Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
2.
Eur Radiol ; 24(8): 1950-8, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24865699

RESUMEN

OBJECTIVES: To assess the image quality of T2-weighted (T2w) magnetic resonance imaging of the prostate and the visibility of prostate cancer at 7 Tesla (T). MATERIALS & METHODS: Seventeen prostate cancer patients underwent T2w imaging at 7T with only an external transmit/receive array coil. Three radiologists independently scored images for image quality, visibility of anatomical structures, and presence of artefacts. Krippendorff's alpha and weighted kappa statistics were used to assess inter-observer agreement. Visibility of prostate cancer lesions was assessed by directly linking the T2w images to the confirmed location of prostate cancer on histopathology. RESULTS: T2w imaging at 7T was achievable with 'satisfactory' (3/5) to 'good' (4/5) quality. Visibility of anatomical structures was predominantly scored as 'satisfactory' (3/5) and 'good' (4/5). If artefacts were present, they were mostly motion artefacts and, to a lesser extent, aliasing artefacts and noise. Krippendorff's analysis revealed an α = 0.44 between three readers for the overall image quality scores. Clinically significant cancer lesions in both peripheral zone and transition zone were visible at 7T. CONCLUSION: T2w imaging with satisfactory to good quality can be routinely acquired, and cancer lesions were visible in patients with prostate cancer at 7T using only an external transmit/receive body array coil. KEY POINTS: • Satisfactory to good T2-weighted image quality of the prostate is achievable at 7T. • Periprostatic lipids appear hypo-intense compared to healthy peripheral zone tissue at 7T. • Prostate cancer is visible on T2-weighted MRI at 7T.


Asunto(s)
Artefactos , Aumento de la Imagen , Imagen por Resonancia Magnética/métodos , Estadificación de Neoplasias/métodos , Próstata/patología , Neoplasias de la Próstata/diagnóstico , Anciano , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
3.
Skeletal Radiol ; 43(5): 623-32, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24496584

RESUMEN

OBJECTIVES: To compare ultra-high field, high-resolution bilateral magnetic resonance imaging (MRI) of the hips at 7 Tesla (T) with 3 T MRI in patients with avascular necrosis (AVN) of the femoral head by subjective image evaluations, contrast measurements, and evaluation of the appearance of imaging abnormalities. MATERIALS AND METHODS: Thirteen subjects with avascular necrosis treated using advanced core decompression underwent MRI at both 7 T and 3 T. Sequence parameters as well as resolution were kept identical for both field strengths. All MR images (MEDIC, DESS, PD/T2w TSE, T1w TSE, and STIR) were evaluated by two radiologists with regard to subjective image quality, soft tissue contrasts, B1 homogeneity (four-point scale, higher values indicating better image quality) and depiction of imaging abnormalities of the femoral heads (three-point scale, higher values indicating the superiority of 7 T). Contrast ratios of soft tissues were calculated and compared with subjective data. RESULTS: 7-T imaging of the femoral joints, as well as 3-T imaging, achieved "good" to "very good" quality in all sequences. 7 T showed significantly higher soft tissue contrasts for T2w and MEDIC compared with 3 T (cartilage/fluid: 2.9 vs 2.2 and 3.6 vs 2.6), better detailed resolution for cartilage defects (PDw, T2w, T1w, MEDIC, DESS > 2.5) and better visibility of joint effusions (MEDIC 2.6; PDw/T2w 2.4; DESS 2.2). Image homogeneity compared with 3 T (3.9-4.0 for all sequences) was degraded, especially in TSE sequences at 7 T through signal variations (7 T: 2.1-2.9); to a lesser extent also GRE sequences (7 T: 2.9-3.5). Imaging findings related to untreated or treated AVN were better delineated at 3 T (≤1.8), while joint effusions (2.2-2.6) and cartilage defects (2.5-3.0) were better visualized at 7 T. STIR performed much more poorly at 7 T, generating large contrast variations (1.5). CONCLUSIONS: 7-T hip MRI showed comparable results in hip joint imaging compared with 3 T with slight advantages in contrast detail (cartilage defects) and fluid detection at 7 T when accepting image degradation medially.


Asunto(s)
Necrosis de la Cabeza Femoral/patología , Articulación de la Cadera/patología , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
4.
Skeletal Radiol ; 42(11): 1555-63, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23955579

RESUMEN

OBJECTIVE: To evaluate 7-T MRI of both hips using a multi-channel transmit technology to compensate for inherent B1 inhomogeneities in volunteers and patients with avascular necrosis of the femoral head. MATERIALS AND METHODS: A self-built, eight-channel transmit-receive coil was utilized for B1 modification at 7 T. Two shim modes (individual shim vs. CP2+ mode) were initially compared and the best shim result was used for all further imaging. Robustness of sequences against B1 inhomogeneities, appearance of anatomic and pathologic changes of the femoral heads of MEDIC, DESS, PD/T2w TSE, T1w TSE, and STIR sequences at 7 T were evaluated in 12 subjects on a four-point scale (1-4): four male volunteers and eight patients (seven males, one female) suffering from avascular necrosis treated by advanced core decompression. RESULTS: Successful MRI of both femoral heads was achieved in all 12 subjects. CP2+ mode proved superior in ten of 12 cases. DESS proved most robust against B1 inhomogeneity. Anatomical details (labrum, articular cartilage) were best depicted in PDw, MEDIC, and DESS, while for depiction of pathological changes PDw, DESS (0.76 mm(3)) and T1w were superior. CONCLUSIONS: Our initial results of ultra-high-field hip joint imaging demonstrate high-resolution, high-contrast images with a good depiction of anatomic and pathologic changes. However, shifting areas of signal dropout from the femoral heads to the center of the pelvis makes these areas not assessable. For clinical workflow CP2+ mode is most practical. Seven-Tesla MRI of the hip joints may become a valuable complement to clinical field strengths.


Asunto(s)
Necrosis de la Cabeza Femoral/patología , Cabeza Femoral/patología , Articulación de la Cadera/patología , Aumento de la Imagen/instrumentación , Interpretación de Imagen Asistida por Computador/instrumentación , Imagen por Resonancia Magnética/instrumentación , Adulto , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
5.
Eur Radiol ; 23(4): 1059-66, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23064714

RESUMEN

OBJECTIVE: The aim of this study was to assess the feasibility of first-pass contrast-enhanced renal MR angiography (MRA) at 7 T. METHODS: In vivo first-pass contrast-enhanced high-field examinations were obtained in eight healthy subjects on a 7-T whole-body MRI. A custom-built body transmit/receive radiofrequency (RF) coil and RF system suitable for RF shimming were used for image acquisition. For dynamic imaging, gadobutrol was injected intravenously and coronal unenhanced, arterial and venous data sets using a T1-weighted spoiled gradient-echo sequence were obtained. Qualitative image analysis and assessment of artefact impairment were performed by two senior radiologists using a five-point scale (5 = excellent, 1 = non-diagnostic). SNR and CNR of the perirenal abdominal aorta and both main renal arteries were assessed. RESULTS: Qualitative image evaluation revealed overall high-quality delineation of all assessed segments of the unenhanced arterial vasculature (meanunenhanced 4.13). Nevertheless, the application of contrast agent revealed an improvement in vessel delineation of all the vessel segments assessed, confirmed by qualitative (meanunenhanced 4.13 to meancontrast-enhanced 4.85) and quantitative analysis (SNR meanunenhanced 64.3 to meancontrast-enhanced 98.4). CONCLUSION: This study demonstrates the feasibility and current constraints of ultra-high-field contrast-enhanced renal MRA relative to unenhanced MRA.


Asunto(s)
Algoritmos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Compuestos Organometálicos , Arteria Renal/anatomía & histología , Adulto , Medios de Contraste , Femenino , Humanos , Masculino , Proyectos Piloto , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
6.
Clin Neuroradiol ; 23(1): 17-23, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23015059

RESUMEN

PURPOSE: The aim of this study was to demonstrate the feasibility of cranial nerve (CN II-XII) imaging with 7 Tesla magnetic resonance imaging (MRI). METHODS: In this study four sequences were evaluated in three healthy volunteers using magnetization preparation rapid gradient echo (MPRAGE), constructive interference in steady state (CISS), true fast imaging with steady state precession (TrueFISP) and proton density (PD) T2-weighted turbo spin echo (TSE) sequences. RESULTS: It was found that MPRAGE did not always provide sufficient contrast to delineate in particular small CNs but displayed an overall good identification rate. The T2 sequence was not able to adequately differentiate the small CNs but showed a very good contrast between nerves and cerebrospinal fluid (CSF). As at lower magnetic fields steady state sequences displayed a high identification rate of all CNs in the axial plane but CISS suffered from susceptibility and pulsation artifacts, furthermore it was limited as no parallel imaging could be performed. The TrueFISP technique was reliable in identifying most CNs although suffering from banding artifacts. CONCLUSIONS: The TrueFISP sequence showed superior spatial resolution and contrast in comparison to the other sequences for imaging of CNs at 7 T.


Asunto(s)
Algoritmos , Nervios Craneales/anatomía & histología , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Neuroimagen/métodos , Adulto , Estudios de Factibilidad , Humanos , Aumento de la Imagen/métodos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
7.
Magn Reson Med ; 67(4): 1033-41, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21858867

RESUMEN

As the magnetic field strength and therefore the operational frequency in MRI are increased, the radiofrequency wavelength approaches the size of the human head/body, resulting in wave effects which cause signal decreases and dropouts. Especially, whole-body imaging at 7 T and higher is therefore challenging. Recently, an acquisition scheme called time-interleaved acquisition of modes has been proposed to tackle the inhomogeneity problems in high-field MRI. The basic premise is to excite two (or more) different B 1+ modes using static radiofrequency shimming in an interleaved acquisition, where the complementary radiofrequency patterns of the two modes can be exploited to improve overall signal homogeneity. In this work, the impact of time-interleaved acquisition of mode on image contrast as well as on time-averaged specific absorption rate is addressed in detail. Time-interleaved acquisition of mode is superior in B 1+ homogeneity compared with conventional radiofrequency shimming while being highly specific absorption rate efficient. Time-interleaved acquisition of modes can enable almost homogeneous high-field imaging throughout the entire field of view in PD, T(2) , and T(2) *-weighted imaging and, if a specified homogeneity criterion is met, in T(1) -weighted imaging as well.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Algoritmos , Artefactos , Humanos , Aumento de la Imagen/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Análisis de los Mínimos Cuadrados , Masculino , Modelos Anatómicos , Fantasmas de Imagen , Ondas de Radio , Sensibilidad y Especificidad , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...