Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
J Can Assoc Gastroenterol ; 7(2): 149-153, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38596804

RESUMEN

Background: The virtual scale endoscope (VSE) helps endoscopists measure colorectal polyp size more accurately compared to visual assessment (VA). However, previous studies were not adequately powered to evaluate the sizing of polyps at clinically relevant size thresholds and relative accuracy for size subgroups. Methods: We created 64 artificial polyps of varied sizes and Paris class morphology, randomly assigned 1:1 to be measured (383 total measurement datapoints with VSE and VA by 6 endoscopists blinded to true size) in a colon model. We added data from two previous trials (480 measurement datapoints). We evaluated for correct classification of polyps into size groups at 3 mm, 5 mm, 10 mm, and 20 mm size thresholds and the relative size measurement accuracy for diminutive polyps (≤5 mm), small polyps (5-9 mm), large polyps at 10-19 mm, and polyps (≥20). Results: VSE had significantly less size group misclassifications at the 5 mm, and 10 mm thresholds (28 percent vs. 45 percent, P = 0.0159 and 26 percent vs. 44 percent, P = 0.0135, respectively). For the 3 mm and 20 mm thresholds, VSE had lower misclassifications; however, this was not statistically significant (36 percent vs. 46 percent, P = 0.3853 and 38 percent vs. 41 percent, P = 0.2705, respectively). The relative size measurement accuracy was significantly higher for VSE compared to VA for all size subgroups (diminutive (P < 0.01), small polyps (P < 0.01), 10-19 mm (P < 0.01), and ≥20 mm (P < 0.01)). Conclusion: VSE outperforms VA in categorizing polyps into size groups at the clinically relevant size thresholds of 5 mm and 10 mm. Using VSE resulted in significantly higher relative measurement accuracy for all size subgroups.

2.
Gastroenterology ; 2024 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-38331204

RESUMEN

BACKGROUND & AIMS: Artificial intelligence (AI)-based optical diagnosis systems (CADx) have been developed to allow pathology prediction of colorectal polyps during colonoscopies. However, CADx systems have not yet been validated for autonomous performance. Therefore, we conducted a trial comparing autonomous AI to AI-assisted human (AI-H) optical diagnosis. METHODS: We performed a randomized noninferiority trial of patients undergoing elective colonoscopies at 1 academic institution. Patients were randomized into (1) autonomous AI-based CADx optical diagnosis of diminutive polyps without human input or (2) diagnosis by endoscopists who performed optical diagnosis of diminutive polyps after seeing the real-time CADx diagnosis. The primary outcome was accuracy in optical diagnosis in both arms using pathology as the gold standard. Secondary outcomes included agreement with pathology for surveillance intervals. RESULTS: A total of 467 patients were randomized (238 patients/158 polyps in the autonomous AI group and 229 patients/179 polyps in the AI-H group). Accuracy for optical diagnosis was 77.2% (95% confidence interval [CI], 69.7-84.7) in the autonomous AI group and 72.1% (95% CI, 65.5-78.6) in the AI-H group (P = .86). For high-confidence diagnoses, accuracy for optical diagnosis was 77.2% (95% CI, 69.7-84.7) in the autonomous AI group and 75.5% (95% CI, 67.9-82.0) in the AI-H group. Autonomous AI had statistically significantly higher agreement with pathology-based surveillance intervals compared to AI-H (91.5% [95% CI, 86.9-96.1] vs 82.1% [95% CI, 76.5-87.7]; P = .016). CONCLUSIONS: Autonomous AI-based optical diagnosis exhibits noninferior accuracy to endoscopist-based diagnosis. Both autonomous AI and AI-H exhibited relatively low accuracy for optical diagnosis; however, autonomous AI achieved higher agreement with pathology-based surveillance intervals. (ClinicalTrials.gov, Number NCT05236790).

3.
Am J Gastroenterol ; 2024 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-38084850

RESUMEN

INTRODUCTION: This study aimed to compare the accuracy of polyp size measurements using a virtual scale endoscope (VSE) with an integrated laser-based adaptive scale function and visual assessment (VA) during colonoscopies. METHODS: We conducted a single-blinded, prospective randomized controlled trial. Eligible patients (aged 45-80 years) undergoing screening, surveillance, or diagnostic colonoscopies were randomly assigned (1:1) into 2 groups. In the intervention group, all detected polyps were measured for size using VSE; in the control group, all polyps were measured using VA. Size measurements were compared with a reference standard of digital caliper measurement immediately post polypectomy. The primary outcome was the relative accuracy of real-time VSE measurement compared with VA. Secondary outcomes included the mean differences and the correlations between VSE or VA sizes and the reference standard of measurement. RESULTS: Overall, 230 patients were enrolled and randomized. The relative size measurement accuracy of VSE was 84% in 118 polyps, which was significantly higher than that of VA (105 polyps; 68.4%, P < 0.001). VSE resulted in a significantly higher percentage of size measurements within 25% of true size compared with VA (81.4% vs 41%, P < 0.001). VSE had a significantly lower percentage for >5-mm polyps incorrectly sized as 1-5 mm compared with VA (13.5% vs 57.1%; P < 0.001) and a significantly lower percentage for >3-mm polyps incorrectly sized as 1-3 mm compared with VA (11.3% vs 56.5%; P < 0.001). DISCUSSION: VSE significantly improves the size measurement accuracy of colorectal polyps during colonoscopies compared with VA and results in fewer misclassifications at relevant decision-making size thresholds.

4.
Endosc Int Open ; 11(1): E128-E135, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36726860

RESUMEN

Background and study aims Accurate polyp size measurement is important for guideline conforming choice of polypectomy techniques and subsequent surveillance interval assignments. Some endoscopic tools (biopsy forceps [BF] or endoscopic rulers [ER]) exist to help with visual size estimation. A virtual scale endoscope (VSE) has been developed that allows superimposing a virtual measurement scale during live endoscopies. Our aim was to evaluate the performance of VSE when compared to ER and BF-based measurement. Methods We conducted a preclinical randomized trial to evaluate the relative accuracy of size measurement of simulated colorectal polyps when using: VSE, ER, and BF. Six endoscopists performed 60 measurements randomized at a 1:1:1 ratio using each method. Primary outcome was relative accuracy in polyp size measurement. Secondary outcomes included misclassification of sizes at the 5-, 10-, and 20-mm thresholds. Results A total of 360 measurements were performed. The relative accuracy of BF, ER, and VSE was 78.9 % (95 %CI = 76.2-81.5), 78.4 % (95 %CI = 76.0-80.8), and 82.7 % (95 %CI = 80.8-84.8). VSE had significantly higher accuracy compared to BF ( P  = 0.02) and ER ( P  = 0.006). VSE misclassified a lower percentage of polyps > 5 mm as ≤ 5 mm (9.4 %) compared to BF (15.7 %) and ER (20.9 %). VSE misclassified a lower percentage of ≥ 20 mm polyps as < 20 mm (8.3 %) compared with BF (66.7 %) and ER (75.0 %). Of polyps ≥10mm, 25.6 %, 25.5 %, and 22.5 % were misclassified as <10 mm with ER, BF, and VSE, respectively. Conclusions VSE had significantly higher relative accuracy in measuring polyps compared to ER or BF assisted measurement. VSE improves correct classification of polyps at clinically important size thresholds.

5.
Dig Endosc ; 35(5): 638-644, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36514183

RESUMEN

OBJECTIVES: The virtual scale endoscope (VSE) allows projection of a virtual scale onto colorectal polyps allowing real-time size measurements. We studied the relative accuracy of VSE compared to visual assessment (VA) for the measuring simulated polyps of different size and morphology groups. METHODS: We conducted a blinded randomized controlled trial using simulated polyps within a colon model. Sixty simulated polyps were evenly distributed across four size groups (1-5, >5-9.9, 10-19.9, and ≥20 mm) and three Paris morphology groups (flat, sessile, and pedunculated). Six endoscopists performed polyp size measurements using random allocation of either VA or VSE. RESULTS: A total of 359 measurements were completed. The relative accuracy of VSE was significantly higher when compared to VA for all size groups >5 mm (P = 0.004, P < 0.001, P < 0.001). For polyps ≤5 mm, the relative accuracy of VSE compared to VA was not significantly higher (P = 0.186). The relative accuracy of VSE was significantly higher when compared to VA for all morphology groups. VSE misclassified a lower percentage of >5 mm polyps as ≤5 mm (2.9%), ≥10 mm polyps as <10 mm (5.5%), and ≥20 mm polyps as <20 mm (21.7%) compared to VA (11.2%, 24.7%, and 52.3% respectively; P = 0.008, P < 0.001, and P = 0.003). CONCLUSION: Virtual scale endoscope had significantly higher relative accuracies for every polyp size group or morphology type aside from diminutive. VSE enables the endoscopist to better classify polyps into correct size categories at clinically relevant size thresholds of 5, 10, and 20 mm.


Asunto(s)
Pólipos del Colon , Neoplasias Colorrectales , Humanos , Pólipos del Colon/diagnóstico , Pólipos del Colon/cirugía , Colonoscopía , Neoplasias Colorrectales/cirugía , Endoscopios
6.
Endoscopy ; 55(10): 929-937, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-36377124

RESUMEN

BACKGROUND : Cold snare polypectomy (CSP) is increasingly used for polypectomy and is recommended as the first-line modality for small (< 10 mm) polyps. This study aimed to evaluate incomplete resection rates (IRRs) when using CSP for colorectal polyps of 4-20 mm. METHODS : Adults (45-80 years) undergoing screening, surveillance, or diagnostic colonoscopy and CSP by one of nine endoscopists were included. The primary outcome was the IRR for colorectal polyps of 4-20 mm, defined as the presence of polyp tissue in marginal biopsies after resection of serrated polyps or adenomas. Secondary outcomes included the IRR for serrated polyps, ease of resection, and complications. RESULTS: 413 patients were included (mean age 63; 48 % women) and 182 polyps sized 4-20 mm were detected and removed by CSP. CSP required conversion to hot snare resection in < 1 % of polyps of < 10 mm and 44 % of polyps sized 10-20 mm. The IRRs for polyps < 10 mm and ≥ 10 mm were 18 % and 21 %. The IRR was higher for serrated polyps (26 %) compared with adenomas (16 %). The IRR was higher for flat (IIa) polyps (odds ratio [OR] 2.9, 95 %CI 1.1-7.4); and when resection was judged as difficult (OR 4.2, 95 %CI 1.5-12.1), piecemeal resection was performed (OR 6.6, 95 %CI 2.0-22.0), or visible residual polyp was present after the initial resection (OR 5.4, 95 %CI 2.0-14.9). Polyp location, use of a dedicated cold snare, and submucosal injection were not associated with incomplete resection. Intraprocedural bleeding requiring endoscopic intervention occurred in 4.7 %. CONCLUSIONS : CSP for polyps of 4-9 mm is safe and feasible; however, for lesions ≥ 10 mm, CSP failure occurs frequently, and the IRR remains high even after technical success. Incomplete resection was associated with flat polyps, visual residual polyp, piecemeal resection, and difficult polypectomies.


Asunto(s)
Adenoma , Pólipos del Colon , Neoplasias Colorrectales , Adulto , Humanos , Femenino , Persona de Mediana Edad , Masculino , Pólipos del Colon/cirugía , Pólipos del Colon/patología , Colonoscopía/métodos , Resultado del Tratamiento , Biopsia/métodos , Adenoma/cirugía , Adenoma/patología , Neoplasias Colorrectales/cirugía , Neoplasias Colorrectales/patología
7.
Endoscopy ; 54(4): 354-363, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34448185

RESUMEN

BACKGROUND: Clinical implementation of the resect-and-discard strategy has been difficult because optical diagnosis is highly operator dependent. This prospective study aimed to evaluate a resect-and-discard strategy that is not operator dependent. METHODS: The study evaluated a resect-and-discard strategy that uses the anatomical polyp location to classify colonic polyps into non-neoplastic or low risk neoplastic. All rectosigmoid diminutive polyps were considered hyperplastic and all polyps located proximally to the sigmoid colon were considered neoplastic. Surveillance interval assignments based on these a priori assumptions were compared with those based on actual pathology results and on optical diagnosis. The primary outcome was ≥ 90 % agreement with pathology in surveillance interval assignment. RESULTS: 1117 patients undergoing complete colonoscopy were included and 482 (43.1 %) had at least one diminutive polyp. Surveillance interval agreement between the location-based strategy and pathological findings using the 2020 US Multi-Society Task Force guideline was 97.0 % (95 % confidence interval [CI] 0.96-0.98), surpassing the ≥ 90 % benchmark. Optical diagnoses using the NICE and Sano classifications reached 89.1 % and 90.01 % agreement, respectively (P < 0.001), and were inferior to the location-based strategy. The location-based resect-and-discard strategy allowed a 69.7 % (95 %CI 0.67-0.72) reduction in pathology examinations compared with 55.3 % (95 %CI 0.52-0.58; NICE and Sano) and 41.9 % (95 %CI 0.39-0.45; WASP) with optical diagnosis. CONCLUSION: The location-based resect-and-discard strategy achieved very high surveillance interval agreement with pathology-based surveillance interval assignment, surpassing the ≥ 90 % benchmark and outperforming optical diagnosis in surveillance interval agreement and the number of pathology examinations avoided.


Asunto(s)
Pólipos del Colon , Neoplasias Colorrectales , Pólipos del Colon/diagnóstico por imagen , Pólipos del Colon/cirugía , Colonoscopía/métodos , Neoplasias Colorrectales/patología , Humanos , Estudios Prospectivos
8.
Gastrointest Endosc ; 93(3): 712-719.e1, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33275913

RESUMEN

BACKGROUND AND AIMS: Optical polyp diagnosis using image-enhanced endoscopy (IEE) allows for real-time histology prediction of colorectal polyps. The aim of this study was to evaluate a recently introduced IEE modality (Optivista [OV]; Pentax Medical, Tokyo, Japan) in a randomized controlled trial. METHODS: In a prospective cohort of subjects (ages 45-80 years) undergoing elective screening, surveillance, or diagnostic colonoscopy, all colorectal polyps between 1 and 5 mm underwent IEE assessment. Study subjects were randomized before their colonoscopy procedure to undergo optical polyp diagnosis using either OV IEE or iScan (IS) IEE. A validated IEE scale (NBI International Colorectal Endoscopic classification) was used for optical polyp diagnosis. The primary outcome was the agreement of surveillance intervals determined when using OV IEE compared with IS IEE in reference with pathology-based surveillance intervals. Secondary outcomes were the percentage of surveillance intervals that could be given on the same day as the procedure, percentage of pathology tests avoided, diagnostic performance, and negative predictive value (NPV) of optical diagnosis for rectosigmoid adenomas. RESULTS: Four hundred ten patients were enrolled in the trial. The polyp detection rate was 58.6%, and the adenoma detection rate was 38.8%. The proportion of correct surveillance interval assignment when using OV or IS IEE was 96.5% versus 96.0% (P = .75). A total of 65.1% of patients could be given same-day surveillance intervals when using OV IEE versus 73.1% for IS IEE (P = .07). The NPV for rectosigmoid adenomas (including sessile serrated adenomas) was 97.5% when using OV IEE and 88.2% when using IS IEE. Using high-confidence optical diagnosis instead of pathology would have resulted in a 44.3% elimination of required pathology examinations for OV IEE versus 52.8% for IS IEE (P = .34). CONCLUSIONS: Optical diagnosis using OV and IS IEE both surpassed the 90% benchmark of surveillance interval assignment, and no significant difference with regard to correct surveillance interval assignment was found. OV IEE surpassed the ≥90% NPV for rectosigmoid adenomas, whereas IS IEE did not. (Clinical trial registration number: NCT03515343.).


Asunto(s)
Pólipos del Colon , Neoplasias Colorrectales , Anciano , Anciano de 80 o más Años , Pólipos del Colon/diagnóstico por imagen , Colonoscopía , Neoplasias Colorrectales/diagnóstico por imagen , Humanos , Japón , Persona de Mediana Edad , Imagen de Banda Estrecha , Valor Predictivo de las Pruebas , Estudios Prospectivos
9.
Int J Mol Sci ; 20(13)2019 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-31269743

RESUMEN

To characterize effects of type 2 diabetes (T2D) on mRNA expression levels for 10 Cytochromes P450 (CYP450s), two carboxylesterases, and three drug transporters (ABCB1, ABCG2, SLCO2B1) in human duodenal biopsies. To compare drug metabolizing enzyme activities of four CYP450 isoenzymes in duodenal biopsies from patients with or without T2D. mRNA levels were quantified (RT-qPCR) in human duodenal biopsies obtained from patients with (n = 20) or without (n = 16) T2D undergoing a scheduled gastro-intestinal endoscopy. CYP450 activities were determined following incubation of biopsy homogenates with probe substrates for CYP2B6 (bupropion), CYP2C9 (tolbutamide), CYP2J2 (ebastine), and CYP3A4/5 (midazolam). Covariables related to inflammation, T2D, demographic, and genetics were investigated. T2D had no major effects on mRNA levels of all enzymes and transporters assessed. Formation rates of metabolites (pmoles mg protein-1 min-1) determined by LC-MS/MS for CYP2C9 (0.48 ± 0.26 vs. 0.41 ± 0.12), CYP2J2 (2.16 ± 1.70 vs. 1.69 ± 0.93), and CYP3A (5.25 ± 3.72 vs. 5.02 ± 4.76) were not different between biopsies obtained from individuals with or without T2D (p > 0.05). No CYP2B6 specific activity was measured. TNF-α levels were higher in T2D patients but did not correlate with any changes in mRNA expression levels for drug metabolizing enzymes or transporters in the duodenum. T2D did not modulate expression or activity of tested drug metabolizing enzymes and transporters in the human duodenum. Previously reported changes in drug oral clearances in patients with T2D could be due to a tissue-specific disease modulation occurring in the liver and/or in other parts of the intestines.


Asunto(s)
Transportadoras de Casetes de Unión a ATP/genética , Hidrolasas de Éster Carboxílico/genética , Sistema Enzimático del Citocromo P-450/genética , Diabetes Mellitus Tipo 2/genética , Duodeno/metabolismo , Subfamilia B de Transportador de Casetes de Unión a ATP/genética , Subfamilia B de Transportador de Casetes de Unión a ATP/metabolismo , Transportador de Casetes de Unión a ATP, Subfamilia G, Miembro 2/genética , Transportador de Casetes de Unión a ATP, Subfamilia G, Miembro 2/metabolismo , Transportadoras de Casetes de Unión a ATP/metabolismo , Adulto , Anciano , Hidrolasas de Éster Carboxílico/metabolismo , Sistema Enzimático del Citocromo P-450/metabolismo , Diabetes Mellitus Tipo 2/metabolismo , Femenino , Regulación de la Expresión Génica , Humanos , Masculino , Persona de Mediana Edad , Proteínas de Neoplasias/genética , Proteínas de Neoplasias/metabolismo , Transportadores de Anión Orgánico/genética , Transportadores de Anión Orgánico/metabolismo , Proyectos Piloto , ARN Mensajero/genética
10.
Endoscopy ; 51(7): 673-683, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30909308

RESUMEN

BACKGROUND: Colorectal cancer (CRC) is a major worldwide cause of cancer-related mortality. Colonoscopy programs based on guideline-recommended surveillance intervals have been put in place to reduce the morbidity and mortality associated with CRC. We were interested to evaluate clinical practice adherence to guideline-recommended surveillance intervals, the potential extent of early repeat colonoscopies, and causes of nonadherence to guideline recommendations. METHODS: We performed a literature search for articles reporting on guideline adherence for surveillance colonoscopies. Exclusion criteria included inflammatory bowel disease and hereditary CRC syndrome cohorts. Primary outcome was correct interval assignment in patients undergoing surveillance colonoscopy. Groups were assessed for adherence according to their respective guideline recommendations (North American or European). RESULTS: 16 studies were included in the analysis. The mean colonoscopy surveillance interval adherence rate was 48.8 % (95 % confidence interval [CI] 37.3 - 60.4). For North American guidelines, surveillance interval assignments were adherent to guideline recommendations in 44.7 % (95 %CI 24.2 - 66.3) of patients after detection of low risk lesions and in 54.6 % (95 %CI 41.4 - 67.4) after detection of high risk lesions. For European guidelines, surveillance interval assignments were adherent to recommendations in 24.4 % (95 %CI 1.1 - 63.4) of patients after detection of low risk lesions and in 73.6 % (95 %CI 35.5 - 98.8) after detection of high risk lesions. CONCLUSIONS: The worldwide adherence to surveillance colonoscopy guidelines was low, with more than 50 % of patients undergoing repeat colonoscopies either too early or too late. Early repeat colonoscopies occurred with the highest frequency for patients in whom only hyperplastic polyps or low risk adenomas were found.


Asunto(s)
Colectomía , Colonoscopía/normas , Neoplasias Colorrectales/diagnóstico , Detección Precoz del Cáncer/normas , Adhesión a Directriz , Recurrencia Local de Neoplasia/diagnóstico , Salud Global , Humanos , Morbilidad/tendencias , Recurrencia Local de Neoplasia/epidemiología , Periodo Posoperatorio , Tasa de Supervivencia/tendencias
11.
J Leukoc Biol ; 98(4): 671-81, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26162403

RESUMEN

Human Slan DCs have been studied in patients with psoriasis, rheumatoid arthritis, cancer, and autoimmune diseases. In this study, we investigated the frequency, phenotype, and function of Slan DCs in blood, colon, as well as mLNs of patients with IBD. We first show that the frequency of circulating CD14(dull)Slan DCs was reduced in CD patients refractory to immunosuppressive drugs or TNF-α blockers relative to untreated CD, UC, and healthy subjects. In blood of CD patients, Slan DCs expressed CD172a, as detected by CD47 fusion protein binding, when compared with its lack of expression in control subjects. Next, we demonstrate that CD172a(+)Slan DCs that produced IL-1ß and TNF-α accumulated in mLNs and colons of CD patients. The CD172a(+)Slan DCs up-regulated their expression of CD14 in CD tissues and the proinflammatory cytokines were produced in CD14(bright)CD172a(+)Slan DCs. By contrast, no difference was noted in the frequency of Slan DCs between inflamed, noninflamed colonic mucosa of UC patients and control, non-IBD donors. Finally, the percentage of cytokine-producing Slan DCs also augmented in response to TLR2 and NOD2 in in vitro stimulation in PBMCs of CD, but not UC, patients. In conclusion, we propose that proinflammatory CD14(bright)CD172a(+)Slan DCs are a distinguishing feature between CD and UC, as these cells accumulate uniquely in mLNs and colonic mucosa of CD patients. Thus, Slan DCs may contribute to CD immunopathogenesis.


Asunto(s)
Colitis Ulcerosa/inmunología , Colon/inmunología , Enfermedad de Crohn/inmunología , Células Dendríticas/inmunología , Ganglios Linfáticos/inmunología , Adulto , Anciano , Amino Azúcares/biosíntesis , Amino Azúcares/inmunología , Citocinas/biosíntesis , Femenino , Citometría de Flujo , Humanos , Inmunohistoquímica , Mucosa Intestinal/inmunología , Masculino , Persona de Mediana Edad , Adulto Joven
13.
J Exp Med ; 210(6): 1251-63, 2013 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-23669395

RESUMEN

In mice, the transfer of CD172a(+) (SIRP-α) dendritic cells (DCs) elicits T cell-driven colitis, whereas treatment with CD47-Fc protein, a CD172a-binding agent, confers protection. The aim of this study was to elucidate the nature and functional properties of human CD172a(+) DCs in chronic intestinal inflammation. Here, we show that CD172a(+)CD11c(+) cells accumulate in the mesenteric lymph nodes (mLNs) and inflamed intestinal mucosa in patients with Crohn's disease (CD). These cells are distinct from resident DCs and may coexpress markers typically associated with monocyte-derived inflammatory DCs such as CD14 and/or DC-SIGN, E-Cadherin, and/or CX3CR1. Spontaneous IL-1ß and TNF production by HLA-DR(+) cells in CD tissues is restricted to those expressing CD172a. An avidity-improved CD47 fusion protein (CD47-Var1) suppresses the release of a wide array of inflammatory cytokines by CD172a(+) cells, which may include HLA-DR(-)CD172a(+) neutrophils, in inflamed colonic explant cultures and impairs the ability of HLA-DR(+)CD172a(+) cells to activate memory Th17 but not Th1 responses in mLNs. In conclusion, targeting CD172a(+) cells may represent novel therapeutic perspectives for patients with CD.


Asunto(s)
Antígenos de Diferenciación/metabolismo , Antígeno CD47/metabolismo , Enfermedad de Crohn/inmunología , Interleucina-1beta/metabolismo , Receptores Inmunológicos/metabolismo , Proteínas Recombinantes de Fusión/metabolismo , Factor de Necrosis Tumoral alfa/metabolismo , Receptor 1 de Quimiocinas CX3C , Cadherinas/metabolismo , Células Dendríticas/metabolismo , Antígenos HLA-DR/metabolismo , Humanos , Inflamación/metabolismo , Mucosa Intestinal/metabolismo , Ganglios Linfáticos/metabolismo , Monocitos/metabolismo , Receptores de Quimiocina/metabolismo , Células TH1/metabolismo , Células Th17/metabolismo
14.
Blood ; 120(24): 4761-71, 2012 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-23071273

RESUMEN

Basophils are a rare population of granulocytes that have long been associated with IgE-mediated and Th2-associated allergic diseases. However, the role of basophils in Th17 and/or Th1 diseases has not been reported. In the present study, we report that basophils can be detected in the mucosa of Th17-associated lung and inflammatory bowel disease and accumulate in inflamed colons containing large quantities of IL-33. We also demonstrate that circulating basophils increased memory Th17 responses. Accordingly, IL-3- or IL-33-activated basophils amplified IL-17 release in effector memory T cells (T(EM)), central memory T cells (T(CM)), and CCR6(+) CD4 T cells. More specifically, basophils promoted the emergence of IL-17(+)IFN-γ(-) and IL-17(+)IFN-γ(+), but not IL-17(-)IFN-γ(+) CD4 T cells in T(EM) and T(CM). Mechanistic analysis revealed that the enhancing effect of IL-17 production by basophils in T(EM) involved the ERK1/2 signaling pathway, occurred in a contact-independent manner, and was partially mediated by histamine via H(2) and H(4) histamine receptors. The results of the present study reveal a previously unknown function for basophils in augmenting Th17 and Th17/Th1 cytokine expression in memory CD4 T cells. Because basophils accumulated in inflamed inflammatory bowel disease tissues, we propose that these cells are key players in chronic inflammatory disorders beyond Th2.


Asunto(s)
Basófilos/inmunología , Linfocitos T CD4-Positivos/inmunología , Comunicación Celular/inmunología , Interleucina-17/inmunología , Células Th17/inmunología , Basófilos/metabolismo , Linfocitos T CD4-Positivos/efectos de los fármacos , Linfocitos T CD4-Positivos/metabolismo , Células Cultivadas , Técnicas de Cocultivo , Citometría de Flujo , Expresión Génica/efectos de los fármacos , Expresión Génica/inmunología , Histamina/inmunología , Histamina/metabolismo , Humanos , Memoria Inmunológica/inmunología , Enfermedades Inflamatorias del Intestino/inmunología , Enfermedades Inflamatorias del Intestino/metabolismo , Enfermedades Inflamatorias del Intestino/patología , Interferón gamma/inmunología , Interferón gamma/metabolismo , Interleucina-17/metabolismo , Interleucina-3/inmunología , Interleucina-3/farmacología , Interleucina-33 , Interleucinas/inmunología , Interleucinas/farmacología , Sistema de Señalización de MAP Quinasas/efectos de los fármacos , Sistema de Señalización de MAP Quinasas/inmunología , Neumonía/inmunología , Neumonía/metabolismo , Neumonía/patología , Receptores Histamínicos H2/genética , Receptores Histamínicos H2/inmunología , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Células Th17/efectos de los fármacos , Células Th17/metabolismo
15.
PLoS One ; 7(8): e41972, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22870271

RESUMEN

How do effector CD4 T cells escape cell death during the contraction of the immune response (IR) remain largely unknown. CD47, through interactions with thrombospondin-1 (TSP-1) and SIRP-α, is implicated in cell death and phagocytosis of malignant cells. Here, we reported a reduction in SIRP-α-Fc binding to effector memory T cells (T(EM)) and in vitro TCR-activated human CD4 T cells that was linked to TSP-1/CD47-induced cell death. The reduced SIRP-α-Fc binding (CD47(low) status) was not detected when CD4 T cells were stained with two anti-CD47 mAbs, which recognize distinct epitopes. In contrast, increased SIRP-α-Fc binding (CD47(high) status) marked central memory T cells (T(CM)) as well as activated CD4 T cells exposed to IL-2, and correlated with resistance to TSP-1/CD47-mediated killing. Auto-aggressive CD4 effectors, which accumulated in lymph nodes and at mucosal sites of patients with Crohn's disease, displayed a CD47(high) status despite a high level of TSP-1 release in colonic tissues. In mice, CD47 (CD47(low) status) was required on antigen (Ag)-specific CD4 effectors for the contraction of the IR in vivo, as significantly lower numbers of Ag-specific CD47(+/+)CD4 T cells were recovered when compared to Ag-specific CD47(-/-) CD4 T cells. In conclusion, we demonstrate that a transient change in the status of CD47, i.e. from CD47(high) to CD47(low), on CD4 effectors regulates the decision-making process that leads to CD47-mediated cell death and contraction of the IR while maintenance of a CD47(high) status on tissue-destructive CD4 effectors prevents the resolution of the inflammatory response.


Asunto(s)
Linfocitos T CD4-Positivos/inmunología , Antígeno CD47/inmunología , Supresión Clonal , Memoria Inmunológica , Animales , Antígenos de Diferenciación/genética , Antígenos de Diferenciación/inmunología , Linfocitos T CD4-Positivos/patología , Antígeno CD47/genética , Muerte Celular/genética , Enfermedad de Crohn/genética , Enfermedad de Crohn/inmunología , Enfermedad de Crohn/patología , Femenino , Humanos , Interleucina-2/genética , Interleucina-2/inmunología , Masculino , Ratones , Ratones Noqueados , Receptores Inmunológicos/genética , Receptores Inmunológicos/inmunología
16.
JAMA ; 297(21): 2360-72, 2007 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-17545690

RESUMEN

CONTEXT: Hereditary diffuse gastric cancer is caused by germline mutations in the epithelial cadherin (CDH1) gene and is characterized by an increased risk for diffuse gastric cancer and lobular breast cancer. OBJECTIVE: To determine whether recurring germline CDH1 mutations occurred due to independent mutational events or common ancestry. DESIGN, SETTING, AND PATIENTS: Thirty-eight families diagnosed clinically with hereditary diffuse gastric cancer were accrued between November 2004 and January 2006 and were analyzed for CDH1 mutations as part of an ongoing study at the British Columbia Cancer Agency. Twenty-six families had at least 2 gastric cancer cases with 1 case of diffuse gastric cancer in a person younger than 50 years; 12 families had either a single case of diffuse gastric cancer diagnosed in a person younger than 35 years or multiple cases of diffuse gastric cancer diagnosed in persons older than 50 years. MAIN OUTCOME MEASURES: Classification of family members as carriers or noncarriers of CDH1 mutations. Haplotype analysis to assess recurring mutations for common ancestry was performed on 7 families from this study and 7 previously reported families with the same mutations. RESULTS: Thirteen mutations (6 novel) were identified in 15 of the 38 families (40% detection rate). The 1137G>A splicing mutation and the 1901C>T (A634V) missense/splicing mutation occurred on common haplotypes in 2 families but on different haplotypes in a third family. The 2195G>A (R732Q) missense/splicing mutation occurred in 2 families on different haplotypes. The 2064-2065delTG mutation occurred on a common haplotype in 2 families. Two families from this study plus 2 additional families carrying the novel 2398delC mutation shared a common haplotype, suggesting a founder effect. All 4 families originate from the southeast coast of Newfoundland. Due to concentrations of lobular breast cancer cases, 2 branches of this family had been diagnosed as having hereditary breast cancer and were tested for BRCA mutations. Within these 4 families, the cumulative risk by age 75 years in mutation carriers for clinically detected gastric cancer was 40% (95% confidence interval [CI], 12%-91%) for males and 63% (95% CI, 19%-99%) for females and the risk for breast cancer in female mutation carriers was 52% (95% CI, 29%-94%). CONCLUSIONS: Recurrent CDH1 mutations in families with hereditary diffuse gastric cancer are due to both independent mutational events and common ancestry. The presence of a founder mutation from Newfoundland is strongly supported.


Asunto(s)
Cadherinas/genética , Efecto Fundador , Mutación de Línea Germinal , Neoplasias Gástricas/genética , Adulto , Edad de Inicio , Anciano , Anciano de 80 o más Años , Antígenos CD , Análisis Mutacional de ADN , Femenino , Tamización de Portadores Genéticos , Asesoramiento Genético , Haplotipos , Heterocigoto , Humanos , Masculino , Persona de Mediana Edad , Mutación , Terranova y Labrador/epidemiología , Linaje , Penetrancia , Neoplasias Gástricas/mortalidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...