Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Phys Med Biol ; 69(14)2024 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-38914107

RESUMEN

Objective.This study aims to design, manufacture, and test 3D printed quality assurance (QA) dosimetry phantoms for synchrotron brain cancer radiation therapy at the Australian synchrotron.Approach.Fabricated 3D printed phantoms from simple slab phantoms, a preclinical rat phantom, and an anthropomorphic head phantom were fabricated and characterized. Attenuation measurements of various polymers, ceramics and metals were acquired using synchrotron monochromatic micro-computed tomography (CT) imaging. Polylactic acid plus, VeroClear, Durable resin, and tricalcium phosphate were used in constructing the phantoms. Furthermore, 3D printed bone equivalent materials were compared relative to ICRU bone and hemihydrate plaster. Homogeneous and heterogeneous rat phantoms were designed and fabricated using tissue-equivalent materials. Geometric accuracy, CT imaging, and consistency were considered. Moreover, synchrotron broad-beam x-rays were delivered using a 3 Tesla superconducting multipole wiggler field for four sets of synchrotron radiation beam qualities. Dose measurements were acquired using a PinPoint ionization chamber and compared relative to a water phantom and a RMI457 Solid Water phantom. Experimental depth doses were compared relative to calculated doses using a Geant4 Monte Carlo simulation.Main results.Polylactic acid (PLA+) shows to have a good match with the attenuation coefficient of ICRU water, while both tricalcium phosphate and hydroxyapatite have good attenuation similarity with ICRU bone cortical. PLA+ material can be used as substitute to RMI457 slabs for reference dosimetry with a maximum difference of 1.84%. Percent depth dose measurement also shows that PLA+ has the best match with water and RMI457 within ±2.2% and ±1.6%, respectively. Overall, PLA+ phantoms match with RMI457 phantoms within ±3%.Significance and conclusion.The fabricated phantoms are excellent tissue equivalent equipment for synchrotron radiation dosimetry QA measurement. Both the rat and the anthropomorphic head phantoms are useful in synchrotron brain cancer radiotherapy dosimetry, experiments, and future clinical translation of synchrotron radiotherapy and imaging.


Asunto(s)
Neoplasias Encefálicas , Fantasmas de Imagen , Impresión Tridimensional , Radiometría , Sincrotrones , Ratas , Animales , Radiometría/instrumentación , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/diagnóstico por imagen , Dosificación Radioterapéutica , Método de Montecarlo , Garantía de la Calidad de Atención de Salud , Diseño de Equipo
2.
Phys Med Biol ; 69(11)2024 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-38718813

RESUMEN

Objective.This study aims to characterize radiological properties of selected additive manufacturing (AM) materials utilizing both material extrusion and vat photopolymerization technologies. Monochromatic synchrotron x-ray images and synchrotron treatment beam dosimetry were acquired at the hutch 3B and 2B of the Australian Synchrotron-Imaging and Medical Beamline.Approach.Eight energies from 30 keV up to 65 keV were used to acquire the attenuation coefficients of the AM materials. Comparison of theoretical, and experimental attenuation data of AM materials and standard solid water for MV linac was performed. Broad-beam dosimetry experiment through attenuated dose measurement and a Geant4 Monte Carlo simulation were done for the studied materials to investigate its attenuation properties specific for a 4 tesla wiggler field with varying synchrotron radiation beam qualities.Main results.Polylactic acid (PLA) plus matches attenuation coefficients of both soft tissue and brain tissue, while acrylonitrile butadiene styrene, Acrylonitrile styrene acrylate, and Draft resin have close equivalence to adipose tissue. Lastly, PLA, co-polyester plus, thermoplastic polyurethane, and White resins are promising substitute materials for breast tissue. For broad-beam experiment and simulation, many of the studied materials were able to simulate RMI457 Solid Water and bolus within ±10% for the three synchrotron beam qualities. These results are useful in fabricating phantoms for synchrotron and other related medical radiation applications such as orthovoltage treatments.Significance and conclusion.These 3D printing materials were studied as potential substitutes for selected tissues such as breast tissue, adipose tissue, soft-tissue, and brain tissue useful in fabricating 3D printed phantoms for synchrotron imaging, therapy, and orthovoltage applications. Fabricating customizable heterogeneous anthropomorphic phantoms (e.g. breast, head, thorax) and pre-clinical animal phantoms (e.g. rodents, canine) for synchrotron imaging and radiotherapy using AM can be done based on the results of this study.


Asunto(s)
Sincrotrones , Australia , Método de Montecarlo , Radioterapia/instrumentación , Radioterapia/métodos , Radiometría/instrumentación , Radiometría/métodos , Humanos
3.
Biomimetics (Basel) ; 8(2)2023 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-37366825

RESUMEN

The production of anthropomorphic phantoms generated from tissue-equivalent materials is challenging but offers an excellent copy of the typical environment encountered in typical patients. High-quality dosimetry measurements and the correlation of the measured dose with the biological effects elicited by it are a prerequisite in preparation of clinical trials with novel radiotherapy approaches. We designed and produced a partial upper arm phantom from tissue-equivalent materials for use in experimental high-dose-rate radiotherapy. The phantom was compared to original patient data using density values and Hounsfield units obtained from CT scans. Dose simulations were conducted for broad-beam irradiation and microbeam radiotherapy (MRT) and compared to values measured in a synchrotron radiation experiment. Finally, we validated the phantom in a pilot experiment with human primary melanoma cells.

4.
Cancers (Basel) ; 15(9)2023 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-37173938

RESUMEN

Microbeam radiotherapy (MRT), a high dose rate radiotherapy technique using spatial dose fractionation at the micrometre range, has shown a high therapeutic efficacy in vivo in different tumour entities, including lung cancer. We have conducted a toxicity study for the spinal cord as organ of risk during irradiation of a target in the thoracic cavity. In young adult rats, the lower thoracic spinal cord was irradiated over a length of 2 cm with an array of quasi-parallel microbeams of 50 µm width, spaced at a centre-to-centre distance of 400 µm, with MRT peak doses up to 800 Gy. No acute or subacute adverse effects were observed within the first week after irradiation up to MRT peak doses of 400 Gy. No significant differences were seen between irradiated animals and non-irradiated controls in motor function and sensitivity, open field test and somatosensory evoked potentials (SSEP). After irradiation with MRT peak doses of 450-800 Gy, dose-dependent neurologic signs occurred. Provided that long-term studies do not reveal significant morbidity due to late toxicity, an MRT dose of 400 Gy can be considered safe for the spinal cord in the tested beam geometry and field size.

5.
Cancers (Basel) ; 15(7)2023 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-37046798

RESUMEN

Microbeam radiation therapy (MRT) utilizes coplanar synchrotron radiation beamlets and is a proposed treatment approach for several tumor diagnoses that currently have poor clinical treatment outcomes, such as gliosarcomas. Monte Carlo (MC) simulations are one of the most used methods at the Imaging and Medical Beamline, Australian Synchrotron to calculate the dose in MRT preclinical studies. The steep dose gradients associated with the 50µm-wide coplanar beamlets present a significant challenge for precise MC simulation of the dose deposition of an MRT irradiation treatment field in a short time frame. The long computation times inhibit the ability to perform dose optimization in treatment planning or apply online image-adaptive radiotherapy techniques to MRT. Much research has been conducted on fast dose estimation methods for clinically available treatments. However, such methods, including GPU Monte Carlo implementations and machine learning (ML) models, are unavailable for novel and emerging cancer radiotherapy options such as MRT. In this work, the successful application of a fast and accurate ML dose prediction model for a preclinical MRT rodent study is presented for the first time. The ML model predicts the peak doses in the path of the microbeams and the valley doses between them, delivered to the tumor target in rat patients. A CT imaging dataset is used to generate digital phantoms for each patient. Augmented variations of the digital phantoms are used to simulate with Geant4 the energy depositions of an MRT beam inside the phantoms with 15% (high-noise) and 2% (low-noise) statistical uncertainty. The high-noise MC simulation data are used to train the ML model to predict the energy depositions in the digital phantoms. The low-noise MC simulations data are used to test the predictive power of the ML model. The predictions of the ML model show an agreement within 3% with low-noise MC simulations for at least 77.6% of all predicted voxels (at least 95.9% of voxels containing tumor) in the case of the valley dose prediction and for at least 93.9% of all predicted voxels (100.0% of voxels containing tumor) in the case of the peak dose prediction. The successful use of high-noise MC simulations for the training, which are much faster to produce, accelerates the production of the training data of the ML model and encourages transfer of the ML model to different treatment modalities for other future applications in novel radiation cancer therapies.

6.
J Synchrotron Radiat ; 29(Pt 4): 1027-1032, 2022 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-35787570

RESUMEN

Microbeam radiotherapy could help to cure malignant tumours which are currently still considered therapy-resistant. With an irradiation target in the thoracic cavity, the heart would be one of the most important organs at risk. To assess the acute adverse effects of microbeam irradiation in the heart, a powerful ex vivo tool was created by combining the Langendorff model of the isolated beating mammalian heart with X-Tream dosimetry. In a first pilot experiment conducted at the Biomedical and Imaging Beamline of the Australian Synchrotron, the system was tested at a microbeam peak dose approximately ten times higher than the anticipated future microbeam irradiation treatment doses. The entire heart was irradiated with a dose of 4000 Gy at a dose rate of >6000 Gy s-1, using an array of 50 µm-wide microbeams spaced at a centre-to-centre distance of 400 µm. Although temporary arrhythmias were seen, they reverted spontaneously to a stable rhythm and no cardiac arrest occurred. This amazing preservation of cardiac function is promising for future therapeutic approaches.


Asunto(s)
Radiometría , Sincrotrones , Animales , Australia , Mamíferos , Radiometría/métodos
7.
Int J Radiat Oncol Biol Phys ; 114(1): 143-152, 2022 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-35533907

RESUMEN

PURPOSE: Microbeam radiation therapy (MRT) has shown several advantages compared with conventional broad-beam radiation therapy in small animal models, including a better preservation of normal tissue function and improved drug delivery based on a rapidly increased vascular permeability in the target region. Normal tissue tolerance is the limiting factor in clinical radiation therapy. Knowledge of the normal tissue tolerance of organs at risk is therefore a prerequisite in evaluating any new radiation therapy approach. With an irradiation target in the thoracic cavity, the heart would be the most important organ at risk. METHODS AND MATERIALS: We used the ex vivo beating rodent heart in the Langendorff perfusion system at the synchrotron to administer microbeam irradiation (MBI) with a peak dose of 40 or 400 Gy. By continuously recording the electrocardiogram, the left ventricular pressure, and the aortic pressure before, during and after MBI, we were able to assess acute and subacute effects of MBI on electrophysiological and mechanical cardiac function. In addition, we analyzed histologic and ultrastructural sequelae caused by MBI. RESULTS: There were no significant changes in heart rate, heart rate variability, systolic increase of left ventricular pressure or aortic pressure. Moreover, the changes of heart rate, left ventricular pressure and aortic pressure by adding 10-5 mol/L norepinephrine to the perfusate, were also not significant between MBI and sham experiments. However, the rate-pressure product as a surrogate marker for maximum workload after MBI was significantly lower compared with sham-irradiated controls. On the structural level, no severe membranous, sarcomeric, mitochondrial or nuclear changes caused by MBI were detected by desmin immunohistochemistry and electron microscopy. CONCLUSIONS: With respect to acute and subacute toxicity, an MBI peak dose up to 400 Gy did not result in severe changes in cardiac electrophysiology or mechanics.


Asunto(s)
Roedores , Sincrotrones , Animales , Corazón , Inmunohistoquímica , Modelos Animales
8.
Med Phys ; 49(5): 3389-3404, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35184310

RESUMEN

PURPOSE: Novel radiotherapy techniques like synchrotron X-ray microbeam radiation therapy (MRT) require fast dose distribution predictions that are accurate at the sub-mm level, especially close to tissue/bone/air interfaces. Monte Carlo (MC) physics simulations are recognized to be one of the most accurate tools to predict the dose delivered in a target tissue but can be very time consuming and therefore prohibitive for treatment planning. Faster dose prediction algorithms are usually developed for clinically deployed treatments only. In this work, we explore a new approach for fast and accurate dose estimations suitable for novel treatments using digital phantoms used in preclinical development and modern machine learning techniques. We develop a generative adversarial network (GAN) model, which is able to emulate the equivalent Geant4 MC simulation with adequate accuracy and use it to predict the radiation dose delivered by a broad synchrotron beam to various phantoms. METHODS: The energy depositions used for the training of the GAN are obtained using full Geant4 MC simulations of a synchrotron radiation broad beam passing through the phantoms. The energy deposition is scored and predicted in voxel matrices of size 140 × 18 × 18 with a voxel edge length of 1 mm. The GAN model consists of two competing 3D convolutional neural networks, which are conditioned on the photon beam and phantom properties. The generator network has a U-Net structure and is designed to predict the energy depositions of the photon beam inside three phantoms of variable geometry with increasing complexity. The critic network is a relatively simple convolutional network, which is trained to distinguish energy depositions predicted by the generator from the ones obtained with the full MC simulation. RESULTS: The energy deposition predictions inside all phantom geometries under investigation show deviations of less than 3% of the maximum deposited energy from the simulation for roughly 99% of the voxels in the field of the beam. Inside the most realistic phantom, a simple pediatric head, the model predictions deviate by less than 1% of the maximal energy deposition from the simulations in more than 96% of the in-field voxels. For all three phantoms, the model generalizes the energy deposition predictions well to phantom geometries, which have not been used for training the model but are interpolations of the training data in multiple dimensions. The computing time for a single prediction is reduced from several hundred hours using Geant4 simulation to less than a second using the GAN model. CONCLUSIONS: The proposed GAN model predicts dose distributions inside unknown phantoms with only small deviations from the full MC simulation with computations times of less than a second. It demonstrates good interpolation ability to unseen but similar phantom geometries and is flexible enough to be trained on data with different radiation scenarios without the need for optimization of the model parameter. This proof-of-concept encourages to apply and further develop the model for the use in MRT treatment planning, which requires fast and accurate predictions with sub-mm resolutions.


Asunto(s)
Algoritmos , Planificación de la Radioterapia Asistida por Computador , Niño , Humanos , Método de Montecarlo , Fantasmas de Imagen , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos
9.
J Synchrotron Radiat ; 29(Pt 1): 125-137, 2022 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-34985430

RESUMEN

Successful transition of synchrotron-based microbeam radiation therapy (MRT) from pre-clinical animal studies to human trials is dependent upon ensuring that there are sufficient and adequate measures in place for quality assurance purposes. Transmission detectors provide researchers and clinicians with a real-time quality assurance and beam-monitoring instrument to ensure safe and accurate dose delivery. In this work, the effect of transmission detectors of different thicknesses (10 and 375 µm) upon the photon energy spectra and dose deposition of spatially fractionated synchrotron radiation is quantified experimentally and by means of a dedicated Geant4 simulation study. The simulation and experimental results confirm that the presence of the 375 µm thick transmission detector results in an approximately 1-6% decrease in broad-beam and microbeam peak dose. The capability to account for the reduction in dose and change to the peak-to-valley dose ratio justifies the use of transmission detectors as thick as 375 µm in MRT provided that treatment planning systems are able to account for their presence. The simulation and experimental results confirm that the presence of the 10 µm thick transmission detector shows a negligible impact (<0.5%) on the photon energy spectra, dose delivery and microbeam structure for both broad-beam and microbeam cases. Whilst the use of 375 µm thick detectors would certainly be appropriate, based upon the idea of best practice the authors recommend that 10 µm thick transmission detectors of this sort be utilized as a real-time quality assurance and beam-monitoring tool during MRT.


Asunto(s)
Silicio , Sincrotrones , Animales , Australia , Humanos , Método de Montecarlo , Dosificación Radioterapéutica
10.
J Synchrotron Radiat ; 28(Pt 5): 1444-1454, 2021 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-34475292

RESUMEN

Spatially fractionated ultra-high-dose-rate beams used during microbeam radiation therapy (MRT) have been shown to increase the differential response between normal and tumour tissue. Quality assurance of MRT requires a dosimeter that possesses tissue equivalence, high radiation tolerance and spatial resolution. This is currently an unsolved challenge. This work explored the use of a 500 nm thick organic semiconductor for MRT dosimetry on the Imaging and Medical Beamline at the Australian Synchrotron. Three beam filters were used to irradiate the device with peak energies of 48, 76 and 88 keV with respective dose rates of 3668, 500 and 209 Gy s-1. The response of the device stabilized to 30% efficiency after an irradiation dose of 30 kGy, with a 0.5% variation at doses of 35 kGy and higher. The calibration factor after pre-irradiation was determined to be 1.02 ±â€…0.005 µGy per count across all three X-ray energy spectra, demonstrating the unique advantage of using tissue-equivalent materials for dosimetry. The percentage depth dose curve was within ±5% of the PTW microDiamond detector. The broad beam was fractionated into 50 microbeams (50 µm FHWM and 400 µm centre-to-centre distance). For each beam filter, the FWHMs of all 50 microbeams were measured to be 51 ±â€…1.4, 53 ±â€…1.4 and 69 ±â€…1.9 µm, for the highest to lowest dose rate, respectively. The variation in response suggested the photodetector possessed dose-rate dependence. However, its ability to reconstruct the microbeam profile was affected by the presence of additional dose peaks adjacent to the one generated by the X-ray microbeam. Geant4 simulations proved that the additional peaks were due to optical photons generated in the barrier film coupled to the sensitive volume. The simulations also confirmed that the amplitude of the additional peak in comparison with the microbeam decreased for spectra with lower peak energies, as observed in the experimental data. The material packaging can be optimized during fabrication by solution processing onto a flexible substrate with a non-fluorescent barrier film. With these improvements, organic photodetectors show promising prospects as a cost-effective high spatial resolution tissue-equivalent flexible dosimeter for synchrotron radiation fields.


Asunto(s)
Radioterapia/instrumentación , Semiconductores , Fraccionamiento de la Dosis de Radiación , Diseño de Equipo , Dosímetros de Radiación , Dosificación Radioterapéutica , Sincrotrones , Rayos X
11.
Sci Rep ; 10(1): 8833, 2020 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-32483249

RESUMEN

Synchrotron facilities produce ultra-high dose rate X-rays that can be used for selective cancer treatment when combined with micron-sized beams. Synchrotron microbeam radiation therapy (MRT) has been shown to inhibit cancer growth in small animals, whilst preserving healthy tissue function. However, the underlying mechanisms that produce successful MRT outcomes are not well understood, either in vitro or in vivo. This study provides new insights into the relationships between dosimetry, radiation transport simulations, in vitro cell response, and pre-clinical brain cancer survival using intracerebral gliosarcoma (9LGS) bearing rats. As part of this ground-breaking research, a new image-guided MRT technique was implemented for accurate tumor targeting combined with a pioneering assessment of tumor dose-coverage; an essential parameter for clinical radiotherapy. Based on the results of our study, we can now (for the first time) present clear and reproducible relationships between the in vitro cell response, tumor dose-volume coverage and survival post MRT irradiation of an aggressive and radioresistant brain cancer in a rodent model. Our innovative and interdisciplinary approach is illustrated by the results of the first long-term MRT pre-clinical trial in Australia. Implementing personalized synchrotron MRT for brain cancer treatment will advance this international research effort towards clinical trials.


Asunto(s)
Neoplasias Encefálicas/radioterapia , Gliosarcoma/radioterapia , Animales , Encéfalo/patología , Encéfalo/efectos de la radiación , Neoplasias Encefálicas/mortalidad , Neoplasias Encefálicas/patología , Modelos Animales de Enfermedad , Gliosarcoma/mortalidad , Gliosarcoma/patología , Masculino , Ratas , Ratas Endogámicas F344 , Tasa de Supervivencia , Sincrotrones , Microtomografía por Rayos X , Rayos X
12.
J Appl Clin Med Phys ; 21(8): 278-288, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32441884

RESUMEN

PURPOSE: The PTW microDiamond has an enhanced spatial resolution when operated in an edge-on orientation but is not typically utilized in this orientation due to the specifications of the IAEA TRS-483 code of practice for small field dosimetry. In this work the suitability of an edge-on orientation and advantages over the recommended face-on orientation will be presented. METHODS: The PTW microDiamond in both orientations was compared on a Varian TrueBeam linac for: machine output factor (OF), percentage depth dose (PDD), and beam profile measurements from 10 × 10 cm2 to a 0.5 × 0.5 cm2 field size for 6X and 6FFF beam energies in a water tank. A quantification of the stem effect was performed in edge-on orientation along with tissue to phantom ratio (TPR) measurements. An extensive angular dependence study for the two orientations was also undertaken within two custom PMMA plastic cylindrical phantoms. RESULTS: The OF of the PTW microDiamond in both orientations agrees within 1% down to the 2 × 2 cm2 field size. The edge-on orientation overresponds in the build-up region but provides improved penumbra and has a maximum observed stem effect of 1%. In the edge-on orientation there is an angular independent response with a maximum of 2% variation down to a 2 × 2 cm2 field. The PTW microDiamond in edge-on orientation for TPR measurements agreed to the CC01 ionization chamber within 1% for all field sizes. CONCLUSIONS: The microDiamond was shown to be suitable for small field dosimetry when operated in edge-on orientation. When edge-on, a significantly reduced angular dependence is observed with no significant stem effect, making it a more versatile QA instrument for rotational delivery techniques.


Asunto(s)
Aceleradores de Partículas , Radiometría , Humanos , Fantasmas de Imagen , Fotones , Agua
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA