Europace ; 20(6): 993-1000, 2018 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-28472387

RESUMEN

Aims: To determine the impact of permanent cardiac pacing after transcatheter aortic valve implantation (TAVI) with the CoreValveTM prosthesis in terms of all-cause mortality and morbidity [rehospitalizations for heart failure (HF) or stroke] at the long-term follow-up. Methods and results: The prospective analysis comprised 259 patients (138 women, 53.3%, age 78 ± 6 years) treated by a CoreValveTM prosthesis from April 2008 to December 2015. Forty-two patients were excluded for analysis: 9 with pre-existing permanent pacemaker (PPM) implantation, 19 who required a PPM during the follow-up and 14 patients because of hospital mortality during or after the CoreValveTM prosthesis implantation procedure. The remaining 217 patients were divided in two groups: Group-1 included those patients who required a PPM immediately after TAVI, and Group-2 included those patients who did not require permanent cardiac pacing at the long-term follow-up. Patients received follow-up at 1-month, 6-months, 12-months, and yearly thereafter. A total of 39 patients required a PPM immediately after TAVI (15.0%), but 178 patients (68.7%) did not. The mean follow-up was 37 ± 27 months (range 3-99 months) in both groups. There was no difference between the two groups in terms of all-cause mortality (52.6% vs. 56.8%, P = 0.125; HR 1.22 [0.87-1.77, 95% CI]), or stroke (13.3% vs. 15.1% P = 0.842; HR 1.12 [0.37-3.32, 95% CI]). However, patients who underwent PPM implantation developed an increase in readmissions for HF (21.1% vs. 31.9%, P = 0.015; HR 1.82 [1.23-3.92, 95% CI]). Conclusion: Patients requiring a PPM after TAVI did not have an increase in mortality, or an increase in the likelihood of developing a stroke at a long-term follow-up. However, this subgroup of patients showed an increase in rehospitalization due to HF at medium- and long-term follow-up.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Estimulación Cardíaca Artificial/métodos , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Cateterismo Cardíaco/métodos , Femenino , Humanos , Masculino , Evaluación de Procesos y Resultados en Atención de Salud , Readmisión del Paciente/estadística & datos numéricos , Diseño de Prótesis , Ajuste de Riesgo/métodos , España/epidemiología , Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA