Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Kardiologiia ; 64(4): 31-37, 2024 Apr 30.
Artículo en Ruso, Inglés | MEDLINE | ID: mdl-38742513

RESUMEN

AIM: Identification of clinical and instrumental predictors for non-arrhythmic death in patients with heart failure (HF) and implantable cardioverter-defibrillator (ICD). MATERIAL AND METHODS: Through a telephone survey and examination of medical records from hospital and polyclinic databases, data were obtained on the alive/dead status and causes of death for 260 patients with heart failure (HF) and ICD included in the Kuzbass Registry of Patients with ICD. The follow-up period was 1.5 years. Clinical and instrumental parameters entered into the registry before the ICD implantation were included in a univariate and multivariate step-by-step analysis using the logistic (for qualitative variables) and linear (for quantitative variables) regression with calculation of regression coefficients and construction of a prognostic regression model. The quality of the created model was assessed using a ROC analysis. RESULTS: During the observation period, 54 (20.8%) patients died. In 21 (38.8%) patients, death occurred in the hospital and was caused by acute decompensated heart failure in 15 (71.4%) patients, myocardial infarction in 3 (14.3%) patients, stroke in 1 (4.7%) patient, and pneumonia in 2 (9.5%) patients. 33 (61.2%) patients died outside the hospital; the cause of death was stated as the underlying disease associated with acute decompensated heart failure: in 9 (27.2%) patients, dilated cardiomyopathy; in 1 (3.0%) patient, rheumatic mitral disease; and in 23 (69.7%) patients, ischemic cardiomyopathy. According to the univariate regression model, the risk of death in the long-term period was increased by the QT interval prolongation (U 2.41, p = 0.0161); elevated pulmonary artery systolic pressure (U 4.30, p=0.0000) and increased left atrial size according to echocardiography (U 2.98, p=0.0029); stage IIB HF (OR 2.41; 95% CI: 1.26-4.6), NYHA III-IV (OR 3.03; 95% CI: 1.58-5.81); chronic obstructive pulmonary disease (OR 5.24; 95% CI: 2.04-13.45); and lack of optimal drug therapy (ODT) for HF before ICD implantation (OR 2.41; 95% CI: 1.29-4.49). The multivariate analysis identified the most significant factors included in the prognostic regression model: pulmonary artery systolic pressure above 45 mm Hg, social status, chronic obstructive pulmonary disease, and lack of ODT for HF. CONCLUSION: To ensure a maximum benefit from ICD, the factors that increase the likelihood of non-arrhythmic death should be considered before making a decision on ICD implantation. Particular attention should be paid to mandatory ODT for HF as the main modifiable risk factor for unfavorable prognosis.


Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca , Sistema de Registros , Humanos , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Femenino , Masculino , Pronóstico , Persona de Mediana Edad , Anciano , Estudios Prospectivos , Federación de Rusia/epidemiología , Causas de Muerte/tendencias , Factores de Riesgo
2.
Kardiologiia ; 62(12): 57-63, 2022 Dec 31.
Artículo en Ruso, Inglés | MEDLINE | ID: mdl-36636977

RESUMEN

Aim    To analyze long-term outcomes by results of the prospective part of the Kuban registry of patients with an implantable cardioverter defibrillator (ICD).Material and methods    A prospective analysis of the incidence of hard endpoints and changes in the condition was performed for 260 patients with ICD successively added to the Registry of Patients with Implantable Cardioverter Defibrillator" from 2015 through 2019.Results    At the time of ICD implantation, all patients had chronic heart failure (CHF), mostly of ischemic etiology with a low left ventricular ejection fraction (LVEF); median LVEF was 30 (25; 36.5) %. 54 of 266 (21.9 %) patients died by 2021; 17 of them (31.5 %) died in the hospital; in 76.5 % of cases, death was caused by acute decompensated heart failure (HF). 139 (53.5%) patients were readmitted; 66 (25.4 %) hospitalizations were related with ICDs (lead revision or reimplantation); acute cardiovascular events developed in 38 (14.6 %) patients; 12 (4.6%) patients underwent percutaneous coronary interventions; orthotopic heart transplantation was performed for 4 patients. ICD shocks were recorded in 27 (10.4 %) patients. After the ICD implantation, median LVEF remained unchanged, 31 (25; 42) vs. 30 (25; 36.5) % (р>0.05). However, both objective and subjective HF symptoms worsened. Thus, the number of patients with IIB stage CHF increased from 29.6  to 88.8 % (р<0.01) and with NYHA III CHF from 24.2  to 34.5 % (p<0.05). 80 (30.8%) patients visited cardiologists on a regular basis. Only 7.3% of patients received an optimal drug therapy. During the observation period, the rate of beta-blocker treatment considerably decreased, from 90.6  to 64.3 % (р<0.01), and the rate of the mineralocorticoid receptor antagonist treatment decreased from 50.8  to 17.4 % (р<0.01). The rate of the diuretic treatment was inconsistent with the severity of patients' condition.Conclusion    Most of the problems the patients encountered after the ICD implantation were related with an inadequate treatment of the underlying disease. Since the majority of patients with ICD have a low LVEF, it is essential to focus on prescribing an optimal drug therapy and maintaining compliance with this therapy.


Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Volumen Sistólico , Función Ventricular Izquierda , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Enfermedad Crónica , Sistema de Registros
3.
Nanotechnology ; 26(5): 055102, 2015 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-25586592

RESUMEN

Stable water-soluble complexes of Cd-free ZnSe/ZnS quantum dots (QDs) and chlorin e6 complexes have been prepared. These complexes have shown approximately 50% intracomplex fluorescence resonance energy transfer from QDs to chlorin e6. The photodynamic therapy (PDT) test of the complexes against the Erlich acsite carcinoma cell culture demonstrated a two-fold enhancement of the cancer cell photodynamic destruction as compared to that of free chlorin e6 molecules. It was shown that the PDT effect was significantly increased due to two factors: the efficient QD-chlorin e6 photoexcitation energy transfer and the improvement of cellular uptake of the photosensitizer in the presence of ZnSe/ZnS QDs.


Asunto(s)
Neoplasias/tratamiento farmacológico , Fotoquimioterapia , Fármacos Fotosensibilizantes/uso terapéutico , Porfirinas/uso terapéutico , Puntos Cuánticos , Animales , Clorofilidas , Femenino , Transferencia Resonante de Energía de Fluorescencia , Masculino , Ratones , Puntos Cuánticos/química , Células Tumorales Cultivadas
4.
Rev Sci Instrum ; 84(11): 116104, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24289445

RESUMEN

We describe an experimental setup for the characterization of luminescence from nanostructures. The setup is intended for steady-state and time-resolved luminescence measurements in the near-infrared region. The setup allows us to study spectral luminescence properties in the spectral range of 0.8-2.0 µm with high spectral resolution and kinetic luminescence properties between 0.8 and 1.7 µm with a time resolution of 3 ns. The capabilities of the system are illustrated by taking luminescence measurements from PbS quantum dots. We established the size dependencies of the optical properties of the PbS quantum dots over a wide spectral range. Finally, the energy transfer process was studied with a high temporal and spectral resolution.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA