Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
JCO Glob Oncol ; 10: e2300427, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38513187

RESUMEN

PURPOSE: This study aims to examine the association between exposure to major ambient air pollutants and the incidence and mortality of lung cancer and some nonlung cancers. METHODS: This meta-analysis used PubMed and EMBASE databases to access published studies that met the eligibility criteria. Primary analysis investigated the association between exposure to air pollutants and cancer incidence and mortality. Study quality was assessed using the Newcastle Ottawa Scale. Meta-analysis was conducted using R software. RESULTS: The meta-analysis included 61 studies, of which 53 were cohort studies and eight were case-control studies. Particulate matter 2.5 mm or less in diameter (PM2.5) was the exposure pollutant in half (55.5%), and lung cancer was the most frequently studied cancer in 59% of the studies. A pooled analysis of exposure reported in cohort and case-control studies and cancer incidence demonstrated a significant relationship (relative risk [RR], 1.04 [95% CI, 1.02 to 1.05]; I2, 88.93%; P < .05). A significant association was observed between exposure to pollutants such as PM2.5 (RR, 1.08 [95% CI, 1.04 to 1.12]; I2, 68.52%) and nitrogen dioxide (NO2) (RR, 1.03 [95% CI, 1.01 to 1.05]; I2, 73.52%) and lung cancer incidence. The relationship between exposure to the air pollutants and cancer mortality demonstrated a significant relationship (RR, 1.08 [95% CI, 1.07 to 1.10]; I2, 94.77%; P < .001). Among the four pollutants, PM2.5 (RR, 1.15 [95% CI, 1.08 to 1.22]; I2, 95.33%) and NO2 (RR, 1.05 [95% CI, 1.02 to 1.08]; I2, 89.98%) were associated with lung cancer mortality. CONCLUSION: The study confirms the association between air pollution exposure and lung cancer incidence and mortality. The meta-analysis results could contribute to community cancer prevention and diagnosis and help inform stakeholders and policymakers in decision making.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire , Neoplasias Pulmonares , Humanos , Incidencia , Dióxido de Nitrógeno/análisis , Exposición a Riesgos Ambientales/efectos adversos , Exposición a Riesgos Ambientales/análisis , Contaminación del Aire/efectos adversos , Contaminación del Aire/análisis , Contaminantes Atmosféricos/efectos adversos , Contaminantes Atmosféricos/análisis , Material Particulado/efectos adversos , Material Particulado/análisis , Neoplasias Pulmonares/epidemiología
2.
Environ Sci Pollut Res Int ; 30(28): 71813-71825, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34622409

RESUMEN

The leachates emanating from the landfills are high in organic loads and thus become potential sources of contamination for both surface and groundwater. As the landfill ages, the nature of leachate changes from acidic to alkaline. The change in pH level affects the chemical oxygen demand (COD)/biochemical oxygen demand (BOD) ratio and when it is less than 0.63, chemical treatments are more effective over the biological treatment methods such as upflow anaerobic sludge blankets (UASB). The existing literature suggests coagulation-flocculation and advanced oxidation process (Fenton) as effective methods for treating wastewater but no comparison of the two are available. Thus, the present study attempts to identify the most efficient coagulants out of ferric chloride (FeCl3), ferrous sulphate (FeSO4) and alum [Al2(SO4)3]. Ferric chloride leading to 99% colour removal, 98% COD removal, 99% decrease in total organic carbon, 94.3% removal in NH3-N and 91.4% removal in total Kjeldahl nitrogen is observed to be the most efficient coagulant and surprisingly, proves to be even better than Fenton. To understand the field applicability of the two treatment procedures, coagulation with FeCl3 and Fenton are compared with the UASB method which is currently employed at Gazipur landfill site, Delhi. With lesser operational cost than UASB, both FeCl3 and Fenton perform better on cost-efficiency scale. Switching from in-suit UASB method to the FeCl3 method of treatment may result in decreasing the operational cost by 71.9% and to conventional Fenton may result in decreasing the operational cost by 76.8%.


Asunto(s)
Eliminación de Residuos Líquidos , Contaminantes Químicos del Agua , Eliminación de Residuos Líquidos/métodos , Contaminantes Químicos del Agua/análisis , Compuestos Férricos , Instalaciones de Eliminación de Residuos
3.
Math Biosci Eng ; 19(11): 11114-11136, 2022 08 03.
Artículo en Inglés | MEDLINE | ID: mdl-36124583

RESUMEN

Water resources in India's Indo-Gangetic plains are over-exploited and vulnerable to impacts of climate change. The unequal spatial and temporal variation of meteorological, hydrological and hydrogeological parameters has created additional challenges for field engineers and policy planners. The groundwater and surface water are extensively utilized in the middle Gangetic plain for agriculture. The primary purpose of this study is to understand the discharge and recharge processes of groundwater system using trend analysis, and surface water and groundwater interaction using groundwater modelling. A comprehensive hydrological, and hydrogeological data analysis was carried out and a numerical groundwater model was developed for Bhojpur district, Bihar, India covering 2395 km2 geographical area, located in central Ganga basin. The groundwater level data analyses for the year 2018 revealed that depth to water level varies from 3.0 to 9.0 meter below ground level (m bgl) in the study area. The M-K test showed no significant declining trend in the groundwater level in the study area. The groundwater modelling results revealed that groundwater head is higher in the southern part of the district and the groundwater flow direction is from south-west to north-east. The groundwater head fluctuation between the monsoon and the summer seasons was observed to be 2 m, it is also witnessed that groundwater is contributing more to rivers in the monsoon season in comparison with other seasons. Impact of reduction in pumping on groundwater heads was also investigated, considering a 10% reduction in groundwater withdrawal. The results indicated an overall head rise of 2 m in the southern part and 0.2-0.5 m in the middle and northern part of the district.


Asunto(s)
Agua Subterránea , Agua , Monitoreo del Ambiente/métodos , Ríos , Abastecimiento de Agua
4.
Ecotoxicol Environ Saf ; 150: 305-311, 2018 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-29291582

RESUMEN

Two phase bioreactor was constructed, designed and developed to evaluate the chlorpyrifos remediation. Six biotic and abiotic factors (substrate-loading rate, slurry phase pH, slurry phase dissolved oxygen (DO), soil water ratio, temperature and soil micro flora load) were evaluated by design of experimental (DOE) methodology employing Taguchi's orthogonal array (OA). The selected six factors were considered at two levels L-8 array (2^7, 15 experiments) in the experimental design. The optimum operating conditions obtained from the methodology showed enhanced chlorpyrifos degradation from 283.86µg/g to 955.364µg/g by overall 70.34% of enhancement. In the present study, with the help of few well defined experimental parameters a mathematical model was constructed to understand the complex bioremediation process and optimize the approximate parameters upto great accuracy.


Asunto(s)
Reactores Biológicos , Cloropirifos/análisis , Modelos Teóricos , Contaminantes del Suelo/análisis , Biodegradación Ambiental , Cloropirifos/metabolismo , Oxígeno , Proyectos de Investigación , Suelo/química , Contaminantes del Suelo/metabolismo , Temperatura , Agua
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...