Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Interv Neuroradiol ; 29(4): 481-487, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37455501

RESUMEN

Intrasaccular flow disruption is a viable alternative to other endovascular treatments for saccular or wide-necked bifurcation intracranial aneurysms; however, wide neck aneurysms with irregular shapes or shallow depth may not be amenable to treatment currently available intrasaccular devices. Here, we present the first ever case report of the novel Saccular Endovascular Aneurysm Lattice Embolization System (SEAL™). The versatile utility of the SEAL™ device is demonstrated in a patient with acute subarachnoid hemorrhage (SAH) from a ruptured, complex, left middle cerebral artery (MCA) trilobed shallow wide-necked bifurcation aneurysm. Deployment and implantation of the SEAL device were technically feasible, safe, and conformed well to the irregular shape of the complex, ruptured aneurysm. Immediate total aneurysm occlusion was observed after implantation. Importantly, 1-year angiographic follow-up demonstrated durable, complete occlusion with no safety concerns. The SEAL device is a promising new novel technology which has the potential to treat very shallow aneurysms with limited height and irregular, multilobulated aneurysms.


Asunto(s)
Aneurisma Roto , Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Embolización Terapéutica , Procedimientos Endovasculares , Aneurisma Intracraneal , Humanos , Aneurisma Intracraneal/terapia , Aneurisma Intracraneal/cirugía , Estudios de Seguimiento , Resultado del Tratamiento , Aneurisma de la Aorta Abdominal/cirugía , Estudios Retrospectivos , Procedimientos Endovasculares/métodos , Aneurisma Roto/terapia , Aneurisma Roto/cirugía , Embolización Terapéutica/métodos , Angiografía Cerebral
2.
Neuroradiology ; 63(11): 1891-1899, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34031704

RESUMEN

PURPOSE: The Woven EndoBridge (WEB) can be used to treat wide-necked aneurysms without antiplatelet medications, suggesting it may have advantages in the setting of aneurysmal subarachnoid hemorrhage (aSAH). The goal was assessment of safety and efficacy of WEB in aSAH given the delayed nature of aneurysmal thrombosis. METHODS: An international retrospective analysis of patients with aSAH treated with WEB was conducted at 7 tertiary centers from 2016 to 2020. Outcomes included rates of rebleeding, retreatment, complications, and complete occlusion. Furthermore, a systematic review and meta-analysis was conducted from 2011 to 2020 assessing the same outcomes. All pooled event rates were calculated using a random effect model. RESULTS: Consecutive patients with aSAH harbored 25 aneurysms that were treated with 29 WEB devices. The mean age was 53 years, and 65% were female. Zero experienced rebleeding, 2 were retreated, 2 experienced complications, 16 were completely occluded at 3 months, and 21 were completed occluded at 9-12 months. Meta-analysis of 309 WEB treatments for aSAH from 7 case series revealed 2.5% (95% CI 1-5%) had rebleeding, 9% (95% CI 4-17%) were retreated, 17% (95% CI 10-30%) had complications, and 61% (95% CI 51-71%) were completely occluded at 3-6 months. CONCLUSION: WEB embolization in the setting of aSAH provides similar protection against rebleeding with comparable retreatment rates to traditional approaches. However, there is a higher rate of incomplete radiographic occlusion and operative complications compared to WEB embolization of unruptured aneurysms. Long-term prospective studies are needed to fully delineate the role of WEB embolization in aSAH.


Asunto(s)
Aneurisma Roto , Embolización Terapéutica , Procedimientos Endovasculares , Aneurisma Intracraneal , Aneurisma Roto/diagnóstico por imagen , Aneurisma Roto/terapia , Femenino , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/terapia , Persona de Mediana Edad , Estudios Multicéntricos como Asunto , Estudios Retrospectivos , Resultado del Tratamiento
3.
Neuroradiology ; 63(2): 259-266, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32840681

RESUMEN

PURPOSE: We report a multicenter experience using endovascular embolization as the first line approach for treatment of anterior cranial fossa (ACF) dural arteriovenous fistula (DAVF). METHODS: All patients with DAVFs located in the anterior cranial fossa who were treated with endovascular technique as a first line approach were included. Demographics, clinical presentation, angioarchitecture, strategy, complications, immediate angiographic, and follow-up results were included in the analysis. RESULTS: Twenty-three patients met the inclusion criteria (18 male and 5 female). Age ranged from 14 to 79 years (mean 53 years). Twelve patients presented with hemorrhage. Twenty-eight endovascular procedures were performed. The overall immediate angiographic cure rate after endovascular treatment was 82.6% (19/23 patients). The angiographic cure rate of the transvenous strategy was significantly superior to the transarterial strategy (p ≤ 0.001). There was 1 complication in 28 total procedures (3.6%). Angiographic follow-up was available in 21 out of the 23 patients with a mean of 25 months (range 2 to 108 months). In these 21 patients, the DAVF was completely cured in 20 (95%). At last follow-up, all patients had a modified Rankin scale (mRS) 0 to 2. CONCLUSION: Our experience suggests that endovascular treatment for ACF DAVFs has an acceptable safety profile with high rates of complete occlusion, particularly with transvenous approach. Whenever possible, transvenous approach should be preferred over transarterial approach as first line strategy.


Asunto(s)
Malformaciones Vasculares del Sistema Nervioso Central , Embolización Terapéutica , Procedimientos Endovasculares , Adolescente , Adulto , Anciano , Malformaciones Vasculares del Sistema Nervioso Central/diagnóstico por imagen , Malformaciones Vasculares del Sistema Nervioso Central/terapia , Fosa Craneal Anterior , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
4.
Interv Neuroradiol ; 27(2): 230-234, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32967502

RESUMEN

Flow diverter devices have become a routine first-line option for treatment of an increasing population of intracranial aneurysms at many neurovascular centers. Despite the promising results of flow diverter stents on anterior circulation, incomplete occlusion on the presence of fetal posterior circulation has been described on several reports. Here we describe a novel technical alternative to conventional flow diversion approach for this specific subgroup of aneurysms using the low-profile flow diverter, Silk Vista Baby. The device was selectively placed into the fetal type posterior cerebral artery in half-T configuration for the treatment of a posterior communicating aneurysm using a transcirculation approach through the anterior communicating artery. This represents a useful and effective technique and should be considered when encountering the above-described situation.


Asunto(s)
Embolización Terapéutica , Procedimientos Endovasculares , Aneurisma Intracraneal , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/terapia , Estudios Retrospectivos , Stents , Resultado del Tratamiento
5.
Neuroradiology ; 61(9): 1067-1072, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31203413

RESUMEN

PURPOSE: Since appearance of the balloon-remodeling technique and stent-assisted coiling, complex aneurysms have been treated successfully by endovascular means worldwide. Although these two techniques have been widely proven, the combination of both traditionally made the procedures more complicated technically. The aim of our study was to determine the technical success, safety, and efficacy of the low-profile stents delivered through double lumen balloons. METHODS: Clinical, procedural, and angiographic data were analyzed. RESULTS: Eighty-four patients (55 women; age range 20-81 years) harboring 86 aneurysms were included in this study. Aneurysm maximal diameter ranged from 2 to 26 mm, with mean 7.5 mm. There were 62 unruptured, 15 recanalized, and 9 acutely ruptured aneurysms. Aneurysm locations were ACoA (31), MCA (36), supraclinoid ICA (4), carotid bifurcation (2), basilar (7), PCA (3), PICA (2), and VA (1). Ninety-three devices were implanted (63 LVIS jr, 15 LEO Baby, 14 ACCLINO Flex and 1 Neuroform Atlas) through the double lumen balloons (Scepter C or XC and Eclipse 2 L). We found 2 minor clinical events (2.4%) and 1 major event (1.2%). Total intra-procedural technical complication rate was 11.6%. Follow-up was available for 71 patients with an average follow-up of 7 months. Complete and near complete occlusion was 90.1%. Residual aneurysms were seen in 9.9%. CONCLUSION: The "combined remodeling technique" with low-profile stents delivered through double-lumen balloons is technically feasible, safe, and effective for the treatment of intracranial aneurysms. This technique allows the operator to avoid extra maneuvers.


Asunto(s)
Embolización Terapéutica/métodos , Procedimientos Endovasculares/métodos , Aneurisma Intracraneal/terapia , Stents , Adulto , Anciano , Anciano de 80 o más Años , Angiografía Cerebral , Embolización Terapéutica/instrumentación , Procedimientos Endovasculares/instrumentación , Femenino , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
6.
Interv Neuroradiol ; 25(2): 150-156, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30396311

RESUMEN

BACKGROUND: The new generation of flow diverters includes a surface modification with a synthetic biocompatible polymer, which makes the device more biocompatible and less thrombogenic. Optical coherence tomography (OCT) can be used to visualize perforators, stent wall apposition, and intra-stent thrombus. Unfortunately real world application of this technology has been limited because of the limited navigability of these devices in the intracranial vessels. In this report, we share our experience of using 3D-printed neurovascular anatomy models to simulate and test the navigability of a commercially available OCT system and to show the application of this device in a patient treated with the new generation of surface modified flow diverters. MATERIAL AND METHODS: Navigability of OCT catheters was tested in vitro using four different 3D-printed silicone replicas of the intracranial anterior circulation, after the implantation of surface modified devices. Intermediate catheters were used in different tortuous anatomies and positions. After this assessment, we describe the OCT image analysis of a Pipeline Shield for treating an unruptured posterior communicating artery (PCOM) aneurysm. RESULTS: Use of intermediate catheters in the 3D-printed replicas was associated with better navigation of the OCT catheters in favorable anatomies but did not help as much in unfavorable anatomies. OCT image analysis of a PCOM aneurysm treated with Pipeline Embolization Device Shield demonstrated areas of unsatisfactory apposition with no thrombus formation. CONCLUSIONS: OCT improves the understanding of the flow diversion technology. The development of less thrombogenic devices, like the Pipeline Flex with Shield Technology, reinforces the need for intraluminal imaging for neurovascular application.


Asunto(s)
Circulación Cerebrovascular , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/cirugía , Modelos Anatómicos , Impresión Tridimensional , Stents , Tomografía de Coherencia Óptica , Angiografía de Substracción Digital , Materiales Biocompatibles , Humanos , Angiografía por Resonancia Magnética , Masculino , Persona de Mediana Edad , Inhibidores de Agregación Plaquetaria/administración & dosificación , Diseño de Prótesis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...