Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Biofouling ; 40(8): 499-513, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39108059

RESUMEN

The bacterial community from a cooling water system was investigated through culture-dependent and independent strategies, and the responses of planktonic and sessile bacteria (grown in glass slides and stainless-steel coupons) to antimicrobials of industrial and clinical use were assessed. The morphotypes with higher biofilm-forming potential were Pseudoxanthomonas sp., Rheinheimera sp., Aeromonas sp. and Staphylococcus sp., and the first also exhibited lower susceptibility to all antibiotics and biocides tested. 16S rRNA high throughput sequencing indicated that Pseudomonadota (77.1% on average, sd 11.1%), Bacteroidota (8.4, sd 5.7%), and Planctomycetota (3.0, sd 1.3%) were the most abundant phyla. KEGG orthologs associated with antibiotics and biocide resistance were abundant in all samples. Although the minimum inhibitory and bactericidal concentrations were generally higher for biofilms, morphotypes in planktonic form also showed high levels of resistance, which could be associated with biofilm cells passing into the planktonic phase. Overall, monochloramine was the most effective biocide.


Asunto(s)
Bacterias , Biopelículas , Microbiota , Plancton , Biopelículas/efectos de los fármacos , Plancton/efectos de los fármacos , Microbiota/efectos de los fármacos , Bacterias/efectos de los fármacos , Bacterias/clasificación , Bacterias/genética , ARN Ribosómico 16S/genética , Desinfectantes/farmacología , Pruebas de Sensibilidad Microbiana , Antibacterianos/farmacología , Microbiología del Agua
2.
Environ Sci Pollut Res Int ; 22(4): 2945-55, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25226836

RESUMEN

The study was planned to quantify the distribution of bacteria between bulk water and biofilm formed on different materials in an industrial scale cooling tower system of an oil refinery operating with clarified and chlorinated freshwater (CCW) or chlorinated tertiary effluent (TRW) as makeup water. The sessile and planktonic heterotrophic bacteria and Pseudomonas aeruginosa densities were significantly higher in the cooling tower supplied with clarified and chlorinated freshwater (CTCW) (p < 0.05). In the two towers, the biofilm density was higher on the surface of glass slides and stainless steel coupons than on the surface of carbon steel coupons. The average corrosion rates of carbon steel coupons (0.4-0.8 millimeters per year (mpy)) and densities of sessile (12-1.47 × 10(3) colony-forming unit (CFU) cm(-1)) and planktonic (0-2.36 × 10(3) CFU mL(-1)) microbiota remained below of the maximum values of reference used by water treatment companies as indicative of efficient microbial control. These data indicate that the strategies of the water treatment station (WTS) (free chlorine) and industrial wastewater treatment station (IWTS) followed by reverse electrodialysis system (RES) (free chlorine plus chloramine) were effective for the microbiological control of the two makeup water sources.


Asunto(s)
Eliminación de Residuos Líquidos/métodos , Aguas Residuales/microbiología , Carga Bacteriana , Biopelículas , Cloraminas , Cloro , Corrosión , Desinfectantes , Industria Procesadora y de Extracción , Vidrio , Petróleo , Plancton , Reciclaje , Acero Inoxidable , Microbiología del Agua
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA