Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Rev Sci Instrum ; 95(1)2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38170817

RESUMEN

Supercritical fluids (SCFs) can be found in a variety of environmental and industrial processes. They exhibit an anomalous thermodynamic behavior, which originates from their fluctuating heterogeneous micro-structure. Characterizing the dynamics of these fluids at high temperature and high pressure with nanometer spatial and picosecond temporal resolution has been very challenging. The advent of hard x-ray free electron lasers has enabled the development of novel multi-pulse ultrafast x-ray scattering techniques, such as x-ray photon correlation spectroscopy (XPCS) and x-ray pump x-ray probe (XPXP). These techniques offer new opportunities for resolving the ultrafast microscopic behavior in SCFs at unprecedented spatiotemporal resolution, unraveling the dynamics of their micro-structure. However, harnessing these capabilities requires a bespoke high-pressure and high-temperature sample system that is optimized to maximize signal intensity and address instrument-specific challenges, such as drift in beamline components, x-ray scattering background, and multi-x-ray-beam overlap. We present a pressure cell compatible with a wide range of SCFs with built-in optical access for XPCS and XPXP and discuss critical aspects of the pressure cell design, with a particular focus on the design optimization for XPCS.

2.
Rev Sci Instrum ; 95(1)2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38175942

RESUMEN

A channel-cut crystal monochromator (CCM) is a popular and powerful device for producing monochromatic x-ray beams with extreme angular stability at a nano-radian level. Narrowing the groove width of CCMs has various benefits; for example, it is made possible to design more compact CCMs with an equivalent working energy range and to reduce the optical delay and the amount of beam shift, enhancing compatibility with various experimental techniques. An obstacle to the use of narrow-groove CCMs is the lack of a high-precision finishing method for the inner-wall reflecting surfaces, which imposes the distortion of x-ray wavefronts and spectral purity. We propose a new, damage-free surface-finishing method for silicon CCMs with a narrow groove of 1 mm or less with a localized etching technique using plasma generated with a wire electrode of 50 µm diameter under atmospheric pressure. Repeating plasma-on and plasma-off periods with a pulsed power supply, we reduce the concentration of reaction products through self-diffusion during the plasma-off periods and minimize the redeposition of the products on the processed surface that deteriorates the surface roughness. Under optimized conditions, we processed a CCM with a groove width of 1.2 mm, which has uniform reflection profiles and a nearly ideal reflectivity behavior for coherent monochromatic x rays.

3.
Phys Rev Lett ; 131(16): 163201, 2023 Oct 20.
Artículo en Inglés | MEDLINE | ID: mdl-37925726

RESUMEN

X-ray diffraction of silicon irradiated with tightly focused femtosecond x-ray pulses (photon energy, 11.5 keV; pulse duration, 6 fs) was measured at various x-ray intensities up to 4.6×10^{19} W/cm^{2}. The measurement reveals that the diffraction intensity is highly suppressed when the x-ray intensity reaches of the order of 10^{19} W/cm^{2}. With a dedicated simulation, we confirm that the observed reduction of the diffraction intensity can be attributed to the femtosecond change in individual atomic scattering factors due to the ultrafast creation of highly ionized atoms through photoionization, Auger decay, and subsequent collisional ionization. We anticipate that this ultrafast reduction of atomic scattering factor will be a basis for new x-ray nonlinear techniques, such as pulse shortening and contrast variation x-ray scattering.

4.
Phys Rev Lett ; 131(7): 076901, 2023 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-37656841

RESUMEN

We report ultrafast x-ray scattering experiments of the quasi-1D charge density wave (CDW) material (TaSe_{4})_{2}I following ultrafast infrared photoexcitation. From the time-dependent diffraction signal at the CDW sidebands we identify a 0.11 THz amplitude mode derived primarily from a transverse acoustic mode of the high-symmetry structure. From our measurements we determine that this mode interacts with the valence charge indirectly through another collective mode, and that the CDW system in (TaSe_{4})_{2}I has a composite nature supporting multiple dynamically active structural degrees of freedom.

5.
J Synchrotron Radiat ; 30(Pt 5): 1013-1022, 2023 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-37610343

RESUMEN

The BL09XU beamline of SPring-8 has been reorganized into a beamline dedicated for hard X-ray photoelectron spectroscopy (HAXPES) to provide advanced capabilities with upgraded optical instruments. The beamline has two HAXPES analyzers to cover a wide range of applications. Two sets of double channel-cut crystal monochromators with the Si(220) and (311) reflections were installed to perform resonant HAXPES analyses with a total energy resolution of less than 300 meV over a wide energy range (4.9-12 keV) while achieving a fixed-exit condition. A double-crystal X-ray phase retarder using diamond crystals controls the polarization state with a high degree of polarization over 0.9 in the wide energy range 5.9-9.5 keV. Each HAXPES analyzer is equipped with a focusing mirror to provide a high-flux microbeam. The design and performance of the upgraded instruments are presented.

7.
Nat Commun ; 14(1): 4262, 2023 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-37460582

RESUMEN

High sensitivity of the Kß fluorescence spectrum to electronic state is widely used to investigate spin and oxidation state of first-row transition-metal compounds. However, the complex electronic structure results in overlapping spectral features, and the interpretation may be hampered by ambiguity in resolving the spectrum into components representing different electronic states. Here, we tackle this difficulty with a nonlinear resonant inelastic X-ray scattering (RIXS) scheme, where we leverage sequential two-photon absorption to realize an inverse process of the Kß emission, and measure the successive Kα emission. The nonlinear RIXS reveals two-dimensional (2D) Kß-Kα fluorescence spectrum of copper metal, leading to better understanding of the spectral feature. We isolate 3d-related satellite peaks in the 2D spectrum, and find good agreement with our multiplet ligand field calculation. Our work not only advances the fluorescence spectroscopy, but opens the door to extend RIXS into the nonlinear regime.

8.
Optica ; 10(4): 513-519, 2023 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-38239819

RESUMEN

X-ray free-electron lasers (XFELs) provide intense pulses that can generate stimulated X-ray emission, a phenomenon that has been observed and studied in materials ranging from neon to copper. Two schemes have been employed: amplified spontaneous emission (ASE) and seeded stimulated emission (SSE), where a second color XFEL pulse provides the seed. Both phenomena are currently explored for coherent X-ray laser sources and spectroscopy. Here, we report measurements of ASE and SSE of the 5.9 keV Mn Kα1 fluorescence line from a 3.9 molar NaMnO4 solution, pumped with 7 femtosecond FWHM XFEL pulses at 6.6 keV. We observed ASE at a pump pulse intensity of 1.7 × 1019 W/cm2, consistent with earlier findings. We observed SSE at dramatically reduced pump pulse intensities down to 1.1 × 1017 W/cm2. These intensities are well within the range of many existing XFEL instruments, which supports the experimental feasibility of SSE as a tool to generate coherent X-ray pulses, spectroscopic studies of transition metal complexes, and other applications.

9.
J Synchrotron Radiat ; 29(Pt 5): 1265-1272, 2022 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-36073886

RESUMEN

In this study, double-multilayer monochromators that generate intense, high-energy, pink X-ray beams are designed, installed and evaluated at the SPring-8 medium-length (215 m) bending-magnet beamline BL20B2 for imaging applications. Two pairs of W/B4C multilayer mirrors are designed to utilize photon energies of 110 keV and 40 keV with bandwidths of 0.8% and 4.8%, respectively, which are more than 100 times larger when compared with the Si double-crystal monochromator (DCM) with a bandwidth of less than 0.01%. At an experimental hutch located 210 m away from the source, a large and uniform beam of size 14 mm (V) × 300 mm (H) [21 mm (V) × 300 mm (H)] was generated with a high flux density of 1.6 × 109 photons s-1 mm-2 (6.9 × 1010 photons s-1 mm-2) at 110 keV (40 keV), which marked a 300 (190) times increase in the photon flux when compared with a DCM with Si 511 (111) diffraction. The intense pink beams facilitate advanced X-ray imaging for large-sized objects such as fossils, rocks, organs and electronic devices with high speed and high spatial resolution.


Asunto(s)
Fotones , Sincrotrones , Rayos X
10.
Nat Commun ; 13(1): 2292, 2022 Apr 28.
Artículo en Inglés | MEDLINE | ID: mdl-35484122

RESUMEN

Bimodal behavior in the translational order of silicon's second shell in SiO2 liquid at high temperatures and high pressures has been recognized in theoretical studies, and the fraction of the S state with high tetrahedrality is considered as structural origin of the anomalous properties. However, it has not been well identified in experiment. Here we show experimental evidence of a bimodal behavior in the translational order of silicon's second shell in SiO2 glass under pressure. SiO2 glass shows tetrahedral symmetry structure with separation between the first and second shells of silicon at low pressures, which corresponds to the S state structure reported in SiO2 liquid. On the other hand, at high pressures, the silicon's second shell collapses onto the first shell, and more silicon atoms locate in the first shell. These observations indicate breaking of local tetrahedral symmetry in SiO2 glass under pressure, as well as SiO2 liquid.

11.
Proc Natl Acad Sci U S A ; 119(12): e2119616119, 2022 03 22.
Artículo en Inglés | MEDLINE | ID: mdl-35290124

RESUMEN

Coherent nonlinear spectroscopies and imaging in the X-ray domain provide direct insight into the coupled motions of electrons and nuclei with resolution on the electronic length scale and timescale. The experimental realization of such techniques will strongly benefit from access to intense, coherent pairs of femtosecond X-ray pulses. We have observed phase-stable X-ray pulse pairs containing more than 3 × 107 photons at 5.9 keV (2.1 Å) with ∼1 fs duration and 2 to 5 fs separation. The highly directional pulse pairs are manifested by interference fringes in the superfluorescent and seeded stimulated manganese Kα emission induced by an X-ray free-electron laser. The fringes constitute the time-frequency X-ray analog of Young's double-slit interference, allowing for frequency domain X-ray measurements with attosecond time resolution.

12.
Phys Rev Lett ; 127(16): 163903, 2021 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-34723578

RESUMEN

To shorten the duration of x-ray pulses, we present a nonlinear optical technique using atoms with core-hole vacancies (core-hole atoms) generated by inner-shell photoionization. The weak Coulomb screening in the core-hole atoms results in decreased absorption at photon energies immediately above the absorption edge. By employing this phenomenon, referred to as saturable absorption, we successfully reduce the duration of x-ray free-electron laser pulses (photon energy: 9.000 keV, duration: 6-7 fs, fluence: 2.0-3.5×10^{5} J/cm^{2}) by ∼35%. This finding that core-hole atoms are applicable to nonlinear x-ray optics is an essential stepping stone for extending nonlinear technologies commonplace at optical wavelengths to the hard x-ray region.

13.
IUCrJ ; 8(Pt 5): 713-718, 2021 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-34584733

RESUMEN

X-ray scientists are continually striving to improve the quality of X-ray microscopy, due to the fact that the information obtained from X-ray microscopy of materials can be complementary to that obtained from optical and electron microscopes. In contrast to the ease with which one can deflect electron beams, the relative difficulty to deflect X-ray has constrained the development of scanning X-ray microscopes (SXMs) based on a scan of an X-ray small probe. This restriction has caused severe complications that hinder progress toward achieving ultimate resolution. Here, a simple and innovative method for constructing an SXM equipped with a nanoprobe scanner is proposed. The nanoprobe scanner combines X-ray prisms and advanced Kirkpatrick-Baez focusing mirrors. By rotating the prisms on the order of degrees, X-ray probe scanning with single-nanometre accuracy can be easily achieved. The validity of the concept was verified by acquiring an SXM image of a test pattern at a photon energy of 10 keV, where 50 nm line-and-space structures were resolved. This method is readily applicable to an SXM with a single-nanometre resolution and will assist effective utilization of increasing brightness of fourth-generation synchrotron radiation sources.

14.
Phys Rev Lett ; 126(11): 117403, 2021 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-33798368

RESUMEN

Ultrafast changes of charge density distribution in diamond after irradiation with an intense x-ray pulse (photon energy, 7.8 keV; pulse duration, 6 fs; intensity, 3×10^{19} W/cm^{2}) have been visualized with the x-ray pump-x-ray probe technique. The measurement reveals that covalent bonds in diamond are broken and the electron distribution around each atom becomes almost isotropic within ∼5 fs after the intensity maximum of the x-ray pump pulse. The 15 fs time delay observed between the bond breaking and atomic disordering indicates nonisothermality of electron and lattice subsystems on this timescale. From these observations and simulation results, we interpret that the x-ray-induced change of the interatomic potential drives the ultrafast atomic disordering underway to the following nonthermal melting.

15.
J Synchrotron Radiat ; 28(Pt 1): 372, 2021 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-33399589

RESUMEN

Corrections to equations and experimental results in the paper by Inoue et al. [(2019). J. Synchrotron Rad. 26, 2050-2054] are made.

16.
Nat Commun ; 11(1): 6213, 2020 Dec 04.
Artículo en Inglés | MEDLINE | ID: mdl-33277499

RESUMEN

With their brilliance and temporal structure, X-ray free-electron laser can unveil atomic-scale details of ultrafast phenomena. Recent progress in split-and-delay optics (SDO), which produces two X-ray pulses with time-delays, offers bright prospects for observing dynamics at the atomic-scale. However, their insufficient pulse energy has limited its application either to phenomena with longer correlation length or to measurement with a fixed delay-time. Here we show that the combination of the SDO and self-seeding of X-rays increases the pulse energy and makes it possible to observe the atomic-scale dynamics in a timescale of picoseconds. We show that the speckle contrast in scattering from water depends on the delay-time as expected. Our results demonstrate the capability of measurement using the SDO with seeded X-rays for resolving the dynamics in temporal and spatial scales that are not accessible by other techniques, opening opportunities for studying the atomic-level dynamics.

17.
J Synchrotron Radiat ; 27(Pt 6): 1720-1724, 2020 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-33147199

RESUMEN

A simple scheme is proposed and experimentally confirmed to generate X-ray free-electron lasers (XFELs) consisting of broadband and narrowband beams with a controllable intensity ratio and a large photon-energy separation. This unique two-color XFEL beam will open new opportunities for investigation of nonlinear interactions between intense X-rays and matter.

18.
Opt Express ; 28(18): 25706-25715, 2020 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-32906855

RESUMEN

A high-resolution micro channel-cut crystal monochromator (µCCM) composed of an Si(220) crystal is developed for the purpose of narrowing the bandwidth of a reflection self-seeded X-ray free-electron laser. Subsurface damage on the monochromator, which distorts the wavefront and broadens the bandwidth of the monochromatic seed beam, was removed by using a plasma etching technique. High diffraction performance of the monochromator was confirmed through evaluation with coherent X-rays. Reflection self-seeding operation was tested with the Si(220) µCCM at SPring-8 Angstrom Compact free-electron laser. A narrow average bandwidth of 0.6 eV, which is five times narrower than the value previously reported [I. Inoue et al., Nat. Photonics13, 319 (2019)10.1038/s41566-019-0365-y], was successfully obtained at 9 keV. The narrow-band X-ray beams with high intensity realized in this study will further expand the capabilities of X-ray free-electron lasers.

19.
J Synchrotron Radiat ; 27(Pt 5): 1358-1361, 2020 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-32876611

RESUMEN

Aiming for the fine observation of fast physical phenomena such as phonon propagation and laser ablation, phase-contrast X-ray imaging combined with a crystal X-ray interferometer and the X-ray free-electron laser (XFEL) of the SPring-8 Angstrom Compact Free-Electron Laser has been developed. An interference pattern with 70% visibility was obtained by single-shot exposure with a 15 keV monochromated XFEL. In addition, a phase map of an acrylic wedge was successfully obtained using the fringe scanning method.

20.
J Synchrotron Radiat ; 27(Pt 5): 1366-1371, 2020 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-32876613

RESUMEN

This paper proposes and demonstrates a simple method using the intensity correlation of X-ray fluorescence to evaluate the focused beam size of an X-ray free-electron laser (XFEL). This method was applied to the sub-micrometre focused XFEL beam at the SPring-8 Angstrom Compact Free Electron Laser, and the beam size evaluated using the proposed method was consistent with that measured using the knife-edge scan method. The proposed method is readily applicable to extremely small X-ray spots and can be applied for the precise diagnostics of sub-10 nm focused X-ray beams which have recently emerged.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...