1.
J Intensive Care ; 7: 45, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31452899

RESUMEN

BACKGROUND: Extracorporeal carbon dioxide removal (ECCO2R) is a promising technique for the management of acute respiratory failure, but with a limited level of evidence to support its use outside clinical trials and/or data collection initiatives. We report a collaborative initiative in a large metropolis. METHODS: To assess on a structural basis the rate of utilization as well as efficacy and safety parameters of 2 ECCO2R devices in 10 intensive care units (ICU) during a 2-year period. RESULTS: Seventy patients were recruited in 10 voluntary and specifically trained centers. The median utilization rate was 0.19 patient/month/center (min 0.04; max 1.20). ECCO2R was started under invasive mechanical ventilation (IMV) in 59 patients and non-invasive ventilation in 11 patients. The Hemolung Respiratory Assist System (Alung) was used in 53 patients and the iLA Activve iLA kit (Xenios Novalung) in 17 patients. Main indications were ultraprotective ventilation for ARDS patients (n = 24), shortening the duration of IMV in COPD patients (n = 21), preventing intubation in COPD patients (n = 9), and controlling hypercapnia and dynamic hyperinflation in mechanically ventilated patients with severe acute asthma (n = 6). A reduction in median V T was observed in ARDS patients from 5.9 to 4.1 ml/kg (p <0.001). A reduction in PaCO2 values was observed in AE-COPD patients from 67.5 to 51 mmHg (p< 0.001). Median duration of ECCO2R was 5 days (IQR 3-8). Reasons for ECCO2R discontinuation were improvement (n = 33), ECCO2R-related complications (n = 18), limitation of life-sustaining therapies or measures decision (n = 10), and death (n = 9). Main adverse events were hemolysis (n = 21), bleeding (n = 17), and lung membrane clotting (n = 11), with different profiles between the devices. Thirty-five deaths occurred during the ICU stay, 3 of which being ECCO2R-related. CONCLUSIONS: Based on a registry, we report a low rate of ECCO2R device utilization, mainly in severe COPD and ARDS patients. Physiological efficacy was confirmed in these two populations. We confirmed safety concerns such as hemolysis, bleeding, and thrombosis, with different profiles between the devices. Such results could help to design future studies aiming to enhance safety, to demonstrate a still-lacking strong clinical benefit of ECCO2R, and to guide the choice between different devices. TRIAL REGISTRATION: ClinicalTrials.gov: Identifier: NCT02965079 retrospectively registered https://clinicaltrials.gov/ct2/show/NCT02965079.

2.
Ann Fr Anesth Reanim ; 33(7-8): 466-71, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25172192

RESUMEN

The incidents related to the medical devices are common during anesthesia and in intensive care unit. These incidents are rarely the cause of complications because monitoring detects them early; alternative scenarios allow bearing these problems. Although the incidence of these complications has much declined, these incidents are serious adverse events and at the origin of life-threatening complications. Improper use of medical devices is the main factor that promotes the onset of these complications. To maintain a high level of security, it is necessary to use and control procedures according to the manufacturer recommendations. This is part of a strategy involving users, biomedical engineers and manufacturers. Several actions are effective in preventing the occurrence of these incidents: the control before use, the continuation of the performance of the equipment, use based on the recommendations of the experts and manufacturers and appropriate training. This strategy is best applied by a clinical expert who has extensive technical knowledge. This expert is a key player for users learning and allows establishing and maintaining rules of use in collaboration with medical staff and biomedical engineers and manufacturers.


Asunto(s)
Anestesiología/instrumentación , Cuidados Críticos , Falla de Equipo , Anestesiología/normas , Falla de Equipo/estadística & datos numéricos , Seguridad de Equipos , Humanos , Medición de Riesgo , Ventiladores Mecánicos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...