Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38663995

RESUMEN

BACKGROUND: We aimed to investigate the clinical, imaging and fluid biomarker characteristics in patients with antidiacylglycerol lipase alpha (DAGLA)-autoantibody-associated cerebellitis. METHODS: Serum and cerebrospinal fliud (CSF) samples from four index patients were subjected to comprehensive autoantibody screening by indirect immunofluorescence assay (IIFA). Immunoprecipitation, mass spectrometry and recombinant protein assays were used to identify the autoantigen. Sera from 101 patients with various neurological symptoms and a similar tissue staining pattern as the index patient samples, and 102 healthy donors were analysed in recombinant cell-based IIFA (RC-IIFA) with the identified protein. Epitope characterisation of all positive samples was performed via ELISA, immunoblot, immunoprecipitation and RC-IIFA using different DAGLA fragments. RESULTS: All index patients were relatively young (age: 18-34) and suffered from pronounced gait ataxia, dysarthria and visual impairments. Paraclinical hallmarks in early-stage disease were inflammatory CSF changes and cerebellar cortex hyperintensity in MRI. Severe cerebellar atrophy developed in three of four patients within 6 months. All patient samples showed the same unclassified IgG reactivity with the cerebellar molecular layer. DAGLA was identified as the target antigen and confirmed by competitive inhibition experiments and DAGLA-specific RC-IIFA. In RC-IIFA, serum reactivity against DAGLA was also found in 17/101 disease controls, including patients with different clinical phenotypes than the one of the index patients, and in 1/102 healthy donors. Epitope characterisation revealed that 17/18 anti-DAGLA-positive control sera reacted with a C-terminal intracellular DAGLA 583-1042 fragment, while the CSF samples of the index patients targeted a conformational epitope between amino acid 1 and 157. CONCLUSIONS: We propose that anti-DAGLA autoantibodies detected in CSF, with a characteristic tissue IIFA pattern, represent novel biomarkers for rapidly progressive cerebellitis.

2.
Clin Chem Lab Med ; 2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38534005

RESUMEN

BACKGROUND: The EFLM Task and Finish Group Urinalysis has updated the ECLM European Urinalysis Guidelines (2000) on urinalysis and urine bacterial culture, to improve accuracy of these examinations in European clinical laboratories, and to support diagnostic industry to develop new technologies. RECOMMENDATIONS: Graded recommendations were built in the following areas. MEDICAL NEEDS AND TEST REQUISITION: Strategies of urine testing are described to patients with complicated or uncomplicated urinary tract infection (UTI), and high or low-risk to kidney disease. SPECIMEN COLLECTION: Patient preparation, and urine collection are supported with two quality indicators: contamination rate (cultures), and density of urine (chemistry, particles). CHEMISTRY: Measurements of both urine albumin and α1-microglobulin are recommended for sensitive detection of kidney disease in high-risk patients. Performance specifications are given for urine protein measurements and quality control of multiproperty strip tests. PARTICLES: Procedures for microscopy are reviewed for diagnostic urine particles, including urine bacteria. Technologies in automated particle counting and visual microscopy are updated with advice how to verify new instruments with the reference microscopy. BACTERIOLOGY: Chromogenic agar is recommended as primary medium in urine cultures. Limits of significant growth are reviewed, with an optimised workflow for routine specimens, using leukocyturia to reduce less important antimicrobial susceptibility testing. Automation in bacteriology is encouraged to shorten turn-around times. Matrix assisted laser desorption ionization time-of-flight mass spectrometry is applicable for rapid identification of uropathogens. Aerococcus urinae, A. sanguinicola and Actinotignum schaalii are taken into the list of uropathogens. A reference examination procedure was developed for urine bacterial cultures.

3.
Eur J Clin Microbiol Infect Dis ; 43(1): 177-185, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37953413

RESUMEN

We assessed the humoral and cellular immune responses after two booster mRNA vaccine administrations [BNT162b2 (Pfizer-BioNTech vaccine)] in cohorts of immunocompromised patients (n = 199) and healthy controls (HC) (n = 54). All patients living with HIV (PLWH) and chronic kidney disease (CKD) patients and almost all (98.2%) of the primary immunodeficiency (PID) patients had measurable antibodies 3 and 6 months after administration of the third and fourth vaccine dose, comparable to the HCs. In contrast, only 53.3% and 83.3% of the multiple sclerosis (MS) and rheumatologic patients, respectively, developed a humoral immune response. Cellular immune response was observed in all PLWH after administration of four vaccine doses. In addition, cellular immune response was positive in 89.6%, 97.8%, 73.3% and 96.9% of the PID, MS, rheumatologic and CKD patients, respectively. Unlike the other groups, only the MS patients had a significantly higher cellular immune response compared to the HC group. Administration of additional vaccine doses results in retained or increased humoral and cellular immune response in patients with acquired or inherited immune disorders.


Asunto(s)
Artritis Reumatoide , COVID-19 , Esclerosis Múltiple , Insuficiencia Renal Crónica , Humanos , SARS-CoV-2 , Vacuna BNT162 , COVID-19/prevención & control , Vacunación , Huésped Inmunocomprometido , Inmunidad Humoral , Anticuerpos Antivirales
5.
J Clin Med ; 12(23)2023 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-38068480

RESUMEN

Raman spectroscopy, a non-invasive diagnostic technique capturing molecular vibrations, offers significant advancements in skin cancer diagnostics. This review delineates the ascent of Raman spectroscopy from classical methodologies to the forefront of modern technology, emphasizing its precision in differentiating between malignant and benign skin tissues. Our study offers a detailed examination of distinct Raman spectroscopic signatures found in skin cancer, concentrating specifically on squamous cell carcinoma, basal cell carcinoma, and melanoma, across both in vitro and in vivo research. The discussion extends to future possibilities, spotlighting enhancements in portable Raman instruments, the adoption of machine learning for spectral data refinement, and the merging of Raman imaging with other diagnostic techniques. The review culminates by contemplating the broader implications of these advancements, suggesting a trajectory that may significantly optimize the accuracy and efficiency of skin cancer diagnostics.

6.
Int J Mol Sci ; 24(23)2023 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-38069330

RESUMEN

Hematological diseases, due to their complex nature and diverse manifestations, pose significant diagnostic challenges in healthcare. The pressing need for early and accurate diagnosis has driven the exploration of novel diagnostic techniques. Infrared (IR) spectroscopy, renowned for its noninvasive, rapid, and cost-effective characteristics, has emerged as a promising adjunct in hematological diagnostics. This review delves into the transformative role of IR spectroscopy and highlights its applications in detecting and diagnosing various blood-related ailments. We discuss groundbreaking research findings and real-world applications while providing a balanced view of the potential and limitations of the technique. By integrating advanced technology with clinical needs, we offer insights into how IR spectroscopy may herald a new era of hematological disease diagnosis.


Asunto(s)
Enfermedades Hematológicas , Hematología , Humanos , Espectroscopía Infrarroja por Transformada de Fourier/métodos , Espectrofotometría Infrarroja/métodos , Enfermedades Hematológicas/diagnóstico
7.
Diagnostics (Basel) ; 13(19)2023 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-37835820

RESUMEN

Uromodulin, also known as Tamm-Horsfall protein, represents the predominant urinary protein in healthy individuals. Over the years, studies have revealed compelling associations between urinary and serum concentrations of uromodulin and various parameters, encompassing kidney function, graft survival, cardiovascular disease, glucose metabolism, and overall mortality. Consequently, there has been a growing interest in uromodulin as a novel and effective biomarker with potential applications in diverse clinical settings. Reduced urinary uromodulin levels have been linked to an elevated risk of acute kidney injury (AKI) following cardiac surgery. In the context of chronic kidney disease (CKD) of different etiologies, urinary uromodulin levels tend to decrease significantly and are strongly correlated with variations in estimated glomerular filtration rate. The presence of uromodulin in the serum, attributable to basolateral epithelial cell leakage in the thick ascending limb, has been observed. This serum uromodulin level is closely associated with kidney function and histological severity, suggesting its potential as a biomarker capable of reflecting disease severity across a spectrum of kidney disorders. The UMOD gene has emerged as a prominent locus linked to kidney function parameters and CKD risk within the general population. Extensive research in multiple disciplines has underscored the biological significance of the top UMOD gene variants, which have also been associated with hypertension and kidney stones, thus highlighting the diverse and significant impact of uromodulin on kidney-related conditions. UMOD gene mutations are implicated in uromodulin-associated kidney disease, while polymorphisms in the UMOD gene show a significant association with CKD. In conclusion, uromodulin holds great promise as an informative biomarker, providing valuable insights into kidney function and disease progression in various clinical scenarios. The identification of UMOD gene variants further strengthens its relevance as a potential target for better understanding kidney-related pathologies and devising novel therapeutic strategies. Future investigations into the roles of uromodulin and regulatory mechanisms are likely to yield even more profound implications for kidney disease diagnosis, risk assessment, and management.

8.
Clin Chem ; 69(12): 1348-1360, 2023 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-37708293

RESUMEN

BACKGROUND: Artificial intelligence (AI) has emerged as a promising and transformative tool in the field of urinalysis, offering substantial potential for advancements in disease diagnosis and the development of predictive models for monitoring medical treatment responses. CONTENT: Through an extensive examination of relevant literature, this narrative review illustrates the significance and applicability of AI models across the diverse application area of urinalysis. It encompasses automated urine test strip and sediment analysis, urinary tract infection screening, and the interpretation of complex biochemical signatures in urine, including the utilization of cutting-edge techniques such as mass spectrometry and molecular-based profiles. SUMMARY: Retrospective studies consistently demonstrate good performance of AI models in urinalysis, showcasing their potential to revolutionize clinical practice. However, to comprehensively evaluate the real clinical value and efficacy of AI models, large-scale prospective studies are essential. Such studies hold the potential to enhance diagnostic accuracy, improve patient outcomes, and optimize medical treatment strategies. By bridging the gap between research and clinical implementation, AI can reshape the landscape of urinalysis, paving the way for more personalized and effective patient care.


Asunto(s)
Inteligencia Artificial , Líquidos Corporales , Humanos , Estudios Prospectivos , Estudios Retrospectivos , Urinálisis
10.
Clin Chem Lab Med ; 61(12): 2186-2194, 2023 11 27.
Artículo en Inglés | MEDLINE | ID: mdl-37340894

RESUMEN

OBJECTIVES: Well-standardized procedures in the pre-analytical phase of urine diagnostics is of utmost importance to obtain reliable results. We investigated the effect of different urine collection methods and the associated urine transfer tubes on urine test strip and particle results. METHODS: In total, 146 selected urine samples were subdivided into three different collection containers and subsequently transferred into its accompanying transfer tube (BD, Greiner, Sarstedt vacuum and Sarstedt aspiration). As reference, the original urine sample was directly measured on the analyser. Both chemical test strip analysis (Sysmex UC-3500) and fluorescence flow cytometry particle analysis (Sysmex UF-5000) were performed on all samples. RESULTS: No statistically significant differences in test strip results were found between the studied transfer methods. On the contrary, transfer of urine samples to the secondary tubes affected their particle counts. Clinically significant reductions in counts of renal tubular epithelial cells and hyaline casts were observed using the BD and Greiner transfer tubes and in counts of pathological casts using the BD, Greiner and Sarstedt vacuum tubes. CONCLUSIONS: The results of this study indicate that the use of urine transfer tubes may impact counts of fragile urine particles. Clinical laboratories need to be aware about the variation that urine collection methods can induce on urine particle counts.


Asunto(s)
Células Epiteliales , Urinálisis , Humanos , Urinálisis/métodos , Citometría de Flujo/métodos , Vacio , Concienciación , Orina
12.
Clin Chem Lab Med ; 61(8): 1382-1387, 2023 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-37079906

RESUMEN

Detection of hemoglobin (Hb) and red blood cells in urine (hematuria) is characterized by a large number of pitfalls. Clinicians and laboratory specialists must be aware of these pitfalls since they often lead to medical overconsumption or incorrect diagnosis. Pre-analytical issues (use of vacuum tubes or urine tubes containing preservatives) can affect test results. In routine clinical laboratories, hematuria can be assayed using either chemical (test strips) or particle-counting techniques. In cases of doubtful results, Munchausen syndrome or adulteration of the urine specimen should be excluded. Pigmenturia (caused by the presence of dyes, urinary metabolites such as porphyrins and homogentisic acid, and certain drugs in the urine) can be easily confused with hematuria. The peroxidase activity (test strip) can be positively affected by the presence of non-Hb peroxidases (e.g. myoglobin, semen peroxidases, bacterial, and vegetable peroxidases). Urinary pH, haptoglobin concentration, and urine osmolality may affect specific peroxidase activity. The implementation of expert systems may be helpful in detecting preanalytical and analytical errors in the assessment of hematuria. Correcting for dilution using osmolality, density, or conductivity may be useful for heavily concentrated or diluted urine samples.


Asunto(s)
Hematuria , Peroxidasa , Humanos , Hematuria/etiología , Hemoglobinas , Eritrocitos , Concentración Osmolar
14.
Clin Chem Lab Med ; 60(11): 1772-1779, 2022 10 26.
Artículo en Inglés | MEDLINE | ID: mdl-36069776

RESUMEN

OBJECTIVES: Urinary test strip and sediment analysis integrated with intelligent verification criteria can help to select samples that need manual review. This study aimed to evaluate the improvement in the diagnostic performance of combined urinary test strip and urinary sediment analysis using intelligent verification criteria on the latest generation automated test strip and urinary fluoresce flow cytometry (UFFC) analysers. METHODS: Urine test strip and sediment analysis were performed using the Sysmex UC-3500 and UF-5000 (Kobe, Japan) on 828 urinary samples at the clinical laboratory of the Ghent University Hospital. The results were compared to manual microscopy using phase-contrast microscopy as a reference. After the application of the intelligent verification criteria, we determined whether the diagnostic performance of urine sediment analysis could be improved. RESULTS: Application of intelligent verification criteria resulted in an increase in specificity from 88.5 to 96.8% and from 88.2 to 94.9% for red blood cells and white blood cells, respectively. Implementing review rules for renal tubular epithelial cells and pathological casts increased the specificity from 66.7 to 74.2% and from 96.2 to 100.0%, respectively; and improved the diagnostic performance of urinary crystals and atypical cells. CONCLUSIONS: The implementation of review rules improved the diagnostic performance of UFFC, thereby increasing the reliability and quality of urine sediment results.


Asunto(s)
Microscopía , Urinálisis , Recuento de Eritrocitos , Citometría de Flujo/métodos , Humanos , Microscopía/métodos , Reproducibilidad de los Resultados , Urinálisis/métodos , Orina
15.
Ann Lab Med ; 42(5): 566-574, 2022 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-35470274

RESUMEN

Background: Chloride measurement is crucial for calculating the anion gap. Bicarbonate can interfere with chloride measurements; however, there is no information on the specific types of electrodes affected or the changes in bicarbonate non-selectivity over time. We evaluated the interference of bicarbonate on chloride measurements using different electrodes and the stability of this interference over time. Methods: The effect of bicarbonate on chloride measured with electrodes of various manufacturers was assessed. When non-selectivity toward bicarbonate was observed, the stability of this interference during the electrode's lifetime was explored. The impact of the bicarbonate concentration on the calibrator was also evaluated. Results: Non-selectivity was observed for electrodes using quaternary ammonium salts (Beckman Coulter, Siemens, and Roche), with overestimated or underestimated chloride values observed at high or low bicarbonate concentrations, respectively. The degree of selectivity varied among electrodes. With the Roche electrode, interference became more pronounced over time, whereas the Siemens electrode appeared to gain selectivity during its lifetime. For the Roche system, adjusting the calibrator's bicarbonate concentration from 30 mmol/L to 20-24 mmol/L reduced the number of samples with unacceptable bias (>3%) from 77.3% to 12.6%. Lot-to-lot variations in the calibrator bicarbonate concentration increased the uncertainty of chloride measurements. Conclusions: The extent of bicarbonate-induced error varied according to the type, manufacturer, and wear of the electrode; the bicarbonate concentration in the calibrators and the tested sample; and the chloride content. Laboratories should be aware of the impact of bicarbonate on routine chloride measurements to establish appropriate QC procedures.


Asunto(s)
Bicarbonatos , Cloruros , Humanos , Electrodos de Iones Selectos
16.
Front Immunol ; 13: 858399, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35401575

RESUMEN

Background: Immunocompromised patients are at increased risk of severe COVID-19 and impaired vaccine response. In this observational prospective study, we evaluated immunogenicity of the BNT162b2 mRNA vaccine in cohorts of primary or secondary immunocompromised patients. Methods: Five clinical groups of immunocompromised patients [primary immunodeficiency (PID) (n=57), people living with HIV (PLWH) (n=27), secondary immunocompromised patients with a broad variety of underlying rheumatologic (n=23) and homogeneous (multiple sclerosis) neurologic (n=53) conditions and chronic kidney disease (CKD) (n=39)] as well as a healthy control group (n=54) were included. Systemic humoral and cellular immune responses were evaluated by determination of anti-SARS-CoV-2 Spike antibodies using a TrimericS IgG assay (Diasorin) and through quantification of interferon gamma release in response to SARS-CoV-2 antigen with QuantiFERON SARS-CoV-2 assay (Qiagen), respectively. Responses were measured at pre-defined time-points after complete vaccination. Results: All healthy controls, PLWH and CKD-patients had detectable antibodies 10 to 14 days (T2) and 3 months (T3) after administration of the second vaccination. In contrast, only 94.5% of the PID, 50.0% of the rheumatologic and 48.0% of neurologic patients developed antibodies at T2 and only 89.1% of the PID, 52.4% of the rheumatologic and 50.0% of neurologic patients developed antibodies at T3. At T3 no significant differences in cellular response between the healthy control group and the PLWH and CKD groups were found, while proportions of reactive subjects were lower in PID and rheumatologic patients and higher in neurologic patients. Humoral and cellular immune responses significantly correlated in the healthy control, PID, PLWH groups for all 3 antigens. Conclusion: Patients with acquired or inherited immune disorders may show variable immune responses to vaccination with the BNT162b2 mRNA vaccine against SARS-CoV-2. Whether humoral, cellular or both immune responses are delayed depends on the patient group, therapy and individual risk factors. These data may guide the counselling of patients with immune disorders regarding vaccination of SARS-CoV-2.


Asunto(s)
Artritis Reumatoide , COVID-19 , Insuficiencia Renal Crónica , Anticuerpos Antivirales , Vacuna BNT162 , Vacunas contra la COVID-19 , Humanos , Inmunidad Humoral , Huésped Inmunocomprometido , Estudios Prospectivos , ARN Mensajero , SARS-CoV-2 , Vacunas Sintéticas , Vacunas de ARNm
17.
Diagn Microbiol Infect Dis ; 103(1): 115659, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35278794

RESUMEN

We retrospectively compared the long-term evolution of IgG anti-spike (S) and anti-nucleocapsid (N) levels (Abbott immunoassays) in 116 non-severe and 115 severe SARS-CoV-2 infected patients from 2 university hospitals up to 365 days post positive RT-PCR. IgG anti-S and anti-N antibody levels decayed exponentially up to 365 days after a peak 0 to 59 days after positive RT-PCR. Peak antibody level/cut-off ratio 0 to 59 days after positive RT-PCR was more than 70 for anti-S compared to less than 6 for anti-N (P < 0.01). Anti-S and anti-N were significantly higher in severe compared to non-severe patients up to 180 to 239 days and 300 to 365 days, respectively (P < 0.05). Despite similar half-lives, the estimated time to 50% seronegativity was more than 2 years for anti-S compared to less than 1 year for anti-N in non-severe and severe COVID-19 patients, due to the significantly higher peak antibody level/cut-off ratio for anti-S compared to anti-N.


Asunto(s)
COVID-19 , Anticuerpos Antivirales , Humanos , Inmunoglobulina G , Estudios Retrospectivos , SARS-CoV-2 , Sensibilidad y Especificidad
19.
Ther Drug Monit ; 44(2): 335-339, 2022 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-34985848

RESUMEN

BACKGROUND: Therapeutic drug monitoring (TDM) of busulfan is recommended for hematopoietic stem cell transplant recipients. Timely reporting of these TDM results is essential given the short administration period and the planned dose adjustments on day 2. The authors evaluated the performance of a new nanoparticle-based competitive immunoassay on two routine clinical chemistry analyzers and compared its performance to that of an in-house high-resolution mass spectrometry (HRMS) method. METHODS: The MyCare Oncology Busulfan Assay Kit (Saladax Biomedical) was applied on two routine clinical chemistry analyzers (Abbott Architect c8000 and Roche Cobas c502) with a linearity range of 187-2000 ng/mL. The study evaluation measured imprecision and accuracy, sample probe carry-over, and dilution integrity. Method comparison with liquid chromatography (LC)-HRMS was performed using samples from patients undergoing busulfan treatment. RESULTS: Within- and between-run coefficient of variations for both analyzers were ≤5.23% and ≤8.45%, respectively, across the busulfan concentration range. The obtained biases were ≤10.3%. Both analyzers met the acceptance criteria for sample probe carry-over and dilution integrity. Agreement between the immunoassay and LC-HRMS was high: 92% and 89% of the samples measured on Architect and Cobas, respectively, were within the ±15% limit compared to the corresponding LC-HRMS results. CONCLUSIONS: Overall, good analytical performance and high agreement with LC-HRMS results were obtained for the immunoassay installed on both routine clinical chemistry analyzers. Therefore, this assay could be implemented as a valid alternative for LC methods in clinical laboratories on different open-channel clinical chemistry analyzers, resulting in shorter turn-around times for reporting busulfan TDM results with subsequent faster dosage adjustments.


Asunto(s)
Busulfano , Monitoreo de Drogas , Automatización , Cromatografía Liquida , Monitoreo de Drogas/métodos , Humanos , Inmunoensayo/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...