Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38780711

RESUMEN

PURPOSE: Exercise imaging using current modalities can be challenging. This was patient focused study to establish the feasibility and reproducibility of exercise-cardiovascular magnetic resonance imaging (EX-CMR) acquired during continuous in-scanner exercise in asymptomatic patients with primary mitral regurgitation (MR). METHODS: This was a prospective, feasibility study. Biventricular volumes/function, aortic flow volume, MR volume (MR-Rvol) and regurgitant fraction (MR-RF) were assessed at rest and during low- (Low-EX) and moderate-intensity exercise (Mod-EX) in asymptomatic patients with primary MR. RESULTS: Twenty-five patients completed EX-CMR without complications. Whilst there were no significant changes in the left ventricular (LV) volumes, there was a significant increase in the LVEF (rest 63 ± 5% vs. Mod-EX 68 ± 6%;p = 0.01). There was a significant reduction in the right ventricular (RV) end-systolic volume (rest 68 ml(60-75) vs. Mod-EX 46 ml(39-59);p < 0.001) and a significant increase in the RV ejection fraction (rest 55 ± 5% vs. Mod-EX 65 ± 8%;p < 0.001). Whilst overall, there were no significant group changes in the MR-Rvol and MR-RF, individual responses were variable, with MR-Rvol increasing by ≥ 15 ml in 4(16%) patients and decreasing by ≥ 15 ml in 9(36%) of patients. The intra- and inter-observer reproducibility of LV volumes and aortic flow measurements were excellent, including at Mod-EX. CONCLUSION: EX-CMR is feasible and reproducible in patients with primary MR. During exercise, there is an increase in the LV and RV ejection fraction, reduction in the RV end-systolic volume and a variable response of MR-Rvol and MR-RF. Understanding the individual variability in MR-Rvol and MR-RF during physiological exercise may be clinically important.

2.
J Magn Reson Imaging ; 2024 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-38344930

RESUMEN

BACKGROUND: Four-dimensional-flow cardiac MR (4DF-MR) offers advantages in primary mitral regurgitation. The relationship between 4DF-MR-derived mitral regurgitant volume (MR-Rvol) and the post-operative left ventricular (LV) reverse remodeling has not yet been established. PURPOSE: To ascertain if the 4DF-MR-derived MR-Rvol correlates with the LV reverse remodeling in primary mitral regurgitation. STUDY TYPE: Prospective, single-center, two arm, interventional vs. nonintervention observational study. POPULATION: Forty-four patients (male N = 30; median age 68 [59-75]) with at least moderate primary mitral regurgitation; either awaiting mitral valve surgery (repair [MVr], replacement [MVR]) or undergoing "watchful waiting" (WW). FIELD STRENGTH/SEQUENCE: 5 T/Balanced steady-state free precession (bSSFP) sequence/Phase contrast imaging/Multishot echo-planar imaging pulse sequence (five shots). ASSESSMENT: Patients underwent transthoracic echocardiography (TTE), phase-contrast MR (PMRI), 4DF-MR and 6-minute walk test (6MWT) at baseline, and a follow-up PMRI and 6MWT at 6 months. MR-Rvol was quantified by PMRI, 4DF-MR, and TTE by one observer. The pre-operative MR-Rvol was correlated with the post-operative decrease in the LV end-diastolic volume index (LVEDVi). STATISTICAL TESTS: Included Student t-test/Mann-Whitney test/Fisher's exact test, Bland-Altman plots, linear regression analysis and receiver operating characteristic curves. Statistical significance was defined as P < 0.05. RESULTS: While Bland-Altman plots demonstrated similar bias between all the modalities, the limits of agreement were narrower between 4DF-MR and PMRI (bias 15; limits of agreement -36 mL to 65 mL), than between 4DF-MR and TTE (bias -8; limits of agreement -106 mL to 90 mL) and PMRI and TTE (bias -23; limits of agreement -105 mL to 59 mL). Linear regression analysis demonstrated a significant association between the MR-Rvol and the post-operative decrease in the LVEDVi, when the MR-Rvol was quantified by PMRI and 4DF-MR, but not by TTE (P = 0.73). 4DF-MR demonstrated the best diagnostic performance for reduction in the post-operative LVEDVi with the largest area under the curve (4DF-MR 0.83; vs. PMRI 0.78; and TTE 0.51; P = 0.89). DATA CONCLUSION: This study demonstrates the potential clinical utility of 4DF-MR in the assessment of primary mitral regurgitation. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 5.

3.
Int J Cardiovasc Imaging ; 39(9): 1707-1717, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37572176

RESUMEN

3D-transesophageal echocardiography (3D-TEE) is an alternative to multidetector row computed tomography (MDCT) for aortic annulus (AoA) sizing in preparation for Transcatheter aortic valve implantation (TAVI). We aim to evaluate how the fully automated (auto) and semi-automated (SA) TEE methods perform compared to conventional manual TEE method and the gold standard MDCT for annulus sizing both in expert and novice operators. In this prospective cohort study, eighty-nine patients with severe aortic stenosis underwent multimodality imaging with 3D-TEE and MDCT. Annular measurements were collected by expert echocardiographers using 3D auto, SA and manual methods and compared to MDCT. A novice in the field of echocardiography retrospectively measured the AoA for all patients using the same methods. TEE measurements, independently of the method used, had good to very good agreement to MDCT. They significantly underestimated aortic annular area and circumference vs. MDCT with the auto method underestimating it the most and the manual method the least (6.5% and 1.3% respectively for area and circumference). For experts, the manual TEE method offered the least systematic bias while the SA method had narrower limits of agreement (LOA). For the novice operator, SA method provided the least bias and narrower LOA vs. MDCT. There is good agreement between novice and experts for all 3 TEE methods but better agreement with auto and SA methods as opposed to manual one. Our study supports the use of 3D-TEE as a complementary method to MDCT for aortic annular sizing. The newer auto and SA software, that requires minimal operator intervention, is an easy to use, reliable and reproducible tool for aortic annulus sizing for experienced operators, and especially less experienced ones.


Asunto(s)
Estenosis de la Válvula Aórtica , Ecocardiografía Tridimensional , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estudios Retrospectivos , Estudios Prospectivos , Valor Predictivo de las Pruebas , Ecocardiografía Tridimensional/métodos , Programas Informáticos , Ecocardiografía Transesofágica/métodos , Tomografía Computarizada Multidetector/métodos
4.
J Cardiovasc Magn Reson ; 25(1): 43, 2023 07 27.
Artículo en Inglés | MEDLINE | ID: mdl-37496072

RESUMEN

BACKGROUND: When feasible, guidelines recommend mitral valve repair (MVr) over mitral valve replacement (MVR) to treat primary mitral regurgitation (MR), based upon historic outcome studies and transthoracic echocardiography (TTE) reverse remodeling studies. Cardiovascular magnetic resonance (CMR) offers reference standard biventricular assessment with superior MR quantification compared to TTE. Using serial CMR in primary MR patients, we aimed to investigate cardiac reverse remodeling and residual MR post-MVr vs MVR with chordal preservation. METHODS: 83 patients with ≥ moderate-severe MR on TTE were prospectively recruited. 6-min walk tests (6MWT) and CMR imaging including cine imaging, aortic/pulmonary through-plane phase contrast imaging, T1 maps and late-gadolinium-enhanced (LGE) imaging were performed at baseline and 6 months after mitral surgery or watchful waiting (control group). RESULTS: 72 patients completed follow-up (Controls = 20, MVr = 30 and MVR = 22). Surgical groups demonstrated comparable baseline cardiac indices and co-morbidities. At 6-months, MVr and MVR groups demonstrated comparable improvements in 6MWT distances (+ 57 ± 54 m vs + 64 ± 76 m respectively, p = 1), reduced indexed left ventricular end-diastolic volumes (LVEDVi; - 29 ± 21 ml/m2 vs - 37 ± 22 ml/m2 respectively, p = 0.584) and left atrial volumes (- 23 ± 30 ml/m2 and - 39 ± 26 ml/m2 respectively, p = 0.545). At 6-months, compared with controls, right ventricular ejection fraction was poorer post-MVr (47 ± 6.1% vs 53 ± 8.0% respectively, p = 0.01) compared to post-MVR (50 ± 5.7% vs 53 ± 8.0% respectively, p = 0.698). MVR resulted in lower residual MR-regurgitant fraction (RF) than MVr (12 ± 8.0% vs 21 ± 11% respectively, p = 0.022). Baseline and follow-up indices of diffuse and focal myocardial fibrosis (Native T1 relaxation times, extra-cellular volume and quantified LGE respectively) were comparable between groups. Stepwise multiple linear regression of indexed variables in the surgical groups demonstrated baseline indexed mitral regurgitant volume as the sole multivariate predictor of left ventricular (LV) end-diastolic reverse remodelling, baseline LVEDVi as the most significant independent multivariate predictor of follow-up LVEDVi, baseline indexed LV end-systolic volume as the sole multivariate predictor of follow-up LV ejection fraction and undergoing MVR (vs MVr) as the most significant (p < 0.001) baseline multivariate predictor of lower residual MR. CONCLUSION: In primary MR, MVR with chordal preservation may offer comparable cardiac reverse remodeling and functional benefits at 6-months when compared to MVr. Larger, multicenter CMR studies are required, which if the findings are confirmed could impact future surgical practice.


Asunto(s)
Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/patología , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Volumen Sistólico , Valor Predictivo de las Pruebas , Función Ventricular Derecha , Fibrosis
5.
Eur Heart J Case Rep ; 6(11): ytac412, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36381172

RESUMEN

Background: Malignant tumours of the aortic valve apparatus are extremely rare and difficult to diagnose. Their proximity to the coronary ostium may cause an acute coronary syndrome (ACS) either by infiltration or by embolization. Case summary: We report a case of primary aortic valve undifferentiated sarcoma causing recurrent episodes of ACS, and we provide a literature review for primary cardiac valve tumours. This case also highlights the need for further evaluation of other causes of ACS in patients with minimal coronary artery disease risk factors and recurrent ACS. Conclusions: The majority of valve tumours are fibroelastomas. Sarcomas are rare and lead to poor outcomes.

6.
Panminerva Med ; 63(3): 301-313, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33618512

RESUMEN

With a rapidly growing spectrum, non-specific symptoms and overlapping etiologies, pericardial diseases can represent a real diagnostic challenge. Consequently, multimodality imaging has taken a front seat in the diagnosis and management of these conditions. Cardiac CT offers an excellent anatomical characterization of pericardial thickening, fat stranding and/or presence of calcifications. and is also the preferred modality to assess extra-cardiac structures. Active pericardial inflammation, edema and fibrosis comprise pericardial characterization using CMR and allows for a precise diagnosis, disease staging and patient specific tailoring of therapies. PET scan still occupies a very modest role in the evaluation of pericardial diseases but might help discriminating malignant pericardial effusion and extrapulmonary tuberculous. More than ever, clinicians need to master how these modalities complement each other while avoiding unnecessary cost and to translate this knowledge into a more customized patient's care approach. The aim of this review was to recognize the role of multimodality imaging in the investigation of various pericardial diseases, assess how these modalities can impact the clinical course and treatment of these affections and finally elucidate their role in the patient's prognostication.


Asunto(s)
Derrame Pericárdico , Humanos , Derrame Pericárdico/diagnóstico por imagen , Derrame Pericárdico/terapia , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...