Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 207
Filtrar
1.
J Arthroplasty ; 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38735552

RESUMEN

BACKGROUND: We previously reported the mean 6-year outcomes of total hip arthroplasty (THA) using fourth-generation ceramic-on-ceramic (CoC) articulations. With extended observations, this study aimed to report the mean 12-year outcomes focusing on bearing-related complications of CoC THA. METHODS: We reviewed primary CoC THAs performed between May 2009 and April 2012 at a single institution. Of the 831 hips (739 patients), 716 hips (635 patients) that satisfied a minimum 10-year follow-up were included. The mean age at operation was 54 years (range, 16 to 83). The occurrence of bearing-specific complications, including ceramic fractures and noise generation, was evaluated. The mean follow-up duration was 12 years (range, 10 to 14). RESULTS: A total of 2 (0.3%) ceramic liner fractures occurred, as previously reported. No additional ceramic fractures were observed during the extended follow-up period. However, the cumulative incidence of audible noise increased from 6.4 (48 of 749) to 8.2% (59 of 716). Of the 59 hips with noise, 26 (44.1%) developed noise within 1 year, whereas 13 (22.0%) presented with noise more than 5 years after THA. The noise was described as clicking in 35 hips (4.9%) and as squeaking in 24 hips (3.4%). No revision surgeries were performed for noise, except in 2 cases of concomitant liner fractures. The implant survivorship free of any revision was 98.1% at 12 years. CONCLUSIONS: No additional ceramic fractures were identified in this extension study at a minimum follow-up of 10 years. However, the prevalence of articular noise has increased from 6.4 to 8.2% since the previous report. Possible late-onset noise should be considered when performing CoC THA in younger patients.

2.
Chemosphere ; 353: 141570, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38447900

RESUMEN

Selective adsorption is the most suitable technique for eliminating trace amounts of 137Cs from various volumes of 137Cs-contaminated water, including seawater. Although various metal ferrocyanide (MFC)-functionalized magnetic adsorbents have been developed for the selective removal of 137Cs and magnetic recovery of adsorbents, their adsorption capacity for Cs remains low. Here, magnetic hierarchical titanium ferrocyanide (mh-TiFC) was synthesized for the first time for enhanced Cs adsorption. Hierarchical TiFC, comprising 2-dimensional TiFC flakes, was synthesized on SiO2-coated magnetic Fe3O4 particles using a sacrificial TiO2 shell as a source of Ti4+ via a reaction with ferrocyanide under acidic conditions. The resultant mh-TiFC exhibited the highest maximum adsorption capacity (434.8 mg g-1) and enhanced Cs selectivity with an excellent Kd value (6,850,000 mL g-1) compared to those of previously reported magnetic Cs adsorbents. This enhancement was attributed to the hierarchical structure, which reduced intracrystalline diffusion and increased the surface area available for direct Cs adsorption. Additionally, mh-TiFC (0.1 g L-1) demonstrated an excellent removal efficiency of 137Cs exceeding 99.85% for groundwater and seawater containing approximately 22 ppt 137Cs. Therefore, mh-TiFC offers promising applications for the treatment of 137Cs-contaminated water.


Asunto(s)
Radioisótopos de Cesio , Cesio , Contaminantes Químicos del Agua , Cesio/química , Agua/química , Titanio , Ferrocianuros/química , Dióxido de Silicio/química , Adsorción , Fenómenos Magnéticos , Contaminantes Químicos del Agua/análisis
3.
Int J Mol Sci ; 25(4)2024 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-38396893

RESUMEN

Rice is an important cereal crop worldwide, the growth of which is affected by rice blast disease, caused by the fungal pathogen Magnaporthe oryzae. As climate change increases the diversity of pathogens, the disease resistance genes (R genes) in plants must be identified. The major blast-resistance genes have been identified in indica rice varieties; therefore, japonica rice varieties with R genes now need to be identified. Because leucine-rich repeat (LRR) domain proteins possess R-gene properties, we used bioinformatics analysis to identify the rice candidate LRR domain receptor-like proteins (OsLRR-RLPs). OsLRR-RLP2, which contains six LRR domains, showed differences in the DNA sequence, containing 43 single-nucleotide polymorphisms (SNPs) in indica and japonica subpopulations. The results of the M. oryzae inoculation analysis indicated that indica varieties with partial deletion of OsLRR-RLP2 showed susceptibility, whereas japonica varieties with intact OsLRR-RLP2 showed resistance. The oslrr-rlp2 mutant, generated using clustered regularly interspaced palindromic repeats (CRISPR)/CRISPR-associated protein 9 (Cas9), showed increased pathogen susceptibility, whereas plants overexpressing this gene showed pathogen resistance. These results indicate that OsLRR-RLP2 confers resistance to rice, and OsLRR-RLP2 may be useful for breeding resistant cultivars.


Asunto(s)
Ascomicetos , Magnaporthe , Oryza , Magnaporthe/fisiología , Fitomejoramiento , Proteínas/metabolismo , Resistencia a la Enfermedad/genética , Proteínas Repetidas Ricas en Leucina , Oryza/microbiología , Enfermedades de las Plantas/microbiología , Proteínas de Plantas/genética , Proteínas de Plantas/metabolismo
4.
J Arthroplasty ; 39(4): 1007-1012, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37852443

RESUMEN

BACKGROUND: Although the modular sleeve concept for femoral implants has several advantages, studies reporting on greater than 20-year outcomes are limited. This study aimed to report the mean 23-year results of total hip arthroplasty (THA) using a modular stem with metaphyseal fixation sleeve. METHODS: This study reviewed primary THAs performed using a modular stem between October 1994 and April 1998. Of the 272 hips (221 patients) identified, 220 hips (177 patients) satisfying the minimum 20-year follow-up were included. The Harris Hip Score was used for clinical evaluation. Final hip radiographs were analyzed to evaluate the implant stability and the extent of femoral osteolysis. The mean follow-up duration was 23 years (range, 20 to 28). RESULTS: The mean Harris Hip Score improved from 38 points (range, 26 to 67) preoperatively to 90 points (range, 71 to 100) at the final follow-up (P < .001). Femoral osteolysis was observed in 146 hips (67.1%), but 145 were located proximal to the osseo-integrated sleeve. Overall, 4 femoral revisions were performed; 2 for chronic infection, one for aseptic loosening, and one for periprosthetic femoral fracture. Of the 19 (8.6%) periprosthetic femoral fractures, the most common type was Vancouver AG (13 hips). One (0.5%) asymptomatic distal stem fracture occurred, while no complications were identified at the stem-sleeve junction. Implant survivorship free of any femoral revision was 98.3% at 23 years. CONCLUSIONS: A THA using a modular stem with metaphyseal fixation sleeve demonstrated 98.3% stem survivorship with excellent clinical outcomes at a mean follow-up of 23 years in non-obese patients.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Fémur , Prótesis de Cadera , Osteólisis , Fracturas Periprotésicas , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Prótesis de Cadera/efectos adversos , Osteólisis/etiología , Osteólisis/cirugía , Estudios de Seguimiento , Reoperación/efectos adversos , Falla de Prótesis , Diseño de Prótesis , Fracturas Periprotésicas/cirugía , Fracturas Periprotésicas/complicaciones , Fracturas del Fémur/cirugía , Resultado del Tratamiento , Estudios Retrospectivos
5.
Chemosphere ; 346: 140668, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37949179

RESUMEN

Separating radioactive cesium from nuclear waste and contaminated environments is critical to mitigate radiological hazards. In response to this need, remote-controllable and Cs-selective micromotor adsorbents have been considered as a promising technology for rapid in-situ cleanup while minimizing secondary waste and radiation exposure to workers. In this study, we demonstrate the active and rapid removal of a radioactive contaminant from water by leveraging the magnetic manipulation capabilities of a helical and magnetic Ni micromotor coated with Cs-selective nickel ferrocyanide (NiFC). The use of polyvinyl alcohol fibers as a template enables the straightforward preparation of the helical wire structure, allowing for precise control over the diameter and pitch of the helix through simple twisting with Ni wires. By harnessing Ni2+ ions eluted from the Ni micromotor in an acid solution, we successfully fabricate NiFC-coated Ni (NiFC/Ni) micromotors that exhibit a selective removal efficiency greater than 98% for 137Cs, even in the presence of high concentrations of competing Na+ ions. Under the influence of an external magnetic field, the NiFC/Ni micromotor demonstrates rapid motion, achieving a pulling motion (100 body lengths per second) through a magnetic gradient and a tumbling motion (46 body lengths per second) induced by a rotating magnetic field. The tumbling motion of the NiFC/Ni micromotor substantially improves the Cs adsorption rate, resulting in a rate that surpasses that achieved under nonmoving conditions by a factor of 21. This improved adsorption rate highlights the considerable potential of magnetically manipulated micromotor self-propulsion for efficient water-pollution treatment.


Asunto(s)
Magnetismo , Agua , Humanos , Agua/química , Adsorción , Fenómenos Magnéticos
6.
Immunity ; 56(9): 2105-2120.e13, 2023 09 12.
Artículo en Inglés | MEDLINE | ID: mdl-37527657

RESUMEN

Childhood neglect and/or abuse can induce mental health conditions with unknown mechanisms. Here, we identified stress hormones as strong inducers of astrocyte-mediated synapse phagocytosis. Using in vitro, in vivo, and human brain organoid experiments, we showed that stress hormones increased the expression of the Mertk phagocytic receptor in astrocytes through glucocorticoid receptor (GR). In post-natal mice, exposure to early social deprivation (ESD) specifically activated the GR-MERTK pathway in astrocytes, but not in microglia. The excitatory post-synaptic density in cortical regions was reduced in ESD mice, and there was an increase in the astrocytic engulfment of these synapses. The loss of excitatory synapses, abnormal neuronal network activities, and behavioral abnormalities in ESD mice were largely prevented by ablating GR or MERTK in astrocytes. Our work reveals the critical roles of astrocytic GR-MERTK activation in evoking stress-induced abnormal behaviors in mice, suggesting GR-MERTK signaling as a therapeutic target for stress-induced mental health conditions.


Asunto(s)
Astrocitos , Fagocitosis , Estrés Psicológico , Animales , Niño , Humanos , Ratones , Astrocitos/metabolismo , Tirosina Quinasa c-Mer/genética , Hormonas/metabolismo , Sinapsis/metabolismo , Estrés Psicológico/metabolismo
7.
J Clin Med ; 12(11)2023 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-37297959

RESUMEN

We evaluated the clinical outcomes of using type 1 collagen gel after therapeutic resectoscopy; overall, 150 women aged > 20 who planned to undergo therapeutic resectoscopy were enrolled. The patients were randomly assigned to either of the anti-adhesive treatment groups: the type 1 collagen gel (Collabarrier®) (study group; N = 75) or the sodium hyaluronate and sodium carboxymethylcellulose gel group (control group; N = 75) after resectoscopy. One month after applying anti-adhesive materials, postoperative intrauterine adhesions were evaluated using second-look hysteroscopy; the incidence rate of postoperative intrauterine adhesions examined through second-look hysteroscopy showed no significant differences between the groups. There were no statistical differences between the frequency and mean scores of the type and intensity of adhesions in both groups. Finally, no significant differences in adverse events, serious adverse events, adverse device effects, and serious adverse device effects were noted between the two groups; type 1 collagen gel can be effectively and safely used in intrauterine surgery to minimize postoperative adhesions, thereby eventually decreasing the prevalence of infertility, secondary amenorrhea, and recurrent pregnancy loss in reproductive women.

8.
J Arthroplasty ; 38(11): 2379-2385, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37271230

RESUMEN

BACKGROUND: Periprosthetic femoral fractures (PFFs) remain a major concern following cementless total hip arthroplasty (THA). This study aimed to evaluate the association between different types of cementless tapered stems and the risk of postoperative PFF. METHODS: A retrospective review of primary THAs performed at a single center from January 2011 to December 2018 included 3,315 hips (2,326 patients). Cementless stems were classified according to their design. The incidence of PFF was compared between flat taper porous-coated stems (type A), rectangular taper grit-blasted stems (type B1), and quadrangular taper hydroxyapatite-coated stems (type B2). Multivariate regression analyses were performed to identify independent factors related to PFF. The mean follow-up duration was 61 months (range, 12 to 139). Overall, 45 (1.4%) postoperative PFFs occurred. RESULTS: The incidence of PFF was significantly higher in type B1 stems than in type A and type B2 stems (1.8 versus 0.7 versus 0.7%; P = .022). Additionally, more surgical treatments (1.7 versus 0.5 versus 0.7%; P = .013) and femoral revisions (1.2 versus 0.2 versus 0%; P = .004) were required for PFF in type B1 stems. After controlling for confounding variables, older age, diagnosis of hip fracture, and use of type B1 stems were significant factors associated with PFF. CONCLUSION: Type B1 rectangular taper stems were found to have higher risks for postoperative PFF and PFF requiring surgical management than type A and type B2 stems in THA. Femoral stem geometry should be considered when planning for cementless THA in elderly patients who have compromised bone quality.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Fémur , Prótesis de Cadera , Fracturas Periprotésicas , Humanos , Anciano , Artroplastia de Reemplazo de Cadera/efectos adversos , Prótesis de Cadera/efectos adversos , Fracturas del Fémur/epidemiología , Fracturas del Fémur/etiología , Fracturas del Fémur/cirugía , Fracturas Periprotésicas/epidemiología , Fracturas Periprotésicas/etiología , Fracturas Periprotésicas/cirugía , Fémur/cirugía , Reoperación/efectos adversos , Estudios Retrospectivos , Diseño de Prótesis , Factores de Riesgo
9.
Adv Mater ; 35(13): e2208184, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36601963

RESUMEN

Mechanically stretchable strain sensors gain tremendous attention for bioinspired skin sensation systems and artificially intelligent tactile sensors. However, high-accuracy detection of both strain intensity and direction with simple device/array structures is still insufficient. To overcome this limitation, an omnidirectional strain perception platform utilizing a stretchable strain sensor array with triangular-sensor-assembly (three sensors tilted by 45°) coupled with machine learning (ML) -based neural network classification algorithm, is proposed. The strain sensor, which is constructed with strain-insensitive electrode regions and strain-sensitive channel region, can minimize the undesirable electrical intrusion from the electrodes by strain, leading to a heterogeneous surface structure for more reliable strain sensing characteristics. The strain sensor exhibits decent sensitivity with gauge factor (GF) of ≈8, a moderate sensing range (≈0-35%), and relatively good reliability (3000 stretching cycles). More importantly, by employing a multiclass-multioutput behavior-learned cognition algorithm, the stretchable sensor array with triangular-sensor-assembly exhibits highly accurate recognition of both direction and intensity of an arbitrary strain by interpretating the correlated signals from the three-unit sensors. The omnidirectional strain perception platform with its neural network algorithm exhibits overall strain intensity and direction accuracy around 98% ± 2% over a strain range of ≈0-30% in various surface stimuli environments.

10.
J Arthroplasty ; 38(7): 1335-1341, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36709880

RESUMEN

BACKGROUND: Cementing a new liner into a secure, well-positioned metallic shell can be a less-invasive strategy in revision total hip arthroplasty (THA). This study aimed to report the mean 14-year outcomes of cementing highly cross-linked polyethylene (XLPE) liners into well-fixed acetabular shells in revision THAs. METHODS: This study reviewed a single-surgeon series of cementing XLPE liners into well-fixed acetabular components. Of the 52 hips (51 patients) evaluated, 48 hips (47 patients) that satisfied a minimum follow-up of 10 years were included. The Harris Hip score was used for clinical evaluation. Final hip radiographs were used to determine the extent of acetabular osteolysis and stability of the components. The mean age at index operation was 53 years (range, 32 to 72). The mean follow-up duration was 14 years (range, 10 to 18). RESULTS: The mean Harris Hip score improved from 58 points (range, 23-81) preoperatively to 91 points (range, 45-100) at the final evaluation (P < .001). A total of 3 acetabular rerevisions were performed, all for aseptic loosening of the outer shell. One postoperative dislocation occurred, but it was successfully treated with a closed reduction. Final radiographs showed a significant reduction in acetabular osteolysis (P < .001). Implant survivorship free from any rerevision was 93.3% (95% confidence interval, 85.9-100%) at 14 years. CONCLUSION: Cementing an XLPE liner into a well-fixed acetabular shell in revision THA demonstrated excellent clinical and radiographic outcomes at a mean of 14 years postoperatively. This technique could be a safe and durable option in the absence of XLPE liners compatible with preimplanted shells.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Osteólisis , Humanos , Adulto , Persona de Mediana Edad , Anciano , Artroplastia de Reemplazo de Cadera/métodos , Polietileno , Osteólisis/etiología , Osteólisis/cirugía , Falla de Prótesis , Acetábulo/cirugía , Reoperación , Diseño de Prótesis , Estudios de Seguimiento
11.
J Arthroplasty ; 38(8): 1621-1627, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-36720417

RESUMEN

BACKGROUND: Iliopsoas tendinopathy (IPT) can cause persistent groin pain and lead to dissatisfaction after total hip arthroplasty (THA). This study aimed to report the characteristics, incidences, risk factors, and treatment outcomes of IPT after THA. METHODS: We reviewed primary THAs performed at a single institution between January 2012 and May 2018. Clinical and radiographic analyses were performed on 1,602 THAs (1,370 patients). Patient characteristics, component sizes, inclination and anteversion angles, and antero-inferior cup prominence (≥8 millimeters (mm)), were compared between the groups with and without IPT. Changes in teardrop to lesser trochanter distance were measured to estimate changes in leg length and horizontal offset caused by THA. Logistic regression models were used to identify the risk factors for IPT. IPT was identified in 53 hips (3.3%). RESULTS: Patients with IPT had greater leg lengthening (12.3 versus 9.3 mm; P = .001) and higher prevalence of antero-inferior cup prominence (5.7 versus 0.4%; P = .002). There was no significant difference in inclination, anteversion, and horizontal offset change between the two groups. In multivariate analyses, greater leg lengthening, prominent acetabular cup, women, and higher body mass index were associated with IPT. All patients reported improvement in groin pain after arthroscopic tenotomy, while 35.7% with nonoperative management reported improvement (P < .001). CONCLUSIONS: Symptomatic IPT occurred in 53 (3.3%) of the 1,602 primary THAs. Our findings suggest that leg lengthening as well as prominent acetabular cup in THAs can be associated with the development of IPT. Arthroscopic tenotomy was effective in relieving groin pain caused by IPT.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Tendinopatía , Humanos , Femenino , Artroplastia de Reemplazo de Cadera/efectos adversos , Incidencia , Acetábulo/cirugía , Tendinopatía/diagnóstico por imagen , Tendinopatía/epidemiología , Tendinopatía/etiología , Factores de Riesgo , Dolor/cirugía , Prótesis de Cadera/efectos adversos , Estudios Retrospectivos
12.
ACS Appl Mater Interfaces ; 14(43): 49303-49312, 2022 Nov 02.
Artículo en Inglés | MEDLINE | ID: mdl-36241609

RESUMEN

Stretchable electronics have become essential for custom-built electronics, self-assembling robotics, and wearable devices. Although many stretchable electronics contain integrated systems, they still limit bulky connection systems. We introduce a new dual-functioned self-attachable and stretchable interface (SASI), allowing a direct and instant interconnection between rigid and soft electronics. The SASI consists of a sticky and stretchable substrate and surface-embedded serpentine conductors with the single-sided polyimide fabricated using the embedded transfer process. The adhesion property of the SASI is controlled by the mixed elastomer ratio. The resulting sticky and conductive SASI can instantly adhere to a metal surface and create conductive paths. The SASI serpentine conductors exhibit high stretchability (∼290%) and provide self-attachable, re-attachable, and low-resistant electrical contacts (0.85 ohms in 0.25 mm2) between interfaces without pressure, heat, or extra solder. In addition, three-dimensional curved and modular electronics can be formed with the SASI by compiling functional blocks. SASI provides a novel strategy for assembling functional chips or modules for stretchable electronics, opening a path to onboard integrated electronics that are customizable by users for real-world stretchable electronics.

13.
World J Clin Cases ; 10(24): 8656-8661, 2022 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-36157820

RESUMEN

BACKGROUND: Hypovolemic shock can lead to life-threatening organ dysfunction, and adequate fluid administration is a fundamental therapy. Traditionally, parameters such as vital signs, central venous pressure, and urine output have been used to estimate intravascular volume. Recently, pulse pressure variation (PPV) and non-invasive cardiac monitoring devices have been introduced. In this case report, we introduce a patient with massive active bleeding from giant renal angiomyolipoma (AML). During emergent nephrectomy, we used non-invasive cardiac monitoring with CSN-1901 (Nihon Kohden, Tokyo, Japan) and PPV to evaluate the patient's intravascular volume status to achieve optimal fluid management. CASE SUMMARY: A 30-year-old male patient with giant AML with active bleeding was referred to the emergency room complaining of severe abdominal pain and spontaneous abdominal distension. AML was diagnosed by computed tomography, and emergent nephrectomy was scheduled. Massive bleeding was expected so we decided to use non-invasive cardiac monitoring and PPV to assist fluid therapy because they are relatively easy and fast compared to invasive cardiac monitoring. During the surgery, 6000 mL of estimated blood loss occurred. Along with the patient's vital signs and laboratory results, we monitored cardiac output, cardiac output, stroke volume, stroke volume index with a non-invasive cardiac monitoring device, and PPV using an intra-arterial catheter to evaluate intravascular volume status of the patient to compensate for massive bleeding. CONCLUSION: In addition to traditional parameters, non-invasive cardiac monitoring and PPV are useful methods to evaluate patient's intravascular volume status and provide guidance for intraoperative management of hypovolemic shock patients.

14.
Nat Commun ; 13(1): 4963, 2022 Aug 24.
Artículo en Inglés | MEDLINE | ID: mdl-36002441

RESUMEN

Transistors with inorganic semiconductors have superior performance and reliability compared to organic transistors. However, they are unfavorable for building stretchable electronic products due to their brittle nature. Because of this drawback, they have mostly been placed on non-stretchable parts to avoid mechanical strain, burdening the deformable interconnects, which link these rigid parts, with the strain of the entire system. Integration density must therefore be sacrificed when stretchability is the first priority because the portion of stretchable wirings should be raised. In this study, we show high density integration of oxide thin film transistors having excellent performance and reliability by directly embedding the devices into stretchable serpentine strings to defeat such trade-off. The embedded transistors do not hide from deformation and endure strain up to 100% by themselves; thus, integration density can be enhanced without sacrificing the stretchability. We expect that our approach can create more compact stretchable electronics with high-end functionality than before.

15.
Injury ; 53(10): 3423-3429, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35927068

RESUMEN

INTRODUCTION: A residual fracture gap after intramedullary nailing is a known risk factor for delayed union and non-union. This study aimed to report the outcomes of a forward-striking technique to reduce fracture gaps during long cephalomedullary nailing in subtrochanteric femoral fractures (SFFs). METHODS: A retrospective cohort study was conducted on patients with SFFs treated in a single institution between February 2013 and October 2018. A total of 58 patients treated via long cephalomedullary nailing with a forward-striking technique were included. The width of the fracture gap, location of the cephalic screw, tip-apex distance (TAD), and time to bone union were evaluated using intraoperative and postoperative radiographs. Complication rates, including fixation failure, non-union, implant breakage, and infection, were assessed. The mean follow-up duration was 4 (range, 2‒8) years. RESULTS: Of the 58 patients (mean age, 67.9 years), 38 (65.5%) were female. Thirty-two cases (55.2%) were classified as atypical femoral fractures. The mean fracture gap reduced from 5.1 mm to 1.6 mm by forward striking (P<0.001). The reduced fracture gap was significantly greater in atypical SFFs (mean, 4.9 mm vs. 1.7 mm; P<0.001). The lag screw was located in the center-center or center-inferior zones of the femoral head in 54 patients (93.1%). The mean TAD was 14.2 mm and was under 25 mm in 55 patients (94.8%). Bone union was achieved in all cases without reoperation at a mean of 5.4 months. One incident of lag screw breakage was noted at 5 months, but bone union was achieved at 7 months. CONCLUSIONS: The forward-striking technique with a long cephalomedullary nail demonstrated a 100% bone union rate in a consecutive series of 58 SFFs. This technique is effective in reducing the fracture gap as well as placing the cephalic screw into the optimal position. The forward-striking technique was particularly effective in reducing atypical SFFs with a transverse or short oblique configuration.


Asunto(s)
Fracturas del Fémur , Fijación Intramedular de Fracturas , Fracturas de Cadera , Anciano , Clavos Ortopédicos/efectos adversos , Femenino , Fracturas del Fémur/diagnóstico por imagen , Fracturas del Fémur/etiología , Fracturas del Fémur/cirugía , Fijación Intramedular de Fracturas/métodos , Fracturas de Cadera/diagnóstico por imagen , Fracturas de Cadera/etiología , Fracturas de Cadera/cirugía , Humanos , Masculino , Estudios Retrospectivos , Resultado del Tratamiento
16.
J Hazard Mater ; 436: 129165, 2022 08 15.
Artículo en Inglés | MEDLINE | ID: mdl-35739705

RESUMEN

Nanozyme-based dye degradation methods are promising for the remediation of water pollution. Though Pd nanoparticles (PdNPs) are known to act as nanozymes, their dye degradation capability has not been investigated. Low nanozyme activities, easy aggregation, difficulties in recovery and reuse are the major challenges in achieving this. For the first time, cellulose nanofibrils-supported PdNPs (PdNPs/PCNF) as a novel nanozyme with good peroxidase and oxidase-mimicking activities and easy recyclability is explored for dye degradation. An efficient and rapid method of PdNPs/PCNF preparation was demonstrated by adjusting the pH and microwave irradiation. Enzyme kinetic studies revealed good kinetic parameters and specific activities of 415 and 277 U/g for peroxidase and oxidase, respectively. PdNPs/PCNF offered 99.64% degradation of methylene blue within 12 min (0.468 min-1) with 0.4 M H2O2 at pH 5.0. Mechanistic studies revealed the involvement of hydroxyl and superoxide radicals. Owing to the network-like structure of PCNF, films and foams were prepared, their dye degradation potentials were compared, and recyclability was tested. Successful degradation of mixed dye solutions and spiked real water samples was achieved and a continuous flow method was demonstrated using a foam-packed column.


Asunto(s)
Nanopartículas , Peroxidasa , Celulosa , Colorantes/química , Peróxido de Hidrógeno , Cinética , Nanopartículas/química , Oxidorreductasas/metabolismo , Peroxidasa/metabolismo
17.
J Arthroplasty ; 37(12): 2420-2426, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35753649

RESUMEN

BACKGROUND: Tapered modular stems are increasingly used in revision total hip arthroplasty (THA) with deficient femoral bone stock. This study aimed to report the long-term outcomes of revision THA using a tapered and fluted modular stem. METHODS: Between December 1998 and February 2006, 113 revision THAs (110 patients) were performed with a tapered and fluted modular stem at a single institution. Hip radiographs were used to identify stem subsidence, stability, and femoral radiolucency. Final outcomes were assessed in 72 hips (70 patients), with a minimum follow-up of 10 years. RESULTS: The mean follow-up duration was 16 years (range, 10-23). At the final evaluation, the Harris Hip Score improved from a mean of 41 points (range, 10-72) preoperatively to 83 points (range, 56-100) (P < .001). Six femoral re-revisions were performed for the following reasons: 1 aseptic loosening, 2 stem fractures, and 3 infections. One stem fracture occurred at the modular junction after 14 years, and the other at a more distal location after 15 years. Stem subsidence was >5 mm in 6 hips (9.1%), but secondary stability was achieved in all stems. Osseointegration was observed in 63 (95.5%) hips. Stem survivorship was 91.1% with an end point of any re-revision and 94.6% for aseptic re-revision. CONCLUSION: A tapered and fluted modular stem demonstrated excellent implant survivorship with reliable bony fixation at a mean follow-up of 16 years. This type of stem can be a durable option for revision THA in patients who have femoral defects.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Prótesis de Cadera/efectos adversos , Diseño de Prótesis , Estudios de Seguimiento , Reoperación , Fémur/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Falla de Prótesis
18.
Chemosphere ; 295: 133874, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35131267

RESUMEN

We have modified the ion-exchange affinity of nano-Hydroxyapatite (Ca5(PO4)3OH, HAP) surface for the rapid and selective adsorption of 90Sr from groundwater. The modification was achieved by the post-substitution of cations (Na+, Mg2+, Cu2+, Ba2+, Fe3+, and Al3+) for parent Ca2+ within surface structure of HAP. The diffraction patterns of modified HAP showed a slight shift of the (002) peak between 25° and 27° 2θ depending the ionic radius of the substituted cation. Magnesium substituted HAP, Mg-HAP, exhibited the highest removal efficiency (>95%) for 10 ppm of Sr2+, which is attributable to the higher ion-exchange affinity of substituted Mg2+ than parent Ca2+ toward Sr2+. The results of various analyses revealed that Mg substitution dominantly occurred at the CaI site of HAP, which enabled the Mg-HAP to adsorb Sr2+ at both of CaI and CaII sites whereas bare HAP could adsorb Sr2+ mainly at CaII site. Adsorption isotherms and the kinetics of Mg-HAP for Sr2+ were evaluated using a bi-Langmuir isotherm and a pseudo-second-order kinetic model, which demonstrated the Mg-HAP exhibited the highest adsorption capacity (64.69 mg/g) and fastest adsorption kinetics (0.161-1.714 g/(mg·min)) than previously modified HAPs. In the presence of competing cations at circumneutral pHs, the enhanced performance of the Mg-HAP led to a greater than 97% reduction of 90Sr (initial radioactivity = 9500 Bq/L) within 1 h. The distribution coefficient of Mg-HAP was 1.3-6.6 × 103 mL/g while that of bare HAP was 1.2-6.6 × 102 mL/g. The findings in the present study highlight that the ion-exchange affinity of CaI and CaII sites on HAP surface plays a key-role in 90Sr uptake. The proposed modification method can simply increase the affinity of HAP surface, therefore, this work can further improve the deployment of an in situ remediation technology for 90Sr contaminated groundwater, i.e., Mg-HAP-based permeable reactive barrier.


Asunto(s)
Agua Subterránea , Radiactividad , Adsorción , Durapatita/química , Magnesio , Radioisótopos de Estroncio
19.
PLoS One ; 17(2): e0264140, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35202410

RESUMEN

PURPOSE: Early detection and classification of bone tumors in the proximal femur is crucial for their successful treatment. This study aimed to develop an artificial intelligence (AI) model to classify bone tumors in the proximal femur on plain radiographs. METHODS: Standard anteroposterior hip radiographs were obtained from a single tertiary referral center. A total of 538 femoral images were set for the AI model training, including 94 with malignant, 120 with benign, and 324 without tumors. The image data were pre-processed to be optimized for training of the deep learning model. The state-of-the-art convolutional neural network (CNN) algorithms were applied to pre-processed images to perform three-label classification (benign, malignant, or no tumor) on each femur. The performance of the CNN model was verified using fivefold cross-validation and was compared against that of four human doctors. RESULTS: The area under the receiver operating characteristic (AUROC) of the best performing CNN model for the three-label classification was 0.953 (95% confidence interval, 0.926-0.980). The diagnostic accuracy of the model (0.853) was significantly higher than that of the four doctors (0.794) (P = 0.001) and also that of each doctor individually (0.811, 0.796, 0.757, and 0.814, respectively) (P<0.05). The mean sensitivity, specificity, precision, and F1 score of the CNN models were 0.822, 0.912, 0.829, and 0.822, respectively, whereas the mean values of four doctors were 0.751, 0.889, 0.762, and 0.797, respectively. CONCLUSIONS: The AI-based model demonstrated high performance in classifying the presence of bone tumors in the proximal femur on plain radiographs. Our findings suggest that AI-based technology can potentially reduce the misdiagnosis of doctors who are not specialists in musculoskeletal oncology.


Asunto(s)
Inteligencia Artificial , Neoplasias Óseas/clasificación , Fémur , Radiografía/métodos , Algoritmos , Neoplasias Óseas/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador , Redes Neurales de la Computación , Variaciones Dependientes del Observador , Curva ROC , Reproducibilidad de los Resultados
20.
Int Orthop ; 46(4): 789-795, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35064307

RESUMEN

BACKGROUND: Recurrent dislocation is a difficult complication after total hip arthroplasty (THA). This study aimed to report the clinical and radiographic outcomes of revision THA using the modular dual mobility (MDM) acetabular system to treat recurrent dislocation. METHODS: Between March 2015 and February 2019, 34 revision THAs were performed using the MDM system for treating recurrent dislocation in a single institution. Of these, 32 revision THAs (32 patients) that satisfied a minimum follow-up of one year (mean, 4 years) were included in this study. Patient-reported outcomes, complication rates, and radiographic results were evaluated. RESULTS: Seventeen patients (53.1%) had lumbar degenerative kyphosis, and six (18.8%) had surgically fused lumbar spines during the index operation. All acetabular components were revised, whereas femoral stems were retained in 29 patients (90.6%). No redislocation or intraprosthetic dislocation was noted after revision. One additional revision was required for acetabular loosening with periprosthetic joint infection. No additional revision was performed for aseptic loosening. A partial radiolucent line was found in two hips (6.3%) confined to one acetabular zone. CONCLUSIONS: Revision THA using the MDM system was effective in treating recurrent dislocation in a group of patients with a high prevalence of lumbar spinal pathology. During a mean follow-up of 4 years, one additional revision THA was performed for septic loosening and none for aseptic loosening.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Luxación de la Cadera , Prótesis de Cadera , Luxaciones Articulares , Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Estudios de Seguimiento , Luxación de la Cadera/etiología , Luxación de la Cadera/cirugía , Prótesis de Cadera/efectos adversos , Humanos , Luxaciones Articulares/cirugía , Diseño de Prótesis , Falla de Prótesis , Reoperación/efectos adversos , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...