Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Rev Sci Instrum ; 93(7): 073303, 2022 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-35922315

RESUMEN

The 300 kV DC high voltage photogun at Jefferson Lab was redesigned to deliver electron beams with a much higher bunch charge and improved beam properties. The original design provided only a modest longitudinal electric field (Ez) at the photocathode, which limited the achievable extracted bunch charge. To reach the bunch charge goal of approximately few nC with 75 ps full-width at half-maximum Gaussian laser pulse width, the existing DC high voltage photogun electrodes and anode-cathode gap were modified to increase Ez at the photocathode. In addition, the anode aperture was spatially shifted with respect to the beamline longitudinal axis to minimize the beam deflection introduced by the non-symmetric nature of the inverted insulator photogun design. We present the electrostatic design of the original photogun and the modified photogun and beam dynamics simulations that predict vastly improved performance. We also quantify the impact of the photocathode recess on beam quality, where recess describes the actual location of the photocathode inside the photogun cathode electrode relative to the intended location. A photocathode unintentionally recessed/misplaced by sub-millimeter distance can significantly impact the downstream beam size.

2.
Rev Sci Instrum ; 89(10): 104703, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30399652

RESUMEN

Nuclear physics experiments performed at the Continuous Electron Beam Accelerator Facility (CEBAF) at the Jefferson Lab require a DC high voltage photogun to generate polarized electron beams from GaAs photocathodes. The photogun uses a tapered ceramic insulator that extends into the vacuum chamber and mechanically holds the cathode electrode. Increasing the operating voltage from nominal -130 kV to -200 kV will provide lower beam emittance, better transmission through injector apertures, and improved photocathode lifetime. This desire to increase the photogun operating voltage led to the design of a triple-point-junction shield electrode which minimizes the electric field at the delicate insulator-metal-vacuum interface and linearizes the potential across the insulator, thus reducing the risk of arcing along the ceramic insulator. This work describes the results obtained using COMSOL® electrostatic-field simulation software and presents the high voltage conditioning results of the upgraded -200 kV CEBAF photogun.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...