Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Int J Numer Method Biomed Eng ; 36(6): e3339, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32237044

RESUMEN

BACKGROUND: Experimental analyses of the flow of drug particles inside the human lung usually require that the patient be exposed to radiation and also of expensive equipment that often lack of enough accuracy. Numerical calculations based on CFD (computational fluid dynamics) have been proven to be a valuable tool to analyze flows in diverse applications. METHODS: The complexity of the human lung disallows running calculations on complete lung models due to the large number of cells that would be required. In this work, using a proprietary methodology, particle deposition in the lung is simulated by reducing its multiple branches to a single path. RESULTS: The tested flow rates were 18, 30, and 75 L min-1 , which are equivalent to different respiratory rates varying from light activity to heavy exercise. Most of the particles are accumulated in the upper airways, mainly at the mouth and also at the confluence of the larynx and the trachea (epiglottis), while the remaining particles travel across the lung. The reported procedure allowed simulating the operation of the entire lung by means of a single individual path. CONCLUSIONS: The obtained calculations are in good agreement with the experimental results found in the technical literature, thus showing that the model can provide a realistic description of the lung operation, while avoiding high computational costs. Moreover, the calculations suggest that particle sizes above 15 µm and inspiratory flows higher than 30 L min-1 must be avoided in order to allow drug particles to reach the lower airways.


Asunto(s)
Hidrodinámica , Tráquea/fisiología , Administración por Inhalación , Humanos , Laringe/fisiología , Pulmón/fisiología
2.
PLoS One ; 13(8): e0202128, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30102728

RESUMEN

PURPOSE: To compare aqueous humour (AH) dynamics in the presence of a precrystalline (Implantable Collamer Lens®; ICL) or iris-fixed (Artiflex®) phakic intraocular lens (PIOL). METHODS: By computational fluid dynamics simulation, AH flow was modelled through a peripheral iridotomy (PI) or central lens hole (both 360 µm) in the presence of an Artiflex or ICL lens, respectively. The impacts of AH flow were then determined in terms of wall shear stress (WSS) produced on the endothelium or crystalline lens. Effects were also modelled for different scenarios of pupil diameter (PD 3.5 or 5.5 mm), ICL vault (100, 350, 800 µm) and number of Artiflex iridotomies (1 or 2) and location (12 or 6 o'clock). RESULTS: For a PD of 3.5 mm, AH volumes flowing from the posterior to the anterior chamber were 37.6% of total flow through the lens hole (ICL) and 84.2% through PI (Artiflex). For an enlarged PD (5.5 mm), corresponding values were 10.3% and 81.9% respectively, so PI constitutes a very efficient way of evacuating AH. Central endothelial WSS in Pa was lower for the large vault ICL and the Artiflex (1-03 and 1.1-03 respectively) compared to the PIOL-free eye (1.6-03). Crystalline lens WSS was highest for the lowest vault ICL (1-04). CONCLUSIONS: AH flow varied according to the presence of a precrystalline or iris-fixed intraocular lens. Endothelial WSS was lower for an implanted ICL with large vault and Artiflex than in the PIOL-free eye, while highest crystalline WSS was recorded for the lowest vault ICL.


Asunto(s)
Humor Acuoso , Simulación por Computador , Hidrodinámica , Iris , Modelos Teóricos , Lentes Intraoculares Fáquicas , Humanos , Cristalino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...