Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Pharm Biomed Anal ; 213: 114684, 2022 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-35220202

RESUMEN

Biocatalytic processes have become more prevalent in the pharmaceutical industry, leading to analytical challenges not faced when characterizing more traditional synthetic routes. A novel one-pot biocatalytic process has been established for Islatravir, an HIV reverse transcriptase translocation inhibitor for the treatment and prevention of HIV-1. As a one-pot reaction, the Islatravir chemistry contains multiple intermediates that are not isolated. Additionally, these unisolated intermediates have no chromophores, making traditional LC-UV techniques ineffective for characterization. A hydrophilic interaction chromatography (HILIC) method with a charged aerosol detector (CAD) was initially developed, however numerous inorganic species present in the one-pot reaction were retained; this led to co-elution of compounds and poor peak shapes. An innovative ion-pairing LC method was developed in order to resolve inorganic species, intermediates, and the API, for use during in-process control of the Islatravir biocatalytic reaction. Aided by a volatile ion-pairing reagent compatible with the CAD, this method successfully retains and resolves the highly polar intermediates of interest and Islatravir API. This novel method was successfully validated and has allowed the Islatravir biocatalytic process to be fully characterized from the early intermediates through the final API within the one-pot reaction without the need for isolations. This novel ion-pairing HPLC-CAD technique lays the groundwork for method development on current and future biocatalytic-produced drug substances.


Asunto(s)
Desoxiadenosinas , Aerosoles , Cromatografía Líquida de Alta Presión/métodos , Interacciones Hidrofóbicas e Hidrofílicas
2.
Anal Bioanal Chem ; 411(23): 6155-6163, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31300857

RESUMEN

Electrophoresis has demonstrated utility as tool for screening of small molecule modulators of protein-protein interactions and enzyme targets. Screening of large chemical libraries requires high-throughput separations. Such fast separation can be accessed by microchip electrophoresis. Here, microchip gel electrophoresis separations of proteins are achieved in 2.6 s with 1200 V/cm and 3-mm separation lengths. However, such fast separations can still suffer from limited overall throughput from sample introduction constraints. Automated introduction of microfluidic droplets has been demonstrated to overcome this limitation. Most devices for coupling microfluidic droplets to microchip electrophoresis are only compatible with free-solution separations. Here, we present a device that is compatible with coupling droplets to gel and free-solution electrophoresis. In this device, automated sample introduction is based on a novel mechanism of carrier phase separation using the difference in density of the carrier phase and the running buffer. This device is demonstrated for microchip gel electrophoresis and free-solution electrophoresis separations of protein-protein interaction and enzyme samples, respectively. Throughputs of about 10 s per sample are achieved and over 1000 separations are demonstrated without reconditioning of the device. Graphical abstract.


Asunto(s)
Electroforesis por Microchip/instrumentación , Mapeo de Interacción de Proteínas/instrumentación , Biocatálisis , Diseño de Equipo , Geles/química , Mapas de Interacción de Proteínas , Proteínas/metabolismo
3.
Analyst ; 143(8): 1805-1812, 2018 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-29565056

RESUMEN

Tools for measuring affinities and stoichiometries of protein-protein complexes are valuable for elucidating the role of protein-protein interactions (PPIs) in governing cell functions and screening for PPI modulators. Such measurements can be challenging because PPIs can span a wide range of affinities and include stoichiometries from dimers to high order oligomers. Also, most techniques require large amounts of protein which can hamper research for difficult to obtain proteins. Protein cross-linking capillary electrophoresis (PXCE) has the potential to directly measure PPIs and even resolve multiple PPIs while consuming attomole quantities. Previously PXCE has only been used for high affinity, 1 : 1 complexes; here we expand the utility of PXCE to access a wide range of PPIs including weak and multimeric oligomers. Use of glutaraldehyde as the cross-linking agent was key to advancing the method because of its rapid reaction kinetics. A 10 s reaction time was found to be sufficient for cross-linking and quantification of seven different PPIs with Kd values ranging from low µM to low nM including heat shock protein 70 (Hsp70) interacting with heat shock organizing protein (3.8 ± 0.7 µM) and bcl2 associated anthanogene (26 ± 6 nM). Non-specific cross-linking of protein aggregates was found to be minimal at protein concentrations <20 µM as assessed by size exclusion chromatography. PXCE was sensitive enough to measure changes in PPI affinity induced by the protein nucleotide state or point mutations in the protein-binding site. Further, several interactions could be resolved in a single run, including Hsp70 monomer, homodimer and Hsp70 complexed the with c-terminus of Hsp70 interacting protein (CHIP). Finally, the throughput of PXCE was increased to 1 min per sample suggesting potential for utility in screening.


Asunto(s)
Electroforesis Capilar , Proteínas HSP70 de Choque Térmico/química , Unión Proteica , Mapeo de Interacción de Proteínas , Sitios de Unión , Reactivos de Enlaces Cruzados , Glutaral , Humanos
4.
Expert Opin Drug Discov ; 12(2): 213-224, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27911223

RESUMEN

INTRODUCTION: Many screening platforms are prone to assay interferences that can be avoided by directly measuring the target or enzymatic product. Capillary electrophoresis (CE) and microchip electrophoresis (MCE) have been applied in a variety of formats to drug discovery. CE provides direct detection of the product allowing for the identification of some forms of assay interference. The high efficiency, rapid separations, and low volume requirements make CE amenable to drug discovery. Areas covered: This article describes advances in capillary electrophoresis throughput, sample introduction, and target assays as they pertain to drug discovery and screening. Instrumental advances discussed include integrated droplet microfluidics platforms and multiplexed arrays. Applications of CE to assays of diverse drug discovery targets, including enzymes and affinity interactions are also described. Expert opinion: Current screening with CE does not fully take advantage of the throughputs or low sample volumes possible with CE and is most suitable as a secondary screening method or for screens that are inaccessible with more common platforms. With further development, droplet microfluidics coupled to MCE could take advantage of the low sample requirements by performing assays on the nanoliter scale at high throughput.


Asunto(s)
Descubrimiento de Drogas/métodos , Electroforesis Capilar/métodos , Electroforesis por Microchip/métodos , Ensayos Analíticos de Alto Rendimiento/métodos , Humanos , Técnicas Analíticas Microfluídicas/métodos , Terapia Molecular Dirigida
5.
Anal Chem ; 88(16): 8272-8, 2016 08 16.
Artículo en Inglés | MEDLINE | ID: mdl-27434096

RESUMEN

Capillary electrophoresis (CE) has been identified as a useful platform for detecting, quantifying, and screening for modulators of protein-protein interactions (PPIs). In this method, one protein binding partner is labeled with a fluorophore, the protein binding partners are mixed, and then, the complex is separated from free protein to allow direct determination of bound to free ratios. Although it possesses many advantages for PPI studies, the method is limited by the need to have separation conditions that both prevent protein adsorption to capillary and maintain protein interactions during the separation. In this work, we use protein cross-linking capillary electrophoresis (PXCE) to overcome this limitation. In PXCE, the proteins are cross-linked under binding conditions and then separated. This approach eliminates the need to maintain noncovalent interactions during electrophoresis and facilitates method development. We report PXCE methods for an antibody-antigen interaction and heterodimer and homodimer heat shock protein complexes. Complexes are cross-linked by short treatments with formaldehyde after reaching binding equilibrium. Cross-linked complexes are separated by electrophoretic mobility using free solution CE or by size using sieving electrophoresis of SDS complexes. The method gives good quantitative results; e.g., a lysozyme-antibody interaction was found to have Kd = 24 ± 3 nM by PXCE and Kd = 17 ± 2 nM using isothermal calorimetry (ITC). Heat shock protein 70 (Hsp70) in complex with bcl2 associated athanogene 3 (Bag3) was found to have Kd = 25 ± 5 nM by PXCE which agrees with Kd values reported without cross-linking. Hsp70-Bag3 binding site mutants and small molecule inhibitors of Hsp70-Bag3 were characterized by PXCE with good agreement to inhibitory constants and IC50 values obtained by a bead-based flow cytometry protein interaction assay (FCPIA). PXCE allows rapid method development for quantitative analysis of PPIs.


Asunto(s)
Reacciones Antígeno-Anticuerpo/fisiología , Proteínas Reguladoras de la Apoptosis/química , Reactivos de Enlaces Cruzados/química , Electroforesis Capilar , Proteínas de Choque Térmico/química , Proteínas Reguladoras de la Apoptosis/metabolismo , Sitios de Unión , Calorimetría , Dimerización , Colorantes Fluorescentes/química , Formaldehído/química , Proteínas de Choque Térmico/metabolismo , Muramidasa/química , Muramidasa/metabolismo , Unión Proteica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...