Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Diagn Cytopathol ; 52(9): 519-523, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38828711

RESUMEN

Fine-needle aspiration (FNA) is a safe, cost-effective diagnostic procedure used in the evaluation of thyroid nodules. The number of thyroid FNAs has dramatically increased over the past few years. In the absence of standardized procedures regarding the number of needle passes needed for diagnosis and the lack of clarity on the use of conventional smears (CS) versus liquid-based preparations (LBP), the demand of thyroid FNAs has led to increased workload on cytology laboratories, which can negatively affect patient safety. We implemented a standardized two needle passes for CS and collection of all needle rinses and additional pass material in CytoRich Red for ThinPrep LBP and compared the non-diagnostic and diagnostic rates before and after this intervention. There were 290 pre-intervention cases and 348 post-intervention cases; of which, there were 17 (5.9%) non-diagnostic cases of the pre-intervention group and 27 (7.8) non-diagnostic cases of the post-intervention group. There was no statistically significant difference in non-diagnostic and diagnostic rates before and after the change (p = 0.347 by two-tailed Z test).


Asunto(s)
Glándula Tiroides , Nódulo Tiroideo , Humanos , Biopsia con Aguja Fina/métodos , Nódulo Tiroideo/patología , Nódulo Tiroideo/diagnóstico , Glándula Tiroides/patología , Neoplasias de la Tiroides/patología , Neoplasias de la Tiroides/diagnóstico
2.
Arch Pathol Lab Med ; 2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38576208

RESUMEN

CONTEXT.­: Core biopsies are standard of care for diagnosis and surveillance of prostate cancer. Fragmentation makes numeric assessment of cancer challenging and increases risk of inaccurate staging with direct implications on management. OBJECTIVE.­: To determine factors responsible for fragmentation at our institution. DESIGN.­: Prostate core biopsies performed at 2 hospital sites during 1 week were prospectively identified. Biopsies were received in multipart formalin jars, either mounted on a nonadherent dressing pad (Telfa, Medtronic Inc) or freely suspended, and grossed by experienced pathologists' assistants. Fragmentation was defined as the difference between number of cores sent by the clinician and number of cores counted by the pathologist on microscopy. RESULTS.­: Forty-six cases (15 benign; 31 malignant) with 535 specimen jars were identified of which 309 of 535 (57.8%) had >1 biopsy core per jar; 230 of 535 (43%) were received mounted on Telfa and 185 of 535 (34.6%) had histologic evidence of adenocarcinoma. Overall fragmentation rate was 157 of 535 (29.3%). Lowest fragmentation rate was seen when 1 core was submitted per jar regardless of mounting method (31 of 226; 14% for single versus 126 of 309; 41% for >1 per jar; P < .001). For 1 Telfa-mounted core, rate of fragmentation was 5 of 18 (27.8%) versus 26 of 203 (12.8%) when unmounted (P = .24). Significant increase in fragmentation of Telfa-mounted cores was seen when there were 3 per jar (32 of 70; 46% mounted fragmented versus 9 of 47; 19% unmounted fragmented specimens; P = .01). CONCLUSIONS.­: Submission of >1 biopsy core per jar and use of Telfa for mounting are associated with increased fragmentation. We recommend limiting submission to 1 core per jar and avoid mounting on Telfa pads.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA