Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Nat Commun ; 12(1): 1638, 2021 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-33712576

RESUMEN

Key insights in materials at extreme temperatures and pressures can be gained by accurate measurements that determine the electrical conductivity. Free-electron laser pulses can ionize and excite matter out of equilibrium on femtosecond time scales, modifying the electronic and ionic structures and enhancing electronic scattering properties. The transient evolution of the conductivity manifests the energy coupling from high temperature electrons to low temperature ions. Here we combine accelerator-based, high-brightness multi-cycle terahertz radiation with a single-shot electro-optic sampling technique to probe the evolution of DC electrical conductivity using terahertz transmission measurements on sub-picosecond time scales with a multi-undulator free electron laser. Our results allow the direct determination of the electron-electron and electron-ion scattering frequencies that are the major contributors of the electrical resistivity.

3.
Rev Sci Instrum ; 89(10): 10G112, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30399878

RESUMEN

A facility to calibrate x-ray imaging optics was built at Lawrence Livermore National Laboratory to support high energy density (HED) and inertial confinement fusion (ICF) diagnostics such as those at the National Ignition Facility and the Sandia Z-Machine. Calibration of the spectral reflectivity and resolution of these x-ray diagnostics enable absolute determination of the x-ray flux and wavelengths generated in the HED and ICF experiments. Measurement of the optic point spread function is used to determine spatial resolution of the optic. This facility was constructed to measure (1) the x-ray reflectivity to ±5% over a spectral range from 5 to 60 keV; (2) point spread functions with a resolution of 50 µm (currently) and 13 µm (future) in the image plane; and (3) optic distance relative to the x-ray source and detector to within ±100 µm in each dimension. This article describes the capabilities of the calibration facility, concept of operations, and initial data from selected x-ray optics.

4.
Phys Rev Lett ; 120(26): 265701, 2018 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-30004754

RESUMEN

In this work, we monitor the onset of nonthermal melting in single-crystal silicon by implementing an x-ray pump-x-ray probe scheme. Using the ultrashort pulses provided by the Linac Coherent Light Source (SLAC) and a custom-built split-and-delay line for hard x rays, we achieve the temporal resolution needed to detect the onset of the transition. Our data show no loss of long-range order up to 150±40 fs from photoabsorption, which we interpret as the time needed for the electronic system to equilibrate at or above the critical nonthermal melting temperature. Once such equilibration is reached, the loss of long-range atomic order proceeds inertially and is completed within 315±40 fs from photoabsorption.

5.
Phys Rev Lett ; 117(23): 237203, 2016 Dec 02.
Artículo en Inglés | MEDLINE | ID: mdl-27982654

RESUMEN

Sr_{2}CuTeO_{6} presents an opportunity for exploring low-dimensional magnetism on a square lattice of S=1/2 Cu^{2+} ions. We employ ab initio multireference configuration interaction calculations to unravel the Cu^{2+} electronic structure and to evaluate exchange interactions in Sr_{2}CuTeO_{6}. The latter results are validated by inelastic neutron scattering using linear spin-wave theory and series-expansion corrections for quantum effects to extract true coupling parameters. Using this methodology, which is quite general, we demonstrate that Sr_{2}CuTeO_{6} is an almost ideal realization of a nearest-neighbor Heisenberg antiferromagnet but with relatively weak coupling of 7.18(5) meV.

6.
Rev Sci Instrum ; 87(11): 11E313, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910456

RESUMEN

A dual-channel streaked soft x-ray imager has been designed and used on high energy-density physics experiments at the National Ignition Facility. This streaked imager creates two images of the same x-ray source using two slit apertures and a single shallow angle reflection from a nickel mirror. Thin filters are used to create narrow band pass images at 510 eV and 360 eV. When measuring a Planckian spectrum, the brightness ratio of the two images can be translated into a color-temperature, provided that the spectral sensitivity of the two images is well known. To reduce uncertainty and remove spectral features in the streak camera photocathode from this photon energy range, a thin 100 nm CsI on 50 nm Al streak camera photocathode was implemented. Provided that the spectral shape is well-known, then uncertainties on the spectral sensitivity limits the accuracy of the temperature measurement to approximately 4.5% at 100 eV.

7.
Rev Sci Instrum ; 87(11): 11E316, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910471

RESUMEN

Current two-dimensional X-ray imaging at the National Ignition Facility (NIF) uses time resolved pinhole cameras with ∼10-25 µm pinholes. This method has limitations in the smallest resolvable features that can be imaged with reasonable photon statistics for inertial confinement fusion (ICF) applications. ICF sources have a broadband self-emission spectrum that causes the pinhole images obtained, through thin foil filters, to contain a similarly broadband spectrum complicating the interpretation of structure in the source. In order to study phenomena on the scale of ∼5 µm, such as dopant mix in the ICF capsule, a narrow energy band, higher spatial resolution microscope system with improved signal/noise has been developed using X-ray optics. Utilizing grazing incidence mirrors in a Kirkpatrick-Baez microscope (KBM) configuration [P. Kirkpatrick and A. V. Baez, J. Opt. Soc. Am. 38, 766-774 (1948)], an X-ray microscope has been designed and fielded on NIF with four imaging channels. The KBM has ∼12 × magnification, <8 µm resolution, and higher throughput in comparison to similar pinhole systems. The first KBM mirrors are coated with a multilayer mirror to allow a "narrow band" energy response at 10.2 keV with ΔE ∼ 3 keV. By adjusting the mirror coating only, the energy response can be matched to the future experimental requirements. Several mirror packs have been commissioned and are interchangeable in the diagnostic snout.

8.
Rev Sci Instrum ; 87(11): 11E201, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910489

RESUMEN

We have developed and fielded x-ray penumbral imaging on the National Ignition Facility in order to enable sub-10 µm resolution imaging of stagnated plasma cores (hot spots) of spherically shock compressed spheres and shell implosion targets. By utilizing circular tungsten and tantalum apertures with diameters ranging from 20 µm to 2 mm, in combination with image plate and gated x-ray detectors as well as imaging magnifications ranging from 4 to 64, we have demonstrated high-resolution imaging of hot spot plasmas at x-ray energies above 5 keV. Here we give an overview of the experimental design criteria involved and demonstrate the most relevant influences on the reconstruction of x-ray penumbral images, as well as mitigation strategies of image degrading effects like over-exposed pixels, artifacts, and photon limited source emission. We describe experimental results showing the advantages of x-ray penumbral imaging over conventional Fraunhofer and photon limited pinhole imaging and showcase how internal hot spot microstructures can be resolved.

9.
Rev Sci Instrum ; 87(11): 11E709, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910491

RESUMEN

Atomic clusters can serve as ideal model systems for exploring ultrafast (∼100 fs) laser-driven ionization dynamics of dense matter on the nanometer scale. Resonant absorption of optical laser pulses enables heating to temperatures on the order of 1 keV at near solid density conditions. To date, direct probing of transient states of such nano-plasmas was limited to coherent x-ray imaging. Here we present the first measurement of spectrally resolved incoherent x-ray scattering from clusters, enabling measurements of transient temperature, densities, and ionization. Single shot x-ray Thomson scattering signals were recorded at 120 Hz using a crystal spectrometer in combination with a single-photon counting and energy-dispersive pnCCD. A precise pump laser collimation scheme enabled recording near background-free scattering spectra from Ar clusters with an unprecedented dynamic range of more than 3 orders of magnitude. Such measurements are important for understanding collective effects in laser-matter interactions on femtosecond time scales, opening new routes for the development of schemes for their ultrafast control.

10.
Rev Sci Instrum ; 87(5): 055110, 2016 05.
Artículo en Inglés | MEDLINE | ID: mdl-27250473

RESUMEN

A new streaked soft x-ray imager has been designed for use on high energy-density (HED) physics experiments at the National Ignition Facility based at the Lawrence Livermore National Laboratory. This streaked imager uses a slit aperture, single shallow angle reflection from a nickel mirror, and soft x-ray filtering to, when coupled to one of the NIF's x-ray streak cameras, record a 4× magnification, one-dimensional image of an x-ray source with a spatial resolution of less than 90 µm. The energy band pass produced depends upon the filter material used; for the first qualification shots, vanadium and silver-on-titanium filters were used to gate on photon energy ranges of approximately 300-510 eV and 200-400 eV, respectively. A two-channel version of the snout is available for x-ray sources up to 1 mm and a single-channel is available for larger sources up to 3 mm. Both the one and two-channel variants have been qualified on quartz wire and HED physics target shots.

11.
Rev Sci Instrum ; 85(11): 11D611, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25430187

RESUMEN

Current pinhole x ray imaging at the National Ignition Facility (NIF) is limited in resolution and signal throughput to the detector for Inertial Confinement Fusion applications, due to the viable range of pinhole sizes (10-25 µm) that can be deployed. A higher resolution and throughput diagnostic is in development using a Kirkpatrick-Baez microscope system (KBM). The system will achieve <9 µm resolution over a 300 µm field of view with a multilayer coating operating at 10.2 keV. Presented here are the first images from the uncoated NIF KBM configuration demonstrating high resolution has been achieved across the full 300 µm field of view.

12.
Phys Rev Lett ; 102(19): 197201, 2009 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-19518991

RESUMEN

We have studied the two-dimensional S=1/2 square-lattice antiferromagnet Cu(pz)_{2}(ClO4)_{2} (where pz denotes pyrazine), using neutron inelastic scattering and series expansion calculations. We show that the presence of antiferromagnetic next-nearest-neighbor interactions enhances quantum fluctuations associated with resonating valence bonds. Intermediate magnetic fields lead to a selective tuning of resonating valence bonds and a spectacular inversion of the zone-boundary dispersion, providing novel insight into 2D antiferromagnetism in the quantum limit.

13.
J Chem Phys ; 122(5): 54704, 2005 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-15740343

RESUMEN

Core level and valence band photoemission measurements combined with near edge x-ray absorption fine structure measurements were performed on a single C(70) layer adsorbed on polycrystalline Al (1 ML-C(70)/Al) (ML-monolayer), pure and doped with sodium atoms. The data obtained from the pure ML chemisorbed on Al surface show a semiconducting behavior of the system, which is characterized by a covalent bond between the adsorbate and the substrate. The same data show also that the C(70) molecules tend to orient themselves with the C(5v) axis perpendicular to the surface in analogy to what observed for 1 ML-C(70)/Cu(111). By doping the sample with sodium atoms a charge transfer from the alkali atoms to the lowest unoccupied molecular orbital (LUMO) of the C(70) molecules takes place, as underlined by the gradual increasing intensity of the C(70) LUMO peak as a function of doping. Nevertheless, no metallic phases are observed for any doping step.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...