1.
Respir Med Case Rep ; 47: 101989, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38318225

RESUMEN

Urinothorax is a rare cause of pleural effusion. Infected urinothorax is even rarer. Here we present a case of infected urinothorax from renal mass causing obstructive uropathy. Patient improved with pleural drainage and a multidisciplinary approach of treatment between team involving urologist and pulmonologist. This case highlights the complexity in the diagnosis and management of infected urinothorax.

2.
Int J Surg Pathol ; : 10668969241226703, 2024 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-38291647

RESUMEN

Atrophic kidney-like lesion (AKLL) is a rare kidney lesion, which was recently suggested by the Genitourinary Pathology Society as a provisional entity. As of now, 16 examples of AKLL have been described in the literature. Here we report a new tumor which shows similar clinicopathologic characteristics with those previously reported in AKLL. Immunohistochemical (IHC) studies in the current lesion identified a biphasic staining pattern consisting of a mixture of WT1+/KRT7-/PAX8- large dilated cysts and WT-/KRT7+/PAX8+ small atrophic cysts. Histomorphologic features of AKLL overlap with several neoplastic and non-neoplastic entities which can lead to mischaracterization. Awareness of the differentiating features is likely important when evaluating these lesions.

3.
Int J Surg Pathol ; 32(1): 145-149, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37050851

RESUMEN

Fumarate hydratase deficient renal cell carcinoma (FHRCC) can exhibit a heterogenous immunoprofile. In the present case, a solitary 10.5 cm mixed cystic and solid left kidney tumor showed various growth patterns, involving renal sinus adipose tissue and the renal pelvis. Tumor cells showed prominent nucleoli and perinucleolar halos. Aberrant diffuse (>90%), strong, and membranous carbonic anhydrase 9 and variable GATA3 expression were present. Diagnostic loss of fumarate hydratase expression and 2-succinyl cysteine overexpression (cytoplasmic and nuclear) were identified. Carbonic anhydrase 9 and GATA3 expression in FHRCC is rarely reported in the literature, and may cause misdiagnosis of clear cell RCC and/or urothelial carcinoma.


Asunto(s)
Carcinoma de Células Renales , Carcinoma de Células Transicionales , Neoplasias Renales , Neoplasias de la Vejiga Urinaria , Humanos , Carcinoma de Células Renales/diagnóstico , Carcinoma de Células Renales/patología , Neoplasias Renales/diagnóstico , Neoplasias Renales/patología , Fumarato Hidratasa/genética , Anhidrasa Carbónica IX , Factor de Transcripción GATA3
4.
J Interv Card Electrophysiol ; 8(2): 141-8, 2003 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-12766506

RESUMEN

INTRODUCTION: Atrial fibrillation has been shown to initiate from triggers within pulmonary veins. Several studies have documented that electrical isolation of those triggers can lead to maintenance of sinus rhythm. The complication of pulmonary vein stenosis has limited the utility of delivering ablation energy within the pulmonary vein. We utilize a focused ultrasound catheter ablation system for delivery of transmural ablation lines proximal to the pulmonary vein ostium. METHODS: Nine dogs (weight 30-39 kg) were anesthetized and ventilated. Through a transseptal approach, pulmonary veins were engaged with the focused balloon ultrasound catheter. Ultrasound power was delivered at 40 acoustic watts outside the pulmonary vein ostium, focused 2 mm off the balloon surface, with a depth of approximately 6 mm, for 30-120 seconds. Following ablation, lesions were histopathologically analyzed. RESULTS: Of nine animals studied, fourteen pulmonary veins were ablated. We found successful delivery of near circumferential and transmural ablation lines in 6/14 pulmonary veins. In each of the six circumferential ablations, successful alignment of the ultrasound transducer along the longitudinal axis of the parabolic balloon occurred. The final four ablations were conducted with an enhanced catheter design that assured axial alignment. Of these ablations, all four were circumferential. The remaining 8 pulmonary veins had incomplete delivery of lesions. In each of these veins the ultrasound transducer was misaligned with the balloon axis when therapy was delivered. CONCLUSION: Focused ultrasound ablation is a new means of performing pulmonary vein isolation. This method provides delivery of lesions outside the vein, limiting the risk of pulmonary vein stenosis for the treatment of atrial fibrillation.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Venas Pulmonares , Ultrasonografía Intervencional , Animales , Perros
5.
Oruro; s.n; 1999. 108 p. ilus.
Tesis en Español | LILACS-Express | LIBOCS, LIBOSP | ID: biblio-1322170
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...