Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Front Bioeng Biotechnol ; 12: 1360208, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38576443

RESUMEN

Osseointegrated transfemoral prostheses experience aseptic complications with an incidence between 3% and 30%. The main aseptic risks are implant loosening, adverse bone remodeling, and post-operative periprosthetic fractures. Implant loosening can either be due to a lack of initial (primary) stability of the implant, which hinders bone ingrowth and therefore prevents secondary stability, or, in the long-term, to the progressive resorption of the periprosthetic bone. Post-operative periprosthetic fractures are most often caused by stress concentrations. A method to simultaneously evaluate the primary stability and the load transfer is currently missing. Furthermore, the measurement errors are seldom reported in the literature. In this study a method to reliably quantify the bone implant interaction of osseointegrated transfemoral prostheses in terms of primary stability and load transfer was developed, and its precision was quantified. Micromotions between the prosthesis and the host bone and the strains on the cortical bone were measured on five human cadaveric femurs with a typical commercial osseointegrated implant. To detect the primary stability of the implant and the load transfer, cyclic loads were applied, simulating the peak load during gait. Digital Image Correlation was used to measure displacements and bone strains simultaneously throughout the test. Permanent migrations and inducible micromotions were measured (three translations and three rotations), while, on the same specimen, the full-field strain distribution on the bone surface was measured. The repeatability tests showed that the devised method had an intra-specimen variability smaller than 6 µm for the translation, 0.02 degrees for the rotations, and smaller than 60 microstrain for the strain distribution. The inter-specimen variability was larger than the intra-specimen variability due to the natural differences between femurs. Altogether, the measurement uncertainties (intrinsic measurement errors, intra-specimen repeatability and inter-specimen variability) were smaller than critical levels of biomarkers for adverse remodelling and aseptic loosening, thus allowing to discriminate between stable and unstable implants, and to detect critical strain magnitudes in the host bone. In conclusion, this work showed that it is possible to measure the primary stability and the load transfer of an osseointegrated transfemoral prosthesis in a reliable way using a combination of mechanical testing and DIC.

2.
Bone ; 173: 116814, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37257631

RESUMEN

Spine is the most common site for bone metastases. The evaluation of the mechanical competence and failure location in metastatic vertebrae is a biomechanical and clinical challenge. Little is known about the failure behaviour of vertebrae with metastatic lesions. The aim of this study was to use combined micro-Computed Tomography (microCT) and time-lapsed mechanical testing to reveal the failure location in metastatic vertebrae. Fifteen spine segments, each including a metastatic and a radiologically healthy vertebra, were tested in compression up to failure within a microCT. Volumetric strains were measured using Digital Volume Correlation. The images of undeformed and deformed specimens were overlapped to identify the failure location. Vertebrae with lytic metastases experienced the largest average compressive strains (median ± standard deviation: -8506 ± 4748microstrain), followed by the vertebrae with mixed metastases (-7035 ± 15605microstrain), the radiologically healthy vertebrae (-5743 ± 5697microstrain), and the vertebrae with blastic metastases (-3150 ± 4641microstrain). Strain peaks were localised within and nearby the lytic lesions or around the blastic tissue. Failure between the endplate and the metastasis was identified in vertebrae with lytic metastases, whereas failure localised around the metastasis in vertebrae with blastic lesions. This study showed for the first time the role of metastases on the vertebral internal deformations. While lytic lesions lead to failure of the metastatic vertebra, vertebrae with blastic metastases are more likely to induce failure in the adjacent vertebrae. Nevertheless, every metastatic lesion affects the vertebral deformation differently, making it essential to assess how the lesion affects the bone microstructure. These results suggest that the properties of the lesion (type, size, location within the vertebral body) should be considered when developing clinical tools to predict the risk of fracture in patients with metastatic lesions.


Asunto(s)
Neoplasias Óseas , Fracturas Óseas , Fracturas de la Columna Vertebral , Humanos , Microtomografía por Rayos X , Fracturas de la Columna Vertebral/patología , Columna Vertebral/patología , Neoplasias Óseas/diagnóstico por imagen , Neoplasias Óseas/patología , Fracturas Óseas/patología , Vértebras Lumbares
3.
Front Bioeng Biotechnol ; 11: 1152358, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37008039

RESUMEN

Introduction: Measurement uncertainties of Digital Volume Correlation (DVC) are influenced by several factors, like input images quality, correlation algorithm, bone type, etc. However, it is still unknown if highly heterogeneous trabecular microstructures, typical of lytic and blastic metastases, affect the precision of DVC measurements. Methods: Fifteen metastatic and nine healthy vertebral bodies were scanned twice in zero-strain conditions with a micro-computed tomography (isotropic voxel size = 39 µm). The bone microstructural parameters (Bone Volume Fraction, Structure Thickness, Structure Separation, Structure Number) were calculated. Displacements and strains were evaluated through a global DVC approach (BoneDVC). The relationship between the standard deviation of the error (SDER) and the microstructural parameters was investigated in the entire vertebrae. To evaluate to what extent the measurement uncertainty is influenced by the microstructure, similar relationships were assessed within sub-regions of interest. Results: Higher variability in the SDER was found for metastatic vertebrae compared to the healthy ones (range 91-1030 µÎµ versus 222-599 µÎµ). A weak correlation was found between the SDER and the Structure Separation in metastatic vertebrae and in the sub-regions of interest, highlighting that the heterogenous trabecular microstructure only weakly affects the measurement uncertainties of BoneDVC. No correlation was found for the other microstructural parameters. The spatial distribution of the strain measurement uncertainties seemed to be associated with regions with reduced greyscale gradient variation in the microCT images. Discussion: Measurement uncertainties cannot be taken for granted but need to be assessed in each single application of the DVC to consider the minimum unavoidable measurement uncertainty when interpreting the results.

4.
PLoS One ; 17(9): e0272529, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36084092

RESUMEN

Pathologies such as cancer metastasis and osteoporosis strongly affect the mechanical properties of the vertebral bone and increase the risk of fragility fractures. The prediction of the fracture risk with a patient-specific model, directly generated from the diagnostic images of the patient, could help the clinician in the choice of the correct therapy to follow. But before such models can be used to support any clinical decision, their credibility must be demonstrated through verification, validation, and uncertainty quantification. In this study we describe a procedure for the generation of such patient-specific finite element models and present a first validation of the kinematics of the spine segment. Quantitative computed tomography images of a cadaveric lumbar spine segment presenting vertebral metastatic lesions were used to generate the model. The applied boundary conditions replicated a specific experimental test where the spine segment was loaded in compression-flexion. Model predictions in terms of vertebral surface displacements were compared against the full-field experimental displacements measured with Digital Image Correlation. A good agreement was obtained from the local comparison between experimental data and simulation results (R2 > 0.9 and RMSE% <8%). In conclusion, this work demonstrates the possibility to apply the developed modelling pipeline to predict the displacement field of human spine segment under physiological loading conditions, which is a first fundamental step in the credibility assessment of these clinical decision-support technology.


Asunto(s)
Vértebras Lumbares , Columna Vertebral , Fenómenos Biomecánicos , Simulación por Computador , Análisis de Elementos Finitos , Humanos , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/fisiología , Región Lumbosacra , Columna Vertebral/fisiología
5.
Anal Chem ; 94(29): 10435-10442, 2022 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-35848818

RESUMEN

The need to find a rapid and worthwhile technique for the in situ detection of the content of delta-9-tetrahydrocannabinol (THC) and cannabidiol (CBD) in Cannabis sativa L. is an ever-increasing problem in the forensic field. Among all the techniques for the detection of cannabinoids, Raman spectroscopy can be identified as the most cost-effective, fast, noninvasive, and nondestructive. In this study, 42 different samples were analyzed using Raman spectroscopy with 1064 nm excitation wavelength. The use of an IR wavelength laser showed the possibility to clearly identify THC and CBD in fresh samples, without any further processing, knocking out the contribution of the fluorescence generated by visible and near-IR sources. The results allow assigning all the Raman features in THC- and CBD-rich natural samples. The multivariate analysis underlines the high reproducibility of the spectra and the possibility to distinguish immediately the Raman spectra of the two cannabinoid species. Furthermore, the ratio between the Raman bands at 1295/1440 and 1623/1663 cm-1 is identified as an immediate test parameter to evaluate the THC content in the samples.


Asunto(s)
Cannabidiol , Cannabinoides , Cannabis , Cannabinoides/análisis , Cannabis/química , Dronabinol/análisis , Reproducibilidad de los Resultados , Espectrometría Raman
6.
J Mech Behav Biomed Mater ; 125: 104931, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34736031

RESUMEN

Knowledge of the mechanics and mechanistic reasons inducing rib fracture is fundamental for forensic investigations and for the design of implants and cardiopulmonary resuscitation devices. A mechanical rationale to explain the different rib mechanisms of failure is still a challenge. The aim of this work was to experimentally characterize human ribs to test the hypothesis that a correlation exists between the ribs properties and the mechanism of failure. 89 ribs were tested in antero-posterior compression. The full-field strain distribution was measured through Digital Image Correlation. The fracture load ranged 7-132 N. Two main different mechanisms of failure were observed: brittle and buckling. The strain analysis showed that the direction of principal strains was either aligned with the ribs, or oblique, around 45°, with a rather uniform direction in the most strained area. The maximum principal strains were in the range between 1000 and 30000 microstrain and the minimum principal strain between -30000 and -800 microstrain. The ribs undergoing brittle fracture had significantly thicker cortical bone than those undergoing buckling. Also, larger tensile strains were observed in the specimens with brittle fracture than in the buckling ones. These findings support the focus of cortical thickness modelling which could help in sharpening computational models for the aforesaid purposes.


Asunto(s)
Hueso Cortical , Costillas , Humanos
7.
J Mech Behav Biomed Mater ; 125: 104872, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34655942

RESUMEN

The evaluation of the local mechanical behavior as a result of metastatic lesions is fundamental for the characterization of the mechanical competence of metastatic vertebrae. Micro finite element (microFE) models have the potential of addressing this challenge through laboratory studies but their predictions of local deformation due to the complexity of the bone structure compromized by the lesion must be validated against experiments. In this study, the displacements predicted by homogeneous, linear and isotropic microFE models of vertebrae were validated against experimental Digital Volume Correlation (DVC) measurements. Porcine spine segments, with and without mechanically induced focal lesions, were tested in compression within a micro computed tomography (microCT) scanner. The displacement within the bone were measured with an optimized global DVC approach (BoneDVC). MicroFE models of the intact and lesioned vertebrae, including or excluding the growth plates, were developed from the microCT images. The microFE and DVC boundary conditions were matched. The displacements measured by the DVC and predicted by the microFE along each Cartesian direction were compared. The results showed an excellent agreement between the measured and predicted displacements, both for intact and metastatic vertebrae, in the middle of the vertebra, in those cases where the structure was not loaded beyond yield (0.69 < R2 < 1.00). Models with growth plates showed the worst correlations (0.02 < R2 < 0.99), while a clear improvement was observed if the growth plates were excluded (0.56 < R2 < 1.00). In conclusion, these simplified models can predict complex displacement fields in the elastic regime with high reliability, more complex non-linear models should be implemented to predict regions with high deformation, when the bone is loaded beyond yield.


Asunto(s)
Columna Vertebral , Animales , Reproducibilidad de los Resultados , Columna Vertebral/diagnóstico por imagen , Porcinos , Microtomografía por Rayos X
8.
Front Bioeng Biotechnol ; 9: 756609, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34778229

RESUMEN

The mechanical consequences of osteophytes are not completely clear. We aimed to understand whether and how the presence of an osteophyte perturbs strain distribution in the neighboring bone. The scope of this study was to evaluate the mechanical behavior induced by the osteophytes using full-field surface strain analysis in different loading configurations. Eight thoracolumbar segments, containing a vertebra with an osteophyte and an adjacent vertebra without an osteophyte (control), were harvested from six human spines. The position and size of the osteophytes were evaluated using clinical computed tomography imaging. The spine segments were biomechanically tested in the elastic regime in different loading configurations while the strains over the frontal and lateral surface of vertebral bodies were measured using digital image correlation. The strain fields in the vertebrae with and without osteophytes were compared. The correlation between osteophyte size and strain alteration was explored. The strain fields measured in the vertebrae with osteophytes were different from the control ones. In pure compression, we observed a mild trend between the size of the osteophyte and the strain distribution (R 2 = 0.32, p = 0.15). A slightly stronger trend was found for bending (R 2 = 0.44, p = 0.075). This study suggests that the osteophytes visibly perturb the strain field in the nearby vertebral area. However, the effect on the surrounding bone is not consistent. Indeed, in some cases the osteophyte shielded the neighboring bone, and in other cases, the osteophyte increased the strains.

9.
PLoS One ; 16(6): e0251873, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34061879

RESUMEN

The spine is the first site for incidence of bone metastasis. Thus, the vertebrae have a high potential risk of being weakened by metastatic tissues. The evaluation of strength of the bone affected by the presence of metastases is fundamental to assess the fracture risk. This work proposes a robust method to evaluate the variations of strain distributions due to artificial lesions within the vertebral body, based on in situ mechanical testing and digital volume correlation. Five porcine vertebrae were tested in compression up to 6500N inside a micro computed tomography scanner. For each specimen, images were acquired before and after the application of the load, before and after the introduction of the artificial lesions. Principal strains were computed within the bone by means of digital volume correlation (DVC). All intact specimens showed a consistent strain distribution, with peak minimum principal strain in the range -1.8% to -0.7% in the middle of the vertebra, demonstrating the robustness of the method. Similar distributions of strains were found for the intact vertebrae in the different regions. The artificial lesion generally doubled the strain in the middle portion of the specimen, probably due to stress concentrations close to the defect. In conclusion, a robust method to evaluate the redistribution of the strain due to artificial lesions within the vertebral body was developed and will be used in the future to improve current clinical assessment of fracture risk in metastatic spines.


Asunto(s)
Estrés Mecánico , Cuerpo Vertebral/fisiología , Animales , Fenómenos Biomecánicos , Porcinos , Microtomografía por Rayos X
10.
Bone ; 151: 116028, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34087385

RESUMEN

BACKGROUND: Bone metastases may lead to spine instability and increase the risk of fracture. Scoring systems are available to assess critical metastases, but they lack specificity, and provide uncertain indications over a wide range, where most cases fall. The aim of this work was to use a novel biomechanical approach to evaluate the effect of lesion type, size, and location on the deformation of the metastatic vertebra. METHOD: Vertebrae with metastases were identified from 16 human spines from a donation programme. The size and position of the metastases, and the Spine Instability Neoplastic Score (SINS) were evaluated from clinical Quantitative Computed Tomography images. Thirty-five spine segments consisting of metastatic vertebrae and adjacent healthy controls were biomechanically tested in four different loading conditions. The strain distribution over the entire vertebral bodies was measured with Digital Image Correlation. Correlations between the features of the metastasis (type, size, position and SINS) and the deformation of the metastatic vertebrae were statistically explored. RESULTS: The metastatic type (lytic, blastic, mixed) characterizes the vertebral behaviour (Kruskal-Wallis, p = 0.04). In fact, the lytic metastases showed more critical deformation compared to the control vertebrae (average: 2-fold increase, with peaks of 14-fold increase). By contrast, the vertebrae with mixed or blastic metastases did not show a clear trend, with deformations similar or lower than the controls. Once the position of the lytic lesion with respect to the loading direction was taken into account, the size of the lesion was significantly correlated with the perturbation to the strain distribution (r2 = 0.72, p < 0.001). Conversely, the SINS poorly correlated with the mechanical evidence, and only in case of lytic lesions (r2 = 0.25, p < 0.0001). CONCLUSION: These results highlight the relevance of the size and location of the lytic lesion, which are marginally considered in the current clinical scoring systems, in driving the spinal biomechanical instability. The strong correlation with the biomechanical evidence indicates that these parameters are representative of the mechanical competence of the vertebra. The improved explanatory power compared to the SINS suggests including them in future guidelines for the clinical practice.


Asunto(s)
Neoplasias , Columna Vertebral , Fenómenos Biomecánicos , Humanos , Columna Vertebral/diagnóstico por imagen , Tomografía Computarizada por Rayos X
11.
Sci Rep ; 11(1): 9307, 2021 04 29.
Artículo en Inglés | MEDLINE | ID: mdl-33927313

RESUMEN

Rib fractures represent a common injury type due to blunt chest trauma, affecting hospital stay and mortality especially in elderly patients. Factors promoting rib fragility, however, are little investigated. The purpose of this in vitro study was to explore potential determinants of human rib fragility in the elderly. 89 ribs from 13 human donors (55-99 years) were loaded in antero-posterior compression until fracture using a material testing machine, while surface strains were captured using a digital image correlation system. The effects of age, sex, bone mineral density, rib level and side, four global morphological factors (e.g. rib length), and seven rib cross-sectional morphological factors (e.g. cortical thickness, determined by µCT), on fracture load were statistically examined using Pearson correlation coefficients, Mann-Whitney U test as well as Kruskal-Wallis test with Dunn-Bonferroni post hoc correction. Fracture load showed significant dependencies (p < 0.05) from bone mineral density, age, antero-posterior rib length, cortical thickness, bone volume/tissue volume ratio, trabecular number, trabecular separation, and both cross-sectional area moments of inertia and was significantly higher at rib levels 7 and 8 compared to level 4 (p = 0.001/0.013), whereas side had no significant effect (p = 0.989). Cortical thickness exhibited the highest correlation with fracture load (r = 0.722), followed by the high correlation of fracture load with the area moment of inertia around the longitudinal rib cross-sectional axis (r = 0.687). High correlations with maximum external rib surface strain were detected for bone volume/tissue volume ratio (r = 0.631) and trabecular number (r = 0.648), which both also showed high correlations with the minimum internal rib surface strain (r = - 0.644/ - 0.559). Together with rib level, the determinants cortical thickness, area moment of inertia around the longitudinal rib cross-sectional axis, as well as bone mineral density exhibited the largest effects on human rib fragility with regard to the fracture load. Sex, rib cage side, and global morphology, in contrast, did not affect rib fragility in this study. When checking elderly patients for rib fractures due to blunt chest trauma, patients with low bone mineral density and the mid-thoracic area should be carefully examined.


Asunto(s)
Fracturas de las Costillas/etiología , Costillas/anatomía & histología , Anciano , Anciano de 80 o más Años , Envejecimiento , Fenómenos Biomecánicos , Densidad Ósea , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fracturas de las Costillas/patología , Factores de Riesgo , Caracteres Sexuales
13.
Sci Rep ; 11(1): 3595, 2021 02 11.
Artículo en Inglés | MEDLINE | ID: mdl-33574504

RESUMEN

Pedicle subtraction osteotomy (PSO) is an invasive surgical technique allowing the restoration of a well-balanced sagittal profile, however, the risks of pseudarthrosis and instrumentation breakage are still high. Literature studied primary stability and posterior instrumentation loads, neglecting the load shared by the anterior column, which is fundamental to promote fusion early after surgery. The study aimed at quantifying the load-sharing occurring after PSO procedure across the ventral spinal structures and the posterior instrumentation, as affected by simple bilateral fixation alone, with interbody cages adjacent to PSO level and supplementary accessory rods. Lumbar spine segments were loaded in vitro under flexion-extension, lateral bending, and torsion using an established spine tester. Digital image correlation (DIC) and strain-gauge (SG) analyses measured, respectively, the full-field strain distribution on the ventral surface of the spine and the local strain on posterior primary rods. Ventral strains considerably decreased following PSO and instrumentation, confirming the effectiveness of posterior load-sharing. Supplemental accessory rods considerably reduced the posterior rod strains only with interbody cages, but the ventral strains were unaffected: this indicates that the load transfer across the osteotomy could be promoted, thus explaining the higher fusion rate with decreased rod fracture risk reported in clinical literature.


Asunto(s)
Lordosis/cirugía , Vértebras Lumbares/cirugía , Región Lumbosacra/cirugía , Osteotomía/métodos , Fenómenos Biomecánicos , Biofisica , Femenino , Humanos , Lordosis/patología , Vértebras Lumbares/patología , Región Lumbosacra/patología , Masculino , Persona de Mediana Edad , Tornillos Pediculares , Rango del Movimiento Articular/fisiología , Fusión Vertebral
14.
Ann Biomed Eng ; 49(5): 1380-1390, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33184710

RESUMEN

We hypothesize that variations of body anthropometry, conjointly with the bone strength, determine the risk of hip fracture. To test the hypothesis, we compared, in a simulated sideways fall, the hip impact energy to the energy needed to fracture the femur. Ten femurs from elderly donors were tested using a novel drop-tower protocol for replicating the hip fracture dynamics during a fall on the side. The impact energy was varied for each femur according to the donor's body weight, height and soft-tissue thickness, by adjusting the drop height and mass. The fracture pattern, force, energy, strain in the superior femoral neck, bone morphology and microarchitecture were evaluated. Fracture patterns were consistent with clinically relevant hip fractures, and the superior neck strains and timings were comparable with the literature. The hip impact energy (11 - 95 J) and the fracture energy (11 - 39 J) ranges overlapped and showed comparable variance (CV = 69 and 61%, respectively). The aBMD-based definition of osteoporosis correctly classified 7 (70%) fracture/non-fracture cases. The incorrectly classified cases presented large impact energy variations, morphology variations and large subcortical voids as seen in microcomputed tomography. In conclusion, the risk of osteoporotic hip fracture in a sideways fall depends on both body anthropometry and bone strength.


Asunto(s)
Accidentes por Caídas , Antropometría , Fémur/diagnóstico por imagen , Fracturas de Cadera , Osteoporosis , Anciano , Anciano de 80 o más Años , Densidad Ósea , Femenino , Fémur/fisiología , Humanos , Masculino , Persona de Mediana Edad , Factores de Riesgo , Estrés Mecánico , Microtomografía por Rayos X
15.
Carbohydr Polym ; 251: 116984, 2021 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-33142557

RESUMEN

In this study the multi-scale hierarchical structure of the ß-chitin matrix from squid pen of Loligo vulgaris was used as substrate to synthesize new bio-inspired materials. Aiming to mimic the byssus peculiar mechanical properties, we chemically functionalized the ß-chitin matrix with catechols, one of the main functional groups of the byssus. The obtained matrix preserved its multi-scale structural organization and was able to chelate reversibly Fe(III). Thus, it behaved as the byssus, acting as a metal cross-linkable matrix that upon metalation increased its Young's modulus, E (>10 times). The functionalized matrix was also cross-linked by oxidation provoking an increase of the E (>10 times) and first failure stress (>5 times). The oxidation of the functionalized matrix followed by metalation slightly increased the material mechanical properties. In conclusion, we added specific bio-functionalities in a natural matrix tuning its mechanical properties without altering its multi-scale organization.

16.
Med Eng Phys ; 84: 51-59, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32977922

RESUMEN

Percutaneous Cement Discoplasty has recently been developed to relieve pain in highly degenerated intervertebral discs presenting a vacuum phenomenon in patients that cannot undergo major surgery. Little is currently known about the biomechanical effects of discoplasty. This study aimed at investigating the feasibility of modelling empty discs and subsequent discoplasty surgery and measuring their impact over the specimen geometry and mechanical behaviour. Ten porcine lumbar spine segments were tested in flexion, extension, and lateral bending under 5.4 Nm (with a 200 N compressive force and a 27 mm offset). Tests were performed in three conditions for each specimen: with intact disc, after nucleotomy and after discoplasty. A 3D Digital Image Correlation (DIC) system was used to measure the surface displacements and strains. The posterior disc height, range of motion (ROM), and stiffness were measured at the peak load. CT scans were performed to confirm that the cement distribution was acceptable. Discoplasty recovered the height loss caused by nucleotomy (p = 0.04) with respect to the intact condition, but it did not impact significantly either the ROM or the stiffness. The strains over the disc surface increased after nucleotomy, while discoplasty concentrated the strains on the endplates. In conclusion, this preliminary study has shown that discoplasty recovered the intervertebral posterior height, opening the neuroforamen as clinically observed, but it did not influence the spine mobility or stiffness. This study confirms that this in vitro approach can be used to investigate discoplasty.


Asunto(s)
Degeneración del Disco Intervertebral , Disco Intervertebral , Animales , Fenómenos Biomecánicos , Humanos , Disco Intervertebral/diagnóstico por imagen , Degeneración del Disco Intervertebral/diagnóstico por imagen , Vértebras Lumbares/diagnóstico por imagen , Rango del Movimiento Articular , Porcinos
17.
Materials (Basel) ; 13(15)2020 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-32707909

RESUMEN

Patients spend months between the primary spinal tumor diagnosis and the surgical treatment, due to the need for performing chemotherapy and/or radiotherapy. During this period, they are exposed to an unknown risk of fracture. The aim of this study was to assess if it is possible to measure the mechanical strain in vertebrae affected by primary tumors, so as to open the way to an evidence-based scoring or prediction tool. We performed biomechanical tests on three vertebrae with bone tumor removed from patients. The tests were designed so as not to compromise the standard surgical and diagnostic procedures. Non-destructive mechanical tests in combination with state-of-the-art digital image correlation allowed to measure the distribution of strain on the surface of the vertebra. Our study has shown that the strains in the tumor region is circa 3 times higher than in the healthy bones, with principal strain peaks of 40,000/-20,000 microstrain, indicating a stress concentration potentially triggering vertebral fracture. This study has proven it is possible to analyze the mechanical behavior of primary tumor vertebrae as part of the clinical treatment protocol. This will allow building a tool for quantifying the risk of fracture and improving decision making in spine tumors.

18.
PLoS One ; 15(1): e0227210, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31935225

RESUMEN

The role of the ligaments is fundamental in determining the spine biomechanics in physiological and pathological conditions. The anterior longitudinal ligament (ALL) is fundamental in constraining motions especially in the sagittal plane. The ALL also confines the intervertebral discs, preventing herniation. The specific contribution of the ALL has indirectly been investigated in the past as a part of whole spine segments where the structural flexibility was measured. The mechanical properties of isolated ALL have been measured as well. The strain distribution in the ALL has never been measured under pseudo-physiological conditions, as part of multi-vertebra spine segments. This would help elucidate the biomechanical function of the ALL. The aim of this study was to investigate in depth the biomechanical function of the ALL in front of the lumbar vertebrae and of the intervertebral disc. Five lumbar cadaveric spine specimens were subjected to different loading scenarios (flexion-extension, lateral bending, axial torsion) using a state-of-the-art spine tester. The full-field strain distribution on the anterior surface was measured using digital image correlation (DIC) adapted and validated for application to spine segments. The measured strain maps were highly inhomogeneous: the ALL was generally more strained in front of the discs than in front of the vertebrae, with some locally higher strains both imputable to ligament fibers and related to local bony defects. The strain distributions were significantly different among the loading configurations, but also between opposite directions of loading (flexion vs. extension, right vs. left lateral bending, clockwise vs. counterclockwise torsion). This study allowed for the first time to assess the biomechanical behaviour of the anterior longitudinal ligament for the different loading of the spine. We were able to identify both the average trends, and the local effects related to osteophytes, a key feature indicative of spine degeneration.


Asunto(s)
Disco Intervertebral/fisiología , Ligamentos Longitudinales/fisiología , Vértebras Lumbares/fisiología , Anciano , Fenómenos Biomecánicos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estrés Mecánico
19.
Materials (Basel) ; 13(2)2020 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-31947653

RESUMEN

While the non-linear behavior of spine segments has been extensively investigated in the past, the behavior of the Anterior Longitudinal Ligament (ALL) and its contribution during flexion and extension has never been studied considering the spine as a whole. The aims of the present study were to exploit Digital Image Correlation (DIC) to: (I) characterize the strain distribution on the ALL during flexion-extension, (II) compare the strain on specific regions of interest (ROI) of the ALL in front of the vertebra and of the intervertebral disc, (III) analyze the non-linear relationship between the surface strain and the imposed rotation and the resultant moment. Three specimens consisting of 6 functional spinal units (FSUs) were tested in flexion-extension. The full-field strain maps were measured on the surface of the ALL, and the most strained areas were investigated in detail. The DIC-measured strains showed different values of peak strain in correspondence with the vertebra and the disc but the average over the ROIs was of the same order of magnitude. The strain-moment curves showed a non-linear response like the moment-angle curves: in flexion the slope of the strain-moment curve was greater than in extension and with a more abrupt change of slope. To the authors' knowledge, this is the first study addressing, by means of a full-field strain measurement, the non-linear contribution of the ALL to spine biomechanics. This study was limited to only three specimens; hence the results must be taken with caution. This information could be used in the future to build more realistic numerical models of the spine.

20.
J Biomech Eng ; 140(11)2018 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-30029268

RESUMEN

Metastatic lesions of the vertebra are associated with risk of fracture, which can be disabling and life-threatening. In the literature, attempts are found to identify the parameters that reduce the strength of a metastatic vertebra leading to spine instability. However, a number of controversial issues remain. Our aim was to quantify how the strain distribution in the vertebral body is affected by the presence and by the size of a simulated metastatic defect. Five cadaveric thoracic spine segments were subjected to non-destructive presso-flexion while intact, and after simulation of metastases of increasing size. For the largest defect, the specimens were eventually tested to failure. The full-field strain distribution in the elastic range was measured with digital image correlation (DIC) on the anterior surface of the vertebral body. The mean strain in the vertebra remained similar to the intact when the defects were smaller than 30% of the vertebral volume. The mean strains became significantly larger than in the intact for larger defects. The map of strain and its statistical distribution indicated a rather uniform condition in the intact vertebra and with defects smaller than 30%. Conversely, the strain distribution became significantly different from the intact for defects larger than 30%. A strain peak appeared in the region of the simulated metastasis, where fracture initiated during the final destructive test. This is a first step in understanding how the features of metastasis influence the vertebral strain and for the construction of a mechanistic model to predicted fracture.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...