROUND: Ex vivo normothermic limb perfusion (EVNLP) preserves amputated limbs under near-physiologic conditions. Perfusates containing red blood cells (RBCs) have shown to improve outcomes during ex vivo normothermic organ perfusion, when compared with acellular perfusates. To avoid limitations associated with the use of blood-based products, we evaluated the feasibility of EVNLP using a polymerized hemoglobin-based oxygen carrier-201 (HBOC-201). METHODS: Twenty-four porcine forelimbs were procured from Yorkshire pigs. Six forelimbs underwent EVNLP with an HBOC-201-based perfusate, six with an RBC-based perfusate, and 12 served as static cold storage (SCS) controls. Ex vivo normothermic limb perfusion was terminated in the presence of systolic arterial pressure of 115 mm Hg or greater, fullness of compartments, or drop of tissue oxygen saturation by 20%. Limb contractility, weight change, compartment pressure, tissue oxygen saturation, oxygen uptake rates (OURs) were assessed. Perfusate fluid-dynamics, gases, electrolytes, metabolites, methemoglobin, creatine kinase, and myoglobin concentration were measured. Uniformity of skin perfusion was assessed with indocyanine green angiography and infrared thermography. RESULTS: Warm ischemia time before EVNLP was 35.50 ± 8.62 minutes (HBOC-201), 30.17 ± 8.03 minutes (RBC) and 37.82 ± 10.45 (SCS) (p = 0.09). Ex vivo normothermic limb perfusion duration was 22.5 ± 1.7 hours (HBOC-201) and 28.2 ± 7.3 hours (RBC) (p = 0.04). Vascular flow (325 ± 25 mL·min-1 vs. 444.7 ± 50.6 mL·min-1; p = 0.39), OUR (2.0 ± 1.45 mL O2·min-1·g-1 vs. 1.3 ± 0.92 mL O2·min-1·g-1 of tissue; p = 0.80), lactate (14.66 ± 4.26 mmol·L-1 vs. 13.11 ± 6.68 mmol·L-1; p = 0.32), perfusate pH (7.53 ± 0.25 HBOC-201; 7.50 ± 0.23 RBC; p = 0.82), flexor (28.3 ± 22.0 vs. 27.5 ± 10.6; p = 0.99), and extensor (31.5 ± 22.9 vs. 28.8 ± 14.5; p = 0.82) compartment pressures, and weight changes (23.1 ± 3.0% vs. 13.2 ± 22.7; p = 0.07) were not significantly different between HBOC-201 and RBC groups, respectively. In HBOC-201 perfused limbs, methemoglobin levels increased, reaching 47.8 ± 12.1% at endpoint. Methemoglobin saturation did not affect OUR (ρ = -0.15, r2 = 0.022; p = 0.45). A significantly greater number of necrotic myocytes was found in the SCS group at endpoint (SCS, 127 ± 17 cells; HBOC-201, 72 ± 30 cells; RBC-based, 56 ± 40 cells; vs. p = 0.003). CONCLUSION: HBOC-201- and RBC-based perfusates similarly support isolated limb physiology, metabolism, and function.


Asunto(s)
Miembro Anterior/irrigación sanguínea , Hemoglobinas/farmacología , Preservación de Órganos/métodos , Perfusión/métodos , Animales , Transfusión de Eritrocitos , Estudios de Factibilidad , Porcinos
4.
J Surg Res ; 268: 354-362, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34403855

RESUMEN

BACKGROUND: Histomorphometry quantitatively evaluates nerve regeneration. Total myelinated fiber count (TMFC) is most accurately obtained manually across full nerve cross-sections, but most researchers opt for automated, sampled analysis. Few of the numerous techniques available have been validated. The goal of this study was to compare common histomorphometric methods (full manual [FM], sampled manual [SM], and sampled automatic [SA]) to determine their reliability and consistency. MATERIAL AND METHODS: Twenty-four rats underwent sciatic nerve (SN) repair with 20mm isografts; SNs distal to the graft were analyzed. TMFC was manually determined in each full cross-section. Counts were also extrapolated from sampled fields, both manually and automatically with ImageJ software. Myelinated fiber diameter, axon diameter, and myelin sheath thickness were measured manually in full and sampled fields; G-ratio was calculated. Repeated-measures MANOVA, Spearman correlation, and Wilcoxon signed-rank tests were performed. A systematic review of histomorphometry in rat SN repair was performed to analyze the variability of techniques in the literature. RESULTS: FM TMFC was 13,506 ± 4,217. Both sampled methods yielded significantly different TMFCs (SM:14.4 ± 13.4%, P< 0.001; SA:21.8 ± 44.7%, P = 0.037). All three methods strongly correlated with each other, especially FM and SM (rs = 0.912, P< 0.001). FM fiber diameter, axon diameter, and myelin sheath thickness did not differ from SM (P = 0.493, 0.209, and 0.331, respectively). 65% of papers used sampling; 78% utilized automated or semi-automated analysis. Software, sampling, and histomorphometric parameters varied widely. CONCLUSION: SM and SA analysis are reliable with standardized, systematic sampling. Transparency is essential to allow comparison of data; meanwhile, researchers must be cognizant of the wide variety of methodologies in the literature.


Asunto(s)
Axones , Regeneración Nerviosa , Animales , Axones/fisiología , Vaina de Mielina/fisiología , Ratas , Reproducibilidad de los Resultados , Nervio Ciático/cirugía
5.
Aesthet Surg J ; 41(12): NP1989-NP1993, 2021 11 12.
Artículo en Inglés | MEDLINE | ID: mdl-33843982

RESUMEN

BACKGROUND: Photographic images can clash markedly with patients' self-perception. Individuals are more familiar with their mirror image, where their facial asymmetries are reversed. A non-reversing mirror (NRM) allows patients to see their dynamic non-reversed image and familiarize themselves with how they appear in photographs and to others. OBJECTIVES: The aim of this study was to explore the effect that a NRM has on facial self-perception and investigate whether a NRM changes an individual's goals when considering cosmetic surgery. METHODS: Individuals (n = 30) filled out portions of the FACE-Q questionnaire after inspecting their reflections in a NRM and in a standard mirror for 30 seconds each. After these two inspections had been completed, investigators asked qualitative questions comparing the 2 mirrors. Wilcoxon signed-rank test, Mann-Whitney U test, and Pearson's chi-squared test were used to analyze the differences. RESULTS: Participants scored significantly better on the FACE-Q Age Appraisal and Appearance-Related Psychosocial Distress scales when looking in a standard mirror vs a NRM (P = 0.007 and 0.001, respectively). Qualitatively, most reported that their faces seemed less symmetric and less balanced (73% and 53%, respectively) in the NRM. Overall, 83.3% reported seeing a qualitative difference in their appearance, with 30% endorsing that looking in the NRM had changed their facial aesthetic goals. CONCLUSIONS: A NRM can bridge between the familiarity of the patient's reversed reflection and their less-familiar, non-reversed true image. It may serve as a useful physician-patient communication tool when discussing goals and expectations for facial aesthetic procedures.


Asunto(s)
Procedimientos de Cirugía Plástica , Autoimagen , Humanos , Encuestas y Cuestionarios
6.
Ann Plast Surg ; 86(6): 726-730, 2021 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-33074836

RESUMEN

ABSTRACT: Breast augmentation is among the most commonly performed cosmetic procedures in the United States. As these patients age or develop comorbidities, surgeons across many other disciplines will inevitably encounter these patients in their own practices. Consequently, surgeons must be aware of the potential interactions between breast implants and devices commonly used in their fields. This case, the second of its kind encountered by our own department, describes a woman who suffered one such interaction: migration and coiling of a ventriculoperitoneal shunt around her breast implant. A systematic review was conducted to characterize breast-related ventriculoperitoneal shunt complications reported in the literature and generate an algorithm for management of the most commonly reported scenarios. Recognition of potential complications will aid surgeons in appropriate operative planning and prevention of these adverse events.


Asunto(s)
Implantación de Mama , Implantes de Mama , Mamoplastia , Mama , Implantación de Mama/efectos adversos , Implantes de Mama/efectos adversos , Femenino , Humanos , Estados Unidos , Derivación Ventriculoperitoneal/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...