Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Nutrients ; 16(5)2024 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-38474872

RESUMEN

Sodium bicarbonate is used as an ergogenic supplement to enhance people's performances in various exercises. This study aimed to evaluate the effects of intestinal delivery of sodium bicarbonate on bicarbonate absorption and associated side effects in an experimental human trial. After preparing and assessing enteric-coated and uncoated sodium bicarbonate tablet formulations, pharmacokinetic analysis and gastrointestinal symptom tests were performed after oral administration in the human body. The dose required to increase blood bicarbonate concentration over 5 mmol∙L-1 for the purpose of improving performance during high-intensity exercise was also determined. Enteric-coated tablet formulation protects sodium bicarbonate under acidic conditions and releases bicarbonate in the intestine. Enteric-coated tablet formulation also reduced the oral dose required to achieve a blood bicarbonate concentration over 5 mmol∙L-1 from 300 mg∙kg-1 of uncoated tablet formulation to 225 mg∙kg-1. Gastrointestinal discomfort was significantly decreased for the group given 225 mg∙kg-1 enteric-coated tablets compared to that given 300 mg∙kg-1 uncoated tablets. These results suggest that enteric-coated tablet formulation could reduce the oral dose required in order to achieve a blood bicarbonate concentration over 5 mmol∙L-1 by 25%, from 300 mg∙kg-1 to 225 mg∙kg-1, along with its ability to reduce gastrointestinal discomfort associated with the dosage.


Asunto(s)
Bicarbonatos , Bicarbonato de Sodio , Humanos , Administración Oral , Disponibilidad Biológica , Comprimidos Recubiertos
2.
Biosens Bioelectron ; 176: 112894, 2021 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-33358286

RESUMEN

We report a new paper-based multiplex analytical device (mPAD) for simultaneous screening of three analytes (glutamate dehydrogenase, toxin A, and toxin B) known as biomarkers for Clostridioides difficile infection (CDI). To overcome the limitation of common rapid assays (e.g. lateral flow immunochromatographic and enzyme immunoassays) in terms of multiplexing, sensitivity, simplicity, and ease-of-use, the mPAD is constructed with a three dimensional (3D) configuration of paper components with a multi-channel design. Multiple fluidic paths developed with wax-patterned paper allow the simultaneous detection of glutamate dehydrogenase, toxin A, and toxin B without any cross-reactivity. The 3D fluidic network on the mPAD facilitates a self-operating test procedure for the mixing and addition of amplification reagents with a one-step sliding operation. The results of the multiplex CDI assay can be easily interpreted by the naked eye within 10 min, and are visually intensified over time resulting in up to 3-fold signal amplification. Our device exhibited remarkable analytical performances for the simultaneous detection of three CDI biomarkers, providing a sensitivity of 97%, specificity of 88%, accuracy of 95%, and limits of detection for glutamate dehydrogenase, toxin A, and toxin B of 0.16 ng mL-1, 0.09 ng mL-1, and 0.03 ng mL-1, respectively. These results indicate the high applicability and feasibility of mPAD for multiplex testing for CDI with the advantages of being simple, sensitive, inexpensive, user-friendly, and equipment-free.


Asunto(s)
Toxinas Bacterianas , Técnicas Biosensibles , Clostridioides difficile , Proteínas Bacterianas , Clostridioides , Heces , Glutamato Deshidrogenasa , Sensibilidad y Especificidad
3.
Korean J Fam Med ; 41(6): 398-403, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32418394

RESUMEN

BACKGROUND: Systemic Clinic Outcome and Routine Evaluation (SCORE-15) is a compact scale that contains the most critical family function assessment tools including assessments of the strengths, adaptability, and communication among family members. It has been translated into other languages in the United States and Europe. This study aimed to verify the reliability and validity of SCORE-15 with a small research population and justify its applicability in Korea. METHODS: SCORE-15 is a self-reporting family function measurement tool for each family member over the age of 11 years. This study used the Family Communication Scale (FCS) included in the Family Adaptability and Cohesion Evaluation Scales (FACES) IV package and FACES in FACES-III to verify the validity of the Korean-translated SCORE-15. Cronbach's α value was calculated to check the reliability of SCORE-15. Data were analyzed using STATA ver. 15.0 (Stata Corp., College Station, TX, USA). RESULTS: The study analyzed the correlation between FACES-III and SCORE-15 and FCS and SCORE-15 so that there was a significant static correlation in both comparisons (r=0.72 and r=0.81, respectively). Also, the research compared each subscale to analyze the correlation and the range was 0.47 to 0.95. The total SCORE-15 Cronbach's α value was 0.92 and those values of the subscales for family strengths, family communication, and family difficulty were 0.89, 0.73, and 0.87, respectively (P<0.001). CONCLUSION: Our study was the first to validate the Korean SCORE-15, which can be used as an appropriate shortform indicator for evaluating family function and changes in detecting therapeutic improvements in Korea.

4.
Rev Sci Instrum ; 90(5): 054705, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-31153245

RESUMEN

Design and implementation of a low-loss K-band duplexer consisting of two narrow bandpass filters with low-impedance open-loop resonators (OLRs) is presented. Narrow bandpass filters of 4%-7% bandwidth were often implemented with OLRs, but previous designs used OLRs mostly with 50 Ω linewidth. The design process was complicated due to multiple coupling mechanisms and multiple spurious response frequencies, often resulting in excessive insertion loss, especially at higher center frequencies. With the proposed design procedure for OLR filters, the values of the low-impedance line (less than 50 Ω) and proper coupling spacing are determined in the process of optimizing the filter performance, resulting in low insertion loss up to above K-band frequencies. The size of the proposed filter is also reduced to 64% of the conventional OLR filters. As an example of the proposed design method, a duplexer consisting of 4% narrow bandpass filters centered at 18.7 GHz and 22.5 GHz was implemented and measured, and the maximum insertion loss in each passband was 1.2 dB, which is much less than those of the previous design approaches.

5.
Toxicol Res ; 30(4): 305-9, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25584151

RESUMEN

Recently, there has been an increase in the use of several nephrotoxicity biomarkers in preclinical experiments. In addition, it has been indicated that the result may have been influenced by secondary factors, such as sample storage condition or storage period. In this study, we have assessed the variation in urinary nephrotoxicity biomarkers as a result of urine storage conditions and storage period of the urine. Urine was sampled from specific pathogen-free Sprague-Dawley rats (19 weeks old), which were housed individually in hanged stainless steel wire mesh cages. Urine was stored at 20℃, at 4℃, or at -70℃ after sampling. The levels of the biomarkers such as beta-2 microglobulin (B2M), cystatin-C (Cys-C), N-acetyl-ß- D-glucosaminidase (NAG), micro albumin (MA), micro protein (MP) were measured at 6, 24, 48 and 144 hr after sampling. The B2M level was significantly decreased at 6, 24, 48, and 144 hr compared to 0 hr at -70℃ (p < 0.05, p < 0.01, p < 0.05, and p < 0.05, respectively) and 24 and 144 hr at 20℃ (p < 0.01, p < 0.01, respectively). The Cys-C level was significantly decreased at 144 hr compared to 0 hr at 4℃ (p < 0.01), at 20℃ (p < 0.05) and at 70℃ (p < 0.01). MP and MA levels were not different for 144 hr in all storage conditions. Taken together, B2M and Cys-C levels were modulated by storage temperature and period. For the enhancement of test accuracy, it is suggested that strict protocols be established for samples to minimize the effects of the storage conditions on the detected levels of biomarkers.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...