Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
2.
Digestion ; 102(5): 714-721, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33352560

RESUMEN

BACKGROUND: Endoscopic submucosal dissection (ESD) is recognized as a minimally invasive and curative treatment for superficial gastrointestinal (GI) cancers. However, ESD is still challenging and time-consuming with a high risk of adverse events such as bleeding and perforation. Various traction methods have been explored for maintaining good visualization of the submucosal layer during ESD. We developed a novel traction device (the EndoTrac) which can easily tie the thread and has the ability to change the towing direction. The aim of this study is to evaluate safety and feasibility of ESD using the EndoTrac for GI neoplasms. PATIENTS AND METHODS: We retrospectively analyzed 44 patients (45 lesions) with esophageal, gastric, duodenal, and colorectal neoplasms who had undergone ESD using the EndoTrac device between June 2018 and May 2019. Primary outcome measures were preparation time, procedural success using the EndoTrac device, and ease of ability to change towing direction. RESULTS: Mean preparation time was 2 (2-5) min in esophagus, 3 (1-5) min in stomach, 6 (5-9) min in duodenum, and 4 (2-8) min in colorectum. The procedural success rate was 100% (8/8) in esophagus, 100% (21/21) in stomach, 100% (4/4) in duodenum, and 100% (12/12) in colorectum. The rate of successful towing to both proximal and distal sides was 100% (8/8) in esophagus, 100% (21/21) in stomach, 0% (0/4) in duodenum, and 100% (12/12) in colorectum. CONCLUSIONS: Use of the EndoTrac device appears to be a feasible approach to ESD for GI neoplasms.


Asunto(s)
Neoplasias Colorrectales , Resección Endoscópica de la Mucosa , Neoplasias Colorrectales/cirugía , Resección Endoscópica de la Mucosa/efectos adversos , Humanos , Estudios Retrospectivos , Tracción , Resultado del Tratamiento
3.
Endoscopy ; 50(8): 813-817, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29883977

RESUMEN

BACKGROUND: Although endoscopic submucosal dissection has enabled complete tumor resection and accurate pathological assessment in a manner that is less invasive than surgery, the complete resection of lesions with severe fibrosis in the submucosal layer and exhibiting the muscle-retracting sign is often difficult. We have devised a new method, peranal endoscopic myectomy (PAEM), for rectal lesions with severe fibrosis, in which dissection is performed between the inner circular and outer longitudinal muscles, and have examined the usefulness and safety of this new technique. METHODS: All of the patients who underwent PAEM in our hospital and affiliated hospitals between July 2015 and June 2017 were retrospectively reviewed. RESULTS: 10 rectal lesions were treated with PAEM. En bloc resection with a negative vertical margin was achieved in eight patients (80 %), whose lesions were mucosal (n = 2), shallow submucosal (n = 1), deep submucosal (n = 4), and muscle invasive (n = 1). The clinical course of all patients after PAEM was favorable. In patients who underwent additional surgery, anus preservation was achieved on the basis of the pathological results from PAEM. CONCLUSIONS: PAEM for lesions with severe fibrosis exhibiting the muscle-retracting sign appears to be both safe and useful.


Asunto(s)
Disección/métodos , Músculo Liso/cirugía , Neoplasias del Recto/cirugía , Recto/patología , Cirugía Endoscópica Transanal/métodos , Disección/efectos adversos , Fibrosis , Humanos , Músculo Liso/patología , Invasividad Neoplásica , Neoplasias del Recto/patología , Estudios Retrospectivos , Cirugía Endoscópica Transanal/efectos adversos
5.
Intern Med ; 53(7): 699-701, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24694479

RESUMEN

The migration of Kirschner wires (K-wires) is a rare complication. We herein present a case of an inflammatory polyp in the colon caused by the migration of a K-wire following fixation of a pelvic fracture. Surgery was carried out to remove the K-wire through an incision at the level of the left iliac bone. Simultaneous endoscopic clipping of the colonic wound was also performed. The patient's postoperative course was uneventful. Although very rare, migration of devices should be considered in patients with a previous history of orthopedic surgery.


Asunto(s)
Hilos Ortopédicos/efectos adversos , Colon/lesiones , Pólipos del Colon/etiología , Migración de Cuerpo Extraño/complicaciones , Fijación Interna de Fracturas/efectos adversos , Fracturas Óseas/cirugía , Huesos Pélvicos/lesiones , Colon/cirugía , Pólipos del Colon/diagnóstico , Pólipos del Colon/cirugía , Colonoscopía , Remoción de Dispositivos/métodos , Migración de Cuerpo Extraño/diagnóstico , Fijación Interna de Fracturas/instrumentación , Fracturas Óseas/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Huesos Pélvicos/diagnóstico por imagen , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA