Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Clin Chem Lab Med ; 62(2): 312-321, 2024 Jan 26.
Artículo en Inglés | MEDLINE | ID: mdl-37548423

RESUMEN

OBJECTIVES: Flow cytometry analyses of lymphocyte subpopulations (T, B, NK) are crucial for enhancing clinical algorithms and research workflows. Estimating the total error (TE) values for the percentage and absolute number of lymphocyte subpopulations using the state-of-the-art (SOTA) approach with real data from an external proficiency testing (EPT) scheme was performed. A comparison with previously published Biological Variability (BV)-based specifications was carried out. METHODS: A total of 44,998 results from 86 laboratories over 10 years were analysed and divided into two five-year periods (2012-2016) and (2017-2021). Data come from the IC-1 Lymphocytes scheme of the Spanish External Quality Assurance System (EQAS) GECLID Program. This quantitative scheme includes percentages and absolute numbers of CD3+, CD3+CD4+, CD3+CD8+, CD19+, and CD3-CD56+CD16+ NK cells. The percentage of TE was calculated as: |reported value - robust mean|*100/robust mean for each laboratory and parameter. The cut-off for TE is set at 80 % best results of the laboratories. RESULTS: A significant reduction in the SOTA-based TE for all lymphocyte subpopulations in 2017-2021 was observed compared to 2012-2016. The SOTA-based TE fulfils the minimum BV-based TE for percentages of lymphocyte subpopulations. The parameter with the best analytical performance calculated with SOTA (2017-2021 period)-based TE was the percentage of CD3+ (TE=3.65 %). CONCLUSIONS: The values of SOTA-based specifications from external quality assurance program data are consistent and can be used to develop technical specifications. The technological improvement, quality commitment, standardization, and training, reduce TE. An update of TE every five years is therefore recommended. TE assessment in lymphocyte subsets is a helpful and reliable tool to improve laboratory performance and data-based decision-making trust.


Asunto(s)
Células Asesinas Naturales , Subgrupos Linfocitarios , Humanos , Citometría de Flujo , Recuento de Linfocitos , Ensayos de Aptitud de Laboratorios
2.
J Reprod Immunol ; 154: 103735, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36063657

RESUMEN

Recurrent pregnancy loss (RPL) and recurrent implantation failure (RIF) are two well-defined clinical entities, but the role of the monocytes in their pathophysiology needs to be clarified. This study aimed to evaluate the role of the three monocyte subsets (classical, intermediate, and non-classical) and relevant cytokines/chemokines in a cohort of RPL and RIF women to better characterize a baseline proinflammatory profile that could define inflammatory pathophysiology in these two different conditions. We evaluated 108 non-pregnant women: 53 RPL, 24 RIF, and 31 fertile healthy controls (HC). Multiparametric flow cytometry was used to quantify the frequency of surface chemokine receptors (CCR2, CCR5, and CX3CR1) on the monocyte subsets. Cytokines were assessed in plasma samples using a multiplex assay. The CX3CR1+ and CCR5+ intermediate monocytes were significantly higher in RPL and RIF compared to HC. A significant positive correlation was observed between CX3CR1+ intermediate monocytes and IL-17A (P = .03, r = 0.43). The Boruta algorithm followed by a multivariate logistic regression model was used to select the most relevant variables that could help define RPL and RIF: in RPL were CX3CR1 non-classical monocytes, TGF-ß1, and CCR5 intermediate monocytes; in RIF: CCR5 intermediate monocytes and TGF-ß3. The combination of these variables could predict RPL and RIF with 90 % and 82 %, respectively. Our study suggests that a combination of specific blood monocyte subsets and cytokines could aid in identifying RPL and RIF women with a pro-inflammatory profile. These findings could provide a more integrated understanding of these pathologies. Further investigation and validation in independent cohorts are warranted.


Asunto(s)
Aborto Habitual , Monocitos , Embarazo , Humanos , Femenino , Inmunofenotipificación , Citometría de Flujo , Citocinas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...