RESUMEN
INTRODUCTION: arthroscopic surgical treatment of rotator cuff tendon injuries has replaced open surgery as the first treatment option. Different surgical techniques have been described for massive or irreparable ruptures, and recently, a new device that consists of a biodegradable subacromial spacer between the humeral head and the acromion has been used. The present study aims to analyse the results of this implant in our experience. MATERIAL AND METHODS: we conducted an observational and retrospective study of all patients undergoing subacromial spacer implantation at our centre from 2017 to 2019. Patients were assessed pre- and postoperatively using the Constant, DASH and VAS scales. RESULTS: a total of 43 patients met the inclusion criteria and the minimum follow-up of 24 months. The mean DASH scale score went from 53.6 at preoperative assessment to 27.9 at postoperative assessment (p = 0.026). There was also a significant improvement in the Constant scale from a mean of 37.9 to 61.8 (p = 0.037). In terms of pain assessment, the mean VAS went from a mean of 7.44 to 3.38 (p = 0.916). In 90% of patients no complications or need for further interventions were objectified. CONCLUSIONS: the subacromial balloon has shown favorable results in our series of patients, so it could be a valid treatment option in patients with non-repairable rotator cuff tears.
INTRODUCCIÓN: el tratamiento mediante cirugía artroscópica de las lesiones del manguito rotador ha desplazado a la cirugía abierta como primera opción de tratamiento. Existen diferentes técnicas quirúrgicas descritas para tratar las roturas masivas o no reparables. Desde hace unos años se viene utilizando un nuevo dispositivo que consiste en un balón subacromial biodegradable que actúa como espaciador entre la cabeza humeral y el acromion. Este trabajo pretende analizar los resultados de este implante. MATERIAL Y MÉTODOS: realizamos un estudio observacional y retrospectivo de todos los pacientes a los que se les implantó un balón subacromial en nuestro centro entre 2017 y 2019. Se evaluó a los pacientes pre y postoperatoriamente mediante las escalas de Constant, DASH y EVA. RESULTADOS: un total de 43 pacientes cumplieron los criterios de inclusión y el seguimiento mínimo de 24 meses. La puntuación media de la escala DASH pasó de 53.6 en la evaluación preoperatoria a 27.9 en la postoperatoria (p = 0.026). También se obtuvo una mejoría significativa en la escala de Constant, que pasó de una media de 37.9 a 61.8 (p = 0.037). En cuanto a la evaluación del dolor, la EVA media pasó de 7.44 a 3.38 (p = 0.916). En 90% de los pacientes no se objetivaron complicaciones ni necesidad de nuevas intervenciones. CONCLUSIONES: el balón subacromial ha mostrado resultados favorables en nuestra serie de pacientes, por lo que podría suponer una opción válida de tratamiento en pacientes con roturas no reparables del manguito rotador.
Asunto(s)
Lesiones del Manguito de los Rotadores , Humanos , Lesiones del Manguito de los Rotadores/cirugía , Manguito de los Rotadores/cirugía , Estudios Retrospectivos , Artroscopía , Rotura/cirugía , Resultado del Tratamiento , Rango del Movimiento ArticularRESUMEN
Resumen: Introducción: el tratamiento mediante cirugía artroscópica de las lesiones del manguito rotador ha desplazado a la cirugía abierta como primera opción de tratamiento. Existen diferentes técnicas quirúrgicas descritas para tratar las roturas masivas o no reparables. Desde hace unos años se viene utilizando un nuevo dispositivo que consiste en un balón subacromial biodegradable que actúa como espaciador entre la cabeza humeral y el acromion. Este trabajo pretende analizar los resultados de este implante. Material y métodos: realizamos un estudio observacional y retrospectivo de todos los pacientes a los que se les implantó un balón subacromial en nuestro centro entre 2017 y 2019. Se evaluó a los pacientes pre y postoperatoriamente mediante las escalas de Constant, DASH y EVA. Resultados: un total de 43 pacientes cumplieron los criterios de inclusión y el seguimiento mínimo de 24 meses. La puntuación media de la escala DASH pasó de 53.6 en la evaluación preoperatoria a 27.9 en la postoperatoria (p = 0.026). También se obtuvo una mejoría significativa en la escala de Constant, que pasó de una media de 37.9 a 61.8 (p = 0.037). En cuanto a la evaluación del dolor, la EVA media pasó de 7.44 a 3.38 (p = 0.916). En 90% de los pacientes no se objetivaron complicaciones ni necesidad de nuevas intervenciones. Conclusiones: el balón subacromial ha mostrado resultados favorables en nuestra serie de pacientes, por lo que podría suponer una opción válida de tratamiento en pacientes con roturas no reparables del manguito rotador.
Abstract: Introduction: arthroscopic surgical treatment of rotator cuff tendon injuries has replaced open surgery as the first treatment option. Different surgical techniques have been described for massive or irreparable ruptures, and recently, a new device that consists of a biodegradable subacromial spacer between the humeral head and the acromion has been used. The present study aims to analyse the results of this implant in our experience. Material and methods: we conducted an observational and retrospective study of all patients undergoing subacromial spacer implantation at our centre from 2017 to 2019. Patients were assessed pre- and postoperatively using the Constant, DASH and VAS scales. Results: a total of 43 patients met the inclusion criteria and the minimum follow-up of 24 months. The mean DASH scale score went from 53.6 at preoperative assessment to 27.9 at postoperative assessment (p = 0.026). There was also a significant improvement in the Constant scale from a mean of 37.9 to 61.8 (p = 0.037). In terms of pain assessment, the mean VAS went from a mean of 7.44 to 3.38 (p = 0.916). In 90% of patients no complications or need for further interventions were objectified. Conclusions: the subacromial balloon has shown favorable results in our series of patients, so it could be a valid treatment option in patients with non-repairable rotator cuff tears.
RESUMEN
Resumen: Introducción: El estadio final de la artropatía de manguito (AM) genera dolor e invalidez, el tratamiento mediante artroplastía invertida (AI) muestra buenos índices de reducción de dolor y mejoras en movilidad. El objetivo de nuestro trabajo fue evaluar de manera retrospectiva los resultados a mediano plazo de la artroplastía invertida de hombro en nuestro centro. Material y método: Retrospectivamente analizamos 21 pacientes (23 prótesis) sometidos a AI con el diagnóstico de AM. La edad media fue de 75.21 años. El seguimiento mínimo fue de 60 meses. Analizamos las escalas ASES, DASH y CONSTANT preoperatorias y en la última visita de seguimiento. Se analizó la escala VAS preoperatoria y postoperatoria y rango de movilidad preoperatoria y postoperatoria. Resultados: Mejoraron todas las escalas funcionales y dolor (p < 0.001). ASES en 38.91 puntos (IC 95% 30.97-46.84); CONSTANT en 40.89 puntos (IC 95% 34.57-47.21); DASH en 52.65 puntos (IC 95% 46.31-59.0) p < 0.001; y 5.41 puntos (IC 95% 4.31-6.50) en VAS. Mejoraron con significación estadística la flexión (66.52o a 113.91o); y la abducción (63.69o a 105.85o). No obtuvimos significación estadística en rotación externa ni en rotación interna. Aparecieron complicaciones en 14 pacientes; 11 notching glenoideo, una infección crónica, una infección tardía y una fractura intraoperatoria de glenoides. Conclusiones: La AI de hombro representa una alternativa eficaz para el tratamiento de la AM. Puede esperarse alivio del dolor y una mejoría en la flexión y abducción del hombro; la ganancia en rotaciones es poco predecible.
Abstract: Introduction: The final stage of rotator cuff tear arthropathy generates pain and disability, treatment with reverse shoulder arthroplasty shows in different published studies good rates of pain reduction and improvements in mobility. the objective of our study was to retrospectively evaluate the medium-term results of inverted shoulder replacement at our center. Material and methods: Retrospectively, we analyzed 21 patients (23 prosthetics) undergoing reverse shoulder arthroplasty with the diagnosis of rotator cuff tear arthropathy. The average age of patients was 75.21 years The minimum follow-up was 60 months. We analyzed in all preoperative ASES, DASH and CONSTANT patients, and a new functional assessment was made using these same scales at the last follow-up visit. We analyzed pre and postoperative VAS as well as pre and postoperative mobility range. Results: We achieved a statistically significant improvement in all functional scale and pain values (p < 0.001). The ASES scale showed an improvement of 38.91 points (95% CI 30.97-46.84); the 40.89-point CONSTANT scale (95% 34.57-47.21) and the 52.65-point DASH scale (95% 46.31-59.0) p < 0.001. We found an improvement of 5.41 points (95% CI 4.31-6.50) on the VAS scale. We also achieved a statistically significant improvement in flexion values 66.52o to 113.91o degrees; abduction 63.69o to 105.85o degrees at the end of the follow-up. We did not get statistical significance in terms of external rotation but with a tendency to improve in the obtained values; instead in internal rotation we obtained results that showed a tendency to worsen. Complications occurred during follow-up in 14 patients; 11 in relation to notching glenoid, one patient with a chronic infection, one patient with a late infection and one intraoperative fracture of glenoid. Conclusions: Reverse shoulder arthroplasty is an effective treatment of rotator cuff arthropathy. Pain relief and improvement in shoulder flexion and abduction can be expected especially; the gain in rotations is unpredictable.
RESUMEN
INTRODUCTION: the final stage of rotator cuff tear arthropathy generates pain and disability, treatment with reverse shoulder arthroplasty shows in different published studies good rates of pain reduction and improvements in mobility. the objective of our study was to retrospectively evaluate the medium-term results of inverted shoulder replacement at our center. MATERIAL AND METHODS: retrospectively, we analyzed 21 patients (23 prosthetics) undergoing reverse shoulder arthroplasty with the diagnosis of rotator cuff tear arthropathy. The average age of patients was 75.21 years The minimum follow-up was 60 months. We analyzed in all preoperative ASES, DASH and CONSTANT patients, and a new functional assessment was made using these same scales at the last follow-up visit. We analyzed pre and postoperative VAS as well as pre and postoperative mobility range. RESULTS: we achieved a statistically significant improvement in all functional scale and pain values (p < 0.001). The ASES scale showed an improvement of 38.91 points (95% CI 30.97-46.84); the 40.89-point CONSTANT scale (95% 34.57-47.21) and the 52.65-point DASH scale (95% 46.31-59.0) p < 0.001. We found an improvement of 5.41 points (95% CI 4.31-6.50) on the VAS scale. We also achieved a statistically significant improvement in flexion values 66.52o to 113.91o degrees; abduction 63.69o to 105.85o degrees at the end of the follow-up. We did not get statistical significance in terms of external rotation but with a tendency to improve in the obtained values; instead in internal rotation we obtained results that showed a tendency to worsen. Complications occurred during follow-up in 14 patients; 11 in relation to notching glenoid, one patient with a chronic infection, one patient with a late infection and one intraoperative fracture of glenoid. CONCLUSIONS: reverse shoulder arthroplasty is an effective treatment of rotator cuff arthropathy. Pain relief and improvement in shoulder flexion and abduction can be expected especially; the gain in rotations is unpredictable.
INTRODUCCIÓN: el estadio final de la artropatía de manguito (AM) genera dolor e invalidez, el tratamiento mediante artroplastía invertida (AI) muestra buenos índices de reducción de dolor y mejoras en movilidad. El objetivo de nuestro trabajo fue evaluar de manera retrospectiva los resultados a mediano plazo de la artroplastía invertida de hombro en nuestro centro. MATERIAL Y MÉTODO: retrospectivamente analizamos 21 pacientes (23 prótesis) sometidos a AI con el diagnóstico de AM. La edad media fue de 75.21 años. El seguimiento mínimo fue de 60 meses. Analizamos las escalas ASES, DASH y CONSTANT preoperatorias y en la última visita de seguimiento. Se analizó la escala VAS preoperatoria y postoperatoria y rango de movilidad preoperatoria y postoperatoria. RESULTADOS: mejoraron todas las escalas funcionales y dolor (p < 0.001). ASES en 38.91 puntos (IC 95% 30.97-46.84); CONSTANT en 40.89 puntos (IC 95% 34.57-47.21); DASH en 52.65 puntos (IC 95% 46.31-59.0) p < 0.001; y 5.41 puntos (IC 95% 4.31-6.50) en VAS. Mejoraron con significación estadística la flexión (66.52o a 113.91o); y la abducción (63.69o a 105.85o). No obtuvimos significación estadística en rotación externa ni en rotación interna. Aparecieron complicaciones en 14 pacientes; 11 notching glenoideo, una infección crónica, una infección tardía y una fractura intraoperatoria de glenoides. CONCLUSIONES: la AI de hombro representa una alternativa eficaz para el tratamiento de la AM. Puede esperarse alivio del dolor y una mejoría en la flexión y abducción del hombro; la ganancia en rotaciones es poco predecible.
Asunto(s)
Artroplastia de Reemplazo , Artropatía por Desgarro del Manguito de los Rotadores , Anciano , Humanos , Artroplastia de Reemplazo/métodos , Artropatías/complicaciones , Artropatías/cirugía , Dolor/etiología , Estudios Retrospectivos , Artropatía por Desgarro del Manguito de los Rotadores/complicaciones , Artropatía por Desgarro del Manguito de los Rotadores/cirugía , Rango del Movimiento Articular , Evaluación de la Discapacidad , Recuperación de la FunciónRESUMEN
Introducción: El objetivo principal fue comparar la actividad clínico-quirúrgica de nuestro Servicio de Ortopedia y Traumatología antes de la instauración del plan de contingencia frente a la pandemia de la COVID-19 y durante este, un aspecto relevante para establecer antecedentes que permitan guiar nuestro desempeño ante la segunda ola de casos y futuras contingencias semejantes. materiales y métodos: Estudio analítico observacional longitudinal ambispectivo de los pacientes atendidos en el Servicio de Ortopedia y Traumatología de un hospital del sistema público de la Ciudad Autónoma de Buenos Aires, durante el plan de contingencia frente a la pandemia de la COVID-19. Como variable de resultado primaria se valoró el número total de cirugías realizadas durante el período de estudio. Resultados: La pandemia se asoció con menos cirugías totales (p = 0,002), de Guardia (p = 0,000) y de Planta (p = 0,002). Las cirugías totales se redujeron un 81,5%. Las cirugías de urgencia representaron el 97%, diferencia significativa con el período fuera de la pandemia (p = 0,080). Además, el promedio de cirugías por día quirúrgico disponible fue significativamente menor (p = 0,000). Conclusiones: Creemos que la atención de la enfermedad ortopédica y el trauma musculoesquelético, adaptada a las obligaciones indicadas por el plan nacional y regional de contingencia frente a la pandemia, fue notoriamente menor que nuestro desempeño habitual. Si bien respondimos adecuadamente a las urgencias de nuestra especialidad queda pendiente la posibilidad de estratificar y considerar tipos de pacientes con cuadros pasibles de ser tratados, en forma gradual, durante la pandemia. Nivel de Evidencia: IV
Introduction: Our aim was to compare our activity in the Orthopedics and Traumatology service during the first wave of the COVID-19 pandemic. materials and methods: Ambispective longitudinal observational analytical study of patients treated in the Orthopedics and Traumatology Service of a public health hospital of Buenos Aires during the first wave of the COVID-19 pandemic. The primary outcome variable was the total number of surgeries performed during the study period. Results: The pandemic was associated with fewer total surgeries (p = 0.002), emergency department surgeries (p = 0.000) and elective surgeries (p = 0.002). Total surgeries were reduced by 81.5%. Emergency surgeries accounted for 97%, a significant difference with the non-pandemic period (p = 0.080). Additionally, the average number of surgeries per available surgical day was significantly lower (p = 0.000). Conclusions: We believe that, under the regulations indicated by the national and regional pandemic contingency plan, the care of orthopedic pathology and musculoskeletal trauma was notoriously lower than our usual performance. Although we responded adequately to the emergencies of our specialty, the possibility of stratifying and considering types of patients with conditions that could be treated gradually during the pandemic remains pending. Level of Evidence: IV
Asunto(s)
Ortopedia/organización & administración , Ortopedia/estadística & datos numéricos , Pandemias , COVID-19RESUMEN
Introducción: Los sistemas de bloque de corte específicos (BCE) se han presentado como una interesante medida para obtener una correcta alineación en la artroplastía de rodilla, aunque se desconoce cuál de todos los métodos existentes para realizar la planificación es el adecuado. Material y métodos: Se ha diseñado un estudio prospectivo comparando dos sistemas de BCE con planificaciones diferentes (Signature con TAC + teleradiografia; Visionaire con RMN) con el sistema convencional de alineación. Se analizaron parámetros radiográficos, funcionales preoperatorios y postoperatorios, estancia hospitalaria, necesidad de transfusión, tiempo quirúrgico y complicaciones asociadas. Resultados: Un total de 10 pacientes fueron intervenidos por cada grupo. No se observaron diferencias estadísticamente significativas entre los dos sistemas de alineamiento específicos y el sistema convencional (p > 0.05), aunque se objetivó una mayor precisión con estos sistemas, siendo discretamente superior en el sistema Signature. También se observó un menor tiempo quirúrgico en los pacientes intervenidos con los BCE, ligeramente inferior en los intervenidos con el sistema Visionaire (p > 0.05). Conclusiones: Los nuevos sistemas BCE pueden ser útiles para mejorar la alineación en la artroplastía de rodilla así como disminuir el tiempo quirúrgico. A la espera de series mayores que corroboren estos datos, los autores recomiendan estos sistemas en aquellos casos en los que los sistemas convencionales no sean adecuados.
Introduction: Patient-specific cutting blocks (PSCB) have been proposed as an interesting option to achieve appropriate alignment in knee arthroplasty. However, there is no information as to which of the available planning methods is the right one. Material and methods: A prospective study was designed to compare two PSCB systems using different planning methods (Signature with CAT scan + teleradiography; Visionaire with MRI) with the standard alignment method. Radiographic and functional pre- and postoperative parameters were analyzed, together with hospital stay, blood transfusion needs, operative time and associated complications. Results: A total of 10 patients per group were operated on. No statistically significant differences were observed between both of the patient-specific alignment systems and the standard system (p > 0.05). However, greater precision was achieved with the former systems and the Signature system was slightly more accurate. Operative time was shorter in patients in whom PSCBs were used, and it was still slightly shorter in those in whom the Visionaire system was used (p > 0.05). Conclusions: The new PSCB systems may be useful to improve alignment in knee arthroplasty and reduce the operative time. While larger case series confirming these data become available, the authors recommend using these systems in cases in which the standard systems do not work properly.
Asunto(s)
Anciano , Femenino , Humanos , Masculino , Artroplastia de Reemplazo de Rodilla/métodos , Articulación de la Rodilla/cirugía , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos , Artroplastia de Reemplazo de Rodilla/instrumentación , Articulación de la Rodilla/patología , Tiempo de Internación , Tempo Operativo , Estudios Prospectivos , Telerradiología/métodosRESUMEN
INTRODUCTION: Patient-specific cutting blocks (PSCB) have been proposed as an interesting option to achieve appropriate alignment in knee arthroplasty. However, there is no information as to which of the available planning methods is the right one. MATERIAL AND METHODS: A prospective study was designed to compare two, PSCB systems using different planning methods (Signature with CAT scan + teleradiography; Visionaire with MRI) with the standard alignment method. Radiographic and functional pre- and postoperative parameters were analyzed, together with hospital stay, blood transfusion needs, operative time and associated complications. RESULTS: A total of 10 patients per group were operated on. No statistically significant differences were observed between both of the patient-specific alignment systems and the standard system (p > 0.05). However, greater precision was achieved with the former systems and the Signature system was slightly more accurate. Operative time was shorter in patients in whom PSCBs were used, and it was still slightly shorter in those in whom the Visionaire system was used (p > 0.05). CONCLUSIONS: The new PSCB systems may be useful to improve alignment in knee arthroplasty and reduce the operative time. While larger case series confirming these data become available, the authors recommend using these systems in cases in which the standard systems do not work properly.
Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Articulación de la Rodilla/cirugía , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Artroplastia de Reemplazo de Rodilla/instrumentación , Femenino , Humanos , Articulación de la Rodilla/patología , Tiempo de Internación , Masculino , Tempo Operativo , Estudios Prospectivos , Telerradiología/métodosRESUMEN
Se presenta el caso de un adolescente con hipertension arterial grave, en quien clinicamente y por metodos de gabinete se considero que la hipertension era de origen renovascular. La arteriografia renal mostro compresion de la arteria renal derecha por un tumor parapielico. El estudio histologico del mismo revelo que se trataba de un feocromocitoma extraadrenal. El paciente se curo de la hipertension arterial despues de la nefrectomia y extirpacion del tumor