Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
bioRxiv ; 2023 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-36712079

RESUMEN

Lung cancer in never-smokers disproportionately affects older women. To understand the mutational landscape of this cohort, we performed detailed genome characterization of 73 lung adenocarcinomas from participants of the Women’s Health Initiative (WHI). We find enrichment of EGFR mutations in never-/light-smokers and KRAS mutations in heavy smokers as expected, but we also show that the specific variants of these genes differ by smoking status, with important therapeutic implications. Mutational signature analysis revealed signatures of clock, APOBEC, and DNA repair deficiency in never-/light-smokers; however, the mutational load of these signatures did not differ significantly from those found in smokers. Last, tumors from both smokers and never-/light-smokers shared copy number subtypes, with no significant differences in aneuploidy. Thus, the genomic landscape of lung cancer in never-/light-smokers and smokers is predominantly differentiated by somatic mutations and not copy number alterations.

2.
Anal Chem ; 93(31): 10750-10755, 2021 08 10.
Artículo en Inglés | MEDLINE | ID: mdl-34319086

RESUMEN

Single-cell manipulation, sorting, and dispensing into multiwell plates is useful for single-cell multiomics studies. Here, we develop a single-cell dispenser inspired by electrohydrodynamic jet printing that achieves accurate droplet generation and single-cell sorting and dispensing using fused silica capillary tubing as both the optical detection window and nozzle for droplet dispensing. Parameters that affect droplet dispensing performance-capillary inner and outer diameter, flow rate, applied voltage, and solution properties-were optimized systematically with COMSOL simulations and experimentation. Small (5-10 nL) droplets were obtained by using 100-µm inner diameter and 160-µm outer diameter capillary tubing and allowed efficient encapsulation and dispensing of single cells. We demonstrate an application of this easy-to-assemble single-cell dispenser by sorting and dispensing cells into multiwell plates for single-cell PCR analysis.


Asunto(s)
Dióxido de Silicio , Análisis de la Célula Individual , Separación Celular , Reacción en Cadena de la Polimerasa , Impresión Tridimensional
3.
Anal Chem ; 91(10): 6815-6819, 2019 05 21.
Artículo en Inglés | MEDLINE | ID: mdl-31050286

RESUMEN

The ability to sort and dispense droplets accurately is essential to droplet-based single-cell analysis. Here, we describe a fluorescence-activated single-droplet dispenser (FASD) that is analogous to a conventional fluorescence-activated cell sorter, but sorts droplets containing single cells within an oil emulsion. The FASD system uses cytometric detection and electrohydrodynamic actuation-based single-droplet manipulation, allowing droplet isolation and dispensing with high efficiency and accuracy. The system is compatible with multiwell plates and can be integrated with existing microfluidic devices and large-scale screening systems. By enabling sorting based on single-cell reactions such as PCR, this platform will help expand the basis of cell sorting from mainly protein biomarkers to nucleic acid sequences and secreted biomolecules.


Asunto(s)
Separación Celular/instrumentación , Citometría de Flujo/instrumentación , Análisis de la Célula Individual/instrumentación , Fluorescencia , Humanos , Células K562 , Dispositivos Laboratorio en un Chip
4.
Angew Chem Int Ed Engl ; 57(35): 11378-11383, 2018 08 27.
Artículo en Inglés | MEDLINE | ID: mdl-30003660

RESUMEN

The design and fabrication of a self-digitization dielectrophoretic (SD-DEP) chip with simple components for single-cell manipulation and downstream nucleic acid analysis is presented. The device employed the traditional DEP and insulator DEP to create the local electric field that is tailored to approximately the size of single cells, enabling highly efficient single-cell capture. The multistep procedures of cell manipulation, compartmentalization, lysis, and analysis were performed in the integrated microdevice, consuming minimal reagents, minimizing contamination, decreasing lysate dilution, and increasing assay sensitivity. The platform developed here could be a promising and powerful tool in single-cell research for precise medicine.


Asunto(s)
Dispositivos Laboratorio en un Chip , Ácidos Nucleicos/análisis , Análisis de Secuencia por Matrices de Oligonucleótidos/instrumentación , Análisis de la Célula Individual/instrumentación , Diseño de Equipo , Humanos , Células K562
5.
PLoS One ; 13(5): e0196801, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29718986

RESUMEN

Cancer is a heterogeneous disease, and patient-level genetic assessments can guide therapy choice and impact prognosis. However, little is known about the impact of genetic variability within a tumor, intratumoral heterogeneity (ITH), on disease progression or outcome. Current approaches using bulk tumor specimens can suggest the presence of ITH, but only single-cell genetic methods have the resolution to describe the underlying clonal structures themselves. Current techniques tend to be labor and resource intensive and challenging to characterize with respect to sources of biological and technical variability. We have developed a platform using a microfluidic self-digitization chip to partition cells in stationary volumes for cell imaging and allele-specific PCR. Genotyping data from only confirmed single-cell volumes is obtained and subject to a variety of relevant quality control assessments such as allele dropout, false positive, and false negative rates. We demonstrate single-cell genotyping of the NPM1 type A mutation, an important prognostic indicator in acute myeloid leukemia, on single cells of the cell line OCI-AML3, describing a more complex zygosity distribution than would be predicted via bulk analysis.


Asunto(s)
Técnicas de Genotipaje , Neoplasias/genética , Análisis de Secuencia por Matrices de Oligonucleótidos , Mutación/genética
6.
Blood ; 130(1): 48-58, 2017 07 06.
Artículo en Inglés | MEDLINE | ID: mdl-28490572

RESUMEN

Genomic studies have revealed significant branching heterogeneity in cancer. Studies of resistance to tyrosine kinase inhibitor therapy have not fully reflected this heterogeneity because resistance in individual patients has been ascribed to largely mutually exclusive on-target or off-target mechanisms in which tumors either retain dependency on the target oncogene or subvert it through a parallel pathway. Using targeted sequencing from single cells and colonies from patient samples, we demonstrate tremendous clonal diversity in the majority of acute myeloid leukemia (AML) patients with activating FLT3 internal tandem duplication mutations at the time of acquired resistance to the FLT3 inhibitor quizartinib. These findings establish that clinical resistance to quizartinib is highly complex and reflects the underlying clonal heterogeneity of AML.


Asunto(s)
Benzotiazoles/administración & dosificación , Resistencia a Antineoplásicos , Secuenciación de Nucleótidos de Alto Rendimiento , Mutación INDEL , Leucemia Mieloide Aguda , Compuestos de Fenilurea/administración & dosificación , Tirosina Quinasa 3 Similar a fms/genética , Resistencia a Antineoplásicos/efectos de los fármacos , Resistencia a Antineoplásicos/genética , Femenino , Humanos , Leucemia Mieloide Aguda/tratamiento farmacológico , Leucemia Mieloide Aguda/genética , Masculino
8.
Nat Commun ; 7: 11468, 2016 04 27.
Artículo en Inglés | MEDLINE | ID: mdl-27118210

RESUMEN

The efficient selection and isolation of individual cells of interest from a mixed population is desired in many biomedical and clinical applications. Here we show the concept of using photoswitchable semiconducting polymer dots (Pdots) as an optical 'painting' tool, which enables the selection of certain adherent cells based on their fluorescence, and their spatial and morphological features, under a microscope. We first develop a Pdot that can switch between the bright (ON) and dark (OFF) states reversibly with a 150-fold contrast ratio on irradiation with ultraviolet or red light. With a focused 633-nm laser beam that acts as a 'paintbrush' and the photoswitchable Pdots as the 'paint', we select and 'paint' individual Pdot-labelled adherent cells by turning on their fluorescence, then proceed to sort and recover the optically marked cells (with 90% recovery and near 100% purity), followed by genetic analysis.


Asunto(s)
Fluorescencia , Polímeros/química , Puntos Cuánticos , Semiconductores , Humanos , Células MCF-7 , Microscopía Confocal , Microscopía Fluorescente , Imagen Molecular/métodos
9.
Sci Transl Med ; 7(281): 281re2, 2015 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-25834112

RESUMEN

Clonal evolution in cancer-the selection for and emergence of increasingly malignant clones during progression and therapy, resulting in cancer metastasis and relapse-has been highlighted as an important phenomenon in the biology of leukemia and other cancers. Tracking mutant alleles to determine clonality from diagnosis to relapse or from primary site to metastases in a sensitive and quantitative manner is most often performed using next-generation sequencing. Such methods determine clonal frequencies by extrapolation of allele frequencies in sequencing data of DNA from the metagenome of bulk tumor samples using a set of assumptions. The computational framework that is usually used assumes specific patterns in the order of acquisition of unique mutational events and heterozygosity of mutations in single cells. However, these assumptions are not accurate for all mutant loci in acute myeloid leukemia (AML) samples. To assess whether current models of clonal diversity within individual AML samples are appropriate for common mutations, we developed protocols to directly genotype AML single cells. Single-cell analysis demonstrates that mutations of FLT3 and NPM1 occur in both homozygous and heterozygous states, distributed among at least nine distinct clonal populations in all samples analyzed. There appears to be convergent evolution and differential evolutionary trajectories for cells containing mutations at different loci. This work suggests an underlying tumor heterogeneity beyond what is currently understood in AML, which may be important in the development of therapeutic approaches to eliminate leukemic cell burden and control clonal evolution-induced relapse.


Asunto(s)
Evolución Clonal/genética , Técnicas de Genotipaje/métodos , Leucemia Mieloide Aguda/genética , Leucemia Mieloide Aguda/patología , Análisis de la Célula Individual/métodos , Artefactos , Frecuencia de los Genes/genética , Humanos , Leucemia Mieloide Aguda/diagnóstico , Mutación/genética , Proteínas Nucleares/genética , Nucleofosmina , Recurrencia , Reproducibilidad de los Resultados , Tirosina Quinasa 3 Similar a fms/genética
10.
Anal Chem ; 86(24): 12308-14, 2014 Dec 16.
Artículo en Inglés | MEDLINE | ID: mdl-25390242

RESUMEN

Quantification of mRNA in single cells provides direct insight into how intercellular heterogeneity plays a role in disease progression and outcomes. Quantitative polymerase chain reaction (qPCR), the current gold standard for evaluating gene expression, is insufficient for providing absolute measurement of single-cell mRNA transcript abundance. Challenges include difficulties in handling small sample volumes and the high variability in measurements. Microfluidic digital PCR provides far better sensitivity for minute quantities of genetic material, but the typical format of this assay does not allow for counting of the absolute number of mRNA transcripts samples taken from single cells. Furthermore, a large fraction of the sample is often lost during sample handling in microfluidic digital PCR. Here, we report the absolute quantification of single-cell mRNA transcripts by digital, one-step reverse transcription PCR in a simple microfluidic array device called the self-digitization (SD) chip. By performing the reverse transcription step in digitized volumes, we find that the assay exhibits a linear signal across a wide range of total RNA concentrations and agrees well with standard curve qPCR. The SD chip is found to digitize a high percentage (86.7%) of the sample for single-cell experiments. Moreover, quantification of transferrin receptor mRNA in single cells agrees well with single-molecule fluorescence in situ hybridization experiments. The SD platform for absolute quantification of single-cell mRNA can be optimized for other genes and may be useful as an independent control method for the validation of mRNA quantification techniques.


Asunto(s)
Microfluídica/instrumentación , ARN Mensajero/análisis , Análisis de la Célula Individual , Línea Celular , Reacción en Cadena en Tiempo Real de la Polimerasa , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa
11.
Assay Drug Dev Technol ; 8(5): 591-601, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-20658945

RESUMEN

Microfluidic methods for cellular studies can significantly reduce costs due to reduced reagent and biological specimen requirements compared with many traditional culture techniques. However, current types of readouts are limited and this lack of suitable readouts for microfluidic cultures has significantly hindered the application of microfluidics for cell-based assays. The In-Cell Western (ICW) technique uses quantitative immunocytochemistry and a laser scanner to provide an in situ measure of protein quantities in cells grown in microfluidic channels of arbitrary geometries. The use of ICWs in microfluidic channels was validated by a detailed comparison with current macroscale methods and shown to have excellent correlation. Transforming growth factor-ß-induced epithelial-to-mesenchymal transition of an epithelial cell line was used as an example for further validation of the technique as a readout for soluble-factor-based assays performed in high-throughput microfluidic channels. The use of passive pumping for sample delivery and laser scanning for analysis opens the door to high-throughput quantitative microfluidic cell-based assays that integrate seamlessly with existing high-throughput infrastructure.


Asunto(s)
Ensayos Analíticos de Alto Rendimiento , Inmunoensayo , Técnicas Analíticas Microfluídicas , Anticuerpos/inmunología , Western Blotting , Técnicas de Cultivo de Célula , Línea Celular , Transición Epitelial-Mesenquimal , Humanos , Procesamiento de Imagen Asistido por Computador , Reproducibilidad de los Resultados , Factor de Crecimiento Transformador beta/farmacología
12.
Integr Biol (Camb) ; 1(2): 182-95, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20023802

RESUMEN

Microfluidic devices for cell culture based assays provide new types of engineered microenvironments and new methods for controlling and quantifying cellular responses to these microenvironments. However, without an understanding of the effects of the microenvironments present in microdevices from a cellular perspective, it will be challenging to integrate work done in microdevices with biological data obtained via traditional methods. With the adaptation and validation of In Cell Westerns (ICWs) and in situ analysis techniques to microfluidic devices, we can begin to look at a variety of cellular responses to microcultures. Here we observe several differences in proliferation, glucose metabolism, signaling pathway activation and protein expression levels between cells cultured in traditional macroscale cultures and in microfluidic cultures. The issues of glucose starvation, growth factor restriction, volume density and effects of interactions with poly(dimethylsiloxane) (PDMS) were examined to determine the relative importance of each to cell behavior. Changes in glucose metabolism, insensitivity to volume density or media supplementation, and finally reduced proliferation as the exposure to PDMS increased, suggests that perhaps interactions between media/cells and this commonly employed polymer may be significant for some cell based assays. The differences between cells in macroscale and microfluidic cultures suggest that the cellular baseline may be substantially altered in microcultures due to both inherent differences in scale as well as material differences. The observations highlight the need to biologically validate micofluidic devices for cell based assays in order to accurately interpret the data obtained with them in the context of traditional macroculture data. Additional areas of study that will further characterize and validate microscale culture are discussed.


Asunto(s)
Técnicas de Cultivo de Célula/métodos , Microfluídica/métodos , Animales , Western Blotting/métodos , Técnicas de Cultivo de Célula/instrumentación , División Celular/fisiología , Proliferación Celular/efectos de los fármacos , Dimetilpolisiloxanos/química , Fibroblastos , Inmunohistoquímica/métodos , Ratones , Microfluídica/instrumentación
13.
Bioessays ; 30(9): 811-21, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18693260

RESUMEN

Microscale techniques have been applied to biological assays for nearly two decades, but haven't been widely integrated as common tools in biological laboratories. The significant differences between several physical phenomena at the microscale versus the macroscale have been exploited to provide a variety of new types of assays (such as gradient production or spatial cell patterning). However, the use of these devices by biologists seems to be limited by issues regarding biological validation, ease of use, and the limited available readouts for assays done using microtechnology. Critical validation work has been done recently that highlights the current challenges for microfluidic methods and suggest ways in which future devices might be improved to better integrate with biological assays. With more validation and improved designs, microscale techniques hold immense promise as a platform to study aspects of cell biology that are not possible using current macroscale techniques.


Asunto(s)
Bioensayo , Células , Técnicas Analíticas Microfluídicas , Microfluídica , Miniaturización , Bioensayo/instrumentación , Bioensayo/métodos , Técnicas de Cultivo de Célula , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/métodos , Microfluídica/instrumentación , Microfluídica/métodos , Miniaturización/instrumentación , Miniaturización/métodos , Reproducibilidad de los Resultados
14.
Biomaterials ; 29(23): 3346-56, 2008 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-18486205

RESUMEN

Hydrogels have been commonly used as model systems for 3-dimensional (3-D) cell biology, as they have material properties that resemble natural extracellular matrices (ECMs), and their cell-interactive properties can be readily adapted in order to address a particular hypothesis. Natural and synthetic hydrogels have been used to gain fundamental insights into virtually all aspects of cell behavior, including cell adhesion, migration, and differentiated function. However, cell responses to complex 3-D environments are difficult to adequately explore due to the large number of variables that must be controlled simultaneously. Here we describe an adaptable, automated approach for 3-D cell culture within hydrogel arrays. Our initial results demonstrate that the hydrogel network chemistry (both natural and synthetic), cell type, cell density, cell adhesion ligand density, and degradability within each array spot can be systematically varied to screen for environments that promote cell viability in a 3-D context. In a test-bed application we then demonstrate that a hydrogel array format can be used to identify environments that promote viability of HL-1 cardiomyocytes, a cell line that has not been cultured previously in 3-D hydrogel matrices. Results demonstrate that the fibronectin-derived cell adhesion ligand RGDSP improves HL-1 viability in a dose-dependent manner, and that the effect of RGDSP is particularly pronounced in degrading hydrogel arrays. Importantly, in the presence of 70mum RGDSP, HL-1 cardiomyocyte viability does not decrease even after 7 days of culture in PEG hydrogels. Taken together, our results indicate that the adaptable, array-based format developed in this study may be useful as an enhanced throughput platform for 3-D culture of a variety of cell types.


Asunto(s)
Materiales Biocompatibles , Técnicas de Cultivo de Célula/métodos , Hidrogeles , Animales , Materiales Biocompatibles/química , Adhesión Celular , Recuento de Células , Técnicas de Cultivo de Célula/instrumentación , Línea Celular , Células Cultivadas , Colágeno Tipo I/química , Medios de Cultivo/química , Células Endoteliales/citología , Humanos , Hidrogeles/química , Ensayo de Materiales , Células Madre Mesenquimatosas/citología , Ratones , Miocitos Cardíacos/citología , Células 3T3 NIH , Polietilenglicoles/química
15.
Nat Protoc ; 2(7): 1782-8, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17641645

RESUMEN

We have developed a technique for fabricating microfluidic devices from gelatin using a natural crosslinking process. By producing reusable poly(dimethyl siloxane) molds using standard photolithography, gelatin can be molded into microchannel geometries. The gelatin is crosslinked with the naturally occurring enzyme transglutaminase via a straightforward process that can produce devices suitable for cell culture. The protocol takes approximately 1 day from the start of gelatin preparation to cell seeding. Using these devices, the effects of both the extracellular matrix and soluble factors on cellular behavior and differentiation can be studied in microenvironments that more closely mimic the in vivo environment.


Asunto(s)
Técnicas de Cultivo de Célula/métodos , Gelatina/química , Técnicas Analíticas Microfluídicas/métodos , Fenómenos Fisiológicos Celulares , Reactivos de Enlaces Cruzados , Enzimas , Matriz Extracelular/fisiología , Gelatina/genética , Geles , Expresión Génica , Glutamina/análisis , Microfluídica
16.
Eur J Cancer ; 42(9): 1225-36, 2006 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16697180

RESUMEN

Several groups have proposed that mammary epithelial cell (MEC) populations, in common with other epithelia, have stem and progenitor sub-populations that are long-lived and provide most of the growth potential during ductal (and perhaps lobuloalveolar) outgrowth. In this review, we describe what is known about normal development, particularly with respect to the growth potential and regenerative capacity of mouse MEC populations. We have developed a theoretical model in order to understand how the activity of the somatic stem/progenitor cell compartment during mammary gland development could affect the demographic of adult MEC populations. This demographic is likely to be key to understanding tumour risk, since long-lived cells provide great advantages in the process of cancer development.


Asunto(s)
Células Epiteliales/citología , Glándulas Mamarias Humanas/citología , Células Madre/citología , Animales , División Celular , Femenino , Humanos , Glándulas Mamarias Humanas/crecimiento & desarrollo , Ratones , Modelos Biológicos , Lesiones Precancerosas/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...