Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Ophthalmology ; 123(5): 974-83, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26896122

RESUMEN

PURPOSE: To compare the results of corneal collagen cross-linking (CXL) alone with combined simultaneous topography-guided photorefractive keratectomy plus CXL (tPRK-CXL) for progressive keratoconus for a 3-year interval. DESIGN: Prospective, comparative interventional case series. PARTICIPANTS: Forty-eight patients (60 eyes) with progressive keratoconus. METHODS: Thirty eyes underwent combined tPRK with a solid-state laser (maximum ablation depth, 50 µm) followed by CXL, and 30 eyes underwent CXL alone. Groups were matched in terms of age and keratoconus stage. MAIN OUTCOME MEASURES: Corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA), keratometry, and corneal confocal microscopy. RESULTS: Mean follow up was 39±11 months. Mean age at operation was 28±5.82 years. Before surgery, average CDVA in the tPRK-CXL group was 0.26±0.17 logarithm of the minimum angle of resolution (logMAR), and in the CXL group was 0.24±0.18 logMAR (P = 0.58). At last follow-up, CDVA was 0.09±0.10 logMAR in the tPRK-CXL group and 0.15±0.12 logMAR in the CXL group (P < 0.05). In both groups, no patient lost more than 2 lines of Snellen visual acuity, whereas 19 eyes and 8 eyes in the tPRK-CXL group and in the CXL group, respectively, gained 2 or more lines of CDVA. Before surgery, average UDVA was 0.83±0.54 logMAR in the tPRK-CXL group and 0.86±0.62 logMAR in the CXL group (P = 0.79). At last follow-up, UDVA was 0.27±0.25 logMAR in the tPRK-CXL group and 0.69±0.58 logMAR in the CXL group (P < 0.001). Before surgery, steep and flat keratometry had no significant differences between groups, and at last follow-up, both steep and flat keratometry readings were significantly flatter in the tPRK-CXL group compared with the CXL group. Depth of CXL treatment, as evaluated by confocal microscopy, was 269.8±31.8 µm in the CXL group and 299.7±29.8 µm in the tPRK-CXL group (P < 0.001). No differences were found in endothelial cell density. CONCLUSIONS: Simultaneous tPRK followed by CXL in this series of keratoconus patients offered significantly improved vision to treated patients in comparison with CXL alone, and similar results regarding postoperative stability. Safety concerns regarding corneal thickness were taken into account in treatment planning.


Asunto(s)
Topografía de la Córnea , Reactivos de Enlaces Cruzados , Queratocono/terapia , Láseres de Excímeros/uso terapéutico , Fotoquimioterapia , Queratectomía Fotorrefractiva/métodos , Adolescente , Adulto , Colágeno/metabolismo , Terapia Combinada , Sustancia Propia/metabolismo , Femenino , Estudios de Seguimiento , Humanos , Queratocono/tratamiento farmacológico , Queratocono/metabolismo , Queratocono/cirugía , Masculino , Microscopía Confocal , Fármacos Fotosensibilizantes/uso terapéutico , Estudios Prospectivos , Riboflavina/uso terapéutico , Rayos Ultravioleta , Agudeza Visual/fisiología , Adulto Joven
2.
Semin Ophthalmol ; 30(4): 243-51, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24168096

RESUMEN

PURPOSE: To review the current literature on in vivo confocal microscopy anterior segment applications (cornea, conjunctiva, and glaucoma) and discuss its advantages in different pathological conditions. METHODS: Review of selected relevant literature on in vivo confocal microscopy and its different applications. RESULTS: In vivo confocal microscopy can be used to visualize most layers of the cornea and conjunctiva, providing excellent resolution. In the past, it was mainly utilized as a research tool; lately there seems to be an increasing interest for clinical applications; confocal microscopy aids the diagnosis and follow-up of many anterior segment disorders, such as corneal dystrophies, corneal and conjunctival inflammatory and neoplastic diseases, glaucoma patients, and assessment of surgical procedures. CONCLUSION: In vivo confocal microscopy is an important addition to the ophthalmic diagnostic tools with several anterior segment applications. Its clinical applications are being continuously explored and are quickly expanding to cover many new pathological aspects.


Asunto(s)
Segmento Anterior del Ojo/patología , Técnicas de Diagnóstico Oftalmológico , Oftalmopatías/diagnóstico , Microscopía Confocal/métodos , Humanos
3.
Eye Contact Lens ; 40(2): e8-e12, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23392298

RESUMEN

PURPOSE: To present corneal confocal microscopy (CCM) findings in a series of patients with pre-Descemet corneal dystrophy (PDCD). METHODS: A 28-year-old man, a 50-year-old man, a 30-year-old woman, and a 31-year-old man were clinically diagnosed with PDCD on slit lamp microscopic evaluation. All patients were evaluated by means of CCM. The parents of the patients were clinically evaluated. Two of the patients underwent photorefractive keratectomy. RESULTS: In all the patients, CCM revealed highly reflective stromal particles and pleomorphic structures that included particles in the deep stroma, immediately anterior to the Descemet membrane extending up to 60 µm from endothelium. No evidence of PDCD was observed clinically in the parents of the patients. Postoperative course of photorefractive keratectomy was uneventful for both of the patients. CONCLUSIONS: With the use of CCM, a specific pattern of findings seemed to be related with PDCD in this series of sporadic cases.


Asunto(s)
Distrofias Hereditarias de la Córnea/diagnóstico , Lámina Limitante Posterior/patología , Adulto , Distrofias Hereditarias de la Córnea/patología , Femenino , Humanos , Masculino , Microscopía Confocal , Persona de Mediana Edad
4.
Invest Ophthalmol Vis Sci ; 51(10): 5030-3, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-20463316

RESUMEN

PURPOSE: To report the development of posterior linear stromal haze after simultaneous photorefractive keratectomy (PRK) followed by corneal collagen cross-linking (CXL). METHODS: Combined simultaneous customized PRK followed by corneal collagen cross-linking was performed in 23 patients (28 eyes) with keratoconus. Corneas were examined biomicroscopically and by means of confocal microscopy before surgery and 1, 3, 6, 9, and 12 months after surgery. RESULTS: Posterior linear stromal haze was observed clinically (slit lamp biomicroscopy) one month after surgery in 13 of 28 eyes (46.42%). No corneal edema or anterior haze formation was evident. Confocal microscopy revealed in those 13 eyes a hyperreflective area at the level of the posterior stroma 1 month after combined treatment. Both slit lamp examination and corneal confocal microscopy follow-up demonstrated a gradual anterior movement and a decrease in reflectance of this finding. At 12 months this posterior linear stromal haze, despite its anterior movement and decreased density, did not completely disappear at slit lamp and confocal microscopy analysis. CONCLUSIONS: Posterior linear stromal haze formation may appear after simultaneous PRK followed by CXL in patients with keratoconus. This finding seems to gradually become less dense and slowly moves toward the anterior stroma.


Asunto(s)
Opacidad de la Córnea/etiología , Sustancia Propia/patología , Queratocono/terapia , Fotoquimioterapia , Queratectomía Fotorrefractiva , Fármacos Fotosensibilizantes/uso terapéutico , Complicaciones Posoperatorias , Adulto , Colágeno/metabolismo , Terapia Combinada , Opacidad de la Córnea/diagnóstico , Sustancia Propia/metabolismo , Topografía de la Córnea , Reactivos de Enlaces Cruzados , Femenino , Humanos , Queratocono/tratamiento farmacológico , Queratocono/cirugía , Láseres de Excímeros/uso terapéutico , Masculino , Microscopía Confocal , Rayos Ultravioleta , Adulto Joven
5.
Ophthalmic Surg Lasers Imaging ; : 1-5, 2010 Mar 09.
Artículo en Inglés | MEDLINE | ID: mdl-20337306

RESUMEN

In this case series, five patients (10 eyes) underwent laser in siter keratomileusis (LASIK) for the correction of moderate myopia and astigmatism with the Schwind Carriazo Pendular microkeratome 90 mum head. Flap (superior hinged) thickness measured intraoperatively was assessed less than 70 mum in all eyes. On first month's postoperative examination, subepithelial mild corneal haze with consequent myopic regression was found in all patients. A significant improvement of haze formation and residual refractive error were observed during the following postoperative months. In conclusion, post-LASIK subepithelial corneal haze after thin flap creation is a temporarily potential complication that could affect patient's refractive error during the first postoperative month.

6.
Open Ophthalmol J ; 3: 77-81, 2009 Dec 08.
Artículo en Inglés | MEDLINE | ID: mdl-20087439

RESUMEN

PURPOSE: To present a case of nine- year bilateral Intacs (Addition Technology, Inc, Fremont, California, USA) implantation for early stage keratoconus. METHODS: A 25-year-old male underwent bilateral Intacs implantation for the management of keratoconus and hardcontact-lens intolerance (stage 1) in 1999. RESULTS: Nine years postoperatively, spherical equivalent refraction changed from preoperative -0.75 and -2.25 to +0.75 and -1.25 for the right and the left eye, respectively. UCVA was improved from 20/50 to 20/25 in the right and from 20/200 to 20/32 in the left eye. BSCVA of 20/20 in the right eye maintained stable in comparison with the Pre-Intacs BSCVA, while BSCVA was improved from 20/25 to 20/20 in the fellow eye. No early or late complications were observed. CONCLUSIONS: Nine years after bilateral Intacs implantation for the management of early stage keratoconus, there was a significant improvement and postoperative stability in patient's visual acuity. No long-term, sight-threatening complications were identified during follow-up.

8.
J Cataract Refract Surg ; 33(12): 2135-7, 2007 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-18053917

RESUMEN

A 27-year-old man presented with corneal ectasia in his left eye 4 years after myopic laser in situ keratomileusis (LASIK) and was treated with riboflavin-ultraviolet-A (crosslinking). During the first post-treatment days, diffuse lamellar keratitis (DLK) (stage III) developed. The microbiology culture was negative. After intensive treatment with topical corticosteroids, the DLK resolved during the following 2 weeks. Crosslinking for post-LASIK corneal ectasia may induce DLK. Early diagnosis and appropriate treatment with intensive topical corticosteroids is essential to successfully manage this post-crosslinking complication.


Asunto(s)
Colágeno/metabolismo , Enfermedades de la Córnea/tratamiento farmacológico , Queratitis/etiología , Queratomileusis por Láser In Situ/efectos adversos , Fármacos Fotosensibilizantes/efectos adversos , Adulto , Enfermedades de la Córnea/etiología , Enfermedades de la Córnea/metabolismo , Dexametasona/uso terapéutico , Dilatación Patológica/tratamiento farmacológico , Dilatación Patológica/etiología , Dilatación Patológica/metabolismo , Glucocorticoides/uso terapéutico , Humanos , Queratitis/tratamiento farmacológico , Masculino , Miopía/cirugía , Riboflavina/efectos adversos , Rayos Ultravioleta
9.
J Refract Surg ; 23(9): 935-7, 2007 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-18041249

RESUMEN

PURPOSE: To compare the long-term results (9 years) of LASIK in one eye and phakic intraocular lens (implantable contact lens [ICL]) implantation in the fellow eye of the same patient. METHODS: A patient with high myopia underwent LASIK with a MEL 60 excimer laser in one eye (spherical equivalent refraction -9.75 diopters [D], 5-mm optical zone with no transition zone) and phakic intraocular lens (STAAR Collamer implantable contact lens [ICL]) implantation (spherical equivalent refraction -9.50 D) in the fellow eye. RESULTS: At 9 years postoperatively, the mean spherical equivalent refraction was -1.00 in the eye with the ICL and -1.75 D in the eye that underwent LASIK. During the first 6 postoperative months in the LASIK eye, refraction regressed, but remained stable during the remainder of follow-up. Uncorrected visual acuity was 20/25 in the eye with the ICL and 20/30 in the LASIK eye, whereas best spectacle-corrected visual acuity was 20/20 in both eyes. Less night vision problems (glare and halos) were experienced in the eye with the ICL compared to the LASIK eye. Although the patient initially preferred the LASIK procedure, at last follow-up 9 years postoperatively, increased overall satisfaction was reported for the eye with the ICL compared to the LASIK eye. CONCLUSIONS: Nine years after treatment of high myopia with the ICL and LASIK in the same patient, better quality of vision, stability, and satisfaction score were achieved in the eye with the ICL compared to the eye that had undergone LASIK. No long-term sight-threatening complications were found during followup.


Asunto(s)
Queratomileusis por Láser In Situ , Implantación de Lentes Intraoculares , Miopía/cirugía , Lentes Intraoculares Fáquicas , Adulto , Anteojos , Femenino , Estudios de Seguimiento , Humanos , Queratomileusis por Láser In Situ/normas , Implantación de Lentes Intraoculares/normas , Miopía/fisiopatología , Miopía/rehabilitación , Satisfacción del Paciente , Lentes Intraoculares Fáquicas/normas , Ensayos Clínicos Controlados Aleatorios como Asunto , Índice de Severidad de la Enfermedad , Agudeza Visual
10.
J Refract Surg ; 23(9): 937-40, 2007 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-18041250

RESUMEN

PURPOSE: To present 15-year follow-up of one of the first LASIK-treated patients. METHODS: A 40-year-old woman underwent LASIK in the left eye for myopia in July 1991. RESULTS: Fifteen years after LASIK, spherical equivalent error was statistically significantly reduced from preoperative -8.75 -3.75 x 025 degrees to postoperative -4.25 -2.75 x 010 degrees. Six months postoperatively, refractive and topographic stability was obtained and remained stable during follow-up with no significant changes between interval mean time (-3.75 -3.00 x 020 degrees 6 months postoperatively to -4.25 -2.75 x 010 degrees 15 years postoperatively). No early or late postoperative complications were observed, and confocal microscopy revealed a regenerated nerve plexus and normal cornea. However, increased scattering and presence of debris were observed at the flap interface even after 15 years. Despite moderate predictability (residual refractive error) and small optical zone, the patient was satisfied with final outcome. CONCLUSIONS: One of the first LASIK-treated patients was presented 15 years after surgery. LASIK in this patient had low predictability, although refractive and topographic stability occurred after the sixth postoperative month. No long-term, sight-threatening complications were identified during follow-up.


Asunto(s)
Queratomileusis por Láser In Situ , Miopía/cirugía , Adulto , Córnea/inervación , Córnea/patología , Topografía de la Córnea , Anteojos , Femenino , Estudios de Seguimiento , Humanos , Láseres de Excímeros , Microscopía Confocal , Miopía/fisiopatología , Miopía/rehabilitación , Regeneración Nerviosa , Sistema Nervioso/patología , Sistema Nervioso/fisiopatología , Satisfacción del Paciente , Periodo Posoperatorio , Refracción Ocular , Colgajos Quirúrgicos , Agudeza Visual
11.
J Cataract Refract Surg ; 33(11): 1866-70, 2007 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17964390

RESUMEN

PURPOSE: To evaluate whether photorefractive keratectomy (PRK) for moderate myopia using a solid-state laser with a wavelength of 213 nm alters the corneal endothelial cell density. SETTING: University refractive surgery center. METHODS: The corneal endothelium was analyzed preoperatively and 1, 6, and 12 months postoperatively using corneal confocal microscopy (modified HRT II with a Rostock Cornea Module, Heidelberg Engineering) in 60 eyes (30 patients). Patients were randomized to have myopic PRK using a 213 nm wavelength solid-state laser (study group) or a conventional 193 nm wavelength excimer laser (control group). Three endothelial images were acquired in each of 30 preoperative normal eyes to evaluate the repeatability of endothelial cell density measurements. Repeated-measures analysis of variance was used to compare the variations in endothelial cell density between the 2 lasers and the changes in endothelial cell density over time. RESULTS: There were no statistically significant differences in sex, age, corneal pachymetry, attempted correction, preoperative endothelial cell density, or postoperative refractive outcomes (uncorrected visual acuity, best spectacle-corrected visual acuity, and spherical equivalent refraction) between the 2 groups (P>.05). The coefficient of repeatability of endothelial cell density was 131 cells/mm(2). The measured endothelial cell count per 1.0 mm(2) did not significantly change up to 1 year postoperatively in either group (both P>.05). No statistically significant difference was found between the 2 groups in any postoperative interval (P>.05). CONCLUSION: Photorefractive keratectomy for moderate myopia using a 213 nm wavelength solid-state laser or a conventional 193 nm wavelength excimer laser did not significantly affect corneal endothelial density during the 1-year postoperative period.


Asunto(s)
Endotelio Corneal/patología , Láseres de Excímeros , Láseres de Estado Sólido , Miopía/cirugía , Queratectomía Fotorrefractiva , Adolescente , Adulto , Recuento de Células , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
12.
J Cataract Refract Surg ; 33(11): 1982-4, 2007 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17964410

RESUMEN

A 21-year-old woman had crosslinking for keratoconus in the right eye; the left eye was scheduled for penetrating keratoplasty. Five days postoperatively, she presented with geographic epithelial keratitis and iritis. Analysis of tear samples by polymerase chain reaction confirmed the diagnosis. The patient was treated with oral steroids and acyclovir, with significant improvement. Two months postoperatively, the visual acuity was improved and there was no evidence of herpetic disease recurrence. Crosslinking can induce herpetic keratitis with iritis even in patients with no history of herpetic disease. Early diagnosis and proper treatment are essential for a favorable outcome.


Asunto(s)
Iritis/virología , Queratitis Herpética/virología , Queratocono/tratamiento farmacológico , Fármacos Fotosensibilizantes/efectos adversos , Riboflavina/efectos adversos , Rayos Ultravioleta/efectos adversos , Activación Viral/efectos de la radiación , Aciclovir/uso terapéutico , Adulto , Colágeno/metabolismo , ADN Viral/análisis , Quimioterapia Combinada , Femenino , Glucocorticoides/uso terapéutico , Herpesvirus Humano 1/fisiología , Humanos , Iritis/diagnóstico , Iritis/tratamiento farmacológico , Queratitis Herpética/diagnóstico , Queratitis Herpética/tratamiento farmacológico , Reacción en Cadena de la Polimerasa , Lágrimas/virología , Agudeza Visual
13.
J Refract Surg ; 23(7): 720-1, 2007 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-17912943

RESUMEN

PURPOSE: To report a case of late recurrence of bilateral diffuse lamellar keratitis (DLK) after LASIK. METHODS: A 39-year-old woman presented in the early postoperative period with bilateral DLK after hyperopic LASIK and was treated with topical steroids. One year after and with no obvious cause (idiopathic), recurrence of the same stage (stage III) of disease was observed. RESULTS: Slit-lamp examination revealed diffuse, multifocal, and granular haze in the interface. The microbiology culture was negative. Confocal microscopy demonstrated multiple activated keratocytes, debris, and inflammatory cells adjacent to the flap interface. After intense treatment with topical corticosteroids, DLK resolved and corneal transparency was achieved with complete restoration of visual acuity. CONCLUSIONS: Diffuse lamellar keratitis may recur in LASIK patients with previous episodes without an obvious cause (idiopathic). Early diagnosis and treatment with topical corticosteroids can achieve complete resolution without visual loss--even in advanced stages of DLK.


Asunto(s)
Hiperopía/cirugía , Queratitis/etiología , Queratomileusis por Láser In Situ/efectos adversos , Adulto , Dexametasona/administración & dosificación , Femenino , Glucocorticoides/administración & dosificación , Humanos , Queratitis/diagnóstico , Queratitis/tratamiento farmacológico , Microscopía Confocal , Recurrencia , Agudeza Visual
14.
Am J Ophthalmol ; 144(2): 181-185, 2007 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-17533106

RESUMEN

PURPOSE: To report the long-term refractive results of photorefractive keratectomy (PRK) and laser in situ keratomileusis (LASIK) in patients with thin corneas. DESIGN: A long-term, retrospective, non-randomized follow-up study. METHODS: Sixty-three patients (124 eyes) (28 males and 35 females), who had a preoperative central corneal thickness (CCT) of less than 500 microns and completed at least one year of follow-up examinations after surgery. Thirty-five patients (68 eyes) underwent PRK and 28 patients (56 eyes) underwent LASIK. RESULTS: Mean preoperative corneal pachymetry was 484.95 +/- 6.65 microm (range, 470 to 498 microm) and 482.38 +/- 10.73 microm (range, 453 to 499 microm) for LASIK and PRK, respectively. No intraoperative complications were found in both groups. None of the included eyes developed postrefractive corneal ectasia. The mean predictability for the PRK group was 0.08 diopters (D) with a standard deviation of 0.40 D (range, -1.38 to 1.00 D), and the mean predictability for the LASIK group was 0.14 D with a standard deviation of 0.55 D (range, -1.25 to 1.33 D). CONCLUSIONS: Refractive laser surgery with LASIK or PRK in patients with thin corneas (less than 500 microm) seems to be a safe and predictable technique for myopic refractive corrections.


Asunto(s)
Córnea/patología , Queratomileusis por Láser In Situ , Miopía/cirugía , Queratectomía Fotorrefractiva , Adolescente , Adulto , Córnea/diagnóstico por imagen , Córnea/cirugía , Topografía de la Córnea , Femenino , Estudios de Seguimiento , Humanos , Láseres de Excímeros , Masculino , Persona de Mediana Edad , Miopía/diagnóstico por imagen , Miopía/patología , Periodo Posoperatorio , Factores de Tiempo , Tomografía de Coherencia Óptica , Resultado del Tratamiento , Ultrasonografía
15.
J Cataract Refract Surg ; 33(6): 971-7, 2007 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-17531689

RESUMEN

PURPOSE: To study the long-term results of photorefractive keratectomy (PRK) and laser in situ keratomileusis (LASIK) in low to moderate myopic corrections using the Pulzar Z1 system (CustomVis), a 213 nm wavelength solid-state laser. SETTING: University refractive surgery center. METHODS: This prospective noncomparative case series comprised 20 patients (40 eyes) who had refractive surgery using the Pulzar Z1 laser system. Manifest refraction, uncorrected visual acuity, best spectacle-corrected visual acuity (BSCVA), safety, predictability, stability, and confocal microscopy images were evaluated. RESULTS: Ten patients (20 eyes) had PRK and 10 patients (20 eyes) had LASIK. The mean follow-up was 13.9 months +/- 1.1 (SD) (range 12 to 17 months) and 14.6 +/- 1.2 months (range 12 to 18 months) in the PRK group and LASIK group, respectively. No eye lost a line of Snellen BSCVA during the follow-up period; 2 eyes (10%) gained 2 Snellen lines. There was a statistically significant decrease in spherical equivalent manifest refraction postoperatively in both groups (P<.05). Refractive stability was obtained during the first postoperative month and remained stable during the follow-up period, with no significant changes between any interval in both groups (P>.05). At the last follow-up, 95% of all eyes were within +/-1.00 diopter of emmetropia. No late postoperative complications were observed. CONCLUSION: Refractive surgery using the Pulzar Z1 213 nm wavelength solid-state laser was a safe, effective procedure in the treatment of low to moderate myopia.


Asunto(s)
Córnea/cirugía , Queratomileusis por Láser In Situ/métodos , Miopía/cirugía , Queratectomía Fotorrefractiva/métodos , Adulto , Córnea/patología , Femenino , Humanos , Láseres de Excímeros , Masculino , Microscopía Confocal , Miopía/diagnóstico , Complicaciones Posoperatorias , Estudios Prospectivos , Resultado del Tratamiento , Agudeza Visual
16.
J Cataract Refract Surg ; 33(5): 859-61, 2007 May.
Artículo en Inglés | MEDLINE | ID: mdl-17466861

RESUMEN

We report a patient treated for low myopia with laser in situ keratomileusis (LASIK) in one eye and photorefractive keratectomy (PRK) in the fellow eye. Corneal ectasia developed in the LASIK-treated eye. Preoperative corneal pachymetry, topography, and attempted correction were similar in both eyes. In patients whose corneas may be predisposed to instability, PRK may be a safer alternative procedure than LASIK.


Asunto(s)
Enfermedades de la Córnea/etiología , Queratomileusis por Láser In Situ/efectos adversos , Miopía/cirugía , Queratectomía Fotorrefractiva , Complicaciones Posoperatorias , Adulto , Córnea/patología , Enfermedades de la Córnea/diagnóstico , Topografía de la Córnea , Dilatación Patológica/diagnóstico , Dilatación Patológica/etiología , Humanos , Láseres de Excímeros , Masculino , Microscopía Confocal
17.
J Cataract Refract Surg ; 33(2): 191-6, 2007 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-17276257

RESUMEN

PURPOSE: To report the long-term (11-year) outcomes (stability and complications) of laser in situ keratomileusis (LASIK) in patients with high myopia. SETTING: University refractive surgery center. METHODS: Seven patients (4 with bilateral treatment and 3 with unilateral treatment) who had myopic LASIK and completed 11 years of follow-up were included in the study. RESULTS: The mean age of the 2 men and 5 women was 41.7 years +/- 6.5 (SD) (range 34 to 50 years). The mean follow-up was 140.18 +/- 6.70 months (range 132 to 150 months). At 11 years, the spherical equivalent error was statistically significantly reduced, from a mean of -12.96 +/- 3.17 diopters (D) (range -19.00 to -10.00 D) before LASIK to a mean of -1.14 +/- 1.67 D (range -4.25 to 1.00 D) after (P<.001). Predictability of postoperative refraction 6 months and 11 years after LASIK showed that 6 eyes (55%) were within +/-1.00 D of intended correction. No late postoperative complications occurred. Five patients (8 eyes, 73%) were satisfied with the final outcome. CONCLUSIONS: Laser in situ keratomileusis was moderately predictable in the correction of high degrees of myopia. After the sixth postoperative month, refractive and topographic stability were obtained. No long-term sight-threatening complications occurred during the follow-up period.


Asunto(s)
Córnea/cirugía , Queratomileusis por Láser In Situ , Miopía/cirugía , Adulto , Córnea/fisiopatología , Topografía de la Córnea , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Miopía/fisiopatología , Complicaciones Posoperatorias , Refracción Ocular/fisiología , Encuestas y Cuestionarios , Resultado del Tratamiento , Agudeza Visual/fisiología
18.
Am J Ophthalmol ; 143(2): 236-244, 2007 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-17184717

RESUMEN

PURPOSE: To evaluate long-term follow-up of Intacs microthin prescription inserts (Addition Technology, Inc, Fremont, California, USA) for the management of keratoconus. DESIGN: A long-term (five years) retrospective, follow-up study. METHODS: Seventeen eyes of 15 patients with keratoconus ages 24 to 52 years (mean age +/- standard deviation [SD], 34.0 +/- 10.5 years) who had completed five years of follow-up (mean follow-up +/- SD, 67.2 +/- 7.5 months; range, 58 to 78 months) were included. Two Intacs segments of 0.45-mm thickness were inserted in the cornea of each eye, aiming at embracing the keratoconus area to try to achieve maximal flattening. RESULTS: No late postoperative complications occurred in this series of patients. At five years, the spherical equivalent error was statistically significantly reduced (pre-Intacs, mean +/- SD -5.54 +/- 5.02 diopters [D]; range, -12.50 to 3.63 D; -3.02 +/- 2.65 D; range, -8.25 to 1.88 D) (P = .01). Pre-Intacs uncorrected visual acuity (UCVA) was 20/50 or worse in all eyes (range, counting fingers to 20/50), whereas, at the last follow-up examination, 10 (59%) of 17 eyes had UCVA of 20/50 or better (range, counting fingers to 20/32). Six eyes (35%) maintained the pre-Intacs best spectacle-corrected visual acuity (BSCVA) and one eye lost 3 lines of BSCVA, whereas the rest of the 10 eyes (59%) experienced a gain of one up to 8 lines. CONCLUSIONS: After five years, intracorneal ring segments implantation improved UCVA, BSCVA, and refraction in the majority of the keratoconus patients. There was no evidence of progressive sight-threatening complications in this study.


Asunto(s)
Córnea/fisiopatología , Queratocono/fisiopatología , Queratocono/cirugía , Prótesis e Implantes , Implantación de Prótesis/métodos , Agudeza Visual/fisiología , Adulto , Córnea/cirugía , Topografía de la Córnea , Remoción de Dispositivos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Microscopía Confocal , Persona de Mediana Edad , Polimetil Metacrilato , Complicaciones Posoperatorias , Refracción Ocular/fisiología , Estudios Retrospectivos , Encuestas y Cuestionarios
19.
Ophthalmology ; 113(11): 1909-17, 2006 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17074560

RESUMEN

OBJECTIVE: To report long-term follow-up of Intacs microthin prescription inserts for the management of post-LASIK corneal ectasia. DESIGN: Long-term (5 years), retrospective, nonrandomized study. PARTICIPANTS: Eight eyes of 5 patients with post-LASIK corneal ectasia (3 men and 2 women) ages 31 to 54 years (mean age+/-standard deviation [SD], 41.60+/-9.24 years) who had completed 5 years of follow-up (mean follow-up +/- SD, 60.1+/-4.9 months; range, 57-68 months). INTERVENTION: Two Intacs segments, inserted in the usual fashion, were used for low myopia correction (1 each nasally and temporally), with thickness based on the residual refraction of the patients. MAIN OUTCOME MEASURES: Manifest refraction, uncorrected and best spectacle-corrected visual acuity, patient satisfaction, topography, and confocal microscopy analysis. RESULTS: No intraoperative or late postoperative complications occurred in this series of patients. At 5 years, the SE error was statistically significantly reduced (pre-Intacs mean+/-SD, -5.47+/-2.66 diopters [D]; range, -11.50 to -3.00 D) to -2.56+/-3.44 D (range, -9.50 to 1.5 D; P = 0.01). At the end of the first postoperative year, refractive stability was obtained and remained stable during the follow-up period with no significant changes between the interval meantime (P>0.05). Pre-Intacs uncorrected visual acuity was 20/100 or worse in all eyes (range, counting fingers-20/100), whereas at the last follow-up examination, 6 (75%) of 8 eyes had uncorrected visual acuity of 20/40 or better (range, counting fingers-20/25). Two eyes (25%) maintained the pre-Intacs best spectacle-corrected visual acuity, whereas the rest of the eyes (6 eyes; 75%) experienced a gain of 1 or 2 lines. At the end of the first postoperative year, uncorrected and best-spectacle corrected visual acuity and topographic stability were obtained and were shown to have remained stable during the follow-up period with no significant changes between the interval meantime. Lamellar channel deposits were observed in confocal microscopy at or adjacent to the intrastromal ring segment. CONCLUSIONS: Refractive stability was maintained for up to 5 years in the treatment of post-LASIK corneal ectasia after Intacs implantation. There was no evidence of progressive time-dependent corneal ectasia, late regression, or sight-threatening complications in this study.


Asunto(s)
Enfermedades de la Córnea/etiología , Enfermedades de la Córnea/cirugía , Queratomileusis por Láser In Situ/efectos adversos , Prótesis e Implantes , Adulto , Enfermedades de la Córnea/diagnóstico , Enfermedades de la Córnea/fisiopatología , Topografía de la Córnea , Dilatación Patológica , Anteojos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Microscopía Confocal , Persona de Mediana Edad , Satisfacción del Paciente , Complicaciones Posoperatorias , Periodo Posoperatorio , Prótesis e Implantes/efectos adversos , Refracción Ocular , Estudios Retrospectivos , Encuestas y Cuestionarios , Agudeza Visual
20.
J Cataract Refract Surg ; 32(8): 1276-80, 2006 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16863961

RESUMEN

PURPOSE: To study the long-term efficacy, safety, and stability of laser in situ keratomileusis (LASIK) after unintentional ultrathin flap creation less than 80 mum. SETTING: University refractive surgery center. METHODS: This retrospective case series comprised 25 patients (33 eyes) who had LASIK after flap creation less than 80 mum with the Moria M2 disposable microkeratome (head 90 microm). Flap thickness was measured with intraoperative ultrasound pachymetry. Manifest refraction, uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity, predictability, stability, complications, patient satisfaction, and confocal microscopy images were studied. RESULTS: The mean follow-up was 14.58 months +/- 3.73 (SD) (range 12 to 25 months). The mean flap thickness was 72.1 +/- 5.9 microm (range 58 to 80 microm), and the mean preoperative spherical equivalent (SE) refraction was -5.59 +/- 2.01 diopters (D) (range -10.25 to -3.25 D). On the first postoperative day, the UCVA was 20/25 or better. The SE manifest refraction was 1.00 D or less in all patients. The mean SE manifest refraction was -0.75 +/- 0.55 D (range -1.00 to +0.75 D) (P < .01). At the last follow-up, changes in visual acuity and manifest refraction were not statistically significant; no late postoperative complications were observed. All patients were satisfied with the final outcome. Qualitative analysis of confocal microscopy images revealed interface particles and activated keratocytes. CONCLUSIONS: Despite the small sample and retrospective nature of the study, superficial LASIK seemed to be a safe and predictable technique for myopic refractive corrections. Patients were satisfied with the results and had rapid visual recovery with no intraoperative or early or late postoperative complications. If the safety and efficacy of an ultrathin flap are confirmed by additional studies, superficial LASIK could represent a new approach that combines the advantages of surface and lamellar procedures.


Asunto(s)
Sustancia Propia/cirugía , Queratomileusis por Láser In Situ/métodos , Miopía/cirugía , Colgajos Quirúrgicos/patología , Adulto , Sustancia Propia/diagnóstico por imagen , Sustancia Propia/patología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Microscopía Confocal , Persona de Mediana Edad , Refracción Ocular/fisiología , Estudios Retrospectivos , Encuestas y Cuestionarios , Resultado del Tratamiento , Ultrasonografía , Agudeza Visual/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA