Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Environ Pollut ; 345: 123475, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38331241

RESUMEN

Indoor dust can contribute substantially to human exposure to known and contaminants of emerging concern (CECs). Novel compounds with high structural variability and different homologues are frequently discovered through screening of the indoor environment, implying that constant monitoring is required. The present study aimed at the identification and semi-quantification of CECs in 46 indoor dust samples collected in Belgium by liquid chromatography high-resolution mass spectrometry. Samples were analyzed applying a targeted and suspect screening approach; the latter based on a suspect list containing >4000 CECs. This allowed the detection of a total of 55 CECs, 34 and 21 of which were identified with confidence level (CL) 1/2 or CL 3, respectively. Besides numerous known contaminants such as di(2-ethylhexyl) phthalate (DEHP), di(2-ethylhexyl) adipate (DEHA) or tris(2-butoxyethyl) phosphate (TBOEP) which were reported with detection frequencies (DFs) > 90%, several novel CECs were annotated. These included phthalates with differing side chains, such as decyl nonyl and decyl undecyl phthalate detected with DFs >80% and identified through the observation of characteristic neutral losses. Additionally, two novel organophosphate flame retardants not previously described in indoor dust, i.e. didecyl butoxyethoxyethyl phosphate (DDeBEEP) and bis(butoxyethyl) butyl phosphate (BBEBP), were identified. The implementation of a dedicated workflow provided semi-quantitative concentrations for a set of suspects. Such data obtained for novel phthalates were in the same order of magnitude as the concentrations observed for legacy phthalates indicating their high relevance for human exposure. From the semi-quantitative data, estimated daily intakes and resulting hazard quotients (HQs) were calculated to estimate the exposure and potential health effects. Neither of the obtained HQ values exceeded the risk threshold, indicating no expected adverse health effects.


Asunto(s)
Contaminación del Aire Interior , Retardadores de Llama , Ácidos Ftálicos , Humanos , Monitoreo del Ambiente/métodos , Contaminación del Aire Interior/análisis , Polvo/análisis , Ácidos Ftálicos/análisis , Organofosfatos/análisis , Espectrometría de Masas , Fosfatos/análisis , Medición de Riesgo , Retardadores de Llama/análisis , Exposición a Riesgos Ambientales/análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...