Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Cardiovasc Electrophysiol ; 34(4): 947-956, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36709469

RESUMEN

INTRODUCTION: Thoracic impedance (TI) drops measured by implantable cardioverter-defibrillators (ICDs) have been reported to correlate with ventricular tachycardia/fibrillation (VT/VF). The aim of our study was to assess the temporal association of decreasing TI trends with VT/VF episodes through a longitudinal analysis of daily remote monitoring data from ICDs and cardiac resynchronization therapy defibrillators (CRT-Ds). METHODS AND RESULTS: Retrospective data from 2384 patients were randomized 1:1 into a derivation or validation cohort. The TI decrease rate was defined as the percentage of rolling weeks with a continuously decreasing TI trend. The derivation cohort was used to determine a TI decrease rate threshold for a ≥99% specificity of arrhythmia prediction. The associated risk of VT/VF episodes was estimated in the validation cohort by dividing the available follow-up into 60-day assessment intervals. Analyses were performed separately for 1354 ICD and 1030 CRT-D patients. During a median follow-up of 2.0 years, 727 patients (30.4%) experienced 3298 confirmed VT/VF episodes. In the ICD group, a TI decrease rate of >60% was associated with a higher risk of VT/VF episode in a 60-day assessment interval (stratified hazard ratio, 1.42; 95% confidence interval (CI), 1.05-1.92; p = .023). The TI decrease preceded (40.8%) or followed (59.2%) the VT/VF episodes. In the CRT-D group, no association between TI decrease and VT/VF episodes was observed (p = .84). CONCLUSION: In our longitudinal analysis, TI decrease was associated with VT/VF episodes only in ICD patients. Preventive interventions may be difficult since episodes can occur before or after TI decrease.


Asunto(s)
Arritmias Cardíacas , Taquicardia Ventricular , Humanos , Arritmias Cardíacas/terapia , Impedancia Eléctrica , Estudios Retrospectivos , Fibrilación Ventricular , Desfibriladores Implantables
2.
JACC Clin Electrophysiol ; 8(12): 1553-1562, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36543505

RESUMEN

BACKGROUND: Causes of sex differences in incidence of sustained ventricular arrhythmias (SVAs) are poorly understood. OBJECTIVES: This study aims to investigate sex-specific risk of SVAs and device therapies by balancing sex groups in relation to several baseline characteristics with the propensity score (PS). METHODS: We used a large remote monitoring dataset from implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy defibrillators (CRT-Ds). Study endpoints were time to the first appropriate SVA, time to the first device therapy for SVA, and time to the first ICD shock. Results were compared between females and a PS-matched male subgroup. RESULTS: In a cohort of 2,532 patients with an ICD or CRT-D (median age, 70 years), 488 patients (19.3%) were women. After selecting 488 men PS-matched for 19 variables relative to baseline demographics, implant indications, principal comorbidities, and concomitant therapy, yet the SVA rate at the 2.1-year median follow-up was significantly lower in women than in man (adjusted HR: 0.65; 95% CI: 0.51-0.81; P < 0.001). Women also showed a reduced risk of any device therapy (HR: 0.59; 95% CI: 0.45-0.76; P < 0.001) and shocks (HR: 0.66; 95% CI: 0.47-0.94; P = 0.021). Differences in sex-specific SVA risk profile were not confirmed in CRT-D patients (HR: 0.78; 95% CI: 0.55-1.09; P = 0.14) nor in those with an ejection fraction <30% (HR: 0.80; 95% CI: 0.52-1.23; P = 0.31). CONCLUSIONS: After matching demographics, indications, principal comorbidities, and concomitant therapy, women still exhibited a lower SVA risk profile than men, except in the subgroups of CRT-D or/and ejection fraction <30%.


Asunto(s)
Desfibriladores Implantables , Humanos , Masculino , Femenino , Anciano , Desfibriladores Implantables/efectos adversos , Puntaje de Propensión , Resultado del Tratamiento , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/terapia , Cardioversión Eléctrica
3.
Circulation ; 145(25): 1829-1838, 2022 06 21.
Artículo en Inglés | MEDLINE | ID: mdl-35369700

RESUMEN

BACKGROUND: Optimal timing for catheter ablation of ventricular tachycardia is an important unresolved issue. There are no randomized trials evaluating the benefit of ablation after the first implantable cardioverter defibrillator (ICD) shock. METHODS: We conducted a 2-phase, prospective, multicenter, randomized clinical trial. Patients with ischemic or nonischemic dilated cardiomyopathy and primary or secondary prevention indication for ICD were enrolled in an initial observational phase until first appropriate shock (phase A). After reconsenting, patients were randomly assigned 1:1 in phase B to immediate ablation (within 2 months from shock delivery) or continuation of standard therapy. The primary end point was a composite of death from any cause or hospitalization for worsening heart failure. Amiodarone intake was not allowed except for documented atrial tachyarrhythmias. On July 23, 2021, phase B of the trial was interrupted as a result of the first interim analysis on the basis of the Bayesian adaptive design. RESULTS: Of the 517 patients enrolled in phase A, 154 (30%) had ventricular tachycardia, 56 (11%) received an appropriate shock over a median follow-up of 2.4 years (interquartile range, 1.4-4.4), and 47 of 56 (84%) agreed to participate in phase B. After 24.2 (8.5-24.4) months, the primary end point occurred in 1 of 23 (4%) patients in the ablation group and 10 of 24 (42%) patients in the control group (hazard ratio, 0.11 [95% CI, 0.01-0.85]; P=0.034). The results met the prespecified termination criterion of >99% Bayesian posterior probability of superiority of treatment over standard therapy. No deaths were observed in the ablation group versus 8 deaths (33%) in the control group (P=0.004); there was 1 worsening heart failure hospitalization in the ablation group (4%) versus 4 in the control group (17%; P=0.159). ICD shocks were less frequent in the ablation group (9%) than in the control group (42%; P=0.039). CONCLUSIONS: Ventricular tachycardia ablation after first appropriate shock was associated with a reduced risk of the combined death or worsening heart failure hospitalization end point, lower mortality, and fewer ICD shocks. These findings provide support for considering ventricular tachycardia ablation after the first ICD shock. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT01547208.


Asunto(s)
Ablación por Catéter , Desfibriladores Implantables , Insuficiencia Cardíaca , Taquicardia Ventricular , Teorema de Bayes , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Insuficiencia Cardíaca/terapia , Humanos , Pronóstico , Estudios Prospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Resultado del Tratamiento
4.
J Interv Card Electrophysiol ; 64(3): 607-619, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34709504

RESUMEN

PURPOSE: The purpose of this study was to assess the available mortality risk stratification models for implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy defibrillator (CRT-D) patients. METHODS: We conducted a review of mortality risk stratification models and tested their ability to improve prediction of 1-year survival after implant in a database of patients who received a remotely controlled ICD/CRT-D device during routine care and included in the independent Home Monitoring Expert Alliance registry. RESULTS: We identified ten predicting models published in peer-reviewed journals between 2000 and 2021 (Parkash, PACE, MADIT, aCCI, CHA2DS2-VASc quartiles, CIDS, FADES, Sjoblom, AAACC, and MADIT-ICD non-arrhythmic mortality score) that could be tested in our database as based on common demographic, clinical, echocardiographic, electrocardiographic, and laboratory variables. Our cohort included 1,911 patients with left ventricular dysfunction (median age 71, 18.3% female) from sites not using any risk stratification score for systematic patient screening. Patients received an ICD (53.8%) or CRT-D (46.2%) between 2011 and 2017, after standard physician evaluation. There were 56 deaths within 1-year post-implant, with an all-cause mortality rate of 2.9% (95% confidence interval [CI], 2.3-3.8%). Four predicting models (Parkash, MADIT, AAACC, and MADIT-ICD non-arrhythmic mortality score) were significantly associated with increased risk of 1-year mortality with hazard ratios ranging from 3.75 (CI, 1.31-10.7) to 6.53 (CI 1.52-28.0, p ≤ 0.014 for all four). Positive predictive values of 1-year mortality were below 25% for all models. CONCLUSION: In our analysis, the models we tested conferred modest incremental predicting power to ordinary screening methods.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Terapia de Resincronización Cardíaca/métodos , Dispositivos de Terapia de Resincronización Cardíaca/efectos adversos , Desfibriladores Implantables/efectos adversos , Femenino , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Medición de Riesgo , Factores de Riesgo , Resultado del Tratamiento
5.
Circ Arrhythm Electrophysiol ; 11(3): e005592, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29874166

RESUMEN

BACKGROUND: This multicenter, prospective study evaluated the determinants of zero-fluoroscopy (ZFL) ablation of supraventricular tachycardias. METHODS AND RESULTS: Four hundred thirty patients (215 male, 55.4±22.1 years) with indication to electrophysiological study or ablation of supraventricular tachycardias were enrolled. All participating physicians agreed to follow the as low as reasonably achievable policy. A procedure was defined as ZFL when no fluoroscopy was used. The total fluoroscopy time inversely correlated to the number of procedures previously performed by each operator since study start (r=-0.112; P=0.02). Two hundred eighty-nine procedures (67.2%) were ZFL; multivariable analysis identified as predictors of ZFL: procedure after the 30th for each operator, compared with procedures up to the ninth (P=0.011; hazard ratio, 3.49; 95% confidence interval [CI], 1.79-6.80); the type of arrhythmia (P=0.031; electrophysiological study and atrioventricular nodal reentry tachycardia ablation having the highest probability of ZFL; hazard ratio, 6.87; 95% CI, 2.08-22.7 and hazard ratio, 2.02; 95% CI, 1.04-3.91, respectively); the operator's (P=0.002) and patient's age (P=0.009). Among operators, achievement of ZFL varied from 0% to 100%; 8 (22.8%) operators achieved ZFL in <25% of their procedures; 17 (48.6%) operators achieved ZFL in >75% of their procedures. The probability of ZFL increased by 2.8% (hazard ratio, 0.98; 95% CI, 0.97-0.99) as patient's age decreased by 1 year. Acute procedural success was obtained in all cases. CONCLUSIONS: The use of 3-dimensional mapping system completely avoided the use of fluoroscopy in most cases, with very low fluoroscopy time in the remaining and high safety and effectiveness profiles. Achievement of ZFL was predicted by the type of arrhythmia, operator's experience, and patient's age.


Asunto(s)
Mapeo del Potencial de Superficie Corporal/métodos , Ablación por Catéter/métodos , Fluoroscopía/métodos , Cirugía Asistida por Computador/métodos , Taquicardia Supraventricular/cirugía , Femenino , Estudios de Seguimiento , Humanos , Imagenología Tridimensional , Italia , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Dosis de Radiación , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatología , Resultado del Tratamiento
6.
J Interv Card Electrophysiol ; 51(3): 245-252, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29502194

RESUMEN

PURPOSE: Latency during left ventricle (LV) pacing has been suggested as a potential cause of ineffectual biventricular pacing. We assessed the incidence, predictors, and impact on outcome of increased LV latency in 274 patients undergoing cardiac resynchronization therapy (CRT). METHODS: On implantation, the latency interval was defined as the shortest stimulus-to-QRS onset interval in any lead of the 12-lead ECG. A stimulus-to-QRS onset interval ≥ 40 ms was used to define the presence of increased LV latency. RESULTS: Increased LV latency was observed in 55 patients (20%). On multivariate analysis, only ischemic etiology proved to be a predictor of increased LV latency. On 12-month echocardiographic evaluation, 68% patients showed a ≥ 15% decrease in LV end systolic volume (74% patients with increased LV latency, 67% patients without increased LV latency (p = 0.58). The presence of increased LV latency was not associated with a different clinical response to CRT. CONCLUSIONS: Increased LV latency occurred in almost 20% of patients undergoing CRT and was more frequent in patients with ischemic heart disease. The presence of increased LV latency does not seem to have an impact on echocardiographic or clinical response to CRT.


Asunto(s)
Estimulación Cardíaca Artificial/métodos , Electrocardiografía , Insuficiencia Cardíaca/terapia , Isquemia Miocárdica/terapia , Anciano , Análisis de Varianza , Estimulación Cardíaca Artificial/mortalidad , Terapia de Resincronización Cardíaca/métodos , Terapia de Resincronización Cardíaca/mortalidad , Estudios de Cohortes , Ecocardiografía , Femenino , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/mortalidad , Pronóstico , Estudios Prospectivos , Sistema de Registros , Medición de Riesgo , Índice de Severidad de la Enfermedad , Tasa de Supervivencia , Resultado del Tratamiento , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/terapia
7.
JACC Clin Electrophysiol ; 3(5): 482-490, 2017 05.
Artículo en Inglés | MEDLINE | ID: mdl-29759604

RESUMEN

OBJECTIVES: This study sought to compare the Intrinsic Rhythm Support (IRSplus) and Ventricular Pace Suppress (VpS) in terms of right ventricular pacing percentage (VP %), mean atrioventricular interval (MAVI), atrial fibrillation, and cardiac volumes. BACKGROUND: Modern pacemakers are provided with algorithms for reducing unnecessary ventricular pacing. These may be classified as: periodic search for intrinsic atrioventricular (AV) conduction prolonging the AV delay accordingly; or DDD-ADI mode switch. The IRSplus and VpS algorithms belong to the former and latter classes, respectively. METHODS: Patients with sick sinus dysfunction without evidence of II/III degree AV block were 1:1 randomized to 6-month periods of either IRSplus or VpS, and then crossed over. Subsequent follow-ups were at the 12th month after randomization for device data retrieving, and at the 18th month with the same device programming for echocardiographic assessment. RESULTS: A total of 230 patients (62% males, median age 75 years [interquartile range: 69 to 79 years]) were enrolled. At a linear mixed-model analysis with order of treatment and investigational sites as nested random effects, differences in VP% and MAVI reached statistical significance: VP% was 1% (0% to 11%) during IRSplus and 3% (0% to 26%) during VpS (p = 0.029); MAVI was 225 ms (198 to 253 ms) during IRSplus and 214 ms (188 to 240 ms) during VpS (p = 0.014). No differences were observed in atrial fibrillation burden and incidence, ejection fraction, and cardiac volumes. CONCLUSIONS: Both IRSplus and VpS algorithms ensured VP% ≤3% in most patients with sinus node dysfunction and preserved AV conduction. The IRSplus was slightly more efficient in reducing VP% at the expense of a small MAVI increase, with statistical but clinically insignificant differences. (Ventricular Pace Suppression Versus Intrinsic Rhythm Support Study; NCT01528657).


Asunto(s)
Fibrilación Atrial/terapia , Estimulación Cardíaca Artificial/estadística & datos numéricos , Síndrome del Seno Enfermo/terapia , Procedimientos Innecesarios/estadística & datos numéricos , Anciano , Algoritmos , Dispositivos de Terapia de Resincronización Cardíaca , Volumen Cardíaco/fisiología , Estudios Cruzados , Femenino , Humanos , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...