1.
J Infect Chemother ; 29(6): 624-627, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36914095

RESUMEN

The humoral response to SARS-CoV-2 vaccination has shown to be temporary, although may be more prolonged in vaccinated individuals with a history of natural infection. We aimed to study the residual humoral response and the correlation between anti-Receptor Binding Domain (RBD) IgG levels and antibody neutralizing capacity in a population of health care workers (HCWs) after 9 months from COVID-19 vaccination. In this cross-sectional study, plasma samples were screened for anti-RBD IgG using a quantitative method. The neutralizing capacity for each sample was estimated by means of a surrogate virus neutralizing test (sVNT) and results expressed as the percentage of inhibition (%IH) of the interaction between RBD and the angiotensin-converting enzyme. Samples of 274 HCWs (227 SARS-CoV-2 naïve and 47 SARS-CoV-2 experienced) were tested. The median level of anti-RBD IgG was significantly higher in SARS-CoV-2 experienced than in naïve HCWs: 2673.2 AU/mL versus 610.9 AU/mL, respectively (p <0.001). Samples of SARS-CoV-2 experienced subjects also showed higher neutralizing capacity as compared to naïve subjects: median %IH = 81.20% versus 38.55%, respectively; p <0.001. A quantitative correlation between anti-RBD Ab and inhibition activity levels was observed (Spearman's rho = 0.89, p <0.001): the optimal cut-off correlating with high neutralization was estimated to be 1236.1 AU/mL (sensitivity 96.8%, specificity 91.9%; AUC 0.979). Anti-SARS-CoV-2 hybrid immunity elicited by a combination of vaccination and infection confers higher anti-RBD IgG levels and higher neutralizing capacity than vaccination alone, likely providing better protection against COVID-19.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/prevención & control , Inmunidad Humoral , Vacuna BNT162 , Vacunas contra la COVID-19 , Estudios Transversales , Pruebas de Neutralización , Anticuerpos Neutralizantes , Inmunoglobulina G , Anticuerpos Antivirales , Vacunación
2.
Front Immunol ; 13: 947187, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36248864

RESUMEN

This study monitored the anti-spike-receptor-binding domain (RBD) and neutralizing antibodies induced by the Pfizer/BioNTech mRNA BNT162b2 vaccine in a cohort of 163 healthcare workers aged ≤60 years. We have taken advantage of two study groups, both of whom received the first two doses in the same time window, but Group 1 (54 HCWs) received the third dose 2 months before Group 2 (68 HCWs) did. The cohorts were monitored from the 12th day after the first vaccine dose up to 1 month after the third vaccine dose for a total of eight time points and about 1 year of surveillance (T1 = 12 days after the first dose; T2 = 10 days after the second dose; T3 = 1 month after the second dose; T4 = 3 months after the second dose; T5 = 4 months after the second dose; T6 = 5 months after the second dose; T7 = 7 months after the second dose; T8 = 1 month after the third dose for Group 1; T8* = 9 months after the second dose for Group 2; T9 = 1 month after the third dose for Group 2). The mean value of anti-spike antibodies decreased faster over time, but at T7, its decline was significantly slowed (T7 vs. T8*). After the third dose, the anti-spike titer rose about 34-fold (T7 vs. T8 and T8* vs. T9) and the booster improved the anti-spike titer by about three times compared with that of the second dose (T3 vs. T8 and T3 vs. T9), and no difference was noted between the two groups. The neutralizing titer was evaluated at T3, T7, T8, and T9. Anti-spike and neutralizing antibodies were found to be strongly correlated (r2 = 0.980; p < 0.001). At T3, 70% of the participants had a neutralizing antibody titer >91% of total anti-spike antibodies that increased to 90% after the third dose (T8 and T9). However, when the anti-spike titer reached its lowest value (T7), the neutralizing antibody levels decreased even further, representing only 44% of total anti-spike antibodies (p < 0.0001). Our findings show that the third vaccine dose improves the humoral response, but the wane of the anti-spike and neutralizing antibody titers over time is more marked in the neutralizing antibodies.


Asunto(s)
Vacuna BNT162 , COVID-19 , Anticuerpos Neutralizantes , Anticuerpos Antivirales , Formación de Anticuerpos , COVID-19/prevención & control , Personal de Salud , Humanos , ARN Mensajero , SARS-CoV-2
3.
Int J Lab Hematol ; 43(5): 973-982, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33750012

RESUMEN

INTRODUCTION: Point of care testing (POCT) represents a valuable option when laboratory data shall be urgently available for timely clinical management, with a turnaround time (TAT) that is unfeasible using conventional laboratory instrumentation. This study was aimed to compare the performance of QBC STAR™ compared to Sysmex XN-module and the reference optical microscopy (OM) assessment. MATERIAL AND METHODS: One hundred peripheral blood samples, collected in K3 EDTA tubes, and 50 capillary blood samples obtained by finger stick were analyzed with QBC STAR™, Sysmex XN-module, and OM. Data were compared with Passing-Bablok regression and Bland-Altman plots. RESULTS: The Passing-Bablok regression analysis (QBC STAR™ capillary sample vs XN-module) yielded slopes comprised between 0.30 and 1.37, while the intercepts ranged between -17.57 and 232.6. Bland-Altman plots yielded relative bias comprised between -4.87% (for MN QBC STAR™ capillary sample vs XN-module) and 27% (PLT QBC STAR™ capillary sample vs XN-module). A significant bias was found for all parameters except MN and WBC, RBC in all and pediatric samples, and HB in adults samples. CONCLUSION: The results of this analytical evaluation suggest that QBC STAR™ may not be the ideal tool for performing complete blood count analysis for diagnostic purposes, while it could be more useful in urgent/emergent conditions, such as for rapid monitoring of some hematological parameters (eg, WBC and HB).


Asunto(s)
Recuento de Células Sanguíneas/métodos , Pruebas en el Punto de Atención , Adolescente , Adulto , Recuento de Células Sanguíneas/instrumentación , Niño , Preescolar , Femenino , Humanos , Lactante , Recién Nacido , Laboratorios , Masculino , Microscopía , Persona de Mediana Edad , Datos Preliminares , Análisis de Regresión
4.
PLoS One ; 16(2): e0246513, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33626045

RESUMEN

Castiglione D'Adda is one of the municipalities more precociously and severely affected by the Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) epidemic in Lombardy. With our study we aimed to understand the diffusion of the infection by mass serological screening. We searched for SARS-CoV-2 IgGs in the entire population on a voluntary basis using lateral flow immunochromatographic tests (RICT) on capillary blood (rapid tests). We then performed chemioluminescent serological assays (CLIA) and naso-pharyngeal swabs (NPS) in a randomized representative sample and in each subject with a positive rapid test. Factors associated with RICT IgG positivity were assessed by uni- and multivariate logistic regression models. Out of the 4143 participants, 918 (22·2%) showed RICT IgG positivity. In multivariable analysis, IgG positivity increases with age, with a significant non-linear effect (p = 0·0404). We found 22 positive NPSs out of the 1330 performed. Albeit relevant, the IgG prevalence is lower than expected and suggests that a large part of the population remains susceptible to the infection. The observed differences in prevalence might reflect a different infection susceptibility by age group. A limited persistence of active infections could be found after several weeks after the epidemic peak in the area.


Asunto(s)
Prueba Serológica para COVID-19/métodos , COVID-19/epidemiología , COVID-19/transmisión , Anticuerpos Antivirales/sangre , COVID-19/sangre , COVID-19/diagnóstico , Prueba Serológica para COVID-19/estadística & datos numéricos , Estudios Transversales , Femenino , Humanos , Inmunoglobulina G/sangre , Inmunoglobulina M/sangre , Italia/epidemiología , Masculino , Tamizaje Masivo/métodos , Prevalencia , SARS-CoV-2/genética , SARS-CoV-2/patogenicidad
5.
Hum Vaccin Immunother ; 17(12): 4747-4754, 2021 Dec 02.
Artículo en Inglés | MEDLINE | ID: mdl-35086438

RESUMEN

In Italy, SARS-CoV-2 vaccination campaign prioritized healthcare workers (HCWs) to receive two doses of BNT162b2 vaccine, irrespective of a previous SARS-CoV-2 infection. In this real-life study, we compared the humoral response to BNT162b2 vaccine in HCWs with and without a previous SARS-CoV-2 infection. Of the 407 HCWs enrolled, 334 (82.1%) were SARS-CoV-2-naive and 73 (17.9%) SARS-CoV-2-experienced. Post-vaccine humoral response was detectable in more than 98% of HCWs. Overall, the median level of anti-S IgG in SARS-COV-2-experienced HCWs was twice as high as those of SARS-CoV-2-naive subjects (24641.0 AU/mL [IQR: 15273.0->40000.0] versus 13053.8 [IQR: 7303.3-20105.8]; p < .001), irrespective of the time elapsed from SARS-CoV-2 previous infection. In a subgroup of SARS-CoV-2-naive and -experienced subjects who received only one dose of the vaccine, the latter showed 32 times higher levels of anti-S IgG compared to the former. Although no serious adverse events have been reported, mild to moderate side effects occurred more frequently after the first dose in the SARS-CoV-2-experienced than in naive subjects (67% versus 42%, respectively; p < .001). Notably, post-vaccination anti-SARS-CoV-2 spike IgG levels ≥20,000 AU/mL were independently associated with the risk of fever ≥38°C (adjusted odds ratio [aOR] 5.122, 95% CI 2.368-11.080, p < .0001).Our study showed high responsiveness of BNT162b2 vaccine and a relationship between levels of antibody response and reactogenicity. It suggests that a single dose of mRNA vaccine might evoke effective protection in SARS-CoV-2-experienced subjects.


Asunto(s)
Vacunas contra la COVID-19 , COVID-19 , Anticuerpos Antivirales , Formación de Anticuerpos , Vacuna BNT162 , COVID-19/prevención & control , Personal de Salud , Hospitales , Humanos , ARN Mensajero , Derivación y Consulta , SARS-CoV-2 , Vacunas Sintéticas , Vacunas de ARNm
8.
J Clin Pathol ; 72(7): 493-500, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31036703

RESUMEN

AIMS: Limited information is available on number and type of cells present in the pericardial fluid (PF). Current evidence and has been garnered with inaccurate application of guidelines for analysis of body fluids. This study was aimed at investigating the performance of automate cytometric analysis of PF in adult subjects. METHODS: Seventy-four consecutive PF samples were analysed with Sysmex XN with a module for body fluid analysis (XN-BF) and optical microscopy (OM). The study also encompassed the assessment of limit of blank, limit of detection and limit of quantitation (LoQ), imprecision, carryover and linearity of XN-BF module. RESULTS: XN-BF parameters were compared with OM for the following cell classes: total cells (TC), leucocytes (white blood cell [WBC]), polymorphonuclear (PMN) and mononuclear (MN) cells. The relative bias were -4.5%, 71.2%, 108.2% and -47.7%, respectively. Passing and Bablok regression yielded slope comprised between 0.06 for MN and 5.8 for PMN, and intercept between 0.7 for PMN and 220.3 for MN. LoQ was comprised between 3.8×106 and 6.0×106 cells/L for WBC and PMN. Linearity was acceptable and carryover negligible. CONCLUSIONS: PF has a specific cellular composition. Overall, automated cell counting can only be suggested for total number of cells, whereas OM seems still the most reliable option for cell differentiation.


Asunto(s)
Líquido Pericárdico/citología , Automatización de Laboratorios , Recuento de Células Sanguíneas , Procedimientos Quirúrgicos Cardíacos , Diferenciación Celular , Estudios de Cohortes , Femenino , Citometría de Flujo , Humanos , Masculino , Microscopía
9.
Int J Lab Hematol ; 41(2): 277-286, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30758900

RESUMEN

INTRODUCTION: Cellular analysis in body fluids (BFs) provides important diagnostic information in various pathological settings. This study was hence aimed at comparing automated cell count obtained with Mindray BC-6800 (BC-BF) vs Sysmex XN-series (XN-BF) and evaluating other quantitative and qualitative information provided by these analyzers in ascitic (AF), pleural (PF), synovial (SF), and cerebrospinal (CSF) fluids. METHODS: Three hundred and fifty-one samples (99 AFs, 45 PFs, 75 SFs, and 132 CSFs) were analyzed in parallel with BC-BF, XN-BF, and optical microscopy (OM). The study also included the assessment of diagnostic agreement among BC-BF, XN-BF, and OM. RESULTS: The comparison of BC-BF vs XN-BF yielded slopes of Passing and Bablok regression always comprised between 0.9 and 1.0 except for EO-BF and HF-BF, whilst the intercepts ranged from -0.4 for MN-BF and 12.0 for PMN-BF. The bias was comprised between -103.3% and 67.1% for HF-BF and EO-BF, respectively. A significant bias was found for TC-BF, WBC-BF, HF-BF (negative bias) and for PMN-BF and EO-BF (positive bias). The agreement (Cohen's kappa) between XN-BF and BC-BF was always ≥0.7, ranging between 0.87 in CSFs and 0.94 in AFs, and that with OM was similar (ie, 0.85 and 0.96). CONCLUSION: The cytometric analysis of BF samples using BC-BF and XN-BF is clinically favorable when appropriately combined with OM. Quantitative and qualitative parameters displayed optimal agreement, whilst instrument-specific cut-offs should be defined and implemented for HF-BF and EO-BF. Further efforts should be made for achieving better harmonization in cytometric analysis of BF samples.


Asunto(s)
Líquido Ascítico/citología , Líquido Cefalorraquídeo/citología , Citometría de Flujo , Líquido Sinovial/citología , Recuento de Células/instrumentación , Recuento de Células/métodos , Femenino , Citometría de Flujo/instrumentación , Citometría de Flujo/métodos , Humanos , Masculino
10.
G Ital Nefrol ; 35(6)2018 Dec.
Artículo en Italiano | MEDLINE | ID: mdl-30550034

RESUMEN

With these recommendations the Interdisciplinary Urinalysis Group (GIAU) aims to stimulate the following aspects : improvement and standardization of the post analytical approach to physical, chemical and morphological urine examination (ECMU); emphasize the value added to ECMU by selection of clinically significant parameters, indication of analytical methods, of units of measurement, of reference values; improvement of interpretation of dip stick urinalysis with particular regard to the reconsideration of the diagnostic significance of the evaluated parameters together with an increasing awareness of the limits of sensitivity and specificity of this analytical method. Accompanied by the skills to propose and carry out in-depth investigations with analytical methods that are more sensitive and specific;increase the awareness of the importance of professional skills in the field of urinary morphology and their relationships with the clinicians. through the introduction, in the report, of descriptive and interpretative comments depending on the type of request, the complexity of the laboratory, the competence of the pathologist;implement a policy of evaluation of the analytical quality by using, in addition to traditional internal and external controls, a program for the evaluation of morphological competence. The hope is to revalue the enormous potential diagnostic of ECMU, implementing a urinalysis on personalized diagnostic needs that each patient brings with it.


Asunto(s)
Urinálisis/normas , Control de Formularios y Registros , Humanos , Registros Médicos/normas , Control de Calidad , Reproducibilidad de los Resultados , Manejo de Especímenes , Urinálisis/métodos , Orina/química , Orina/citología
11.
J Med Biochem ; 37(4): 486-498, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30584409

RESUMEN

BACKGROUND: The cell population data (CPD) measured by Sysmex XN-9000 can be used for screening many hematological and non-hematological disorders. Since little information is available on harmonization of CPD among different instrumentation and clinical laboratories, this study aimed at assessing the current degree of CPD harmonization between separate Sysmex XN modules allocated to the same laboratory. METHODS: A total number of 78291 data were used for verification of within-run imprecision, analyzers harmonization, reference ranges and assessment of blood sample stability of CPD parameters, including results of daily quality control testing and those generated in samples collected from blood donors and healthy volunteers. RESULTS: Within-run imprecision of CPD parameters ranged between 0.4 and 14.1%. Good agreement was found among five different XN-modules, especially when values were adjusted after calculation of instrument-specific alignment factors. The bias of all parameters remained always lower than the reference change values in samples stored for up to 8 hours, regardless of storage temperature. CONCLUSIONS: The imprecision of CPD parameters was acceptable, except for those reflecting the dispersion of cellular clusters. Due to the lack of reference control materials, we showed that the use of data generated on a large number of normal routine samples (i.e., a Moving Average population) may be a reliable approach for testing analyzers harmonization. Nevertheless, availability of both calibration and quality control materials for these parameters is highly advisable in the future. We finally showed that whole blood samples may be stable for up to 2-4 hours for most CPD parameters.

12.
Clin Chem Lab Med ; 56(6): 954-963, 2018 05 24.
Artículo en Inglés | MEDLINE | ID: mdl-29303771

RESUMEN

BACKGROUND: The integrated evaluation of traditional and innovative red blood cell (RBC) and reticulocyte parameters is a rapid, inexpensive and non-invasive diagnostic tools for differential diagnosis and follow-up of anemia and other pathological conditions needing bone marrow erythropoiesis assessment. Therefore, estimating the biological variation (BV) of these parameters is essential for evaluating the analytical performance of hematological analyzers, and for enabling accurate data interpretation and appropriate clinical management. This study aims to define short- and medium-term BV estimates and reference change value (RCV) of RBC and reticulocyte parameters. METHODS: Twenty-one healthy volunteers participated in the assessment of medium-term BV (blood sampling once/week, five consecutive weeks) and 22 volunteers in the assessment of short-term BV (blood sampling once/day, five consecutive days) using Sysmex XN. Outlier analysis was performed before CV-ANOVA, to determine BV estimates with confidence intervals (CI). RESULTS: Medium- and short-term within-subject BV were between 0.3% and 16.4% and 0.2%-10.4% (MCH and IRF), respectively, whereas medium and short-term between-subjects BV ranged between 0.9% and 66.6% (MCHC and Micro-R) and 1.4%-43.6% (MCHC and IRF), respectively. The RCVs were similar for all parameters in both arms of the study, except for hemoglobin, RDW-CV and MCV. CONCLUSIONS: This study allowed for estimating the BV of many RBC and reticulocyte parameters, some of which have not been currently explored. For RBC, hemoglobin, RDW-CV and MCV it seems advisable to use RCV calculated according to monitoring time and/or differentiated by sex. As regards analytical goals, we suggest using the most stringent targets found in the short-term arm of this study.


Asunto(s)
Eritrocitos/citología , Valores de Referencia , Reticulocitos/citología , Adolescente , Adulto , Femenino , Humanos , Masculino , Adulto Joven
13.
J Clin Pathol ; 71(4): 330-335, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28824010

RESUMEN

AIMS: This study was aimed to investigate the role of erythrocyte, platelet and reticulocyte (RET) parameters, measured by new haematological analyser Sysmex XN and C reactive protein (CRP), for early diagnosis of sepsis during intensive care unit (ICU) stay. METHODS: The study population consisted of 62 ICU patients, 21 of whom developed sepsis during ICU stay and 41 who did not. The performance for early diagnosing of sepsis was calculated as area under the curve (AUC) of receiver operating characteristics curves analysis. RESULTS: Compared with CRP (AUC 0.81), immature platelet fraction (IPF) (AUC 0.82) showed comparable efficiency for identifying the onset of sepsis. The association with the risk of developing sepsis during ICU stay was also assessed. One day before the onset of sepsis, a decreased of RET% was significantly associated with the risk of developing sepsis (OR=0.35, 95% CI 0.14 to 0.87), whereas an increased of IPF absolute value (IPF#) was significantly associated with the risk of developing sepsis (OR=1.13, 95% CI 1.03 to 1.24) 2 days before the onset of sepsis. The value of CRP was not predictive of sepsis at either time points. CONCLUSIONS: IPF# and RET% may provide valuable clinical information for predicting the risk of developing sepsis, thus allowing early management of patients before the onset of clinically evident systemic infections.


Asunto(s)
Pruebas Hematológicas/métodos , Sepsis/sangre , Sepsis/diagnóstico , Adulto , Anciano , Área Bajo la Curva , Diagnóstico Precoz , Femenino , Humanos , Unidades de Cuidados Intensivos , Masculino , Persona de Mediana Edad , Curva ROC , Sensibilidad y Especificidad
14.
Clin Chim Acta ; 473: 147-156, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28705776

RESUMEN

BACKGROUND: Recent studies showed that some cell population data (CPD) parameters of neutrophils may be useful for diagnosing myelodysplastic syndromes and sepsis, for the differential diagnosis of acute promyelocytic leukemia, and some CPD parameters of lymphocytes may be a valuable tool for preliminary screening of B cell lymphoproliferative disease. Notwithstanding the knowledge, no information has been made available about their analytical quality specification. This study was aimed to define short- and medium-term biological variation (BV) estimates and reference change value (RCV) of leukocyte count, extended leukocyte differential and CPD. METHODS: The study population consisted of 43 healthy volunteers, who participated in the assessment of medium-term (21 volunteers; blood sampling once a week for 5 consecutive weeks) and short-term (22 volunteers; blood sampling once a day for 5 consecutive days) BV, using Sysmex XN. Outlier analysis was carried out before CV-ANOVA, to determine BV estimates and their confidence intervals. RESULTS: The medium-term and short-term within-subject BV (CVI) was comprised between 0.6-19.7% and 0.2-21.9%, whereas the medium-term and short-term between-subjects BV (CVG) was comprised between 1.2-61.5% and 1.1-58.5%. The RCVs were found to be similar for all the parameters, in both arms of the study, except for some CPD parameters. CONCLUSION: This study allowed accurately estimating the BV of many leukocyte parameters, some of which have not been currently explored. The kinetics of some leukocyte turnover suggests the use of short-term BV data for calculating analytical goals and RCV.


Asunto(s)
Voluntarios Sanos , Recuento de Leucocitos/normas , Leucocitos/citología , Adulto , Femenino , Humanos , Masculino , Valores de Referencia , Factores de Tiempo
15.
Clin Chim Acta ; 470: 125-132, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28479317

RESUMEN

BACKGROUND: This study was aimed to define the short- and medium-term biological variation (BV) estimates, the index of individuality and the reference change value (RCV) of platelet count, platelet distribution width, mean platelet volume, platelet larger cell ratio, plateletcrit and immature platelet fraction. METHODS: The study population consisted of 43 health subjects, who participated to the assessment of medium-term (21 subjects; blood sampling once a week for 5 consecutive weeks) and short-term (22 subjects; blood sampling once a day for 5 consecutive days) BV study, using Sysmex XN-module. Eight subjects were also scheduled to participate to both phases. The data were subject to outlier analysis prior to CV-ANOVA, to determine the BV estimates with the relative confidence intervals. RESULTS: The medium-term and short-term within-subject BV (CVI) was comprised between 2.3 and 7.0% and 1.1-8.6%, whereas the medium-term and short-term between-subjects BV (CVG) was comprised between 7.1 and 20.7% and 6.8-48.6%. The index of individuality and index of heterogeneity were always respectively <0.6 and >0.63 for all the parameters, in both arms of the study. The RCVs were similar for all parameters, in both arms of the study. CONCLUSION: This study allowed to define the BV estimates of many platelet parameters, some of them unavailable in literature. The kinetics of platelet turnover suggests the use of short-term BV data for calculating analytical goals and RCV. The correct clinical interpretation of platelet parameters also necessitates that each laboratory estimates local RCV values.


Asunto(s)
Plaquetas/citología , Hematología/métodos , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad
16.
J Clin Lab Anal ; 31(4)2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27709664

RESUMEN

BACKGROUND: This article was aimed to test the use of validation rules for blood smear review after automated hematological testing using Mindray CAL-8000 (two hematological analyzers and one autoslider). METHODS: This study was based on 1013 peripheral blood samples (PB) referred for routine hematological testing. Results of testing on CAL-8000 were analyzed using both locally derived and International Consensus Group for Hematology (ICGH) validation rules, and then compared with data obtained by optical microscopy (OM). A workflow analysis was also completed. RESULTS: The overall agreement with locally derived and ICGH criteria was 91% and 85%, but a higher sensitivity was observed for locally derived criteria (0.97 vs 0.95). The percentage of false negative and false positive samples was 2.1% and 7.1% using ICGH criteria, and was 1.4% and 14% using locally defined rules. The throughput of CAL-8000 system was 208 samples/h, with a percentage of OM analysis comprised between 14% and 17%, and sensitivity of 0.97. As regards personnel activity, we estimated 0.8 full-time equivalent (FTE) of technical staff and 0.7 FTE of personnel for clinical validation of data and blood smear review. CONCLUSION: These results show that customization of validation rules is necessary for enhancing the quality of hematological testing and optimizing workflow.


Asunto(s)
Automatización de Laboratorios/normas , Pruebas Hematológicas/normas , Niño , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
17.
Ann Transl Med ; 4(21): 418, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27942509

RESUMEN

BACKGROUND: This study evaluated the clinical significance of cell population data (CPD) parameters obtained on Sysmex XN-9000 in septic patients admitted to intensive care unit (ICU) and stratified according to liver function. METHODS: The study population consisted in 84 patients, 44 of whom did not develop sepsis (NS), whereas the remaining 40 developed sepsis (SE) (n=24) or septic shock (SS) (n=16). Two hundred ostensibly healthy blood donors [healthy subjects (HS)], undergoing routine blood testing before a regular blood donation, were studied. RESULTS: Except for neutrophils and lymphocytes cell size (NE-FCS and LY-Z), all other CPD values were significantly different in ICU patients compared to HS. Neutrophils and monocytes fluorescence intensity (NE-SFL and MO-X) values were significantly higher in SS compared to sepsis and not develop sepsis patients. The value of many parameters was also different according to liver function. Overall, MO-X and neutrophils fluorescence intensity (NE-SFL) exhibited the best performance for diagnosing sepsis in all patients (AUC, 0.75 and 0.72), as well as in those with (AUC, 0.95 and 0.89) or without (AUC, 0.72 for both) liver impairment. These parameters were also significantly correlated with Sequential Organ Failure Assessment (SOFA) score. CONCLUSIONS: This study suggested that some novel CPD parameters (namely NE-SFL and MO-X) may provide useful information for diagnosis and management of sepsis.

18.
Clin Chim Acta ; 462: 41-48, 2016 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-27581597

RESUMEN

BACKGROUND: This study was planned to assess the impact of pre-treating synovial fluid (SF) samples with hyaluronidase (HY), defining the best procedure for optical microscopy (OM) analysis and evaluating the performance of Sysmex XN-9000 Body Fluid module (XN-BF). METHODS: The cell count by OM was carried out both with and without HY pre-treatment, and using 3 different types of staining reagents. The evaluation of XN-BF included data comparison with OM (100 SFs), carryover, Limit of Blank (LoB), Limit of Detection (LoD), Limit of Quantitation (LoQ) and linearity. RESULTS: Unlike cell count in Burker's chamber and staining with Stromatol, pre-treatment with HY and staining with Methylene Blue and Turk's promoted cell clustering. The SF samples pre-treated with HY displayed excellent morphological quality, contrary to samples without HY pre-treatment. Excellent correlation was found between total cells counting with both OM and XN-BF. Satisfactory agreement was also observed between polymorphonuclear neutrophils compared to XN-BF parameter, whereas mononuclear cell count on XN-BF had suboptimal agreement with OM. The carryover was negligible. The LoB, LoD, LoQ and linearity were excellent. CONCLUSION: XN-BF displays excellent performance, which makes it a reliable and practical alternative to OM for SF samples analysis in clinical laboratories.


Asunto(s)
Automatización de Laboratorios/instrumentación , Recuento de Células/instrumentación , Citometría de Flujo/instrumentación , Líquido Sinovial/citología , Diferenciación Celular , Humanos , Microscopía , Fenómenos Ópticos
19.
Rev Bras Hematol Hemoter ; 38(3): 225-39, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27521861

RESUMEN

BACKGROUND: Different hematological analyzers have different analytical performances that are often reflected in the criteria for sample stability of the complete blood count. This study aimed to assess the stability of several hematological parameters using the XN-9000 Sysmex and BC-6800 Mindray analyzers. METHODS: The impact of storage at room temperature and 4°C was evaluated after 2, 4, 6, 8, 24, 36 and 48h using ten normal and 40 abnormal blood samples. The variation from the baseline measurement was evaluated by the Steel-Dwass-Critchlow-Fligner test and by Bland-Altman plots, using quality specifications and critical difference as the total allowable variation. RESULTS: Red blood cells and reticulocyte parameters (i.e. hematocrit, mean corpuscular volume, mean corpuscular hemoglobin concentration, red blood cell distribution width, immature reticulocyte fractions, low-fluorescence reticulocytes, middle-fluorescence reticulocytes, high fluorescence mononuclear cells) showed less stability compared to leukocyte and platelet parameters (except for monocyte count and mean platelet volume). The bias for hematocrit, mean corpuscular volume, mean corpuscular hemoglobin concentration and red blood cell distribution width coefficient of variation was higher than the critical difference after 8h using both analyzers. CONCLUSION: Blood samples measured with both analyzers do not show analytically significant changes in up to 2h of storage at room temperature and 4°C. However, the maximum time for analysis can be extended for up to 8h when the bias is compared to the critical difference.

20.
J Clin Lab Anal ; 30(5): 381-91, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26302990

RESUMEN

BACKGROUND: We evaluated the new body fluid module on Sysmex UF1000-i (UF1000i-BF) for analysis of white blood cell (WBC) and red blood cell (RBC) in cerebrospinal fluid (CSF). METHODS: WBC and RBC counting were compared between UF1000i-BF and Fuchs-Rosenthal counting chamber in 67 CSF samples. This study also included the evaluation of between-day precision, limit of blank (LoB), limit of detection (LoD), functional sensitivity (limit of quantitation, LoQ), carryover and linearity. Diagnostic agreement for differentiation between normal and increased WBC counts (≥5.0 × 10(6) /L) was also assessed. RESULTS: The agreement between UF1000i-BF and manual WBC counts was otpiaml in all CSF samples (r = 0.99; y = 1.05x + 0.09). A modest overestimation was noticed in samples with WBC < 30 × 10(6) /L (r = 0.95; y = 1.21x - 0.15). A good agreement was observed for RBC counts (r = 0.98; y = 1.15x + 0.55), particularly in samples with RBC ≥ 18 × 10(6) /L (r = 0.98; y = 1.01x + 8.90). Between-day precision was good, with coefficient of variations (CVs) lower than 7.2% for both WBC and RBC. The LoBs were 0.1 × 10(6) WBC/L and 1.2 × 10(6) RBC/L, the LoDs were 0.7 × 10(6) WBC/L and 5.5 × 10(6) RBC/L, the LoQs were 2.4 × 10(6) WBC/L and 18.0 × 10(6) RBC/L, respectively. Linearity was excellent (r = 1.00 for both WBC and RBC). Carryover was negligible. Excellent diagnostic agreement was obtained at 4.5 × 10(6) WBC/L cut-off (sensitivity, 100%; specificity, 97.4%). CONCLUSION: The UF1000i-BF provides rapid and accurate WBC and RBC counts in clinically relevant values of CSF cells. The use of UF1000i-BF may hence allow to replace routine optical counting, except for samples displaying abnormal WBC counts or abnormal scattergram distribution, for which differential cell counts may still be required.


Asunto(s)
Automatización de Laboratorios/métodos , Líquidos Corporales/citología , Líquido Cefalorraquídeo/citología , Recuento de Eritrocitos , Leucocitos , Adolescente , Adulto , Área Bajo la Curva , Automatización de Laboratorios/instrumentación , Humanos , Recuento de Leucocitos , Modelos Lineales , Masculino , Paracentesis , Adulto Joven