Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Int J Hyperthermia ; 38(1): 447-460, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33730953

RESUMEN

PURPOSE: The localized heating of magnetic nanoparticles (MNPs) via the application of time-varying magnetic fields - a process known as magnetic field hyperthermia (MFH) - can greatly enhance existing options for cancer treatment; but for broad clinical uptake its optimization, reproducibility and safety must be comprehensively proven. As part of this effort, the quantification of MNP heating - characterized by the specific loss power (SLP), measured in W/g, or by the intrinsic loss power (ILP), in Hm2/kg - is frequently reported. However, in SLP/ILP measurements to date, the apparatus, the analysis techniques and the field conditions used by different researchers have varied greatly, leading to questions as to the reproducibility of the measurements. MATERIALS AND METHODS: An interlaboratory study (across N = 21 European sites) of calorimetry measurements that constitutes a snapshot of the current state-of-the-art within the MFH community has been undertaken. Identical samples of two stable nanoparticle systems were distributed to all participating laboratories. Raw measurement data as well as the results of in-house analysis techniques were collected along with details of the measurement apparatus used. Raw measurement data was further reanalyzed by universal application of the corrected-slope method to examine relative influences of apparatus and results processing. RESULTS: The data show that although there is very good intralaboratory repeatability, the overall interlaboratory measurement accuracy is poor, with the consolidated ILP data having standard deviations on the mean of ca. ± 30% to ± 40%. There is a strong systematic component to the uncertainties, and a clear rank correlation between the measuring laboratory and the ILP. Both of these are indications of a current lack of normalization in this field. A number of possible sources of systematic uncertainties are identified, and means determined to alleviate or minimize them. However, no single dominant factor was identified, and significant work remains to ascertain and remove the remaining uncertainty sources. CONCLUSION: We conclude that the study reveals a current lack of harmonization in MFH characterization of MNPs, and highlights the growing need for standardized, quantitative characterization techniques for this emerging medical technology.


Asunto(s)
Hipertermia Inducida , Humanos , Hipertermia , Campos Magnéticos , Magnetismo , Reproducibilidad de los Resultados
2.
Br J Surg ; 102(6): 646-52, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25868072

RESUMEN

BACKGROUND: Non-palpable breast cancers require localization-guided surgery and axillary staging using sentinel lymph node biopsy (SLNB). This study investigated the novel technique of magnetic-guided lesion localization and concurrent SLNB, which avoids the need for wire-guided localization and radioisotopes. METHODS: An ultrasound-guided intratumoral injection of magnetic tracer (0·5 ml) was performed in a protocol-driven predefined minimum of ten patients with palpable breast cancer to assess the ability of the magnetic tracer safely to localize the tumour at the site of injection and concurrently drain to the lymphatics. Once successful lesion localization had been confirmed (peak magnetometer count retained at the centre of the tumour), the technique was undertaken in a further 20 patients with non-palpable breast cancers awaiting wide local excision and SLNB. All patients underwent SLNB with both the magnetic and standard dual (radioisotope and Patent Blue V dye) techniques. RESULTS: Thirty-two patients were recruited, of whom 12 (1 with bilateral disease) presented with palpable and 20 with non-palpable breast cancer. Peak magnetometer counts were retained at the tumour centre in all palpable (13) and non-palpable (20) breast cancers. Re-excisions for involved margins were necessary in two patients with non-palpable breast cancers. The sentinel lymph node identification rates were 28 of 33 procedures for the magnetic technique alone, 32 of 33 for the magnetic technique combined with blue dye, and 32 of 33 for the standard dual technique. CONCLUSION: Magnetic lesion localization is feasible, with intratumoral magnetic tracer injection combined with a periareolar injection of blue dye for subsequent SNLB.


Asunto(s)
Neoplasias de la Mama/secundario , Medios de Contraste , Biopsia Guiada por Imagen/métodos , Compuestos de Hierro , Ganglios Linfáticos/patología , Biopsia del Ganglio Linfático Centinela/métodos , Adulto , Anciano , Neoplasias de la Mama/diagnóstico , Colorantes/administración & dosificación , Medios de Contraste/administración & dosificación , Femenino , Humanos , Inyecciones Intralesiones , Compuestos de Hierro/administración & dosificación , Metástasis Linfática , Fenómenos Magnéticos , Persona de Mediana Edad , Colorantes de Rosanilina/administración & dosificación
3.
Dalton Trans ; 44(7): 2943-52, 2015 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-25564784

RESUMEN

We review current synthetic routes to magnetic iron oxide nanoparticles for biomedical applications. We classify the different approaches used depending on their ability to generate magnetic particles that are either single-core (containing only one magnetic core, i.e. a single domain nanocrystal) or multi-core (containing several magnetic cores, i.e. single domain nanocrystals). The synthesis of single-core magnetic nanoparticles requires the use of surfactants during the particle generation, and careful control of the particle coating to prevent aggregation. Special attention has to be paid to avoid the presence of any toxic reagents after the synthesis if biomedical applications are intended. Several approaches exist to obtain multi-core particles based on the coating of particle aggregates; nevertheless, the production of multi-core particles with good control of the number of magnetic cores per particle, and of the degree of polydispersity of the core sizes, is still a difficult task. The control of the structure of the particles is of great relevance for biomedical applications as it has a major influence on the magnetic properties of the materials.


Asunto(s)
Ingeniería Biomédica/métodos , Compuestos Férricos/síntesis química , Nanopartículas de Magnetita/química , Nanopartículas del Metal/química , Ingeniería Biomédica/tendencias , Tamaño de la Partícula
4.
Nanoscale ; 7(5): 1768-75, 2015 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-25515238

RESUMEN

The adoption of magnetic hyperthermia as either a stand-alone or adjunct therapy for cancer is still far from being optimised due to the variable performance found in many iron oxide nanoparticle systems, including commercially available formulations. Herein, we present a reproducible and potentially scalable microwave-based method to make stable citric acid coated multi-core iron oxide nanoparticles, with exceptional magnetic heating parameters, viz. intrinsic loss parameters (ILPs) of up to 4.1 nH m(2) kg(-1), 35% better than the best commercial equivalents. We also probe the core-to-core magnetic interactions in the particles via remanence-derived Henkel and ΔM plots. These reveal a monotonic dependence of the ILP on the magnetic interaction field Hint, and show that the interactions are demagnetising in nature, and act to hinder the magnetic heating mechanism.


Asunto(s)
Ácido Cítrico/química , Óxido Ferrosoférrico/química , Hipertermia Inducida , Nanopartículas de Magnetita/química , Campos Magnéticos , Microondas , Temperatura
5.
J Nanosci Nanotechnol ; 12(3): 1843-51, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22754989

RESUMEN

The structural and magnetic properties of a collection of nanoparticles coated by Poly(methyl methacrylate) through a wet chemical synthesis have been investigated. The particles display either an amorphous (M = Fe, Co) M-B arrangement or a mixed structure bcc-Fe and fcc-Co + amorphous M-B. Both show the presence of a metal oxi-hydroxide formed in aqueous reduction. The organic coating facilitates technological handling. The cost-effective synthesis involves a reduction in a Poly(methyl methacrylate) aqueous solution of iron(II) or cobalt(II) sulphates (< 0.5 M) by sodium borohydride (< 0.5 M). The particles present an oxidized component, as deduced from X-ray diffraction, Mössbauer and Fe- and Co K-edge X-ray absorption spectroscopy and electron microscopy. For the ferrous alloys, this Fe-oxide is alpha-goethite, favoured by the aqueous solution. The Poly(methyl methacrylate) coating is confirmed by Fourier transform infrared spectroscopy. In pure amorphous core alloys there is a drastic change of the coercivity from bulk to around 30 Oe in the nanoparticles. The mixed structured alloys also lie in the soft magnetic regime. Magnetisation values at room temperature range around 100 emu/g. The coercivity stems from multidomain particles and their agglomeration, triggering the dipolar interactions.

6.
J R Soc Interface ; 9(76): 3008-16, 2012 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-22696487

RESUMEN

Delivery of cells into tubular tissue constructs with large diameters poses significant spatial and temporal challenges. This study describes preliminary findings for a novel process for rapid and uniform seeding of cells onto the luminal surface of large tubular constructs. Fibroblasts, tagged with superparamagnetic iron oxide nanoparticles (SPION), were directed onto the luminal surface of tubular constructs by a magnetic field generated by a k4-type Halbach cylinder device. The spatial distribution of attached cells, as measured by the mean number of cells, was compared with a conventional, dynamic, rotational cell-delivery technique. Cell loading onto the constructs was measured by microscopy and magnetic resonance imaging. The different seeding techniques employed had a significant effect on the spatial distribution of the cells (p < 0.0001). The number of attached cells at defined positions within the same construct was significantly different for the dynamic rotation technique (p < 0.05). In contrast, no significant differences in the number of cells attached to the luminal surface were found between the defined positions on the construct loaded with the Halbach cylinder. The technique described overcomes limitations associated with existing cell-delivery techniques and is amenable to a variety of tubular organs where rapid loading and uniform distribution of cells for therapeutic applications are required.


Asunto(s)
Trasplante de Células/métodos , Compuestos Férricos/uso terapéutico , Magnetismo , Nanopartículas de Magnetita/uso terapéutico , Ingeniería de Tejidos/métodos , Análisis de Varianza , Animales , Técnicas de Cultivo de Célula , Línea Celular , Supervivencia Celular , Compuestos Férricos/química , Nanopartículas de Magnetita/química , Ratones , Microscopía Electrónica de Transmisión
7.
Proc Biol Sci ; 270 Suppl 1: S62-4, 2003 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-12952638

RESUMEN

Elevated iron levels are associated with many types of neurodegenerative disease, such as Alzheimer's, Parkinson's and Huntington's diseases. However, these elevated iron levels do not necessarily correlate with elevated levels of the iron storage or transport proteins, ferritin and transferrin. As such, little is known about the form of this excess iron. It has recently been proposed that some of the excess iron in neurodegenerative tissue may be in the form of the magnetic iron oxide magnetite (Fe(3)O(4)). We demonstrate, for the first time to our knowledge, using highly sensitive superconducting quantum interference device (SQUID) magnetometry, that the concentrations of magnetite are found to be significantly higher in three samples of Alzheimer's disease tissue than in three age- and sex-matched controls. These results have implications, not only for disease progression, but also for possible early diagnosis.


Asunto(s)
Enfermedad de Alzheimer/patología , Hierro/metabolismo , Óxidos/metabolismo , Anciano , Anciano de 80 o más Años , Enfermedad de Alzheimer/metabolismo , Autopsia , Campos Electromagnéticos , Óxido Ferrosoférrico , Humanos
8.
Nature ; 407(6805): 691-2, 2000 Oct 12.
Artículo en Inglés | MEDLINE | ID: mdl-11048705
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...